Browse > Article
http://dx.doi.org/10.3340/jkns.2009.46.2.130

A Morphometric Aspect of the Brachial Plexus in the Periclavicular Region  

Lee, Jung-Pyo (Department of Neurosurgery, College of Medicine, Soonchunhyang University)
Chang, Jae-Chil (Department of Neurosurgery, College of Medicine, Soonchunhyang University)
Cho, Sung-Jin (Department of Neurosurgery, College of Medicine, Soonchunhyang University)
Park, Hyung-Ki (Department of Neurosurgery, College of Medicine, Soonchunhyang University)
Choi, Soon-Kwan (Department of Neurosurgery, College of Medicine, Soonchunhyang University)
Bae, Hack-Gun (Department of Neurosurgery, College of Medicine, Soonchunhyang University)
Publication Information
Journal of Korean Neurosurgical Society / v.46, no.2, 2009 , pp. 130-135 More about this Journal
Abstract
Objective: The purpose of this study was to determine the normal morphometric landmarks of the uniting and dividing points of the brachial plexus (BP) in the periclavicular region to provide useful guidance in surgery of BP injuries. Methods: A total of 20 brachial plexuses were obtained from 10 adult, formalin-fixed cadavers. Distances were measured on the basis of the Chassaignac tubercle (CT), and the most lateral margin of the BP (LMBP) crossing the superior and inferior edge of the clavicle. Results: LMBP was located within 25 mm medially from the midpoint in all subjects. In the supraclavicular region, the upper trunk uniting at 21$\pm$7 mm from the CT, separating into divisions at 42$\pm$5 mm from the CT, and dividing at 19$\pm$4 mm from the LMBP crossing the superior edge of the clavicle. In the infraclavicular region, the distance from the inferior edge of the clavicle to the musculocutaneous nerve (MCN) origin was 49$\pm$12 mm, to the median nerve origin 57$\pm$7 mm, and the ulnar nerve origin 48$\pm$6 mm. From the lateral margin of the pectoralis minor to the MCN origin the distance averaged 3.3$\pm$10 mm. Mean diameter of the MCN was 4.3$\pm$1.1 mm (range, 2.5-6.0) in males (n = 6), and 3.1$\pm$1.5 mm (range, 1.6-4.0) in females (n = 4). Conclusion: We hope these data will aid in understanding the anatomy of the BP and in planning surgical treatment in BP injuries.
Keywords
Brachial plexus; Musculocutaneous nerve; Clavicle; Pectoralis muscles;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By Web Of Science : 2  (Related Records In Web of Science)
Times Cited By SCOPUS : 2
연도 인용수 순위
1 Blaauw G, Slooff AC : Transfer of pectoral nerves to the musculocutaneousnerve in obstetric upper brachial plexus palsy. Neurosurgery53 : 338-341; discussion 341-342, 2003   DOI   PUBMED   ScienceOn
2 Guha A, Graham B, Kline DG, Hudson AR : Brachial plexus injuries,in Wilkins RH, Rengachary SS. Neurosurgery 2nd ed. New York McGraw-Hill, 1996, pp3121-3122
3 Kawai H, Kawabata H, Masada K, Ono K, Yamamoto K,Tsuyuguchi Y, et al. : Nerve repairs for traumatic brachial plexus palsywith root avulsion. Clin Orthop Relat Res 237 : 75-86, 1988   PUBMED
4 Parent A : Carpenter's human neuroanatomy. ed 9. Philadelphia :Lippincott, Williams & Wilkins, 1966, pp275-283
5 Slingluff CL, Terzis JK, Edgerton MT: The quantitative microanatomyof the brachial plexus in man, in Terzis JK (eds) : Microreconstructionof nerve injury. WB Saunders, 1987, pp285-324
6 Uysal II, Seker M, Karabulut AK, B$\ddot{u}$y$\ddot{u}$kmumcu M, Ziylan T :Brachial plexus variations in human fetuses. Neurosurgery 53 : 676-684; discussion 684, 2003   DOI   PUBMED   ScienceOn
7 Lee HY, Chung IH, Sir WS, Kang HS, Lee HS, Ko JS, et al. :Variations of the ventral rami of the brachial plexus. J Korean MedSci 7 : 19-24, 1992   DOI   PUBMED
8 Kline DG, Judice DJ : Operative management of selected brachialplexus lesions. J Neurosurg 58 : 631-649, 1983   DOI   PUBMED
9 Belzberg AJ, Dorsi MJ, Storm PB, Moriarity JL : Surgical repair ofbrachial plexus injury : a multinational survey of experiencedperipheral nerve surgeons. J Neurosurg 101 : 365-376, 2004   DOI   ScienceOn
10 Narakas AO, Hentz VR : Neurotization in brachial plexus injuries.Indication and results. Clin Orthop Relat Res : 43-56, 1988   PUBMED
11 Bertelli JA, Ghizoni MF : Brachial plexus avulsion injury repairs withnerve transfers and nerve grafts directly implanted into the spinal cordyield partial recovery of shoulder and elbow movements. Neurosurgery52 : 1385-1389; discussion 1389-1390, 2003   DOI   PUBMED   ScienceOn
12 Haninec P, Sámal F, Tomás R, Houstava L, Dubovwy P: Directrepair (nerve grafting), neurotization, and end-to-side neurorrhaphyin the treatment of brachial plexus injury. J Neurosurg 106 : 391-399, 2007   DOI   ScienceOn
13 Samii M, Carvalho GA, Nikkhah G, Penkert G : Surgical reconstructionof the musculocutaneous nerve in traumatic brachial plexusinjuries. J Neurosurg 87 : 881-886, 1997   DOI   ScienceOn
14 Wolock B, Millesi H : Brachial plexus-applied anatomy and operativeexposure, in Gelberman RH : Operative nerve repair and reconstruction.Lippincott, 1991, pp1255-1272
15 Kim DH, Murovic JA, Kline DG : Brachial plexus injury : mechanisms,surgical treatment and outcomes. J Korean Neurosurg Soc 36 : 177-185, 2004
16 Tender GC, Kline DG : Anterior supraclavicular approach to the brachial plexus. Neurosurgery 58 : ONS-360-ONS-364; discussion ONS-364-ONS-365, 2006
17 Harris M, Tindall SC : Surgical anatomy and exposures of theperipheral nervous system, in Tindall GT, Cooper PR(eds): The practice of neurosurgery Vol 3 : Philadelpbia : Lippincott Williams& Wilkins, 1996, pp2831-2836
18 Bonnel F, Rabischong P : Anatomy and systematization of thebrachial plexus in the adult. Anat Clin 2 : 289-298, 1981   DOI
19 McGillicuddy JE : Surgical anatomy and management of brachialplexus injury, in Neurosurgery Clinics of North America, 1991,pp2860-2863
20 Ahmed-Labib M, Golan JD, Jacques L : Functional outcome ofbrachial plexus reconstruction after trauma. Neurosurgery 61 : 1016-1022; discussion 1022-1023, 2007   DOI   ScienceOn
21 Bertelli JA, Ghizoni MF : Improved technique for harvesting theaccessory nerve for transfer in brachial plexus injuries. Neurosurgery58 : ONS-366-ONS-370; discussion ONS-370, 2006