• Title/Summary/Keyword: Automatic Testing

Search Result 400, Processing Time 0.03 seconds

Study on simultaneous determination of aromatic material causing allergic in children's products by GC-MSD (GC-MSD를 이용한 어린이 제품 중 알러지 유발 방향성 물질의 동시분석법 연구)

  • Ko, Kyeong Mok;Rhu, Chan Joo;Ko, Byeong Rae;Lee, Seok Ki
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.134-142
    • /
    • 2020
  • Twenty-one allergy-induced aromatic material in children's products were analyzed using gas chromatography mass spectrometer(GC-MSD). The analytes were extracted using an automatic Soxhlet extractor, centrifuged for 10 minutes in a fast freezing centrifuge, and the supernatant was filtered with a syringe filter and then transferred into a 2 mL vial and injected in a split mode. In the established condition, the calibration curve showed linearity with a determination coefficient of 0.9981 or more. Sensitivity was 0.3145 ~ 1.6757, which showed a fairly wide range of sensitivity for each substance. The detection limit of the device was 0.0016 ~ 0.0423 ㎍/mL and the maximum detection limit was less than 0.05 ㎍/mL. The method detection limit ranged from 0.0030 ~ 0.0589 ㎍/mL. In addition, the limit of quantification ranged from 0.0096 to 0.1876 ㎍/mL, with precision ranging from 0.41 to 10.49 % and accuracy ranging from 83 to 116 %. The analytical method developed in this study was applied to commercial products.

The development of the Ionizer using clean room (청정환경용 정전기 제거장치 개발)

  • Jeong, Jong-Hyeog;Woo, Dong Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.603-608
    • /
    • 2018
  • Although the voltage-applied discharge method is most widely used in the semiconductor and display industries, periodic management costs are incurred because the method causes defects due to the absorption of ambient fine dust and causes emitter tip contamination due to the discharge. The emitter tip contamination problem is caused by the accumulation of fine particles in ambient air due to the corona discharge of the ionizer. Fuzzy ball generation accelerates the wear of the emitter tip and deteriorates the performance of the ionizer. Although a mechanical cleaning method using a manual brush or an automatic brush is effective for contaminant removal, it requires management of additional mechanical parts by the user. In some cases, contaminants accumulated in the emitter may be transferred to the wafer or product. In order to solve this problem, we developed an ionizer for a clean environment that can remove the pencil-type emitter tip and directly ionize the surrounding gas molecules using the tungsten wire located inside the ion tank. As a result of testing and certification by the Korea Institute of Machinery and Materials, the average concentration was $0.7572particles/ft^3$, the decay time was less than two seconds, and the ion valance was 7.6 V, which is satisfactory.

A Red Ginseng Internal Measurement System Using Back-Projection (Back-Projection을 활용한 홍삼 내부 측정 시스템)

  • Park, Jaeyoung;Lee, Sangjoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.10
    • /
    • pp.377-382
    • /
    • 2018
  • This study deals with internal state and tissue density analysis methods for red ginseng grade determination. For internal measurement of red ginseng, there have been various studies on nondestructive testing methods since the 1990s, It was difficult to grasp the most important inner hole and inside whites in the grading. So in this study, we developed a closed capturing device for infra-red illumination environment, and developed an internal measurement system that can detect the presence and diameter of inner hole and inside whites. Made devices consisted of infrared lights with a high transmission rate of red ginseng in 920 nanometer wave band, a infra-red camera and a Y axis actuator with a red ginseng automatically controlled focus on the camera. The proposed algorithm performs an auto-focus system on the Y-axis actuator to automatically adjust the sharp focus of the object according to the size and thickness. Then red ginseng is rotated $360^{\circ}$ at $1^{\circ}$ intervals and 360 total images are acquired, and reconstructed as a sinogram through Radon transform and Back-projection algorithm was performed to acquire internal images of red ginseng. As a result of the algorithm, it was possible to acquire internal cross-sectional image regardless of the thickness and shape of red ginseng. In the future, if more than 10,000 different shapes and sizes of red ginseng internal cross-sectional image are acquired and the classification criterion is applied, it can be used as a reliable automated ginseng grade automatic measurement method.

A Study on the Usefulness of Backend Development Tools for Web-based ERP Customization (Web기반 ERP 커스터마이징을 위한 백엔드 개발도구의 유용성 연구)

  • Jung, Hoon;Lee, KangSu
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.53-61
    • /
    • 2019
  • The risk of project failure has increased recently as ERP systems have been transformed into Web environments and task complexity has increased. Although low-code platform development tools are being used as a way to solve this problem, limitations exist as they are centered on UI. To overcome this, back-end development tools are required that can be developed quickly and easily, not only from the front development but also from a variety of development sources produced from the ERP development process, including back-end business services. In addition, the development tools included within existing ERP products require a lot of learning time from the perspective of beginner and intermediate developers due to high entry barriers. To address these shortcomings, this paper seeks to study ways to overcome the limitations of existing development tools within the ERP by providing customized development tool functions by enhancing the usability of ERP development tools suitable for each developer's skills and roles based on the requirements required by ERP development tools, such as reducing the time required for querying, automatic binding of data for testing for service-based units, and checking of source code quality.

Effects of Spray Times and Ventilation Method on the Seedling Growth of Fruit Vegetables (관수회수 및 송풍처리가 과채류의 묘 생장에 미치는 영향)

  • Kim Chang-Soo;Min Byeong-Ro;Kim Wong;Kim Dong-Woo;Seo Kwang-Wook;Lee Beom-Seon;Lee Dae-Weon
    • Journal of Bio-Environment Control
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • A multipurpose operating system was developed to adjust both spray times and ventilation method without a configuration of the moving path and the type of the greenhouse. The multipurpose working system proved to be a reliable system for testing the growth quality of the fruit vegetables in the greenhouse. The results are as follows. The first leaf, diameter of a stem, leaf area, and average stem diameter in the Cucumber seedling growth were repressed by high-speed ventilation, but was not repressed by spray times. The first leaf in the Tomato seedling growth was repressed as ventilation velocity was high, but the average stem diameter was not repressed. While the Tomato was given water three times a day, the diameter of a stem and the leaf area were increased as ventilation speed became higher. However, those were different other factors. The Tomato leaf area was larger when given water twice a day than that in hand spray, but showed no difference with ventilation speed. The first leaf, the diameter of a stem and the leaf area of a Red pepper were lower in automatic spraying with ventilation than those in hand spray.

Whole-body Management System using Ultra-Low Temperature Cyclical Cooling Method Combined with IT Technology (IT 기술을 접목한 초저온 순환 냉각 방식의 전신 관리 시스템)

  • Kim, Joo-Ho;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.673-676
    • /
    • 2020
  • In this paper, we propose a whole-body management system using ultra-low temperature cyclical cooling method combined with IT technology. The proposed system has the following characteristics. First, it minimizes maintenance costs by circulating nitrogen gas cooled by ultra-low temperature inside the controller. Secondly, based on the information measured by the temperature sensor and oxygen concentration sensor, nitrogen gas is supplied to provide safe ultra-low temperature whole-body management. Thirdly, after entering the user's height, it provides convenient, ultra-low temperature whole-body care that can be controlled using an automatic lift. Fourth, it provides an easy-to-access, easy-to-manage GUI and a manager-only web program for whole-body management system operation. The results tested by the authorized testing agency to assess the performance of the proposed system were measured in the range of ±5%, the world's highest temperature sensor accuracy, and a range of -110℃ to -150℃ greater than the world's highest whole-body management temperature range(-110℃ ~ -140℃). In addition, humidity was measured at less than 40%, the world's highest, and oxygen concentration was more than 18%, the world's highest. Therefore, the effectiveness of the methods proposed in this paper was demonstrated because they produced the same results as the world's highest levels.

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

The Study of RIA Development Direction using Suggestion System (제안제도를 활용한 RIA 발전 방향에 관한 연구)

  • Shin, Young-Kyun;Chun, Jun-Hong;Kim, Yeon-Ok;Lee, Seon-Ho;Kim, Seong-Ho;Yoo, Seon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.106-112
    • /
    • 2011
  • Purpose: Until now, the process was improved by the needs of experimenters personally. But recently, suggestion system in hospital has been activated in various ways. So the department of nuclear medicine laboratory is also aware of the need of operation improvement using suggestion system. It is intend to assist in the development by sharing excellent suggestion cases with other hospitals. Material & Method: A total of 124 suggestion cases from January 2007 to March 2010 were analyzed. Suggestion cases were divided into customer satisfaction, cost reduction, improved testing methods, equipment, environmental improvement, and computational system. Result: Suggestion cases of environmental improvement and computational system were accounted for 26.6% as 33 cases, respectively. Suggestion for customer satisfaction is 25.8% as 32 in a total of 124 cases. Conclusion: Activation of the awareness of operation improvement is induced by suggestion system. By securing system of operation improvement, employees' ideas can lead to the production and systematization. Furthermore, it enhances hospital competitiveness and promotes the development of the hospital.

  • PDF

Generation and Detection of Cranial Landmark

  • Heo, Suwoong;Kang, Jiwoo;Kim, Yong Oock;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.26-32
    • /
    • 2015
  • Purpose When a surgeon examines the morphology of skull of patient, locations of craniometric landmarks of 3D computed tomography(CT) volume are one of the most important information for surgical purpose. The locations of craniometric landmarks can be found manually by surgeon from the 3D rendered volume or 2D sagittal, axial, and coronal slices which are taken by CT. Since there are many landmarks on the skull, finding these manually is time-consuming, exhaustive, and occasionally inexact. These inefficiencies raise a demand for a automatic localization technique for craniometric landmark points. So in this paper, we propose a novel method through which we can automatically find these landmark points, which are useful for surgical purpose. Materials and Methods At first, we align the experimental data (CT volumes) using Frankfurt Horizontal Plane (FHP) and Mid Sagittal Plane(MSP) which are defined by 3 and 2 cranial landmark points each. The target landmark of our experiment is the anterior nasal spine. Prior to constructing a statistical cubic model which would be used for detecting the location of the landmark from a given CT volume, reference points for the anterior nasal spine were manually chosen by a surgeon from several CT volume sets. The statistical cubic model is constructed by calculating weighted intensity means of these CT sets around the reference points. By finding the location where similarity function (squared difference function) has the minimal value with this model, the location of the landmark can be found from any given CT volume. Results In this paper, we used 5 CT volumes to construct the statistical cubic model. The 20 CT volumes including the volumes, which were used to construct the model, were used for testing. The range of age of subjects is up to 2 years (24 months) old. The found points of each data are almost close to the reference point which were manually chosen by surgeon. Also it has been seen that the similarity function always has the global minimum at the detection point. Conclusion Through the experiment, we have seen the proposed method shows the outstanding performance in searching the landmark point. This algorithm would make surgeons efficiently work with morphological informations of skull. We also expect the potential of our algorithm for searching the anatomic landmarks not only cranial landmarks.

Evaluation of Hydrogen Properties on Mg2NiHx-Graphene Composites by Mechanical Alloying (기계적 합금화법으로 제조한 Mg2NiHx-Graphene 복합재료의 수소화 특성 평가)

  • Lee, Young-Sang;Lee, Soo-Sun;Lee, Byung-Ha;Jung, Seok;Hong, Tae-Whan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.1
    • /
    • pp.19-27
    • /
    • 2014
  • Mg hydride has a high hydrogen capacity (7.6%), at high temperature, and is a lightweight and low cost material, thus it a promising hydrogen storage material. However, its high operation temperature and very slow reaction kinetics are obstacles to practical application. In order to overcome these disadvantages of Mg hydride, graphene powder was added to it. The addition of graphene has been shown to reduce the operating temperature of dehydrogenation. Moreover, in this report the environmental aspects of $MgH_x$-Graphene composites are investigated by means of the environmental life cycle assessment (LCA) method. $MgH_x$-Graphene mixture was prepared by hydrogen induced mechanical alloy (HIMA). The synthesized powder was characterized by XRD(X-ray Diffraction). The hydrogenation behaviors were evaluated by using a Sievert's type automatic PCT apparatus. Such evaluation of Materials also conducted in the LCA. From the result of P-C-T(Pressure-Composition-Temperature) curves, the $MgH_x$-3wt.% graphene composite was evaluated as having a 5.86wt.% maximum hydrogen storage capacity, at 523K. From absorption kinetic testing, the $MgH_x$-7wt.% graphene composite was evaluated as having a maximum 6.94wt.%/ms hydrogen absorption rate, at 573K. Environment evaluation results for the $MgH_x$-graphene composites and other materials indicated environmental impact from the electric power used and from the materials themselves.