• 제목/요약/키워드: Automatic Test Equipment

검색결과 189건 처리시간 0.025초

UAT ADS-B의 국내 적용방안 (Application of UAT ADS-B)

  • 김경호;최성호;백호종;이금진;문우춘
    • 한국항공운항학회지
    • /
    • 제20권2호
    • /
    • pp.26-31
    • /
    • 2012
  • A new operational concept for the CNS/ATM using the digital data communication technology and satellite navigation system is being implemented globally and the United States is the first country to apply UAT ADS-B system for general aviation. Korea also has plan to build ADS-B system for aeronautical surveillance to monitor low altitude flight of light aircraft and ultra-light flying device and the research to develop UAT ADS-B equipment is being carried out. This paper presents the application method of UAT ADS-B to support test operation with case study of foreign UAT ADS-B operation and survey of domestic environment.

레이다 도파관의 작동상태점검법에 관한 연구 (A Studyu on the Waveguide Running Condition Inspection of Radar)

  • 류대근
    • 한국항해학회지
    • /
    • 제5권2호
    • /
    • pp.41-47
    • /
    • 1981
  • Many new radar techniques have appeared on the electronic scene in recent years, such as a variety of automatic computer processing. However, even with the advent of these sophisticated radar techniques, an old problem continues to plague all radars: the problem of transmission line losses. With the higher performance required today, the Waveguide testing and trouble-shooting techniques remain essentially unchanged in principle. This paper dealt with the rf pulse "Time-domain Reflectometry" to inspect radar wave-guide system and compared with the conventional methods. During the investigation, it was verified that the pulsed TDR for wave-guide is superior to the conventional methods; 1. Disassembling is not needed to locate the discontinity points and measure the reflections of trobled points. 2. The results of the data are more precise. 3. The condition of individual component is able to the photographed and recorded permanently. 4. Since rf pulse TDR is based on the well-known basic radar principle, such a test set requires the minimum of training to operate. With the level of transmission line problems, the prospect of increasing complexity of equipment, and no relief in sight, the benifits must be emphasizied to adopt such a testing procedure.procedure.

  • PDF

자율운항선박의 회피 항로 적용을 위한 항로 추종 알고리즘 개발 (Development of Route following Algorithm for Application in Collision Avoidance Routes of Maritime Autonomous Surface Ship)

  • 차승태;정유준
    • 한국항해항만학회지
    • /
    • 제47권6호
    • /
    • pp.386-393
    • /
    • 2023
  • 최근 자율 항해 기술의 수요가 높아져 관련 연구도 증가하는 추세이다. 자율운항선박들은 일반적으로 계획 항로를 추종하여 항해하는 도중 위험 상황에 따라 회피항로를 산출하고 산출된 항로를 추종한다. 항로 추종에는 일반적으로 자동조타장치가 활용되며, 자동조타장치의 운용 방식 중, 항로제어 모드를 자율운항선박에 적용하는 것이 현 시점에서 가장 적절한 방안이다. 따라서 본 논문에서는 자동조타장치의 항해제어 모드를 활용해 회피 항로를 적용하기 위한 항로 추종 알고리즘을 개발한다. 알고리즘은 직선구간과 선회구간을 구분하여 개발하였으며, 이에 대한 성능을 검증하기 위해 국제 인증을 취득한 시뮬레이터 장비를 사용하여 관련 국제 표준인 IEC 62065에서 제시한 성능을 만족하기 위한 성능 시험을 진행하였다. 성능 검증 결과로 보았을 때, 선박이 항로를 추종함에 있어서 선박과 항로 사이의 직선거리를 나타내는 Cross Track Error가 IEC 62065에서 제시하는 성능 기준을 만족하는 것을 확인하였다.

상수도의 수질관리와 타소소독의 잔류효과에 관한 연구 (Study on the Water Quality Control of Water Supply the Reside: Effects of Chlorinations)

  • 유귀현
    • 환경위생공학
    • /
    • 제6권2호
    • /
    • pp.33-47
    • /
    • 1991
  • 1. Water supply treatment plants personnel could not test the water quality control, because most of them rely on the provincial health laboratories about water quality rely rant test. However, in future, plants have to been provided the facilities and equipment of water quality laboratory. 2. Chlorination methods are 89.5% of liquid chlorine and 10.5% of solid chlorine, and the cost per 1 $\m^{3}$ of chlorination is about 1.30 won which chlorination cost is very cheap as 1/142 of drinking water production cost. Input method of chlorine is 35% of automatic method, 56% of semi-automatic, and 9% of other methods, and this is no problem 3. Residual effects of chlorination, in the case of distilled water as a standardized material and 0.2 ppm of seperated residual chlorine, were continued 32 hours in $0^{\circ}C$, and 25 hour in $20^{\circ}C$, of water temperature and in the case of 0.4 ppm of seperated residual chlorine were continued 47 hours in $0^{\circ}C$ and 23 hours in $20^{\circ}C$. 4. In the case of 4 ppm of seperated residual chlorine, residual effects were continued 23 hours in $5^{\circ}C$, 90 hours in $10^{\circ}C$, 78 hours in $15^{\circ}C$, and 60 hours in $20^{\circ}C$ : by the temper; lure of water, continuing residual effects of chlorination are different, so we have to car for the warm season chlorination in the hider temperature. 5. Chlorination effects of drinking waters in the case of 0.4 ppm of seperated residual chlorine were continued 237 hours in $22^{\circ}C$ water : and in the case of rechlorination as 4 ppm of residual chlorine, continued 71 hours in $22^{\circ}C$ water.

  • PDF

유한요소해석을 이용한 Gantry Robot의 동특성 및 측정 결과와의 상관관계 연구 (A Study for the Dynamic Characteristics and Correlation with Test Result of Gantry Robot based on Finite Element Analysis)

  • 고만수;권순기;이석
    • 디지털융복합연구
    • /
    • 제13권1호
    • /
    • pp.269-274
    • /
    • 2015
  • IT 산업의 발달로 AOI 장비의 보급이 확산되고 있으며, 장비의 사용되는 카메라의 높은 해상도를 요구하고 있다. 높은 해상도를 얻기 위해 카메라의 중량이 증가되고 있으며, 그로 인해 진동변위가 커지게 되어 촬상에 문제가 생기고 제어 또한 어려워지고 있다. 본 연구에서는 유한요소 해석프로그램인 NX/NASTRAN을 이용하여 카메라가 관성에 의한 충격력을 받을 때의 과도응답분석을 해 보았다. 또한 Laser Interferometer 측정 결과와의 상관관계 분석을 통하여 향후 AOI의 구조 개선 시, 유한요소해석으로 설계의 신뢰성을 검증할 수 있도록 하기 위한 해석모델을 개발하였다.

종합병원 진단검사의학과 검사실의 시설 현황 조사 - 300 병상 미만 병원을 중심으로 (A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on less than three hundred bed hospitals)

  • 김영애
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.15-23
    • /
    • 2019
  • Purpose: As the medical laboratories in general hospitals have made an efforts on quality management and employee health, they recognized the need of design guideline for clinical laboratory. As laboratories are prohibited to patients, their environments are becoming more congested and deteriorated as time goes by. So, this study investigates the current status of facility and equipment of laboratory medicine focusing on less than three hundred patient bed hospitals, and searches the improving matters. Methods: Questionnaires to technologist captains and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 18 answers have been analysed statistically by MS Excel program. Results: The result of this study can be summarized into followings. Clinical laboratory functions are all hematology, clinical chemistry, immunology, transfusion and urine microscopy, and except for three including microbiology for infection and bio safety level. Average man power of lab are 12.3 man including lab director and captain. Patient bed number, space area and total specimen numbers are not correlated with each other, but specimen numbers and employee number are correlated with. Work space distances are usually good, but exit distances are not adequate for escape owing to obstacles. Specimen delivery system by courier, test method by automatic analyzer, access floor for exposed plumbing and electricities are more practical. Open lab layed out in the center and lab support layed peripheral in space diagram. Lab space configuration by SD method showed that lab support area and employee support area are dissatisfied. Implications: Specialized hospital and yearly total specimen numbers are related to the space area and organization for laboratory planning and design.

무인항공기 시스템을 활용한 선박 식별 및 도시 시스템 개발 (Development of Ship Identification and Display System using Unmaned Aerial Vehicle System)

  • 최성민;고윤호;강영신
    • 한국항공우주학회지
    • /
    • 제44권10호
    • /
    • pp.862-870
    • /
    • 2016
  • 선박의 안전한 운항과 자동입출항을 관리하기 위해서 사용되는 선박위치 발신장치(AIS, V-PASS)는 모든 선박에 의무적으로 장착하는 표준장비이다. 선박위치 발신장치를 활용한 선박식별 시스템을 항공기에 탑재하여 대형 어업지도선이나 경비함 등의 선박 및 지상 시스템에서 선박식별정보를 수신할 수 있게 되면 해양감시와 재난대응을 신속하게 수행할 수 있다. 본 논문은 항공기용 통합 선박식별 장치를 활용한 선박식별 및 도시 시스템의 개발 및 비행시험결과와 향후의 활용방안에 대해 기술하였다.

Multi-Point 2-D FFT를 이용한 TFT-LCD Mura 검출 알고리즘 (TFT-LCD Mura Detection Algorithm Using Multi-point 2-D FFT)

  • 장영범;김한진
    • 한국산학기술학회논문지
    • /
    • 제11권4호
    • /
    • pp.1278-1284
    • /
    • 2010
  • 이 논문에서는 TFT-LCD의 제조공정에서 발생하는 mura를 효율적으로 검출하는 multi-point FFT를 기반으로 한, 2차원 FFT를 이용하는 새로운 전기적인 검출 방식을 제안한다. TFT-LCD의 mura 패턴은 어느 일정한 영역을 갖고 있으므로 어느 한 라인에서 관찰하면 sin 파의 모양으로 관찰된다. Mura의 모양은 원, 가로 타원, 세로 타원으로 분류할 수 있으며 2-D FFT 변환을 통하여 일정한 문턱치와 비교하면 mura를 쉽게 검출할 수 있음을 보인다. 실험영상의 simulation을 통하여 제안 알고리즘이 다양한 크기의 mura 패턴을 효과적으로 검출할 수 있음을 보였다. 따라서 제안된 알고리즘은 TFT-LCD mura의 자동 검사 시스템에 이용될 수 있을 것이다.

이중화 자동복구 보안기능이 구비된 배전반의 보안성 평가를 위한 테스트베드 구성에 대한 고찰 (An Inquire into Test Bed Compositions in Assessing the Security of a Soft Redundancy Sub-Station System with Auto-Restoration)

  • 최형석;진창기;배기덕
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.99-109
    • /
    • 2012
  • Sub-station, key equipment in electric power infrastructure, are being exposed to increasing risk of hacking. For this, soft redundancy sub-station system needs to be formulated with automatic restoration mechanism. For this it is important to assess the reliability of the applicable range of data that are used in actual system operation, as well as the methods and findings of the tests. At the same time performance of soft redundancy system and total security mechanism, which are aligned for the protection of the sub-station, need to be tested. For testing the above-mentioned, this paper presented a viable formation of a soft redundancy practical VPN system within a panel to protect the latter from hacking or cracking incidences, and conducts a test to check if the considered system actually serves the protection function in the actual operation setting, gathering evidence from the data from the testing of the actual performance of the system as well as of emergency scenario simulation operations. Because tested soft-redundancy & restorative sub-station system is expected to be widely applicable for various cases such as Smart-grid or electricity IT system, where VPN with enhanced level of security is required.

만타형 UUV의 제어기 설계에 관한 연구 (A Study of the Control System on the Manta-type UUV)

  • 김형동;김준영;김시홍;이승건
    • 한국항해항만학회지
    • /
    • 제35권5호
    • /
    • pp.359-363
    • /
    • 2011
  • 본 연구에서는 만타 형상을 가진 무인잠수정(Manta-type unmanned underwater test vehicle)의 제어 성능 평가를 수행 하였다. 제어 방법으로서 PID제어, Fuzzy 제어가 적용되었으며, 6자유도 운동 수학모델과 Matlab Simulink을 이용하여 조종 운동 시뮬레이션을 수행하였다. 또한, 설계된 제어기로 수심제어 및 방위제어에 적용하여, 조류의 외란 하에서 제어 성능을 평가하였다.