• Title/Summary/Keyword: Average image ratio

Search Result 270, Processing Time 0.026 seconds

Verification of Extended Source-To-Imager Distance (SID) Correction for Portal Dosimetry

  • Son, Jaeman;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • This study aimed to evaluate and verify a process for correcting the extended source-to-imager distance (SID) in portal dosimetry (PD). In this study, eight treatment plans (four volumetric modulated arc therapy and four intensity-modulated radiation therapy plans) at different treatment sites and beam energies were selected for measurement. A Varian PD system with portal dose image prediction (PDIP) was used for the measurement and verification. To verify the integrity of the plan, independent measurements were performed with the MapCHECK device. The predicted and measured fluence were evaluated using the gamma passing rate. The output ratio was defined as the ratio of the absolute dose of the reference SID (100 cm) to that of each SID (120 cm or 140 cm). The measured fluence for each SID was absolutely and relatively compared. The average SID output ratios were 0.687 and 0.518 for 120 SID and 140 SID, respectively; the ratio showed less than 1% agreement with the calculation obtained by using the inverse square law. The resolution of the acquired EPIDs were 0.336, 0.280, and 0.240 for 100, 120, and 140 SID, respectively. The gamma passing rates with PD and MapCHECK exceeded 98% for all treatment plans and SIDs. When autoalignment was performed in PD, the X-offset showed no change, and the Y-offset decreased with increasing SID. The PD-generated PDIP can be used for extended SID without additional correction.

Identification of Rice Species by Three Side (Top, Side and Front) Images of Brown Rice (현미 세 면(윗면, 측면, 앞면)의 화상을 이용한 품종 판별)

  • Kim, Sang-Sook;Lee, Sang-Hyo;Rhyu, Mee-Ra;Kim, Young-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.473-479
    • /
    • 1998
  • Identification of rice species was attempted by three side (top, side and front) images of brown rice. Nine parameters of each image were area, aspect ratio, maximum diameter, minimum diameter, perimeter, roundness and red (R), green (G) and blue (B) pixel values of an image. Forty rice samples consisted of 19 species used for the study and total 27 image characteristics for a kernel were measured. For calibration and confirmation, 105 and 20 brown rice kernels per each sample were used respectively. For best identification of rice species, 24 image characteristics were selected for discriminant analysis. Average percentages for correct identification of rice species were 84.75% and 84.93% for calibration and confirmation data set, respectively. The highest and lowest percentage for correct identification were 99.05% for Nongan and 50.63% for Hwaseung respectively in calibration data. The confirmation data showed that the correct identification of Nongan or Paalgong was 100%, while that of Hwaseung was 47.62%. The result of the study showed that three side (top, side and front) image of brown rice was not suitable for identification of rice species suggesting that additional techniques are required for better discrimination of rice species.

  • PDF

A Comparative Study of CTDI and the Effective Dose and the SNR according to the Area in the Abdominal CT (복부CT에서 면적에 따른 CTDI와 유효선량 및 SNR의 비교 연구)

  • Choi, Sung-Jun;Kang, Jun-Guk;Kim, Su-In;Kim, Youn-Ho;Lee, Do-Gyeong;Jung, Jin-Gyung;Cho, Ar-A;Jang, Jae-Hyeok;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.245-252
    • /
    • 2015
  • To obtain the best SNR (signal to noise ratio) due to changes in CTDI (computed tomography dose index) made for the purpose of setting the optimum image obtained by reducing the dose in abdominal CT. Abdominal CT scans of 59 patients a $400-499cm^2$ (n = 12), $500-599cm^2$ (n = 21), $600-699cm^2$ (n = 17), $700-799cm^2$ (n = 9) were separated by four groups and the effective dose was used in the Excel to get the area of the patient using the ImageJ program. Patients of CTDI, DLP, SNR, the effective dose were analyzed. Abdominal CT area was increased to 13 mGy in CTDI is 7.3 mGy, DLP to 732 in $394.4mGy{\cdot}cm$, also effective dose was 5.9 mSv increase in 11mSv. SNR is 15 dB was maintained at 12.7. CTDI according to the average of the abdominal area of 8.9 mGy, the average of the DLP was $481.54mGy{\cdot}cm$, the effective dose is calculated to be 7.2 mSV. Effective dose was calculated by multiplying the load factor of DLP in the abdomen showed no statistically significant difference of (p < .05), there was a significant difference in SNR (p > . 05). To improve image quality of abdominal CT scan image in consideration of the CTDI according to the volume of the patient it should be able to reduce the radiation exposure of the patients.

Reducing Dose in SPECT/CT Using Adaptive Statistical Iterative Reconstruction Technique (Adaptive Statistical Iterative Reconstruction 기법을 이용한 Bone SPECT/CT 검사에서 피폭량 감소 방안)

  • Choi, Jin-Wook;Choi, Hyeon-Jun;Park, Chan-Rok;Cho, Sung-Wook;Kim, Jin-Eui;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.134-139
    • /
    • 2014
  • Purpose: Adaptive statistical iterative reconstruction (ASIR) technique is a reconstruction method of CT image using statistical noise modeling which is known to reduce image noise and to preserve image quality despite reducing radiation dose. The aim of this study is to evaluate images using ASIR on bone SPECT/CT which is primarily performed in our hospital. Materials and Methods: We compared the images of applied ASIR (ASIR level: 20-80%) and none ASIR by changing the mA based on 120 kVp, 100 mA using Discovery NM/CT 670 (GE, U.S.A). First, we evaluated attenuation correction in SPECT image by changing the ASIR level using Anthropomorphic phantom. Second, we compared the contrast to noise ratio (CNR), image noise and spatial resolution in CT image using ACR phantom. Third, after selecting the ASIR level applicable patient using lower torso phantom, we examined 2 patients who followed up bone SPECT/CT and we performed blind test. Results: The degree of attenuation correction in SPECT image showed no significant difference between applied ASIR and none ASIR (P>0.05). When applied ASIR, the noise of CT image were reduced at least 17 up to 52% by changing the mA. The CNR of image with ASIR was maintained more than 0.8 at 40 mA (ASIR 60%) while those without ASIR showed 0.42 at standard 40 mA. In comparison of the high contrast object, we distinguished 12 line pairs/cm at 40 mA regardless of appling ASIR. Comparison of the patients image applied ASIR level 60% (40 mA) which found out by spine image of lower torso phantom showed no signigicant difference between applied ASIR and none ASIR in blind test. The CTDIvol and DLP for applied ASIR 60% showed decreased by 60%, 60% on average than using standard mA. Conclusion: The study show that the radiation dose in SPECT/CT using ASIR can be reduced despite degradation of SPECT and CT images. In addition, higher ASIR level could be possibly applied characteristics of SPECT/CT that region of interest is limited to bone.

  • PDF

Magnetic Tunnel Junctions with AlN and AlO Barriers

  • Yoon, Tae-Sick;Yoshimura, Satoru;Tsunoda, Masakiyo;Takahashi, Migaku;Park, Bum-Chan;Lee, Young-Woo;Li, Ying;Kim, Chong-Oh
    • Journal of Magnetics
    • /
    • v.9 no.1
    • /
    • pp.17-22
    • /
    • 2004
  • We studied the magnetotransport properties of tunnel junctions with AlO and AlN barriers fabricated using microwave-excited plasma. The plasma nitridation process provided wider controllability than the plasma oxidization for the formation of MTJs with ultra-thin insulating layer, because of the slow nitriding rate of metal Al layers, comparing with the oxidizing rate of them. High tunnel magnetoresistance (TMR) ratios of 49 and 44% with respective resistance-area product $(R{\times}A) of 3 {\times} 10^4 and 6 {\times} 10^3 {\Omega}{\mu}m^2$ were obtained in the Co-Fe/Al-N/Co-Fe MTJs. We conclude that AlN is a hopeful barrier material to realize MTJs with high TMR ratio and low $R{\times}A$ for high performance MRAM cells. In addition, in order to clarify the annealing temperature dependence of TMR, the local transport properties were measured for Ta $50{\AA} /Cu 200 {\AA}/Ta 50 {\AA}/Ni_{76}Fe_{24} 20 {\AA}/Cu 50 {\AA}/Mn_{75}Ir_{25} 100 {\AA}/Co_{71}Fe_{29} 40 {\AA}/Al-O$ junction with $d_{Al}= 8 {\AA} and P_{O2}{\times}t_{0X}/ = 8.4 {\times} 10^4$ at various temperatures. The current histogram statistically calculated from the electrical current image was well in accord with the fitting result considering the Gaussian distribution and Fowler-Nordheim equation. After annealing at $340^{\circ}C$, where the TMR ratio of the corresponding MTJ had the maximum value of 44%, the average barrier height increased to 1.12 eV and its standard deviation decreased to 0.1 eV. The increase of TMR ratio after annealing could be well explained by the enhancement of the average barrier height and the reduction of its fluctuation.

Comparison Study of Image Quality of Direct and Indirect Conversion Digital Mammography System (직접 및 간접변환 방식의 디지털 유방 X선 촬영시스템의 영상화질 비교 연구)

  • Park, Hye-Suk;Oh, Yu-Na;Jo, Hee-Jeong;Kim, Sang-Tae;Choi, Yu-Na;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.239-245
    • /
    • 2010
  • The purpose of this study is to comprehensively compare and evaluate the characteristics of image quality for digital mammography systems which use a direct and indirect conversion detector. Three key metrics of image quality were evaluated for the direct and indirect conversion detector, the modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), which describe the resolution, noise, and signal to noise performance, respectively. DQE was calculated by using a edge phantom for MTF determination according to IEC 62220-1-2 regulation. The contrast to noise ratio (CNR) was evaluated according to guidelines offered by the Korean Institute for Accreditation of Medical Image (KIAMI). As a result, the higher MTF and DQE was measured with direct conversion detector compared to indirect conversion detector all over spatial frequency. When the average glandular dose (AGD) was the same, direct conversion detector showed higher CNR value. The direct conversion detector which has higher DQE value all over spatial frequency would provide the potential benefits for both improved image quality and lower patient dose in digital mammography system.

A Study on the Customer Shopping Behavior based on the Store Image (점포이미지가 소비자 쇼핑행동에 미치는 영향)

  • Kang, Sung-Joo
    • The Journal of Information Technology
    • /
    • v.7 no.4
    • /
    • pp.89-101
    • /
    • 2004
  • This study, Based on the study theories of up to the present was to a consumer's shopping motive, the process of choice and the theory of a consumer's store choice by his or her preference. It investigates the components of store image referring many thesis from documents of domestic and foreign countries. The major findings of from study an as follows: First, as general characteristics of samples, the component ratio of women is much higher than that of men. As for marital status, married consumers are large in numbers, and for educational back ground, high educated young couples go shopping frequently at department stores. As for ages, consumers under the 30s take great part in, for the occupation, many are housewives and for the average income of a month, under one million won income earners are major consumers. Second, about shopping motive, married ones do it for refreshing themselves, but for singles, they do shopping for the pleasure of bargain sales. The most important reason which influences on the shopping motive is 'pleasure of bargain sales' regardless of all ages. Third, according to the analysis of shopping motive and the characteristics of 15 store images, there are noteworthy differences statistically in shopping motive, attraction and reliance on advertisement, an atmosphere of a store and the degree of crowdedness.

  • PDF

Analysis of the Change in Pattern of Seoul Forest Patch to have used Landsat MSS Data (Landsat Mss Data를 이용한 서울시 산림패취의 패턴 변화분석)

  • Lee, Jong-Sung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.2
    • /
    • pp.240-250
    • /
    • 1998
  • This study is to have attempted to analyze the characteristics of the change in forest landscape pattern of Seoul for 18 years by grasping it through satellite image data on the forest area in Seoul where a rapid change according urbanization and industrialization is going on. On the basis of Landsat MSS data- satellite image data, this writer analyzed the change in the number and size of patch and the mean edge length of each forest land, and the index of patch shape by each year from a landscape -ecological point of view. The results are as follows; First, in the pattern change of the forest patch of Seoul, the highest patch fragmentation area is the forest of the Yangchon-gu district where is decreasing it forest area by 654ha, 511ha, 495ha, 402ha each year from its total size of 742ha in 1979. Second, the change tendency shows that the average forest size decreased at 552.58ha in 1983, 435.03ha in 1988, 396.23ha in 1992, and 379.96ha in 1996. And analysis showed that even in the number of patches, the forest fragmentation phenomenon was presenting by the increase of development disturbance. Third, the mean edge by year was longest at 23,385m in 1979, but it is decreasing continuously. This shows the regular and artificial uniformity of forest landscape by disturbance-effect increase of the built-up development and shows low portion against edge effect by the time-series change like 1979>1983>198>1992>1996. Finally, in the analysis of a shape index indicated by ratio of size and edge, total averages were 2.56, 2.33, 2.17, 2.14, 2.14 each year, so that it is considered that the disturbance and ecological health status against forest landscape can be grasped according to being examined as 1979>1983>1988>1992, 1996 by the time-series change of the landscape.

  • PDF

An Adaptive Block Matching Algorithm Based on Temporal Correlations (시간적 상관성을 이용한 적응적 블록 정합 알고리즘)

  • Yoon, Hyo-Sun;Lee, Guee-Sang
    • The KIPS Transactions:PartB
    • /
    • v.9B no.2
    • /
    • pp.199-204
    • /
    • 2002
  • Since motion estimation and motion compensation methods remove the redundant data to employ the temporal redundancy in images, it plays an important role in digital video compression. Because of its high computational complexity, however, it is difficult to apply to high-resolution applications in real time environments. If we have information about the motion of an image block before the motion estimation, the location of a better starting point for the search of an exact motion vector can be determined to expedite the searching process. In this paper, we present an adaptive motion estimation approach bated on temporal correlations of consecutive image frames that defines the search pattern and determines the location of the initial search point adaptively. Through experiments, compared with DS(Diamond Search) algorithm, the proposed algorithm is about 0.1∼0.5(dB) better than DS in terms of PSNR(Peak Signal to Noise Ratio) and improves as high as 50% compared with DS in terms of average number of search point per motion vector estimation.

A Camera Based Traffic Signal Generating Algorithm for Safety Entrance of the Vehicle into the Joining Road (차량의 안전한 합류도로 진입을 위한 단일 카메라 기반 교통신호 발생 알고리즘)

  • Jeong Jun-Ik;Rho Do-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.4 s.310
    • /
    • pp.66-73
    • /
    • 2006
  • Safety is the most important for all traffic management and control technology. This paper focuses on developing a flexible, reliable and real-time processing algorithm which is able to generate signal for the entering vehicle at the joining road through a camera and image processing technique. The images obtained from the camera located beside and upon the road can be used for traffic surveillance, the vehicle's travel speed measurement, predicted arriving time in joining area between main road and joining road. And the proposed algorithm displays the confluence safety signal with red, blue and yellow color sign. The three methods are used to detect the vehicle which is driving in setted detecting area. The first method is the gray scale normalized correlation algorithm, and the second is the edge magnitude ratio changing algorithm, and the third is the average intensity changing algorithm The real-time prototype confluence safety signal generation algorithm is implemented on stored digital image sequences of real traffic state and a program with good experimental results.