• Title/Summary/Keyword: Auxiliary current control

Search Result 181, Processing Time 0.03 seconds

Improved ZVT AC/DC PFC Boost Converter (개선된 ZVT AC/DC PFC Boost 컨버터)

  • Ryu, Jong-Gyu;Kim, Yong;Bae, Jin-Yong;Gye, Sang-Bum;Kwon, Soon-Do
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.172-175
    • /
    • 2005
  • Recently international regulations governing the amount of harmonic currents(e.g IEC 61000-3-2) became mandatory and active Power factor correction (PFC) pre-regulator circuit became inevitable for the AC/DC converters. Among these topologies, the boost topology represents an optimum solution for a PFC pre-regulation in a high power application. This paper propose improved ZVT(Zero Voltage Transition) AC/DC PFC Boost using the average current control employing a soft-switching technique of the auxiliary switch with a minimum number of components. The conventional ZVT PFC Boost Converter has a disadvantage that the auxiliary switch turns off hard, which influences the overall efficiency and the EMI problem. In this paper, an improved ZVT PFC Boost converter using active snubber is proposed to minimize the switching loss of the auxiliary. The prototype of 100kHz, 640W system was implemented to show the improved performance.

  • PDF

Implementation of a ZVT-PRT Current Controlled Inverters using a Digital Signal Processor (DSP를 이용한 ZVT-PRT 전류제어형 인버터의 구현)

  • 이성룡;전칠환;김상수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.425-429
    • /
    • 2002
  • In this paper, a single-phase inverter using a diode bridge-type resonant circuit to implement ZVT(Zero Voltage Transition) switching is presented. The current control algorithm is analyzed about how to design the circuit with auxiliary switch which can ZVT operation for the main power switch. The simulation and experimental results would be shown to verify the proposed current algorithm, because the main power switch is turn on with ZVT and the hi-directional inverter is operated.

  • PDF

An Inherent Zero-Voltage and Zero-Current-Switching Full-Bridge Converter with No Additional Auxiliary Circuits

  • Wang, Jianhua;Ji, Baojian;Wang, Hongbo;Chen, Naifu;You, Jun
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.610-620
    • /
    • 2015
  • An inherent zero-voltage and zero-current-switching phase-shifted full-bridge converter with reverse-blocking insulated-gate bipolar transistor (IGBT) or non-punch-through IGBT is proposed in this paper. This converter not only ensures that the switches in the lagging leg works at zero-current switching, but also minimizes circulating conduction loss without any additional auxiliary circuits. A 1.2 kW hardware prototype is designed, fabricated, and tested to verify the proposed topology. The control loop design procedures with small-signal models are also presented. A simple, low-cost, and robust democratic current-sharing circuit is also introduced and verified in this study. The proposed converter is a suitable alternative for compact, cost-effective applications with high-voltage input.

The Method to Improve the Luminance Efficiency by Auxiliary Capacitor in AC PDP

  • Lee, Ji-Hoon;Lee, Don-Kyu;Choi, Joon-Young;Ok, Jung-Woo;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo;Lee, Hae-June
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.913-916
    • /
    • 2006
  • The improvement of luminous efficacy is one of the major issues in PDP industry. In this work, we propose the new driving method for high efficiency AC-PDP and analyze its discharge characteristics. The suggested method can control the effective capacitance of panel by external auxiliary capacitor. External capacitor induces reduction of gap voltage proportional to the panel current, this in turn modifies the transient behaviour of discharge. The peak current level is reduced and the discharge duration is increased. As a result of these modifications, the luminous efficacy is enhanced by about 200% compared with the conventional driving method

  • PDF

A Study on the Zero-Voltage and Zero-Current-Switching Three Level DC/DC Converter using Secondary Coupled Inductor (2차측 결합 인덕터를 이용한 ZVZCS Three Level DC/DC 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Kim, Pill-Soo;Lee, Eun-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.200-204
    • /
    • 2001
  • A ZVZCS(Zero Voltage and Zero Current Switching) Three Level DC/DC Converter is presented to secondary auxiliary circuit. The new converter presented in this paper used a phase shift control with a flying capacitor in the primary side to achieve ZVS for the outer switch. A secondary auxiliary circuit, which consists of one small capacitor two small diode and one coupled inductor is added in the secondary to provides ZVZCS conditions to primary switches, ZVS for outer switches and ZCS for inner switches. Many advantages including simple circuit topology high efficiency, and low cost make the new converter attractive for high power applications. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 1kW 50kHz IGBT based experimental circuit.

  • PDF

Profile Control Using RF Wave Heating in KT-2 Tokamak

  • Ju, M.H.;Hong, B.G.;Kim, S.K.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.443-448
    • /
    • 1996
  • In this paper, the 100 % non-inductive current drive scenarios are addressed for the steady-state operation on KT-2 tokamak, with the profile control using fast wave and lower hybrid wave as the external tools. Considering the stability, the well-aligned current profiles with a reversed-shear and $q_{min}$ > 2.0 has been favor-able in high ${\beta}_{p}$ plasma, together with a possibly higher bootstrap current fraction. Therefore, the effects of the auxiliary heating power profile on the control of MHD favorable current profile are evaluated in detail.

  • PDF

ZVT boost converter with minimizing conduction losses of the main switch (주 스위치의 전도손실을 최소화한 ZVT 부스터 컨버터)

  • Chin Gi-Ho;Kang Ahn-Jong;Kim Tae-Woo;Kim Hack-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.95-98
    • /
    • 2003
  • A ZVT PWM Boost Converter is proposed to reduce current stresses and conduction losses of main switch in a conventional circuit. By attaching resonant inductor Lr1 in parallel with capacitor Cr, the resonant circulating current is diverted to the additional component and then the main switch is subjected to minimum current stresses same as those in their PWM counterparts. Moreover, the operation of the auxiliary switch in a half wave mode to prevent reverse resonant energy from freewheeling can be able to lessen the conduction losses. The operation principles of the proposed converters are analyzed using the PWM boost converter topology as an example. Theoretically analysis and experimental results verify the validity of the boost converter topology with the proposed circuit.

  • PDF

Development of 8kW ZVZCS Full Bridge DC-DC Converter by Parallel Operation (병렬제어를 적용한 8kW급 영전압/영전류 풀 브릿지 DC-DC 컨버터 개발)

  • Rho, Min-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.400-408
    • /
    • 2007
  • In this paper, development of the 8kW parallel module converter is presented. For a effective configuration of FB-PWM converter, this paper proposes 4-parallel operation of 2 kw-module. FB converter of 2-kW module is controlled by phase shut PWM and in order to achieve ZVZCS, the simple auxiliary circuit is applied in secondary side. In order to achieve ZCS, control logic for auxiliary circuit operation is designed to reset the primary current during free-wheeling period. For output current sharing of 4-modules, the charge control is employed. The charge control logic is designed with phase shift PWM logic. Voltage controller is implemented by using DSP(TMS320LF2406) with A/D conversion data of the output current and voltage of each module. The developed converter is installed in PCU(Power Conditioning Unit) for HSG(High Speed Generator) in a vehicle and health monitoring system is implemented for vehicle operation test. Finally, performance of the developed converter is proved under practical operation of HSG.

A Study on the Auxiliary Power Supply for the Railway Vehicle by Using Wide Band Gap Device (Wide Band Gap 소자를 적용한 철도차량용 보조전원장치에 관한 연구)

  • Choi, Yeon-Woo;Lee, Byoung-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.168-173
    • /
    • 2018
  • In this paper, an auxiliary power supply (APS) for railroad cars is proposed. The APS can reduce the number of devices required to supply power through structural modification and operates at a high switching frequency by application of a SiC device. The voltage stress on the device in the proposed circuit can be reduced to less than half of the input voltage of the system; thus, a device with low breakdown voltage can be designed. By adapting a SiC device instead of an IGBT device, the proposed circuit can reduce switching and conduction losses and operate at a high switching frequency, thereby reducing output voltage and inductor current ripples in the proposed circuit. The theoretical analysis results of the proposed APS are verified with a 40 kW computer-based simulation and a 2 kW experiment.

Design Criteria of the Auxiliary Resonant Snubber Inverter Using a Load-Side Circuit for Electric Propulsion Drives

  • Song, Byeong-Mun;Jih-Sheng(Jason) Lai;Kwon, Soon-Kurl
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.143-148
    • /
    • 1998
  • The Design criteria of the auxiliary resonant snubber inverter (ARSI) using a load-side circuit are discussed in relation to electric propulsion drives. In this regard, this paper attempts to develop a set of design criteria for the ARSI. First, the switching characteristics of IGBTs under soft-switching mainly in terms of dv/dt/, di/dt and switching losses are discussed and utilized for optimizing the selection of the resonant components in the system. After that, the proper control strategies of ARSIs are analyzed and simulated based on voltage space vector modulations. Later, the design, control and implementation of the auxiliary resonant circuit suitable for industrial products are analyzed and presented. And finally, other factors including power stage layout, packaging and the choice of current sensors are included. The detailed simulation and experimental results will be included based on a laboratory prototype. The proposed design criteria of the ARSI would help the implementation of an electric propulsion drive system.

  • PDF