• Title/Summary/Keyword: Automatic Use

Search Result 1,762, Processing Time 0.034 seconds

The utility of digital evaluation based on automatic item generation in mathematics: Focusing on the CAFA system (수학교과에서 자동문항생성 기반의 디지털 평가 활용 방안: CAFA 시스템을 중심으로)

  • Kim, Sungyeun
    • The Mathematical Education
    • /
    • v.61 no.4
    • /
    • pp.581-595
    • /
    • 2022
  • The purpose of this study is to specify the procedure for making item models based on ontology models using automatic item generation in the mathematics subject through the CAFA system, and to explore the generated item instances. As an illustration for this, an item model was designed as a part of formative assessment based on the content characteristics, including concepts and calculations, and process characteristics, including application, using the representative values and the measures of dispersion in Mathematics of the 9th grade based on the evaluation criteria achievement standards. The item types generated in one item model were a best answer type, a correct answer type, a combined-response type, an incomplete statement type, a negative type, a true-false type, and a matching type. It was found that HTML, Google Charts, TTS, figures, videos and so on can be used as media. The implications of the use of digital evaluation based on automatic item generation were suggested in the aspects of students, pre-service teachers, general teachers, and special education, and the limitations of this study and future research directions were presented.

Methodology of Automatic Editing for Academic Writing Using Bidirectional RNN and Academic Dictionary (양방향 RNN과 학술용어사전을 이용한 영문학술문서 교정 방법론)

  • Roh, Younghoon;Chang, Tai-Woo;Won, Jongwun
    • The Journal of Society for e-Business Studies
    • /
    • v.27 no.2
    • /
    • pp.175-192
    • /
    • 2022
  • Artificial intelligence-based natural language processing technology is playing an important role in helping users write English-language documents. For academic documents in particular, the English proofreading services should reflect the academic characteristics using formal style and technical terms. But the services usually does not because they are based on general English sentences. In addition, since existing studies are mainly for improving the grammatical completeness, there is a limit of fluency improvement. This study proposes an automatic academic English editing methodology to deliver the clear meaning of sentences based on the use of technical terms. The proposed methodology consists of two phases: misspell correction and fluency improvement. In the first phase, appropriate corrective words are provided according to the input typo and contexts. In the second phase, the fluency of the sentence is improved based on the automatic post-editing model of the bidirectional recurrent neural network that can learn from the pair of the original sentence and the edited sentence. Experiments were performed with actual English editing data, and the superiority of the proposed methodology was verified.

Comparison of pain relief in soft tissue tumor excision: anesthetic injection using an automatic digital injector versus conventional injection

  • Hye Gwang Mun;Bo Min Moon;Yu Jin Kim
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.1
    • /
    • pp.17-21
    • /
    • 2024
  • Background: The pain caused by local anesthetic injection can lead to patient anxiety prior to surgery, potentially necessitating sedation or general anesthesia during the excision procedure. In this study, we aim to compare the pain relief efficacy and safety of using a digital automatic anesthetic injector for local anesthesia. Methods: Thirty-three patients undergoing excision of a benign soft tissue tumor under local anesthesia were prospectively enrolled from September 2021 to February 2022. A single-blind, randomized controlled study was conducted. Patients were divided into two groups by randomization: the experimental group with digital automatic anesthetic injector method (I-JECT group) and the control group with conventional injection method. Before surgery, the Amsterdam preoperative anxiety information scale was used to measure the patients' anxiety. After local anesthetic was administered, the Numeric Pain Rating Scale was used to measure the pain. The amount of anesthetic used was divided by the surface area of the lesion was recorded. Results: Seventeen were assigned to the conventional group and 16 to the I-JECT group. The mean Numeric Pain Rating Scale was 1.75 in the I-JECT group and 3.82 in conventional group. The injection pain was lower in the I-JECT group (p< 0.01). The mean Amsterdam preoperative anxiety information scale was 11.00 in the I-JECT group and 9.65 in conventional group. Patient's anxiety did not correlate to injection pain regardless of the method of injection (p= 0.47). The amount of local anesthetic used per 1 cm2 of tumor surface area was 0.74 mL/cm2 in the I-JECT group and 2.31 mL/cm2 in the conventional group. The normalization amount of local anesthetic was less in the I-JECT group (p< 0.01). There was no difference in the incidence of complications. Conclusion: The use of a digital automatic anesthetic injector has shown to reduce pain and the amount of local anesthetics without complication.

A study on improving the performance of the machine-learning based automatic music transcription model by utilizing pitch number information (음고 개수 정보 활용을 통한 기계학습 기반 자동악보전사 모델의 성능 개선 연구)

  • Daeho Lee;Seokjin Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.207-213
    • /
    • 2024
  • In this paper, we study how to improve the performance of a machine learning-based automatic music transcription model by adding musical information to the input data. Where, the added musical information is information on the number of pitches that occur in each time frame, and which is obtained by counting the number of notes activated in the answer sheet. The obtained information on the number of pitches was used by concatenating it to the log mel-spectrogram, which is the input of the existing model. In this study, we use the automatic music transcription model included the four types of block predicting four types of musical information, we demonstrate that a simple method of adding pitch number information corresponding to the music information to be predicted by each block to the existing input was helpful in training the model. In order to evaluate the performance improvement proceed with an experiment using MIDI Aligned Piano Sounds (MAPS) data, as a result, when using all pitch number information, performance improvement was confirmed by 9.7 % in frame-based F1 score and 21.8 % in note-based F1 score including offset.

A Numerical Simulation for Thermal Environments by the Modification of Land-use in Busan (부산지역 토지이용(land-use) 변화에 의한 열환경 수치모의)

  • 김유근;문윤섭;오인보;임윤규
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.453-463
    • /
    • 2002
  • Prognostic meteorological model, MM5V3 (Mesoscale Model 5 Version 3) was used to assess the effects of the land-use modifications on spatial variations of temperature and wind fields in Busan during the selected period of summer season in 2000. We first examined sensitivity analysis for temperature between MM5V3 predictions and meteorological data observed at 4 AWS (Automatic Weather System) stations in Busan, which exhibited low structural and accurate errors (Mean Bias Error, MBE: 0.73, Root Mean Square Error, RMSE: 1.18 on maximum). The second part of this paper, MMSV3 simulations for the modification of land-use was performed with 1 km resolution in target domain, 46$\times$46 $\textrm{km}^2$ area around city of Busan. It was found that modification result from change of surface land-use in central urban area altered spatial distributions of temperature and wind. In particular, heat island core moved slightly to the seaward at 1300 LST. This results may imply that modification of surface land-use leads to change the thermal environments; in addition, it has a significant effect on local wind circulations and dispersions of air pollutants.

Automatic Dynamic Memory Management Techniques for Memory Scarce Java system (메모리가 적은 자바 시스템을 위한 자동 동적 메모리 관리 기법)

  • Choi, Hyung-Kyu;Moon, Soo-Mook
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.8
    • /
    • pp.378-384
    • /
    • 2008
  • Many embedded systems are supporting Java as their software platform via Java virtual machine. Java virtual machine manages memory automatically by providing automatic memory management, i.e. garbage collector. Because only scarce memory is available to embedded system, Java virtual machine should use small memory and manage it efficiently. This paper introduces two memory management techniques to exploit small memory in Java virtual machine which can execute multiple Java applications concurrently. First, compaction based garbage collection is introduced to overcome external fragmentation problem in presence of immovable memory area. Then garbage collector driven class unloading is introduced to reduce memory use of unnecessary loaded classes. We implemented these techniques in working embedded system and observed that they are very efficient, since more Java applications are able to be executed concurrently and memory use is also reduced with these techniques.

A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System (전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구)

  • Kang, Chang-Soo;Kang, Ki-Seong
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.25-30
    • /
    • 2009
  • The cooling water circulation pipes had been used to drop the temperature of refractory outside shell of blast furnace by cooling plate or stave type. They were attacked by surrounding CO gas and it was the cause that they were corroded and the water inflow in the refractory due to leakage of water. So, the life of refractory material was shorten and changed for the worse the conditions of blast furnace. The automatic sensing device for water leakage of cooling pipe was developed to check the position of trouble by use the micro-process system when cooling water leak and then CO gas will be inflowed into the cooling pipe at the leakage position. The inflowed CO gas will be detected in the micro-process system and delivered the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave the water leakage part immediately and then deliver the signal to main control room by use the micro-process system and wireless-radio relay station. This system will develop the working condition from manual system to unmanned auto alarm system.

A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.4 no.2
    • /
    • pp.3-13
    • /
    • 1990
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the ]after fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern Higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First. We are going to look history of the fire protection system and change course of that with the year and facility. Second, We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

An Automatic AP Connections Scheme using iBeacon (iBeacon을 이용한 AP 자동접속 방안)

  • Nam, ChoonSung;Shin, DongRyeol
    • Journal of Internet Computing and Services
    • /
    • v.18 no.2
    • /
    • pp.1-11
    • /
    • 2017
  • There are two kinds of wireless network access to a certain place by using smart devices - 1) open (anonymous) - access and 2) user-authorized access. The open-access is a non-authorization connection method which does not need to require Smart device's user authorized information. It means open-access use only user's SSID (Service Set Identifier) information to access the wireless AP devices following public wireless network standard. This access mechanism is not suitable to use all of public wireless networks because users have to get all wireless network information around them. As a result, huge data for smart devices should be one of the most critical overload problems for them. Secondly, the user-authorized access method uses wireless network information (SSID and password) chosen by the users. So, the users have to remember and use the network access information data manually whenever accessing the network. Like open-access, this access method also has the operational and inconvenient problem for the users - manually inputting access information whenever connecting to the network. To overcome this problem in both schemes, we propose two improved wireless network access methods: 1) the implementation of automatic AP connection mechanism using user-authorization and iBeacon messages, and 2) SSID registration form for public wireless networks.

Part II A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구II)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.5-14
    • /
    • 1991
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it Is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the latter fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First, We are going to look history of the fire protection system and change course of that with the year and facility. Second. We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have to reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use count about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF