• 제목/요약/키워드: Auxiliary power system

검색결과 424건 처리시간 0.024초

보조 동력장치용 서보밸브 유효 오리피스 면적의 칼만필터 추정 (Kalman Filter Estimation of the Servo Valve Effective Orifice Area for a Auxiliary Power Unit)

  • 장지팡;김춘택;정헌술
    • 유공압시스템학회논문집
    • /
    • 제4권4호
    • /
    • pp.1-7
    • /
    • 2007
  • Flow rate is one of the important variables for precise motion control and detection of the faults and fluid loss in many hydraulic components and systems. But in many cases, it is not easy to measure it directly. The orifice area of a servo valve by which the fluid flows is one of key factors to monitor the flow rate. In this paper, we have constructed an estimation algorithm for the effective orifice area by using the model of a servo valve cylinder control system and Kalman filter algorithm. Without geometry information about the servo valve, it is shown that the effective orifice area can be estimated by using only displacement and pressure data corrupted with noise. And the effect of the biased sensor data and system parameter errors on the estimation results are discussed. The paper reveals that sensor calibration is important in accurate estimation and plausible parameter data such as oil bulk modulus and actuator volume are acceptable for the estimation without any error. The estimation algorithm can be used as an useful tool for detecting leakage, monitoring malfunction and/or degradation of the system performance.

  • PDF

Performance Evaluation of 2-Dimensional Light Source using Mercury-free Flat Fluorescent Lamps for LCD Backlight Applications

  • Park, Joung-Hu;Cho, Bo-Hyung;Lee, Ju-Kwang;Whang, Ki-Woong
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.164-172
    • /
    • 2009
  • Recently, 2-dimensional flat light sources have been attracting much attention for its use in LCD backlight applications because of its high luminous efficiency and uniformity. A long-gap discharge, mercury-tree flat fluorescent lamp has been developed, which shows a high brightness ($>5000\;cd/m^2$) and high luminous efficacy (60 lm/W). Additionally, it has a wide operating margin and stable driving condition with the aid of an auxiliary electrode. For driving the lamp, a narrow pulse power to maintain the glow discharge state is required. Since there has been no research for this kind of lamp driving, this paper proposes a newly developed short-pulse, high-voltage lamp-driving scheme. The proposed lamp system uses a ballast with a coupled-inductor in order to raise the short pulse voltage up to the lamp ignition level and to obtain energy-recovery action during the glow discharge mode. The operation principles are presented and also the system performances such as the lighting efficiency, spatial and angular uniformities are evaluated by hardware experiments. The results show that the proposed lighting system is a good candidate for the next-generation of LCD backlight systems.

스팀터빈용 래비린스 실의 누설량 규명을 위한 공기상사 실험 및 해석 (Air Similarity Test and Analysis of Steam Turbine Labyrinth Seal for Leakage Verification)

  • 안상규;김승종;이용복;김창호;하태웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1149-1149
    • /
    • 2006
  • The leakage characteristic is an important factor in power plant. However, most of power plant have efficiency problem which is occurred leaking between high pressure steam turbine axle and stator. The labyrinth seal which is used between the main turbine axle and stator in the power plant. Because it is able to be non-contact seal and it is minimize clearance to decrease the leakage. But its actual system is too huge to experiment. Therefore, most steam turbine seal performance tests were conducted by air similarity test. This paper described a test facility and program for air similarity test of high pressure steam turbine seal. A test facility has been designed and built to evaluate leakage verification of labyrinth seal. The test facility consist of air compressor, anti-swirl labyrinth seal for 1/3 air similarity model, pressure transducer, air flow measure system, instrumentation and auxiliary system. For evaluation of steam turbine seal performance, the air similarity test of labyrinth seal leakage verification was conducted and we compared experiment data and analysis result.

  • PDF

보조동력장치 연료 공급용 서보밸브 토크모터의 기초 수치모사 연구 (Priliminary Numerical Simulation of the Torque Motor for a Servo Valve in the Fuel Supply System of APU)

  • 장세명;정헌술;장강원;양인영;이원중
    • 유공압시스템학회논문집
    • /
    • 제6권2호
    • /
    • pp.1-6
    • /
    • 2009
  • The APU(Auxiliary Power Unit) needs a set of complex pipeline for the fuel supply system where some of the main valves controlling the flow rate consist of the servo valve worked with a torque motor. The input electric current produces an induced magnetic field almost perpendicular to the background magnetic filed generated by fixed permanent magnets. The induced torque deforms the tubular bushing, and directly rotates an armature, which can open and close the valve. In this study, we start from a basic analytic model using a simple electro-magneto-statics, and expand our model to the three-dimensional one computationally applying a commercial code named COMSOL. The result is compared with each other, and reasonable numerical data are obtained for the dynamic behavior and multi-physics system.

  • PDF

가정용 ESS를 고려한 하이브리드 PCS (A Hybrid PCS Considering on a Residential Energy Storage System)

  • 정두용;김지환;최성촌;이수원;한희민;원충연
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.63-69
    • /
    • 2013
  • In recent years, technology for storing a preliminary power or a surplus of photovoltaic energy is required. This technique, as well as store a preliminary energy and improve the reliability of the gird safety. This system can plan a efficient power generation through the flexibility of the power supply from the perspective of not only provider but also user. Accordingly, the realization of the smart grid can be expected. This paper proposes a hybrid PCS using a photovoltaic and a lithium-polymer battery with the characteristics of high density energy. The main energy source of a hybrid PCS is a photovoltaic, grid and the auxiliary energy source is a lithium-polymer battery. The operation of a proposed system in this paper is verified with simulation and experimental results.

도시철도용 에너지저장시스템 에너지 절감을 현장시험 (Field Test of Energy Storage System on Urban Transit System)

  • 이한민;김길동;안천헌;김영규;김태석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1461-1467
    • /
    • 2009
  • The electric railway is a clean and energy saving system, because it requires relatively less energy than automobiles by transporting the same passengers or goods. Six thousands of vehicles are operated on Korean urban transit system. This system is 95% of regeneration system. Especially, the VVVF-Inverter vehicle has a merit of the highest regeneration rate. Energy consumption is 90% for traction and 10% for auxiliary supply. Braking energy is about 40% of energy consumption. Up to 40% of the tractive power of vehicles capable of returning energy to the power supply can be regenerated during braking and that this energy can be used to feed vehicles which are accelerating at the same time. The energy generated by braking vehicle would simply be converted into waste heat by its braking resistors if no other vehicle is accelerating at exactly the same time. Such synchronized braking and accelerating can not be coordinated, the ESS(energy storage system) stores the energy generated during braking and discharges it again when a vehicle accelerates. This paper presents field tests about the energy saving rate of the developed ESS. when the ESS is on/off, energy saving rate of the ESS is tested. The verification test in the field focused on energy saving.

  • PDF

Development of Simplified DNBR Calculation Algorithm using Model-Based Systems Engineering Methodology

  • Awad, Ibrahim Fathy;Jung, Jae Cheon
    • 시스템엔지니어링학술지
    • /
    • 제14권2호
    • /
    • pp.24-32
    • /
    • 2018
  • System Complexity one of the most common cause failure of the projects, it leads to a lack of understanding about the functions of the system. Hence, the model is developed for communication and furthermore modeling help analysis, design, and understanding of the system. On the other hand, the text-based specification is useful and easy to develop but is difficult to visualize the physical composition, structure, and behaviour or data exchange of the system. Therefore, it is necessary to transform system description into a diagram which clearly depicts the behaviour of the system as well as the interaction between components. According to the International Atomic Energy Agency (IAEA) Safety Glossary, The safety system is a system important to safety, provided to ensure the safe shutdown of the reactor or the residual heat removal from the reactor core, or to limit the consequences of anticipated operational occurrences and design basis accidents. Core Protection Calculator System (CPCS) in Advanced Power Reactor 1400 (APR 1400) Nuclear Power Plant is a safety critical system. CPCS was developed using systems engineering method focusing on Departure from Nuclear Boiling Ratio (DNBR) calculation. Due to the complexity of the system, many diagrams are needed to minimize the risk of ambiguities and lack of understanding. Using Model-Based Systems Engineering (MBSE) software for modeling the DNBR algorithm were used. These diagrams then serve as the baseline of the reverse engineering process and speeding up the development process. In addition, the use of MBSE ensures that any additional information obtained from auxiliary sources can then be input into the system model, ensuring data consistency.

Implementation of Non-Contact Gesture Recognition System Using Proximity-based Sensors

  • Lee, Kwangjae
    • 반도체디스플레이기술학회지
    • /
    • 제19권3호
    • /
    • pp.106-111
    • /
    • 2020
  • In this paper, we propose the non-contact gesture recognition system and algorithm using proximity-based sensors. The system uses four IR receiving photodiode embedded on a single chip and an IR LED for small area. The goal of this paper is to use the proposed algorithm to solve the problem associated with bringing the four IR receivers close to each other and to implement a gesture sensor capable of recognizing eight directional gestures from a distance of 10cm and above. The proposed system was implemented on a FPGA board using Verilog HDL with Android host board. As a result of the implementation, a 2-D swipe gesture of fingers and palms of 3cm and 15cm width was recognized, and a recognition rate of more than 97% was achieved under various conditions. The proposed system is a low-power and non-contact HMI system that recognizes a simple but accurate motion. It can be used as an auxiliary interface to use simple functions such as calls, music, and games for portable devices using batteries.

병렬제어를 적용한 8kW급 영전압/영전류 풀 브릿지 DC-DC 컨버터 개발 (Development of 8kW ZVZCS Full Bridge DC-DC Converter by Parallel Operation)

  • 노민식
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.400-408
    • /
    • 2007
  • 본 논문에서의 병렬제어를 이용한 8kW급 대용량 영전압/영전류 풀 브릿지 DC-DC 컨버터의 개발 결과를 보인다. 본 논문에서는 효율적인 시스템 구성을 위해 4-병렬 단위 모듈 운전을 제안한다. 각 단위모듈은 위상 천이 풀 브릿지를 채택하고, ZVZCS 운전을 위해 간단한 보조 회로를 2차측에 추가하였다. ZCS를 위한 보조 회로 동작 로직은 환류 모드 구간에서 1차측 전류를 제거하도록 구현하였다. 또한 병렬 운전시의 출력 전류의 균등 제어를 위해 위상천이로직을 활용한 Charge Control 방식을 적용하였다. 전압 제어기는 DSP TMS320LF2406을 활용하여 4 모듈의 출력전류 및 출력전압을 A/D로 입력받아 구현하였다. 개발된 컨버터는 차량에 설치되는 고속 발전기용 전력 변환기에 장착되었으며, 구축된 모니터링 시스템으로 고속 발전기의 실제 운전 조건에서 데이터를 획득하여, 분석을 통해 그 성능을 입증하였다.

A New Photovoltaic System Architecture of Module-Integrated Converter with a Single-sourced Asymmetric Multilevel Inverter Using a Cost-effective Single-ended Pre-regulator

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.222-231
    • /
    • 2017
  • In this paper, a new architecture for a cost-effective power conditioning systems (PCS) using a single-sourced asymmetric cascaded H-bridge multilevel inverter (MLI) for photovoltaic (PV) applications is proposed. The asymmetric MLI topology has a reduced number of parts compared to the symmetrical type for the same number of voltage level. However, the modulation index threshold related to the drop in the number of levels of the inverter output is higher than that of the symmetrical MLI. This problem results in a modulation index limitation which is relatively higher than that of the symmetrical MLI. Hence, an extra voltage pre-regulator becomes a necessary component in the PCS under a wide operating bias variation. In addition to pre-stage voltage regulation for the constant MLI dc-links, another auxiliary pre-regulator should provide isolation and voltage balance among the multiple H-bridge cells in the asymmetrical MLI as well as the symmetrical ones. The proposed PCS uses a single-ended DC-DC converter topology with a coupled inductor and charge-pump circuit to satisfy all of the aforementioned requirements. Since the proposed integrated-type voltage pre-regulator circuit uses only a single MOSFET switch and a single magnetic component, the size and cost of the PCS is an optimal trade-off. In addition, the voltage balance between the separate H-bridge cells is automatically maintained by the number of turns in the coupled inductor transformer regardless of the duty cycle, which eliminates the need for an extra voltage regulator for the auxiliary H-bridge in MLIs. The voltage balance is also maintained under the discontinuous conduction mode (DCM). Thus, the PCS is also operational during light load conditions. The proposed architecture can apply the module-integrated converter (MIC) concept to perform distributed MPPT. The proposed architecture is analyzed and verified for a 7-level asymmetric MLI, using simulation results and a hardware implementation.