• 제목/요약/키워드: Average Volume Method

검색결과 538건 처리시간 0.028초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

스타이렌 폭로 근로자의 환경중 폭로농도와 생물학적 모니터링에 관한 연구 (Relationship between Environmental Exposure and Biological Monitoring Values in Workers Exposed to Styrene)

  • 백종민;이종영;김정만
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.161-170
    • /
    • 1997
  • 본 연구는 사업장 근로자의 스타이렌 폭로수준과 이에 따른 biological monitoring 농도의 변화를 알기 위하여 시도되었다. 조사대상자는 FRP공장, 함침작업공장, 피막도포작업공장에 종사하는 남자근로자 64명과 여자근로자 44명이며 포집 및 분석기간은 1995년 6월 15일부터 9월 30일까지 였다. 일반적 특성중 연령, 성별, 근무경력, 음주량, 흡연량은 설문지를 이용하였고 신장과 체중은 개인건강기록표를, 스타이렌 환경폭로농도를 알기 위하여는 확산형 포집기를 사용하였으며, 생물학적 감시물질의 폭로수준을 알기 위하여 혈액과 소변을 채취하여 혈중 스타이렌, 요중 mandelic acid(MA)와 phenylglyoxylic acid(PGA)을 분석하였다. 평균폭로농도는 21.0ppm으로 저농도였으며 사업장별로는 선박관련업체가, 작업방법으로는 적층작업이, 작업형태는 주작업에서 가장 높은 폭로를 보였으며 대상자 중 11%가 허용기준 이상으로 폭로되었다. 환경폭로수준과 혈중 스타이렌의 상관성은 0.620이었고 creatinine으로 보정한 phenylglyoxylic acid와는 0.702로 가장 높은 상관성을 보였다. 혈중 스타이렌과 요중 대사산물의 상관관계는 MA+PGA에서 가장 높은 상관성을 보였다. 생물학적 대사산물의 변화를 설명하는 독립변수들 중 환경폭로농도가 가장 중요하였으며 특히 MA와 MA+PGA에서는 성별 역시 중요한 변수였다. 생물학적 대사산물에 대한 독립변수의 설명력은 모두 31% 이상이었으며 그중 혈중 스타이렌은 49.1%로 가장 높았다. 요중 대사산물을 보정여부에 따른 상관성을 본 결과 모두 0.95이상을 보였다. 이상을 종합한 바 스타이렌 취급작업장의 공기중 농도를 측정할 때 확산포집기로도 사용할 수 있으며, 요의 생물학적 지표에서는 비중으로 보정한 경우가 creatinine으로 보정한 것의 대안으로 사용할 수 있고 또한 요중 MA 및 PGA를 이용하여 폭로 근로자의 폭로농도를 예측할 수 있으므로 이를 스타이렌 취급근로자에 적극적인 활용이 필요한 것으로 제시할 수 있다.

  • PDF

PET과 Acetazolamide 부하 $^{123}I-IMP$ 뇌혈류 SPECT를 이용한 혈역학적 부전의 평가 (Evaluation of Hemodynamic Failure with Acetazolamide Challenged $^{123}I-IMP$ Brain SEPCT and PET)

  • 천경아;조인호;원규장;이형우;하야시다 코헤이
    • 대한핵의학회지
    • /
    • 제37권2호
    • /
    • pp.94-102
    • /
    • 2003
  • 목적: 아세타졸아마이드를 이용한 뇌혈류 SPECT는 폐쇄성 뇌혈관질환이 있는 환자에서 혈역학적 부전을 평가 하는데 유용하다. 본 연구는 아세타졸아마이드 부하 $^{123}I-IMP$ SPECT를 실시하여 뇌국소부위의 혈역학적 부전의 정도를 정확히 평가할 수 있는지를 살펴보았다. 대상 및 방법: 뇌혈관 질환이 의심되는 18명의 (남: 16, 여: 2, 평균연령 61세) 환자를 대상으로 하였다. 뇌국소부위의 혈관확장 예비능을평가하기 위하여 아세타졸아마이드 투여후 $^{123}I-IMP$ SPECT를 실시하였다. PET은 SPECT 검사 전후로 2주 이내의 간격을 두고 실시하였으며, 뇌혈류, 산소추출분획, 뇌산소대사율 및 뇌혈액량을 구하였다. 모두 46개의 직사각형의 관심영역 (ROIs)을 4개의 다른 뇌단층면에서 직접그리고 병변 부위의 관심영역내에서의 $^{123}I-IMP$ 섭취와 반대측의 동일영역의 관심영역에서 $^{123}I-IMP$ 섭취비율인 AI 를 구하여 PET 에서 얻어진 자료들과 비교하였다. 결과: 18명의 환자의 414 개의 해부학적 영역에서의 뇌의 혈역학적인 평가는 각 환자의 산소수출분획과 뇌혈류/뇌혈액량에 따라 정상 (n=107), stage I (n=117) 또는 stage II (n=140) 로 나누었다. 혈관 확장 예비능을 나타내는 ${\triangle}AI$ (아세타졸아마이드투여시 AI 값-기저상태의 AI 값) 의 값은 정상, stage I 및 stage II 에서 각각 $-6.25{\pm}7.77%,\;-10.38{\pm}10.41%$$-13.30{\pm}10.51%$으로 세군간에 유의한 차이가 있었다 (p<0.05). 뇌혈관 협착이 있는 대뇌반구에서 ${\triangle}AI$와 뇌혈류량, 산소추출분획 및 뇌혈액량/뇌혈류량의 상관계수는 각각 0.20, -0.28 및 -0.28로 통계적으로 유의한 상관관계를 보였다(p<0.01). 결론: 정상인과 stage I 그리고 stage II 의 혈역학적부전 환자들간의 뇌혈관확장 예비능에 유의한 차이가 있었으며, 이러한 결과로 볼 때 아세타졸아마이드 부하에 대한 국소뇌혈류의 변화는 뇌관류압에 대한 보상적 혈관확장의 정도를 비교적 정확히 반영할 수 있다고 볼 수 있다.

남해 대륙붕 PZ-1 시추공 주변 현무암 대지 구조의 CO2 지중저장용량 평가 (Assessment of CO2 Geological Storage Capacity for Basalt Flow Structure around PZ-1 Exploration Well in the Southern Continental Shelf of Korea)

  • 신승용;강무희;신영재;정순홍
    • 자원환경지질
    • /
    • 제53권1호
    • /
    • pp.33-43
    • /
    • 2020
  • CO2 지중저장은 현재 온실가스 감축을 위한 CCS(Carbon Capture & Storage) 저장기술 중 가장 안정적이고 효과적인 기술로 평가되고 있다. 지중저장 대상 염대수층은 일반적으로 CO2가 초임계상태로 저장될 수 있는 지하 800 m 이상의 심도에 위치하고, 그 상부에 지표로의 CO2 누출을 막는 광역적인 불투수성 덮개암층이 분포해야 한다. 본 연구에서는 남해 대륙붕 탄성파 및 시추공 자료를 해석하여 덮개암으로 활용할 수 있는 현무암층과, 하부 염대수층이 발달하고 있는 현무암 대지 구조를 CO2 지중저장 유망구조로 제시하였다. 연구지역 주입대상 염대수층의 지중저장용량을 평가하기 위해 총 공극률은 시추공 감마 및 음파검층 자료를 이용하여 산출하였으며, 염대수층 구간의 온도/압력 조건을 고려하여 CO2 밀도를 계산하였다. 정확한 주입대상 염대수층의 체적을 산정하기 위해 x, y, z 축 방향으로 일정한 크기를 가지는 3차원 지질 격자 모델을 구성하였고, 염대수층 3차원 공간의 물성 분포를 지구통계학적 기법으로 예측하는 물성 모델링을 수행하여 총 공극률 값을 지질 격자에 할당하였다. U.S. DOE 방법을 이용하여 남해 대륙붕 현무암 대지 구조의 CO2 지중저장용량 평가 결과 평균 약 8,417만 CO2톤(최소 4,207만 ~ 최대 1억 4,379만 CO2톤)이 주입대상 염대수층 구간에 저장 가능한 것으로 예측되었다.

세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향 (Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy)

  • 김선영;이두현;조정근;정도형;김호식;최계숙
    • 대한방사선치료학회지
    • /
    • 제18권1호
    • /
    • pp.1-5
    • /
    • 2006
  • 목 적: 세기조절 방사선치료의 환자별 정도관리는 이온전리함을 이용한 일정 지점에서의 절대 선량 측정과 필름을 이용한 상대 선량측정의 두 단계로 구성된다. 이온전리함을 이용한 절대 선량 측정은 동일한 지점에서 치료계획상의 점선량과 실제 측정 점선량 간의 일치도에 대한 정보를 제공한다. 일반적으로 정확한 점선량을 측정하기 위해 volume이 작은 0.015 cc 이온전리함(pin point chamber, PTW, Germany)을 사용하고 있다. 그러나 이 경우 이온전리함의 볼륨이 작아 선량의 오차가 크게 나타나는 경우도 있어, 적합한 볼륨의 이온전리함 사용이 권고되기도 한다. 따라서 볼륨이 다른 세 가지의 이온전리함을 이용하여 점선량을 측정하여 치료계획상의 점 선량과 비교해 보고, 0.015 cc 이온전리함을 이용한 세기조절 방사선치료에서의 절대 점선량 측정의 유효성을 평가해 보고자 한다. 대상 및 방법: 두경부(Head & Neck) 종양의 세기조절 방사선치료가 요구되는 환자 6명을 대상으로 Sliding-window 방법의 IMRT 치료계획을 수립하였으며 치료기는 21EX(Varian, USA) 선형가속기의 6 MV 광자선을 사용하였다. 측정 조건은 120 millenium MLC를 이용하여 Gantry 0도에서 300 MU/min의 선량률로 선원-이온전리함(source-axis-distance)거리를 100 cm, 고체팬텀의 표면으로부터 5 cm 깊이에 이온전리함을 위치시켰다. 치료계획용 컴퓨터(CAD-Plan, USA)에서 결정된 결과를 0.015 cc(pin point, type 31014, PTW, Germany), 0.125 cc(micro type 31002, PTW, Germany ), 0.6 cc(famer type 30002, PTW, Germany) 전리함에 각각 조사하여 측정치를 비교 분석하였다. 측정점은 선량값의 변화가 상대적으로 적은 선량 저변동 영역(Low-gradient area)에 위치시켰다. 결 과: 각각의 이온전리함을 이용하여 측정한 결과 0.015 cc의 경우 평균 ${\pm}0.91%$, 0.125 cc의 경우 ${\pm}0.52%$, 0.6 cc의 경우 ${\pm}0.76%$로 0.125 cc 이온전리함의 경우가 모든 측정조건에서 가장 적은 오차를 보였다. 결 론: 세기조절 방사선치료에 있어서 선량의 평가는 매우 중요하다. 방사선치료가 정밀해지는 만큼 정확한 선량평가가 이루어져야 한다. 점선량을 평가하기 위해 제작된 0.015 cc 이온전리함은 작은 출력신호와 큰 신호 대 잡음비가 절대 선량 측정 시 선량오차를 발생시키는 큰 요인으로 작용할 수 있다. 반면에 이온전리함의 볼륨이 큰 경우 출력신호가 크므로 정확한 선량을 반영할 수 있으나, 작은 측정점에 이온전리함을 정확히 위치시키기 어려워 절대 점선량을 측정하기 어려운 단점이 있다. 따라서 본 연구의 결과에서 본 바와 같이 세기조절 방사선치료의 절대 점선량 측정에는 오차가 상대적으로 적은 0.125 cc 이온전리함의 사용이 고려되어야 한다.

  • PDF

목편살수여상조를 이용한 축산뇨오수 처리와 목편여재의 물성 및 부착미생물 특성 (Treatment of Animal Wastewater Using Woodchip Trickling Filter System and Physical and Microbial Characteristics of Wood Chip Media)

  • 류종원
    • 한국축산시설환경학회지
    • /
    • 제17권2호
    • /
    • pp.71-80
    • /
    • 2011
  • 본 연구는 pilot 목편칩 살수여상 공정을 운전하면서 저농도 축산뇨오수 처리시에 오수 처리 특성과 부착 미생물의 특성에 관하여 연구하였다. 목편 살수여상 처리 효율과 목편담체의 부착미생물을 분석한 결과는 다음과 같다. 1. 목편담체는 표면구조가 거칠고 여러 형태의 공극을 볼 수 있었고, 목편압축강도는 섬유방향으로 기건상태에서 34.8 N/$mm^2$ 이었고, 비표면적은 0.4123 $m^2$/g, 세공용적은 0.0947 $cm^3$/g 이었다. 2. 목편담체의 단위면적당 부착미생물량은 1.67~5.43 mg/$cm^3$의 분포를 보였고, 제1 목편 살수여상조에서 평균 4,01 mg/$cm^3$, 제2 목편 살수여상조에서 평균 5.05 mg/$cm^3$로 조사되었다. 부착미생물의 건조밀도는 제1 목편 살수여상조에서 평균 0.275 g/$cm^3$, 제2 목편 살수여상조에서 평균 0.245 g/$cm^3$이었다. 목편담체에 부착된 미생물의 생물막 두께는 0.88~4.11 ${\mu}m$의 분포를 이루고, 제1 목편 살수여상조 평균 157 ${\mu}m$, 제2 목편 살수여상조 평균 2.59 ${\mu}m$의 결과를 얻었다. 3. 부착미생물의 균수 측정에서 호기성균은 제1 목편 살수여상조에서 평균 $1.9{\times}10^8$ CFU/ml, 제2 목편 살수여상조에서 평균 $2.6{\times}10^7$ CFU/ml ddjT으며, 혐기성균은 제1 목편 살수여상조에서 평균 $8.5{\times}10^6$ CFU/ml, 제2목편 살수여상조에서 평균 $5.3{\times}10^5$ CFU/ml로 조사되었다. 4. 살수여상 여과수의 $BOD_5$는 원수에서 비교하여 74.5% 제거되었으며 CODcr 제거효율은 51.5%로서 $BOD_5$ 보다 다소 낮았다. T-N 함량은 처리전 844 mg/$\ell$ 에서 살수여상처리 후 325.5 mg/$\ell$ 로 낮아졌다. T-P 함량은 처리전 127.7 mg/$\ell$ 에서 살수여상 처리 후 55.9로 낮아졌다. 질소, 인의 제거효율도 각각 61.4%, 56.2%를 나타내었다.

한국의 농산물 가상수 산정 (Estimation of Crop Virtual Water in Korea)

  • 유승환;최진용;김태곤;임정빈;전창후
    • 한국수자원학회논문집
    • /
    • 제42권11호
    • /
    • pp.911-920
    • /
    • 2009
  • 가상수는 농산물, 가공식품 또는 제품을 만들기 위해서 필요한 물의 총량을 의미한다. 우리나라의 곡물자급율은 27 %에 불과하며, 농산물 수입에 의한 가상수 수입이 다른 나라들에 비해 매우 큰 편에 속하며, 우리나라에 적합한가상수를 산정할 필요가 있다. 본 논문은 Chapagain과 Hoekstra가 제안한 방법을 이용하여, 1991년부터 2007년까지의 연간 농업 가상수 사용량(agricultural virtual water use, AWU)과 작물 1 톤을 생산하기 위하여 필요한 가상수량(virtual water content, VWC)을 산정하는 데 목적을 두고 있다. 가상수 사용량을 산정하기 위하여 44가지 작물에 대해 17년간의 작물 생산량과 재배면적 데이터를 수집하고, FAO Penman-Monteith식을 이용하여 작물소비수량을 산정하였다. 산정 결과를 살펴보면, 농업 가상수 사용량은 151억 $m^3$으로 산정되었고, 점차 그 양이 줄어드는 경향을 보였다. 작물 중 논벼가 가장 많은 양의 농업 가상수를 사용하였고, 전체 농업 가상수 사용량 중 75 %에 해당하는 연간 101억 $m^3$을 사용하였으며, 논벼를 1톤을 생산하기 위해 필요한 가상수량은 1600.1 $m^3$/ton으로 산정되었다. 작물을 생산하는 데 있어 필요한 가상수량이 큰 작물 종류는 채유종실이 가장 큰 값을 나타내었고, 엽채류 및 근채류가 가장 작은 것으로 나타났다. 산정된 원료 작물의 가상수량은 원료 작물과 가공 생산물의 중량비를 이용하여 농산물 가공품이나 축산물 등 2차 생산물의 가상수를 산정할 수 있다. 이에 따라 본 연구에서 산정된 결과는 우리나라의 농업 분야의 물발자국을 산정하는 데 있어서 기초자료로 활용할 수 있을 것으로 기대된다.

섬유성 골 이형성증에서 시행한 골 이식술의 결과 분석 (The Result of Bone Grafting for Fibrous Dysplasia)

  • 정원주;김태성;조환성;윤종필;박일형
    • 대한골관절종양학회지
    • /
    • 제20권2호
    • /
    • pp.74-79
    • /
    • 2014
  • 목적: 섬유성 골 이형성증은 신호전달 G 단백의 alpha 소단위체 유전자 변이에 따른 양성 골격계 질환으로 다양한 임상적 양상을 보인다. 기능적 장애, 구조적 변형를 방지하기 위해 제한적으로 수술을 시행하게 되는데 종양소파술 후 발생한 공동을 메우는 골 이식술이 시행된다. 이 연구에서는 본원에서 시행한 섬유성 골 이형성증 치료로서 자가 해면골 이식술을 시행한 경우와 자가 해면골과 동종골, 동종골만을 사용한 경우를 비교 분석하고자 한다. 대상 및 방법: 1997년4월부터 2013년 10월까지 본원에서 섬유성 골이형성증으로 진단된 58 명 중 수술 후 1년이상 추시 관찰이 가능했던 34명을 대상으로 하였다. 수술 시 평균 연령은 26.7세(범위, 2-57세)이었고, 남자는 13명, 여자는 21명이었다. 자가 골이식은 모두 장골에서 채취한 망상골을 이식하였고, 동종골은 골은행에서 기증받은 뼈를 이식용으로 재처리하여 이용하였다. 자가 해면골만 이식한 경우(I군)는 5예, 자가 해면골과 동종 골, 혹은 동종골만 이식한 경우(II군)가 29예였다. 재발, 이차적 변성 같은 합병증을 확인하기 위해, 주기적인 단순 방사선 촬영으로 관찰하였으며 각 군을 비교하였다. 결과: 섬유성 골이형성의 재발이 4예(11.4%)있었으며, 자가 해면골 이식술 시행한 군(I군; 1예 20%)과 자가해면골과 동종골, 혹은 동종골만을 이식한 경우(II군; 3예, 10.3%) 간의 재발율을 Kaplan-Meier 방법으로 분석한 결과 두군간의 차이가 없었다(p=0.554). 재발한 경우는 모두 소파술 및 자가골이식술을 다시 시행하였으며 재수술 후 재발은 없었다. 낭종 같은 이차적 변성이 확인된 경우가 1예, 병적 골절을 보인 경우 1예가 있었으나, 악성변화를 일으킨 경우는 없었다. 결론: 섬유성 골 이형성증 환자들에게 골이식을 시행한 경우, 자가 해면골 또는 동종 골 이식술을 시행한 양 군에서 재발,병적 골절 같은 합병증의 결과가 의미 있는 차이를 보이지 않았다. 따라서 종양의 부피가 작고 병변의 위치가 체중이 가하지는 부위가 아닐 경우에는 자가 해면골 이식 또한 좋은 방법으로 사료되며 이에 대한 연구가 필요하다.

ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링 (Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System)

  • 한희조;김학진;정대현;조우재;조영열;이공인
    • 생물환경조절학회지
    • /
    • 제29권2호
    • /
    • pp.141-152
    • /
    • 2020
  • 본 연구는 양액 내 존재하는 다량 영양소의 농도를 실시간으로 측정하기 위해 이온 선택 전극 (ISE) 으로 구성된 임베디드 시스템의 개발을 보여준다. NO3, K 및 Ca 이온을 감지하기위한 PVC ISE, H2PO4를 감지하기위한 코발트 전극, 기준 전극, 샘플 용액이 담기는 챔버, 펌프 및 밸브를 사용하여 측정하는 시스템으로 구성된다. 양액 샘플양 조절과 데이터 수집을 위해서 데이터 Due 보드가 사용되었고, 각각의 샘플 측정 전에, 측정 중 발생하는 드리프트를 최소화시키기 위해 2 점 정규화 방법을 사용하였다. PVC 멤브레인을 기반으로 한 NO3 및 K 전극의 농도 예측 성능은 표준 분석기의 결과와 근접한 일치 (R2 = 0.99) 나타내며 만족스러운 결과를 나타냈다. 하지만, Ca II 이온 투과체 제조된 Ca 전극은 고농도 양액 농도에서 Ca 농도를 55 %로 낮게 측정하였다. 코발트 전극 기반 인산 측정은 반복측정 중에 발생한 코발트 전극의 불안정한 신호로 인해 표준 방법과 비교하여 45 ~ 155 mg / L의 인산 농도 범위에서 24.7 ± 9.26 %의 비교적 높은 오차를 나타냈다. 수경 P 감지의 예측 능력을 향상시키기 위해 코발트 전극의 신호 컨디셔닝에 대한 추가 연구가 필요함으로 판단된다.