A Study on Autonomous Driving Mobile Robot by using Intelligent Algorithm

  • Seo, Hyun-Jae;Kim, Hyo-Jae;Lim, Young-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.543-547
    • /
    • 2005
  • In this paper, we designed a intelligent autonomous driving robot by using Fuzzy algorithm. The object of designed robot is recognition of obstacle, avoidance of obstacle and safe arrival. We append a suspension system to auxiliary wheel for improvement in stability and movement. The designed robot can arrive at destination where is wanted to go by the old and the weak and the handicapped at indoor hospital and building.

  • PDF

Identification of Linear Structural Systems (선형 구조계의 동특성 추정법)

  • 윤정방
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1989.10a
    • /
    • pp.46-50
    • /
    • 1989
  • Methods for the estimation of the coefficient matrices in the equation of motion for a linear multi-degree-of-freedom structure arc studied. For this purpose, the equation of motion is transformed into an auto-regressive and moving average with auxiliary input (ARMAX) model. The ARMAX parameters are evaluated using several methods of parameter estimation; such as toe least squares, the instrumental variable, the maximum likelihood and the limited Information maximum likelihood methods. Then the parameters of the equation of motion are recovered therefrom. Numerical example is given for a 3-story building model subjected to an earthquake exitation.

  • PDF

IDENTIFICATION OF MODAL PARAMETERS BY SEQUENTIAL PREDICTION ERROR METHOD (순차적 예측오차 방법에 의한 구조물의 모우드 계수 추정)

  • Lee, Chang-Guen;Yun, Chung-Bang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1990.10a
    • /
    • pp.79-84
    • /
    • 1990
  • The modal parameter estimations of linear multi-degree-of-freedom structural dynamic systems are carried out in time domain. For this purpose, the equation of motion is transformed into the autoregressive and moving average model with auxiliary stochastic input (ARMAX) model. The parameters of the ARMAX model are estimated by using the sequential prediction error method. Then, the modal parameters of the system are obtained thereafter. Experimental results are given for a 3-story building model subject to ground exitations.

  • PDF

Performance Analysis of Combined Passive Solar System for Building South Wall (남측외벽에 적용한 혼합형 태양열시스템의 성능 분석)

  • Yun, Tae-Gyun;Lee, Hyun-Soo;Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.42-49
    • /
    • 2012
  • In this article, the author carried out a theoretical study on the application techniques of a new Combined Passive Solar System (hereinafter referred to as the CPSS) of direct gain and trombe walls to get quick morning heating and to prevent afternoon overheating for office building. The numerical model proposed in this study can be used for the performance analysis of the CPSS in the winter and summer. Heating and Cooling loads are analysed for building energy consumption reduction using this numerical model. The results indicate that CPSS in the winter and summer modes could provide profitable conditions for improvement of indoor thermal comfort control and energy saving. consequently, the application of CPSS will not lead to significant reductions in the auxiliary air conditioning demand but also realize the environmentally friendly building.

A Study on the Architectural Design of Student Circulation Space (학교건축의 복도(複道) 계획에 관한 연구)

  • Lee, Hwa-Ryong
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.3 no.1
    • /
    • pp.24-34
    • /
    • 2003
  • The architectural design of student circulation space has a pronounced influence on the educational function of a school building. Recent curriculum and new teaching methods have required the sufficient space provided for circulation and various circulation spaces in a school building, such as elevator, pilotis, bridge, atrium, deck, lobby and locker room. However excessive circulation space is wasteful form the standpoint of both initial investment and operation. This study aims to investigate new circulation patterns and functions, and to propose the adequate size in planning a school corridor. For this purpose, it explores the recent trends of the corridor planning represented in the excellent school facilities in 2002. and analyzes the newly-added functions In the school corridor : architectural in-between space, dwelling space for ordinary activities, space for educational media and auxiliary learning space. This research recommends that the corridor width be carefully planned according to the supposed functions in order to achieve the efficiency in the design of school facilities.

  • PDF

Investigation on damage development of AP1000 nuclear power plant in strong ground motions with numerical simulation

  • Chen, Wanruo;Zhang, Yongshan;Wang, Dayang;Wu, Chengqing
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1669-1680
    • /
    • 2019
  • Seismic safety is considered to be one of the key design objectives of AP1000 nuclear power plant (NPP) in strong earthquakes. Dynamic behavior, damage development and aggravation effect are studied in this study for the three main components of AP1000 NPP, namely reinforced concrete shield building (RCSB), steel vessel containment (SVC) and reinforced concrete auxiliary building (RCAB). Characteristics including nonlinear concrete tension and compressive constitutions with plastic damage are employed to establish the numerical model, which is further validated by existing studies. The author investigates three earthquakes and eight input levels with the maximum magnitude of 2.4 g and the results show that the concrete material of both RCSB and RCAB have suffered serious damage in intense earthquakes. Considering RCAB in the whole NPP, significant damage aggravation effect can be detected, which is mainly concentrated at the upper intersection between RCSB and RCAB. SVC and reinforcing bar demonstrate excellent seismic performance with no obvious damage.

Evaluation on Field Applicability of Cast-In-Place Pile using Surfactant Grout (계면활성제계 그라우트를 활용한 흙막이 벽체공법(CIP)의 현장 적용성 평가)

  • Do, Jinung;Kim, Hakseung;Park, Bonggeun;Lee, Juhyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.75-83
    • /
    • 2016
  • In case of underground construction affected by groundwater, CIP (Cast-In-Place Pile) method is generally used to resolve the geo-hydraulic problem. However, as this method has poor connectivity between piles, an auxiliary method for cut-off is needed in many cases. In this study, a new concept earth retaining wall method (H-CIP) with no auxiliary method, by using surfactant grout (Hi-FA) which improves antiwashout and infiltration ability, is introduced, and its field applicability is evaluated. CIP and H-CIP piles were installed with same ground conditions, and field and laboratory tests were conducted to verify the performance. As results, newly contrived H-CIP method shows higher field performance for cut-off and strength than conventional CIP method.

FLOODING PSA BY CONSIDERING THE OPERATING EXPERIENCE DATA OF KOREAN PWRs

  • Choi, Sun-Yeong;Yang, Joon-Eon
    • Nuclear Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.215-220
    • /
    • 2007
  • The existing flooding Probabilistic Safety Analysis(PSA) was updated to reflect the Korean plant specific operating experience data into the flooding frequency to improve the PSA quality. Both the Nuclear Power Experience(NPE) database and the Korea Nuclear Pipe Failure Database(NuPIPE) databases were used in this study, and from these databases, only the Pressurized Water Reactor(PWR) data were used for the flooding frequencies of the flooding areas in the primary auxiliary building. With these databases and a Bayesian method, the flooding frequencies for the flooding areas were estimated. Subsequently, the Core Damage Frequency(CDF) for the flooding PSA of the Ulchin(UCN) unit 3 and 4 plants based on the Korean Standard Nuclear Power Plant(KSNP) internal full-power PSA model was recalculated. The evaluation results showed that sixteen flooding events are potentially significant according to the screening criterion, while there were two flooding events exceeding the screening criterion of the existing UCN 3 and 4 flooding PSA. The result was compared with two kinds of cases: (1) the flooding frequency and CDF from the method of the existing flooding PSA with the PWR and Boiled Water Reactor(BWR) data of the NPE database and the Maximum Likelihood Estimate(MLE) method and (2) the flooding frequency and CDF with the NPE database(PWR and BWR data), NuPIPE database, and a Bayesian method. From the comparison, a difference in CDF results was revealed more clearly between the CDF from this study and case (2) than between case (1) and case (2). That is, the number of flooding events exceeding the screen criterion further increased when only the PWR data were used for the primary auxiliary building than when the Korean specific data were used.

Reconsideration of the Construction Period of the Jeongnimsaji Temple Site (정림사지 창건시기 재고)

  • Tahk, Kyung-Baek
    • Journal of architectural history
    • /
    • v.25 no.4
    • /
    • pp.57-64
    • /
    • 2016
  • It was believed that Jeongnimsa temple was built after the capital was moved from Gongju to Buyeo. It was confirmed that it was built A.D. $625{\pm}20$ by conducting a paleomagnetic analysis on the fireplace, which was recently found at the bottom of Jungmunji(middle gate). Consequently, it is assumed that the temple was built in the early 7th century unlike the previous point of view. Therefore, this study evaluated if the fireplace at the bottom of Jungmunji was found at the geological stratum representing the Jeongnimsa temple. Moreover, the study examined when the fireplace at the bottom of Jungmunji was constructed on the soil stratum. It is possible that the fireplace was built in the early 7th century as shown in the paleomagnetic analysis. However, when we compared the soil strata of the Jungmunji and the existing five-story stone pagoda, it showed that the ground was prepared differently and they were built over a fairly long period of time. Furthermore, I discovered that there was a wooden pagoda under the five-story stone pagoda by examining the soil strata map. Therefore, previous studies evaluated the arrangement of auxiliary buildings of Jeongnimsa temple and concluded that it was built in the early 7th century. It is hard to determine when the temple was built based on the arrangement of auxiliary buildings, because it takes a long time to build a temple and auxiliary buildings can be relocated during this long construction period. Rather, we have to admit that there are various arrangement patterns through minor changes in buildings from the one pagoda and one main building(Geumdang) arrangement.

Development of Inspection Technique for Filling or Unfilling of Containment Liner Plate Backside Concrete in Nuclear Power Plant (원전 격납건물 라이너플레이트 배면 콘크리트 채움 여부 점검 기술 개발)

  • Lee, Jeong Seok;Kim, Wang Bae;Kwak, Dong Ryul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.37-41
    • /
    • 2020
  • The Nuclear containment building is a main safety-related structure that performs shielding and conservation functions to prevent highly radioactive materials from leakage to the outside environment in the case of various environmental conditions and postulated accidents. The containment building contains a reactor, steam generator, pressurizer, tank, reactor coolant system, auxiliary system and engineering safety system, and is designed so that highly radioactive materials above the limits specified in 10 CFR 100 do not escape to the outside environment in the case of LOCA(Loss of Coolant Accident) for instance. The containment metal liner plate(CLP) is a carbon steel plate with a nominal plate thickness of 6 mm, which functions as a mold for the wall and dome of the containment building when concrete is filled, fulfills airtightness to prevent leakage of seriously radioactive materials. In recent years, backside corrosion was found on the liner plate in some domestic nuclear power plants. The main cause of backside corrosion was unfilled concrete. In this paper, an inspection technique of assessing filling suitability for CLP backside concrete is developed. Results show that the validity of inspection technique for CLP backside concrete using vibration sensor is successfully verified.