• 제목/요약/키워드: Auxiliary power system

검색결과 423건 처리시간 0.022초

Flyback Inverter Using Voltage Sensorless MPPT for Photovoltaic AC Modules

  • Ryu, Dong-Kyun;Choi, Bong-Yeon;Lee, Soon-Ryung;Kim, Young-Ho;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1293-1302
    • /
    • 2014
  • A flyback inverter using voltage sensorless maximum power point tracking (MPPT) for photovoltaic (PV) AC modules is presented. PV AC modules for a power rating from 150 W to 300 W are generally required for their small size and low price because of the installation on the back side of PV modules. In the conventional MPPT technique for PV AC modules, sensors for detecting PV voltage and PV current are required to calculate the PV output power. However, system size and cost increase when the voltage sensor and current sensor are used because of the addition of the auxiliary circuit for the sensors. The proposed method uses only the current sensor to track the MPP point. Therefore, the proposed control method overcomes drawbacks of the conventional control method. Theoretical analysis, simulation, and experiment are performed to verify the proposed control method.

Utililty-Interfaced High-Frequency Flyback Transformer Linked Sinewave Pulse Modulated Inverter for a Small Scale Renewable Energy Conditioner

  • Chandhaket, Srawouth;Koninish, Yoshihiro;Nakaoka, Mutsou
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.112-123
    • /
    • 2002
  • This paper presents a novel prototype of the utility AC power interfaced soft-switching sinewave pulse modulated inverter using the high-frequency flyback for the small scale distributed renewable energy power conditioner. The proposed cricuit with a high-frequency isolation link has a funtion of electrical isolation, which is more cost-effective and reliable for the small-scale distributed renwal energy utilization system from a safety point of riew. The discontinuous conduction mode(DCM) operation of the high-frequency flyback transformer is adopted to establish a simple and low-cost circuit configuration and control scheme. For the simplicity, the circuit operating principle is described on the basis of the modified conventional full bridge inverter, whitch is the typical conventional high-frequency full-bridge inverter employing the high requency flyback transformer to eanble the effictive function of the electrical isolation. Than, the new circuit topology of the unility-interfaced soft-switching sinewave pulse modulated inverter using IGBTs is proposed. The proposed cricuit topology is additionally composed of the auxiliary power regenerating snubber cricuits, which are also mathematically analyzed for the parameter desigen settings. Finally, the performance of the propose inverter is evaluated on the basis of computer-aid simulation. It is noted that the sinewave pulse modulated output current of the inverter is synchronous to the AC main voltage.

On the Design of Power Supply System for Freight Train Reefer Container Based on Simulation

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Hwang, Jaemin;Chae, Uri
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권3호
    • /
    • pp.249-257
    • /
    • 2022
  • In recent years, if we order food by easily accessing the online market with our smartphone, we can receive the product in a fresh state at dawn the next day. Cold chain is an industry that can create high added value because it has both the characteristics of general logistics and sensitivity to temperature. Based on the electrical specifications derived from the reefer container capacity requirement investigation, we proved that power supply to up to 33 reefer containers can be made by using three additional auxiliary power supplies which are applied for freight trains in Korea. In this paper, we conducted a research on a design of power supply system for freight train reefer container based on simulation as a basic research necessary for low-temperature distribution and cold chain construction based on the reefer container railroad. Consequently, the simulation was conducted using the three-phase inverter diagram in PSIM and the SVPWM (3-harmonic injection method) control technique, and it was verified that the required power voltage was satisfied with 622Vdc, which is lower than the input voltage of general SPWM of 718Vdc. The details of this paper could be used as a foundational study for constructing cold chains based on a reefer container dedicated to freight trains in the future.

동시최적화 설계기법을 이용한 항만용 크레인의 흔들림 제어계 설계 (An Anti-Sway Control System Design Based on Simultaneous Optimization Design Approach)

  • 김영복;문덕홍;양주호;채규훈
    • 한국해양공학회지
    • /
    • 제19권3호
    • /
    • pp.66-73
    • /
    • 2005
  • The sway motion control problem of a container hanging on the trolley is considered in this paper. In the container crane control problem, the main issue involves suppressing the residual swing motion of the container at the end of acceleration, during deceleration, or for an unexpected disturbance input. For this problem, in general, many trolley motion control strategies are introduced and applied. In this paper, we introduce and synthesize a swing motion control system, in which a small auxiliary mass is installed on the spreader. In this control system, the actuator reacting against the auxiliary mass applies inertial control forces to the container to reduce the swing motion in the desired manner. In many studies, the controllers used to suppress the vibration have been synthesized for the given mathematical model of plants. In many cases, the designers have not been able to utilize the degree of freedom to adjust the structural parameters for the control object. To overcome this problem, so called "Structure/Control Simultaneous Method" is used. From this, in this paper the simultaneous design method is used to achieve optimal system performance. And the experimental result shows that the proposed control strategy is useful, to the case of that the controlled system is exposed to the uncertainties and, robust to disturbances like wind.

Velocity Controller Design for Fish Sorting Belt Conveyor System using M-MRAC and Projection Operator

  • Nguyen, Huy Hung;Tran, Minh Thien;Kim, Dae Hwan;Kim, Hak Kyeong;Kim, Sang Bong
    • 동력기계공학회지
    • /
    • 제21권4호
    • /
    • pp.42-50
    • /
    • 2017
  • A velocity controller using a modified model reference adaptive controller (M-MRAC) and a projection operator for a fish sorting belt conveyor system with uncertainty parameters, input saturation and bounded disturbances is proposed in this paper. To improve the tracking performance and robustness of the proposed controller in the presence of bounded disturbances, the followings are done. Firstly, the reference model for the conventional model reference adaptive controller (CMRAC) is replaced by a modified reference model for a M-MRAC to reduce unexpected high frequency oscillation in control input signal when the adaptation rate is increased. Secondly, estimated parameters in an adaptive law are varied smoothly under bounded external disturbances and a projection operator is utilized in an adaptive law for the proposed M-MRAC controller to be robust. Thirdly, an auxiliary error vector is introduced for compensating the error dynamics of the system when the saturation input occurs. Finally, the experimental results are shown to verify the better effectiveness and performance of the proposed controller under the bounded disturbance and saturated input than that of a CMRAC.

보조동력장치 회전자 유동 및 출력특성에 관한 연구 (A Study on the Flow and Power Characteristics of Rotor in the APU)

  • 이중섭;정인국;윤지훈;서정세;이태의
    • 한국생산제조학회지
    • /
    • 제20권6호
    • /
    • pp.805-810
    • /
    • 2011
  • Recently, Use of Auxiliary power unit(APU) is increasing by growing demand for improvement of insufficient electric power and installation of emergency generation devices in military tracked vehicles and civil markets. And the trend is that the units are demanded for smaller size, lighter weight and higher output power, etc to suit consumer demands. To achieve these, it is essential to develop high performance system. Therefore, in this study, it was conducted in numerical analysis to investigate flow characteristics of rotor in APU generator. Also output performance of APU applied on the rotor is analyzed by experimental method. As the result, higher rotating speed of rotor caused high air flow rate at suction and it leads to linear increase of discharging flow rate. The maximum theoretical power was achieved at 12 $m^3$/min of flow rate and, at that time, output power of generator was about 7.825 kW. Also, it can be confirmed the stabilization of output performance is achieved in about 2 seconds by experiment.

현재 기상 정보의 이동 평균을 사용한 태양광 발전량 예측 (Use of the Moving Average of the Current Weather Data for the Solar Power Generation Amount Prediction)

  • 이현진
    • 한국멀티미디어학회논문지
    • /
    • 제19권8호
    • /
    • pp.1530-1537
    • /
    • 2016
  • Recently, solar power generation shows the significant growth in the renewable energy field. Using the short-term prediction, it is possible to control the electric power demand and the power generation plan of the auxiliary device. However, a short-term prediction can be used when you know the weather forecast. If it is not possible to use the weather forecast information because of disconnection of network at the island and the mountains or for security reasons, the accuracy of prediction is not good. Therefore, in this paper, we proposed a system capable of short-term prediction of solar power generation amount by using only the weather information that has been collected by oneself. We used temperature, humidity and insolation as weather information. We have applied a moving average to each information because they had a characteristic of time series. It was composed of min, max and average of each information, differences of mutual information and gradient of it. An artificial neural network, SVM and RBF Network model was used for the prediction algorithm and they were combined by Ensemble method. The results of this suggest that using a moving average during pre-processing and ensemble prediction models will maximize prediction accuracy.

MRAS를 이용한 유도전동기의 파라미터 온라인 추정에 관한 연구 (A Study on Parameter On-line Estimation of Induction Motor using MRAS)

  • 윤인식;변성훈;김경서
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.188-191
    • /
    • 2002
  • This paper presents a method for on-line estimation of rotor time constant of induction motor. The proposed method applies a model reference adaptive system(MRAS) using rotor flux vector. The MRAS consists of two independent observers to estimate the rotor flux vector; one based on voltage equations of rotor flux vector, the other based on current equations of them. The MRAS utilizes concept of auxiliary variables to normalize observer output and decrease high-frequency components of its input. Experimental results verify the validity and usefulness of proposed method

  • PDF

5kW 급 주택용 고분자 연료전지 시스템 (Development of the 5kW Class Polymer Electrolyte Fuel Cell System for Residential Power Generation)

  • 양태현;박구곤;윤영기;이원용;윤왕래;김창수
    • 한국수소및신에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.35-45
    • /
    • 2003
  • Polymer electrolyte fuel cells(PEFC) have been considered to be a suitable candidate for residential, portable and mobile applications, due to their high efficiency and power density, even at low operating temperature. KIER developed a 5kW class PEFC system for residential application and operated the system for over 1,000 hours. To develop a 5kW PEFC system, performance of a cell was improved through successive tests of single cell of small and large area. Fabrication of three 2,5 kW class stacks, design and fabrication of natural gas reformer, design of auxiliary equipments such as DC/DC converter, DC/AC inverter and humidifying units were carried out along with integration of components, operation and evaluation of total system. During the development period from 1999 to 2001, MEA(membrane electrode assembly) fabrication technologies, design and fabrication technologies for separators, stacking technologies and so on were developed, thereby providing basis for developing stacks of higher efficiency and power density in the future. Experience of development of natural gas reformer opened possibilities to use various kinds of fuels. Main results obtained from the development of a 5kW class PEFC system for residential application are summarized.

태양광 발전 시스템을 위한 무접점 전원장치 (A Contact-less Power Supply for Photovoltaic Power Generation System)

  • 이현관;공영수;김윤호;이기식;강성인;정봉근;김은수
    • 전력전자학회논문지
    • /
    • 제11권3호
    • /
    • pp.216-223
    • /
    • 2006
  • 태양광 발전 시스템을 위한 무접점 변압기 적용 고효율 Full-bridge LLC 공진컨버터를 제안하였다. 제안된 LLC 공진컨버터는 직렬 커패시터와의 직렬공진을 위해 무접점 변압기의 누설인덕턴스와 자화인덕턴스를 이용하였다. 제안된 LLC 공진컨버터는 공진주파수 보다 높은 스위칭영역에서 연속 공진전류로 동작하는 기존 직렬공진 컨버터와는 달리 공진주파수 아래의 좁은 주파수 범위에서 불연속 공진전류로 동작한다. 이러한 불연속모드 공진전류 때문에 제안된 컨버터는 어떤 보조회로 없이 무접점 변압기 1차측 주스위칭 소자의 영 전압 스위칭(ZVS)과 2차측 다이오드의 영 전류 스위칭(ZCS)을 얻을 수 있고, 높은 전압이득특성을 갖는다. 본 논문에서는 무접점 변압기 적용 Full-bridge LLC 공진컨버터를 이용한 무접점 전원장치에 대한 이론적 해석 및 시뮬레이션을 통해 150W급 시제품을 제작하여 태양광 발전 전원시스템에 적용 실험한 결과를 서술했다.