• Title/Summary/Keyword: Automatic level measurement

Search Result 98, Processing Time 0.024 seconds

Measurement and Analysis of Free Water Evaporation at HaeNam Paddy Field (해남 농경지에서의 자유 수면 증발 관측과 해석)

  • Han Jin-Su;Lee Bu-Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.91-97
    • /
    • 2005
  • Class A evaporation pan has been used throughout the world to measure free water evaporation mainly by manual observation once a day. In this study, a new automatic water level measurement method is used for understanding of free water evaporation and numerical analysis. This new technique measures the weight of buoyancy bar in water, and does not need calibration because it is not affected by water density change with water temperature. Field observations of evaporation were made near Haenam Meteorological Station over paddy field located in southwestern Korea from 20 April to 30 May 2004 and the data from ten clear days (16 - 25 May) were used for this analysis. The observed total evaporation was about 50.7mm during this period whereas the estimated from an empirical equation was 50.4mm. As expected, the pan evaporation is well correlated with wind speed and the vapor pressure deficit between the water surface and the air.

Comparison of Visual- and Automatic Coregistration with MR Template based ROI Methods for Measurement of Specific Striatal Binding Ratio (SBR) in I-123 IPT SPECT

  • 주라형;서태석;최보영;이형구;김재승;문대혁
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.107-107
    • /
    • 2002
  • 목적: I-123 IPT SPECT에서 striatum에 ROI를 설정하여 Strial Binding Ratio를 측정하기 위해 사용되는 육안적인 방법과 MR Template based Coregistration 방법을 비교 평가하였다. 대상 및 방법: 파킨슨씨병 환자(IPD) 15명(남/녀:8/7, 63.3$\pm$4.8세)과 정상인 8명(남/녀:2/6, 61.4$\pm$16.5세) 에서 I-123 IPT(259MBq)를 주사한 후 2시간에 SPECT 영상을 얻었고 미상핵과 조가비핵의 전, 후부 및 후두엽에 각각 육안적인 방법과 MR Template based Coregistration방법으로 ROI를 설정하였다. MR Template based Coregistration 방법은 MNI TIMR template을 이용하여 SPECT영상을 voxel based intensity matching 방법으로 coregistration한 후midthalamic level에서 striatum의 경계를 따라 설정된 ROI를 이용하였다. 육안적인 방법은 striatal uptake가 가장 높은 level에서 3개의 ROI template를 striatum에 위치하였다. 두 방법으로 SBR과 nnterior/posterior ratio of SBR(APR)를 측정하였고 정상인과 파킨슨씨병 환자에서 두 방법을 비교하였다.

  • PDF

High Speed and Sensitive X-ray Analysis System with Automated Aberration Correction Scanning Transmission Electron Microscope

  • Inada, Hiromi;Hirayama, Yoichi;Tamura, Keiji;Terauchi, Daisuke;Namekawa, Ryoji;Shichiji, Takeharu;Sato, Takahiro;Suzuki, Yuya;Ohtsu, Yoshihiro;Watanabe, Keitaro;Konno, Mitsuru;Tanaka, Hiroyuki;Saito, Koichiro;Shimoyama, Wataru;Nakamura, Kuniyasu;Kaji, Kazutoshi;Hashimoto, Takahito
    • Applied Microscopy
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • We have developed a new HD-2700 (Hitachi High-Technologies Corp., Japan) scanning transmission electron microscope (STEM) that includes an automatic aberration correction function, and a large-solid-angle energy-dispersive X-ray spectroscopy detector that enables high-resolution and sensitive analysis. For observation with atomic resolution, using spherical-aberration-corrected STEM, in order that satisfactory performance of the device can be achieved readily, and within a short time, irrespective of the operator's skill level, a spherical-aberration-correction device with an automatic aberration-correction function was developed. This automatic aberration-correction function carries out the entire correction-related process (aberration measurement, selection and correction) automatically, with automatic selection of the aberrations that require correction, and automatic measurement of the appropriate corrections.

A Study on the In-process Detection of Fracture of Endmill by Acoustic Emission Measurement (음향방출을 이용한 가공중의 엔드밀 파손 검출에 관한 연구)

  • Yoon, Jong-Hak;Kang, Myung-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.3
    • /
    • pp.75-82
    • /
    • 1990
  • Automatic monitoring of the cutting conditions is one of the most improtant technologies in machining. In this study, the feasibility in applying acoustic emission(AE) signals for the in-process detection of endmill wear and fracture has been investigated by performing experimental test on the NC vertical milling machine with SM45C for specimen. As the results of detecting and analyzing AE signals on various cutting conditions, the followings have confirmed. (1) The RMS value of acoustic emission is related sensitively to the cutting velocity, but is not affected largely by feed rate. (2) The burst type AE signals of high level have been observed when removing chips distorderly and discontinuously. (3) When the RMS value grows up rapidly due to the increase of wear the endmill are generally broken or fractured, but when the endmills fracture at the conditions of smooth chip-flow or built-up-edge(BUE) occurred frequently, the rapid change of the RMS arenot found. And it is expected that this technigue will be quite useful for in-process sensing of tool wear and fracture.

  • PDF

Research for a Development of the Test Equipment for Transmission Error of the Planetary Gear Carrier Pack (유성기캐리어팩 전달오차 측정 장비 개발에 관한 연구)

  • Lee, Hyun Ku;Do, Jong Gu;Yoo, Dong Kyu;Won, Kwang Min;Chung, Si Deuk;Lee, Tae Hwi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.348-349
    • /
    • 2014
  • In general, there has been a lot of research concerned about the gear noise known to be proportional to gear transmission error for external gears likewise spur, helical gear, and hypoid gears. But, In the case of planetary gear set, gear noise study is insufficient because of the difficulty of designing, manufacturing, and understanding of the its mechanical system. This study is aimed to develop the transmission error measurement equipment for the planetary gear sets used in the automatic transmission. By comparing the results of the transmission error and noise objectively, user could select the optimized planetary gear set which has quiet noise level before manufacturing the automatic transmission.

  • PDF

The Development of A Device to Measure the Ripeness and Internal Quality of Watermelons

  • Yshihide-Kouno;Toshihiro-Mizuno;Hiromu-Maeda;Akinaga, T-Akayoshi;Yoshihiro-Kohda
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1346-1353
    • /
    • 1993
  • Recently , it has been popular for family use to sell a watermelon by the piece such as a half or a quarter. Therefore, it has been necessary to detect and sort out hollow or overripened watermelons before they are shipped. Previously, inspection and rejection of hollow or overripened watermelons were carried out by skilled inspectors with their experience and intuition based on the traditional slapping method. In recent years many inspectors have became older and are going to retire. Thus automatic quality measuring devices have to be developed. There are many reports on the measurement of internal quality for watermelons with non-destructive methods. However, there is no online device to detect and measure both hollow and ripeness of watermelons until now. We have developed the model MWA-9002 online device to detect hollow and measuring the ripeness of watermelons by acoustic impulse. The developed of this devices has enables accurate distinction and rejection at the same level of the skilled inspectors, and also has saved labor. Nowadays nine automatic watermelon sorting and packing facilities applied this device have installed in Japan.

  • PDF

Research for a Development of the Test Equipment for Transmission Error of the Planetary Gear Carrier Pack (유성기어 캐리어팩 전달오차 측정 장비 개발에 관한 연구)

  • Lee, Hyun Ku;Do, Jong Gu;Hong, Sa Man;Yoo, Dong Kyu;Won, Kwang Min;Chae, Geum Muk;Lee, Tae Hwi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.549-554
    • /
    • 2014
  • In general, there has been a lot of research concerned about the gear noise known to be proportional to gear transmission error for external gears likewise spur, helical gear, and hypoid gears. But, In the case of planetary gear set, gear noise study is insufficient because of the difficulty of designing, manufacturing, and understanding of its mechanical system. This study is aimed to develop the transmission error measurement equipment for the planetary gear sets used in the automatic transmission. By comparing the results of the transmission error and noise objectively, user could select the optimized planetary gear set which has quiet noise level before manufacturing the automatic transmission.

Theft Prevention Technology for Smart Stroller using Distance Measurement of Dual Beacon (듀얼 비콘의 거리측정을 활용한 스마트 유모차용 도난방지 기법)

  • Chung, Myoungbeom
    • Journal of Internet Computing and Services
    • /
    • v.21 no.6
    • /
    • pp.71-79
    • /
    • 2020
  • In this paper, we propose a theft prevention technology based on beacon and smart device for smart stroller. The smart stroller has two Bluetooth devices. One is for data transmission and the other is for distance measurement as beacon. Thus, smart device uses a Bluetooth for strength level setting, manual locking and data transmission of smart stroller. Furthermore, smart device can do automatic locking of smart stroller using Bluetooth beacon when the stroller go further away from smart device. At this time, we apply a distance measurement algorithm and theft prevention algorithm with improved beacon distance measurement technique. To show usefulness of the proposed technology, we make a smart stroller and developed a smart device application. We did two distance measurement experiments and a theft prevention experiment with the proposed technology and the result shows 91.3% accuracy for theft prevention. Therefore, the proposed technology would be more usefulness technology for smart stroller.

Exploring the Reliability of an Assessment based on Automatic Item Generation Using the Multivariate Generalizability Theory (다변량일반화가능도 이론을 적용한 자동문항생성 기반 평가에서의 신뢰도 탐색)

  • Jinmin Chung;Sungyeun Kim
    • Journal of Science Education
    • /
    • v.47 no.2
    • /
    • pp.211-224
    • /
    • 2023
  • The purpose of this study is to suggest how to investigate the reliability of the assessment, which consists of items generated by automatic item generation using empirical example data. To achieve this, we analyzed the illustrative assessment data by applying the multivariate generalizability theory, which can reflect the design of responding to different items for each student and multiple error sources in the assessment score. The result of the G-study showed that, in most designs, the student effect corresponding to the true score of the classical test theory was relatively large after residual effects. In addition, in the design where the content domain was fixed, the ranking of students did not change depending on the item types or items. Similarly, in the design where the item format was fixed, the difficulty showed little variation depending on the content domains. The result of the D-study indicated that the original assessment data achieved a sufficient level of reliability. It was also found that higher reliability than the original assessment data could be obtained by reducing the number of items in the content domains of operation, geometry, and probability and statistics, or by assigning higher weights to the domains of letters and formulas, and function. The efficient measurement conditions presented in this study are limited to the illustrative assessment data. However, the method applied in this study can be utilized to determine the reliability and to find efficient measurement conditions for the various assessment situations using automatic item generation based on measurement traits.

Constant Current & Constant Voltage Battery Charger Using Buck Converter (벅 컨버터를 이용한 정전류 정전압 배터리 충전기)

  • Awasthi, Prakash;Kang, Seong-Gu;Kim, Jeong-Hun;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.399-400
    • /
    • 2012
  • The proposed battery charger presented in this paper is suitable for Lead-Acid Battery and the dc/dc buck converter topology is applied as a charger circuit. The technique adopted in this charger is constant current & constant voltage dual mode, which is decided by the value of voltage of proposed battery. Automatic mode change function is detected by the percentage value of level of battery charging. CC Mode (Constant Current Mode) is operated when charging level is below 80% of the total charging of Battery voltage and above 80% of battery voltage charging, CV Mode (Constant Voltage Mode) is automatically operated. As the charging level exceeds 120%, it automatically terminates charging. The feedback signal to the PWM generator for charging the battery is controlled by using the current and voltage measurement circuits simultaneously. This technique will degrade the damage of proposed type of battery and improve the power efficiency of charger. Finally, a prototype charger circuit designed for a 12-V 7-Ah lead acid battery is constructed and tested to confirm the theoretical predictions. Satisfactory performance is obtained from simulation and the experimental results.

  • PDF