• Title/Summary/Keyword: Auxiliary port

Search Result 27, Processing Time 0.031 seconds

Performance of a Reciprocating Compressor Equipped with Auxiliary Port (보조 흡입구가 장착된 왕복동 압축기의 성능 분석)

  • Lee, Yong-Ho;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.163-170
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

  • PDF

Performance of a Reciprocating Compressor Equipped with Auxiliary Port (보조 흡입구가 장착된 왕복동 압축기의 성능 분석)

  • Lee, Yong-Ho;Kim, Hyun-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.637-644
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

Fast Auxiliary Channel Design for Display Port (디스플레이 포트를 위한 고속 보조 채널 설계)

  • Jin, Hyun-Bae;Moon, Yong-Hwan;Jang, Ji-Hoon;Kim, Tae-Ho;Song, Byung-Cheol;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.113-121
    • /
    • 2011
  • This paper presents the design of a fast auxiliary channel bus for DisplayPort 1.2 interface. The fast auxiliary channel supports Manchester transactions at 1Mbps and fast auxiliary transactions at 780Mbps. The Manchester transaction is used for managing the main link and auxiliary channel and the fast auxiliary transaction is for data transfer via the auxiliary channel. Simplified serial bus architecture is proposed to be implemented in fast auxiliary channel. The fast auxiliary channel transmitter and receiver are implemented with 7,648 LUTs and 6,020 slice register synthesized in Xilinx Vertex4 FPGA and can be operated at 72MHz to support 720Mbps.

Analysis and Design of a Three-port Flyback Inverter using an Active Power Decoupling Method to Minimize Input Capacitance

  • Kim, Jun-Gu;Kim, Kyu-Dong;Noh, Yong-Su;Jung, Yong-Chae;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.558-568
    • /
    • 2013
  • In this paper, a new decoupling technique for a flyback inverter using an active power decoupling circuit with auxiliary winding and a novel switching pattern is proposed. The conventional passive power decoupling method is applied to control Maximum Power Point Tracking (MPPT) efficiently by attenuating double frequency power pulsation on the photovoltaic (PV) side. In this case, decoupling capacitor for a flyback inverter is essentially required large electrolytic capacitor of milli-farads. However using the electrolytic capacitor have problems of bulky size and short life-span. Because this electrolytic capacitor is strongly concerned with the life-span of an AC module system, an active power decoupling circuit to minimize input capacitance is needed. In the proposed topology, auxiliary winding defined as a Ripple port will partially cover difference between a PV power and an AC Power. Since input capacitor and auxiliary capacitor is reduced by Ripple port, it can be replaced by a film capacitor. To perform the operation of charging/discharging decoupling capacitor $C_x$, a novel switching sequence is also proposed. The proposed topology is verified by design analysis, simulation and experimental results.

A Study on the Reasonable Service Charges for Incheon North Port(berth 3) under the Private Investment Project

  • Park, Jin-Hee
    • Journal of Navigation and Port Research
    • /
    • v.28 no.7
    • /
    • pp.601-608
    • /
    • 2004
  • Recently, port development has been actively in progress through a private investment project. Incheon North Port functions as an auxiliary port for Incheon Port to solve its chronic demurral and freight congestion and to treat materials such as wood, iron material, feed materials. Service charges is one of important factors in the port choice to treat general goods. In general, service charges can be calculated by two methods such as cost accounting method and market price method. This study will review the characteristics of the Incheon North Port (berth 3), which is under the progress of the private investment project and estimate the reasonable service charges for general goods on the basis of market price. This will help a concessionaire to maximize the operation efficiency.

A Study on Sway Control of Containers of Yard Crane (야드 크레인의 컨테이너 흔들림 제어에 관한 연구)

  • 박찬훈;박경택;김두형;신영재
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.04a
    • /
    • pp.64-71
    • /
    • 2000
  • Yard cranes are very useful equipments for handling of heavy containers. But rope-driven yard cranes must have a little of sway and skew motion because ropes are passive mechanical device. So many researches have been concentrated on anti-sway algorithm controlling trolley speed. These approaches require sway angle. But it is very difficult to know sway angle and its derivative. Therefore control algorithm of trolley speed is not practical in general. On the contrary, control strategy using auxiliary rope is very useful to sway control of yard crane because rope length is shorter than quay-side container cranes. In this paper, we derive equations of motion of trolley system which have anti-sway controller to use auxiliary rope. And we propose the control strategy and analyse the behavior of the proposed system.

  • PDF

A Study on Sway Control of Containers of Yard Crane (야드 크레인의 컨테이너 흔들림 제어에 관한 연구)

  • 박찬훈;박경택;김두형;신영재
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.143-151
    • /
    • 2000
  • Yard cranes are very useful equipments for handling of heavy containers. But rope-driven yard cranes must have a little of sway and skew motion because ropes are passive mechanical device. So many researches have been concentrated on anti-sway algorithm controlling trolley speed. These approaches require sway angle. But it is very difficult to know sway angle and its derivative. Therefore control algorithm of trolley speed is not practical in general. On the contrary, control strategy using auxiliary rope is very useful to sway control of yard crane because rope length is shorter than quay-side container cranes. In this paper, we derive equations of motion of trolley system which have anti-sway controller to use auxiliary rope. And we propose the control strategy and analyse the behavior of the proposed system.

  • PDF

Partial optional randomized response technique with calibration weighting to adjust non-response in successive sampling

  • Priyanka, Kumari;Trisandhya, Pidugu;Kumar, Ajay
    • Communications for Statistical Applications and Methods
    • /
    • v.28 no.5
    • /
    • pp.493-510
    • /
    • 2021
  • The present article endeavours to develop partial optional randomized - response technique (PORT) to deal with sensitive issues in presence of non-response in successive sampling. Calibration techniques have been embedded with PORT to estimate sensitive population mean at current move in two move successive sampling in presence of non-response. Optimum calibration weights are computed at each move with the aid of constraints based on auxiliary information. Detailed properties of the proposed estimators have been discussed. Possible cases in which non-response may creep at two moves has been explored. The proposed technique has been compared with the modified existing technique. Simulation results indicate that the proposed technique is more efficient than existing, modified one. Suitable recommendations are forwarded.

A Link Layer Design for DisplayPort Interface

  • Jin, Hyun-Bae;Yoon, Kwang-Hee;Kim, Tae-Ho;Jang, Ji-Hoon;Song, Byung-Cheol;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.14 no.4
    • /
    • pp.297-304
    • /
    • 2010
  • This paper presents a link layer design of DisplayPort interface with a state machine based on packet processing. The DisplayPort link layer provides isochronous video/audio transport service, link service, and device service. The merged video, audio main link, and AUX channel controller are implemented with 7,648 LUTs(Loop Up Tables), 6020 register, and 821,760 of block memory bits synthesized using a FPGA board and it operates at 203.32MHz.

A Novel Three-Port Converter for the On-Board Charger of Electric Vehicles (새로운 전기 자동차 온보드 충전기용 3-포트 컨버터)

  • Amin, Saghir;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.111-112
    • /
    • 2017
  • This paper presents a novel three-port converter for the OnBoard Charger of Electric Vehicles by using an impedance control network. The proposed concept is suitable for charging a main battery and an auxiliary battery of an electric vehicle at the same time due to its power handling capability of the converter without additional switches. The power flow is managed by the phase angle (${\Theta}$) between the ports whereas voltage at each port is controlled by the asymmetric duty cycle and the phase shift (${\Phi}$) between the inverter lags controlled by the impedance control network. The proposed system has a capability of achieving zero voltage switching (ZVS) and zero current switching (ZCS) at all the switches over the wide range of input voltage, output voltage and output power. The feasibility of the proposed system is verified by the PSIM simulation.

  • PDF