• Title/Summary/Keyword: Automatic measurement system

Search Result 607, Processing Time 0.029 seconds

Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter (리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.42-47
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors in the automatic remote measurement of water meter a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact switch by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used mostly in measurement application to detect the rotational or translational displacement. To apply for water flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just mounted simply on the conventional mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor two steel leaf springs make mechanical contact and apart repeatedly as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But the digital data is occurred difference or won by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing vehicle near to the switch sensor installed location causes chattering. In order to reduce chattering error, most system uses just software methods, for example using filter algorithm and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical characteristics.

Test of Communication Distance Measurement of Fishing Gear Automatic System Based on Private LoRa (Private LoRa 기반 어구 자동식별 시스템의 거리 측정 시험)

  • Lee, Seong-Real;Kim, Se-Hoon
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • Since the ocean accounts for 70.8 percent of the earth's surface, the success of IoT technology in the marine industry is to collect information from devices placed in a wider range. LPWA is a feature with a wide range of communication and is very suitable for deployment in the ocean. In this paper, the real-sea performance distance experiment was carried out based on Private LoRa, a key technology for executing the electronic phrase real-name system. A private LoRa module based on sx1276 was developed, and Gateway was developed to transfer data received by private LoRa to the server using SKT Cat. M1. After installing gateways at 599 meters above sea level and experimenting with data transmission and reception at 25 km, 40 km and 60 km, we were able to see that the communication success rate was obtained to be 96.1%. 97.1% and 96.2% respectively.

Fabrication and Verification of a Water Quality Sensor Equipped with Active RFID Function for Real Time Location (위치추적용 능동형 RFID 기능을 장착한 수질 측정 센서의 제작 및 검증)

  • Jung, Young-Sub;Chang, Hun;Kim, Jin-Young;Kang, Joon-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.113-120
    • /
    • 2009
  • Through the automatic sensing of the environment, USN technology can give the best services. In this work, we have developed an active RFID system and examined its performance. By implementing it into water quality sensors, we constructed a system that can detect diverse indoor/outdoor environment and provide information about the pollution level obtained from the temperature and PH sensors. Our RF system had an internal Print-on-PCB antenna for the miniaturization of the tag. We used a RF transceiver CC2510 chipset of TI company to realize the active RFID function. By using RSSI constants obtained, we performed the evaluation of real time location accuracy with a software written in Labview. Among 10 arbitrary locations, we obtained average measurement errors of 1.69 m in x axis and 1.66 m in y axis. This technology can be applied to logistics, environmental monitoring, prevention of missing children and various applications.

  • PDF

A Design an Implementation of a Base Station Transceiver for WLL System (무선 가입자 접속망 기지국용 송수신기 설계 및 구현)

  • 정영준;강상기;이일규;김봉겸;홍헌진
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.6
    • /
    • pp.600-613
    • /
    • 1997
  • The implementation of a BTS(Base station Transceiver) for WLL system using W-CDMA(Wideband-Code Division Multiple Access) method is presented in this paper. It consists of three boards; receiver, transmitter and RF controller. Some RF parameters are considered and simulated by the RF simulation S/W using commercial and customized components specifications. The implemented transceiver of 5 MHz RF channel bandwidth satisfies the system requirements of a transceiver such as dynamic range, sensitivity in the receiver and spurious emission suppression in the transmitter. At the receiver, the experimental measurement showed 2.86 dB of NF and 60 dB above of dynamic range in AGC(Automatic Gain Control) locking. At the transmitter, the -49.46 dBc of spurious emission suppression is attained when the output power of the transmitter is 34.3 dBm. These results are good enough to meet to standard performance specifications.

  • PDF

Development of Automatic Inspection System for ALC Block Using Distortion Correction Technique (왜곡 보정 기법을 이용한 ALC 블럭의 자동 검사 시스템 개발)

  • Han, Kwang-Hee;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • The lens distortion in the machine vision system is inevitable phenomenon. Distortion is getting worse, due to the selection of lens in the trend of reducing prices and size of the system. In this trend, the distortion correction becomes more important. But, the traditional correction methods has problems, such as complexity and requiring more operations. Effective distorted digital image correction is the precondition of target detection and recognition based on vision inspection. To overcome the disadvantage of traditional distortion correction algorithms, such as complex modeling, massive computation and marginal information loss, an image distortion correction algorithm based on photogrammetry method is proposed in this paper. In our method, we use the lattice image as the measurement target. Through the experimental results, we could find that we can reduce the processing time by 4ms. And also the inspection failure rate of our method was reduced by 2.3% than human-eyes inspection method.

A Study on the Development of Low Power Automatic ON/OFF Valve System for Gas Leak Detection (가스 누출 감지를 위한 저전력 자동 ON/OFF 밸브 시스템 개발에 관한 연구)

  • Choi, Young Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.369-374
    • /
    • 2021
  • Apartment recently built in kitchen is made is made because the gas hose with built-in ways invisible inside the sink. In this case, if the gas leaks, it is a dangerous method that can accumulate inside the sink and lead to an explosion. In this study, since the hose connected between the gas range and the intermediate valve is inside the sink, it is not possible to test for gas leaks, so a valve system that can easily check for gas leaks using a pressure sensor was studied. As for the pressure measurement method, the pressure of the hose connecting the intermediate valve and the gas range was measured so that data could be collected and analyzed using the I2C communication method. In addition, the calculation of the gas pressure supplied to the home was investigated for the atmospheric pressure error for the value calculated by adding the average value of the gas gauge pressure of 22.46 mbar at the inlet of the gas meter to the atmospheric pressure. A valve system was developed to detect minute gas leaks.

Slope Behavior Analysis Using the Measurement of GFRP Underground Displacement (GFRP 록볼트 계측을 통한 사면 거동 분석)

  • Jin, Ji-Huan;Lim, Hyun-Taek;Bibek, Tamang;Chang, Suk-Hyun;Kim, Yong-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.11-19
    • /
    • 2018
  • Although many researches related to monitoring and automatic measuring devices for early warning system during slope failure have been carried out in Korea and aboard, most of the researches have installed measuring devices on the slope surface, and there are only few researches about warning systems that can detect and warn before slope failure and disaster occurs. In this study, slope failure simulation experiment was performed by attaching sensors to rock bolts, and initial slope behavior characteristics during slope failure were analyzed. Also, the experiment results were compared and reviewed with varied slope conditions, i.e. shotcrete slope and natural slope, and varied material conditions, i.e. GFRP and steel rock bolt. This study can be used as a basic data in development of warning and alarm system for early evacuation through early detection and warning before slope failure occurs in steep slopes and slope failure vulnerable areas.

Development of LabVIEW-based Data Storage and Monitoring Program for a Condensed Hydrogen Liquefaction System (응축형 수소 액화 시스템에 대한 LabVIEW 기반 데이터 저장 및 모니터링 프로그램 개발)

  • DONG WOO HA;HYUN WOO NOH;YOUNG MIN SEO;TAE HYUNG KOO;ROCK KIL KO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.456-464
    • /
    • 2023
  • In this study, a compact hydrogen liquefaction system was constructed with the aim of creating a data storage and monitoring program for liquid hydrogen production. This program was designed to receive and record signals from diverse control equipment through the LabVIEW software. A range of measurement instruments were devised to collect data, encompassing variables such as flow rate, pressure, temperature, and liquid level. As a result, it was possible to directly check the production of liquid hydrogen by obtaining various data of condensed liquid hydrogen. In addition, it was confirmed that long-term storage of liquid hydrogen is possible by developing automatic ON/OFF through the LabVIEW program.

Design of Head Blood Pressure(HBP) Measurement System and Correlativity Extraction of Blood Pressure(BP) and HBP (두부혈압 측정 시스템의 설계 및 두부혈압과 상완혈압과의 상관성 추출)

  • 이용흠;정석준;장근중;정동영
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.381-389
    • /
    • 2003
  • Various adult diseases (cerebral apoplexy, athymiait, etc.) result from hypertension, blood circulation disturbance and increment of HBP. In early diagnosis of these diseases, MRI, X-ray and PET have been used rather aim for treatment than for a prevention of disease. Since. cerebral apoplexy and athymiait could appear to the regular/irregular persons, it is very important to measure HBP which has connection with cerebral blood flow state. HBP has more diagnosis elements than that of BP. So, we can diagnose accurate hypertension by measuring of HBP. But, existing sphygmomanometers and automatic BP monitors can not measure HBP, and can not execute complex function(measuring of BP/HBP, blood flow improvement). Purpose of this paper is to develop a system and algorithm which can measure BP/HBP for accurate diagnosis. Also, we extracted diagnosis factors by correlativity analysis of BP/HBP. Maximum pressure of HBP corresponds to 62% that of BP, Minimum pressure of HBP corresponds to 46% that of BP. Therefore, we developed the multi-function automatic blood pressure monitor which can measure BP/HBP and improve cerebral blood flow state.

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(III) -A variation of temperature and humidity by the window opening ways of the even-Span type house- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(III) -양지붕형 하우스의 창 개방방법에 따른 온.습도의 변화-)

  • 김진현;김철수;구건효;이기명
    • Journal of Biosystems Engineering
    • /
    • v.20 no.2
    • /
    • pp.162-172
    • /
    • 1995
  • The ventilation in greenhouse have been important for such as adjustment of temperature, supplying of the oxygen, prevention of the overhumidity, density adjustment of $CO_2$, discharge of harmfulness gas, etc. However, the general ventilation which had been used the quantitative control method in discharge of a property of air mechanism in greenhouse, and caused mainly in waste of the heating energy and growth obstacle of the vegetable. Therefore, this study was peformed to obtain more scientific ventilation method using by analysis and measurement of the isothermal lines according to opening of window ventilation in greenhouse, and the results are summarized as follows. 1. The ventilating amount was more influenced by rather opening amount of window than the ventilating time. 2. In window ventilation, the temperature in greenhouse was mostly changed within 5 minutes after ventilating not regard to the spot of opening, after about 10 minutes temperature became to equilibrium state under the respective ventilating conditions. 3. In opening of the skylight only, isothermal lines were complicated, therefore, a tall vegetable may be possible to damage by a cold-weather from the lower central port in greenhouse. 4. Isothermal lines were a tendency to simply in opening of a side window that may be more effective ventilation in kinds of the short vegetable. 5. In conditions of internal temperature>setting temperature>external temperature, a skylight can be suitable to open 10~20cm in order to the optimum ventilation in greenhouse. 6. In conditions of internal temperature>external temperature>setting temperature, opening of all the windows or both the side windows that can be suitable in order to obtain the optimum ventilation in greenhouse. 7. An effect of ventilation was the most excellent to open of all the windows or both the side windows, and it were also found orderly excellent to open of the side window and the skylight or the skylight only, to open of the side window only. 8. Temperature was varied as the equation of T=Tc+ (To-Tc)e-at, and the ranges of (a) values were limited within 0.34~0.68. 9. A variations of humidity were similar to that of temperature, s.

  • PDF