• 제목/요약/키워드: Auxiliary port

검색결과 27건 처리시간 0.03초

보조 흡입구가 장착된 왕복동 압축기의 성능 분석 (Performance of a Reciprocating Compressor Equipped with Auxiliary Port)

  • 이용호;김현진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.163-170
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

  • PDF

보조 흡입구가 장착된 왕복동 압축기의 성능 분석 (Performance of a Reciprocating Compressor Equipped with Auxiliary Port)

  • 이용호;김현진
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.637-644
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

디스플레이 포트를 위한 고속 보조 채널 설계 (Fast Auxiliary Channel Design for Display Port)

  • 진현배;문용환;장지훈;김태호;송병철;강진구
    • 전기전자학회논문지
    • /
    • 제15권2호
    • /
    • pp.113-121
    • /
    • 2011
  • 본 논문은 디스플레이포트의 보조채널에서 고속 데이터 전송을 할 수 있는 고속 양방향 보조 채널을 구성하기 위한 새로운 송 수신기 구조를 제안하고 적용에 대해 서술하였다. 제안된 고속 보조 채널은 저속 전송에서 맨체스터 인코딩을 사용하여 1Mbps대역폭을, 고속 전송에서 8B/10B인코딩 방식을 사용하여 720Mbps의 대역폭을 지원한다. 맨체스터 전송을 사용하여 고속 보조채널 및 메인링크의 링크 서비스 및 디바이스 서비스를 위한 저속 보조채널 블록을 제안하고, 8B/10B인코딩 방식을 통하여 보조채널을 통한 고속 데이터 전송을 위한 블록을 제안한다. 또한 데이터 패킷 구조와 데이터 전송방식에 대하여 정의하였다. 설계된 시스템은 Verilog HDL로 설계 되었으며, 고속 보조채널 송 수신기는 Xilinx Vertex4 FPGA을 사용하여 합성한 결과 7,648개의 LUTs와 6,020개의 registers를 사용 하였으며, 최대 동작 속도는 203MHz의 성능을 확인 하였다.

Analysis and Design of a Three-port Flyback Inverter using an Active Power Decoupling Method to Minimize Input Capacitance

  • Kim, Jun-Gu;Kim, Kyu-Dong;Noh, Yong-Su;Jung, Yong-Chae;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.558-568
    • /
    • 2013
  • In this paper, a new decoupling technique for a flyback inverter using an active power decoupling circuit with auxiliary winding and a novel switching pattern is proposed. The conventional passive power decoupling method is applied to control Maximum Power Point Tracking (MPPT) efficiently by attenuating double frequency power pulsation on the photovoltaic (PV) side. In this case, decoupling capacitor for a flyback inverter is essentially required large electrolytic capacitor of milli-farads. However using the electrolytic capacitor have problems of bulky size and short life-span. Because this electrolytic capacitor is strongly concerned with the life-span of an AC module system, an active power decoupling circuit to minimize input capacitance is needed. In the proposed topology, auxiliary winding defined as a Ripple port will partially cover difference between a PV power and an AC Power. Since input capacitor and auxiliary capacitor is reduced by Ripple port, it can be replaced by a film capacitor. To perform the operation of charging/discharging decoupling capacitor $C_x$, a novel switching sequence is also proposed. The proposed topology is verified by design analysis, simulation and experimental results.

A Study on the Reasonable Service Charges for Incheon North Port(berth 3) under the Private Investment Project

  • Park, Jin-Hee
    • 한국항해항만학회지
    • /
    • 제28권7호
    • /
    • pp.601-608
    • /
    • 2004
  • Recently, port development has been actively in progress through a private investment project. Incheon North Port functions as an auxiliary port for Incheon Port to solve its chronic demurral and freight congestion and to treat materials such as wood, iron material, feed materials. Service charges is one of important factors in the port choice to treat general goods. In general, service charges can be calculated by two methods such as cost accounting method and market price method. This study will review the characteristics of the Incheon North Port (berth 3), which is under the progress of the private investment project and estimate the reasonable service charges for general goods on the basis of market price. This will help a concessionaire to maximize the operation efficiency.

야드 크레인의 컨테이너 흔들림 제어에 관한 연구 (A Study on Sway Control of Containers of Yard Crane)

  • 박찬훈;박경택;김두형;신영재
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 춘계학술대회논문집
    • /
    • pp.64-71
    • /
    • 2000
  • Yard cranes are very useful equipments for handling of heavy containers. But rope-driven yard cranes must have a little of sway and skew motion because ropes are passive mechanical device. So many researches have been concentrated on anti-sway algorithm controlling trolley speed. These approaches require sway angle. But it is very difficult to know sway angle and its derivative. Therefore control algorithm of trolley speed is not practical in general. On the contrary, control strategy using auxiliary rope is very useful to sway control of yard crane because rope length is shorter than quay-side container cranes. In this paper, we derive equations of motion of trolley system which have anti-sway controller to use auxiliary rope. And we propose the control strategy and analyse the behavior of the proposed system.

  • PDF

야드 크레인의 컨테이너 흔들림 제어에 관한 연구 (A Study on Sway Control of Containers of Yard Crane)

  • 박찬훈;박경택;김두형;신영재
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 추계학술대회논문집
    • /
    • pp.143-151
    • /
    • 2000
  • Yard cranes are very useful equipments for handling of heavy containers. But rope-driven yard cranes must have a little of sway and skew motion because ropes are passive mechanical device. So many researches have been concentrated on anti-sway algorithm controlling trolley speed. These approaches require sway angle. But it is very difficult to know sway angle and its derivative. Therefore control algorithm of trolley speed is not practical in general. On the contrary, control strategy using auxiliary rope is very useful to sway control of yard crane because rope length is shorter than quay-side container cranes. In this paper, we derive equations of motion of trolley system which have anti-sway controller to use auxiliary rope. And we propose the control strategy and analyse the behavior of the proposed system.

  • PDF

Partial optional randomized response technique with calibration weighting to adjust non-response in successive sampling

  • Priyanka, Kumari;Trisandhya, Pidugu;Kumar, Ajay
    • Communications for Statistical Applications and Methods
    • /
    • 제28권5호
    • /
    • pp.493-510
    • /
    • 2021
  • The present article endeavours to develop partial optional randomized - response technique (PORT) to deal with sensitive issues in presence of non-response in successive sampling. Calibration techniques have been embedded with PORT to estimate sensitive population mean at current move in two move successive sampling in presence of non-response. Optimum calibration weights are computed at each move with the aid of constraints based on auxiliary information. Detailed properties of the proposed estimators have been discussed. Possible cases in which non-response may creep at two moves has been explored. The proposed technique has been compared with the modified existing technique. Simulation results indicate that the proposed technique is more efficient than existing, modified one. Suitable recommendations are forwarded.

A Link Layer Design for DisplayPort Interface

  • Jin, Hyun-Bae;Yoon, Kwang-Hee;Kim, Tae-Ho;Jang, Ji-Hoon;Song, Byung-Cheol;Kang, Jin-Ku
    • 전기전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.297-304
    • /
    • 2010
  • This paper presents a link layer design of DisplayPort interface with a state machine based on packet processing. The DisplayPort link layer provides isochronous video/audio transport service, link service, and device service. The merged video, audio main link, and AUX channel controller are implemented with 7,648 LUTs(Loop Up Tables), 6020 register, and 821,760 of block memory bits synthesized using a FPGA board and it operates at 203.32MHz.

새로운 전기 자동차 온보드 충전기용 3-포트 컨버터 (A Novel Three-Port Converter for the On-Board Charger of Electric Vehicles)

  • 사기르 아민;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.111-112
    • /
    • 2017
  • This paper presents a novel three-port converter for the OnBoard Charger of Electric Vehicles by using an impedance control network. The proposed concept is suitable for charging a main battery and an auxiliary battery of an electric vehicle at the same time due to its power handling capability of the converter without additional switches. The power flow is managed by the phase angle (${\Theta}$) between the ports whereas voltage at each port is controlled by the asymmetric duty cycle and the phase shift (${\Phi}$) between the inverter lags controlled by the impedance control network. The proposed system has a capability of achieving zero voltage switching (ZVS) and zero current switching (ZCS) at all the switches over the wide range of input voltage, output voltage and output power. The feasibility of the proposed system is verified by the PSIM simulation.

  • PDF