• Title/Summary/Keyword: Automatic Setting

Search Result 185, Processing Time 0.03 seconds

On-line Automatic Geometric Correction System of Landsat Imagery (Landsat 영상의 온라인 자동 기하보정 시스템)

  • Yun, YoungBo;Hwang, TaeHyun;Cho, Seong-Ik;Park, Jong-Hyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.4
    • /
    • pp.15-23
    • /
    • 2004
  • In order to utilize remote sensed images effectively, it is necessary to correct geometric distortion. Geometric correction is a critical step to remove geometric distortions in satellite images. For geometric correction, Ground Control Points (GCPs) have to be chosen carefully to guarantee the quality of geocoded satellite images, digital maps, GPS surveying or other data. Traditional approach to geometric correction used GCPs requires substantial human operations. Also that is necessary much time and manpower. In this paper, we presented an on-line automatic geometric correction by constructing GCP Chip database. The Proposed on-line automatic geometric correction system is consists of four part. Input image, control the GCP Chip, revision of selected GCP, and output setting part. In conclusion, developed system reduced the processing time and energy for tedious manual geometric correction and promoted usage of Landsat imagery.

  • PDF

Setting of the Operating Conditions of Stereo CCTV Cameras by Weather Condition

  • Moon, Kwang;Pyeon, Mu Wook;Lee, Soo Bong;Lee, Do Rim
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.6
    • /
    • pp.591-597
    • /
    • 2014
  • A wide variety of image application methods, such as aerial image, terrestrial image, terrestrial laser, and stereo image point are currently under investigation to develop three-dimensional 3D geospatial information. In this study, matching points, which are needed to build a 3D model, were examined under diverse weather conditions by analyzing the stereo images recorded by closed circuit television (CCTV) cameras installed in the U-City. The tests on illuminance and precipitation conditions showed that the changes in the number of matching points were very sensitively correlated with the changes in the illuminance levels. Based on the performances of the CCTV cameras used in the test, this study was able to identify the optimal values of the shutter speed and iris. As a result, compared to an automatic control mode, improved matching points may be obtained for images filmed using the data obtained through this test in relation to different weather and illuminance conditions.

Application of AIG Implemented within CLASS Software for Generating Cognitive Test Item Models

  • SA, Seungyeon;RYOO, Hyun Suk;RYOO, Ji Hoon
    • Educational Technology International
    • /
    • v.23 no.2
    • /
    • pp.157-181
    • /
    • 2022
  • Scale scores for cognitive domains have been used as an important indicator for both academic achievement and clinical diagnosis. For example, in education, Cognitive Abilities Test (CogAT) has been used to measure student's capability in academic learning. In a clinical setting, Cognitive Impairment Screening Test utilizes items measuring cognitive ability as a dementia screening test. We demonstrated a procedure of generating cognitive ability test items similar as in CogAT but the theory associated with the generation is totally different. When creating cognitive test items, we applied automatic item generation (AIG) that reduces errors in predictions of cognitive ability but attains higher reliability. We selected two cognitive ability test items, categorized as a time estimation item for measuring quantitative reasoning and a paper-folding item for measuring visualization. As CogAT has widely used as a cognitive measurement test, developing an AIG-based cognitive test items will greatly contribute to education field. Since CLASS is the only LMS including AIG technology, we used it for the AIG software to construct item models. The purpose of this study is to demonstrate the item generation process using AIG implemented within CLASS, along with proving quantitative and qualitative strengths of AIG. In result, we confirmed that more than 10,000 items could be made by a single item model in the quantitative aspect and the validity of items could be assured by the procedure based on ECD and AE in the qualitative aspect. This reliable item generation process based on item models would be the key of developing accurate cognitive measurement tests.

Development of machine learning model for automatic ELM-burst detection without hyperparameter adjustment in KSTAR tokamak

  • Jiheon Song;Semin Joung;Young-Chul Ghim;Sang-hee Hahn;Juhyeok Jang;Jungpyo Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.100-108
    • /
    • 2023
  • In this study, a neural network model inspired by a one-dimensional convolution U-net is developed to automatically accelerate edge localized mode (ELM) detection from big diagnostic data of fusion devices and increase the detection accuracy regardless of the hyperparameter setting. This model recognizes the input signal patterns and overcomes the problems of existing detection algorithms, such as the prominence algorithm and those of differential methods with high sensitivity for the threshold and signal intensity. To train the model, 10 sets of discharge radiation data from the KSTAR are used and sliced into 11091 inputs of length 12 ms, of which 20% are used for validation. According to the receiver operating characteristic curves, our model shows a positive prediction rate and a true prediction rate of approximately 90% each, which is comparable to the best detection performance afforded by other algorithms using their optimized hyperparameters. The accurate and automatic ELM-burst detection methodology used in our model can be beneficial for determining plasma properties, such as the ELM frequency from big data measured in multiple experiments using machines from the KSTAR device and ITER. Additionally, it is applicable to feature detection in the time-series data of other engineering fields.

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

A Study on Dose Reduction Method according to Slice Thickness Change using Automatic Exposure Controller and Manual Exposure in Intervention (인터벤션에서 자동노출제어장치와 수동노출 사용 시 두께 변화에 따른 선량감소 방안 연구)

  • Hwang, Jun-Ho;Jung, Ku-Min;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.115-122
    • /
    • 2018
  • We aims to perform comparative analysis on the dose area and image qualities varying on the slice thickness when using Automatic Exposure Controller (AEC) and manual exposure; thus, it wants to suggest a measure to reduce exposure dose by setting the optimal examination condition for each slice thickness. The method was to set the thickness as Thin, Normal, and Heavy adult and evaluate the dose area, spatial resolution, low contrast resolution, Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) according to each slice thickness by using the AEC and the manual exposure controller. The dose area according to each slice thickness all increased both when using the AEC and the manual exposure. However, the manual exposure showed lower dose area product than the AEC. Spatial resolutions and low contrast resolutions were all observed to be higher than the evaluation standard. Also, the SNR and CNR of each thickness all increased when using the AEC. When using the manual exposure, SNR and CNR increased in all cases other than the Heavy Adult. Consequently, the Thin and Normal Adult showed dose reduction about 2 times when using the manual exposure controller, while ensuring the image quality. Heavy adult was able to maintain good image quality by using AEC.

An Internet Stopper Using ARP Spoofing with Automatic Node Identification (자동 노드 인식 기능을 갖는 ARP 스푸핑을 이용한 인터넷 차단기)

  • Jung, In-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.93-106
    • /
    • 2011
  • In this paper we describe an efficient and easy to use internet stopper, which is called AINS (Automatic Internet Stopper), which uses ARP spoofing scheme. Instead of forwarding packets to router for the case of hacking, in ARP spoofing, the AINS ignores all the packets so that internet stopping operates. The AINS program needs to be installed only in manager computer that does not require additional agent program. In addition to setting manually the stopping computer list, it is able to indentify network nodes automatically by analyzing broadcasting packets. The experimental results show that less than 4 secs for spoofing interval is enough for blocking internet usage regardless the number of computers and therefore network overhead is negligible. The AINS can indentify and control network nodes not only on same subnet but also on different subnet only if they are connected onto same ethernet switch physically. It is being used for an efficient tool for controling internet usage of university computer laboratory and also for an efficient network management.

An Automatic Rhythm and Melody Composition System Considering User Parameters and Chord Progression Based on a Genetic Algorithm (유전알고리즘 기반의 사용자 파라미터 설정과 코드 진행을 고려한 리듬과 멜로디 자동 작곡 시스템)

  • Jeong, Jaehun;Ahn, Chang Wook
    • Journal of KIISE
    • /
    • v.43 no.2
    • /
    • pp.204-211
    • /
    • 2016
  • In this paper, we propose an automatic melody composition system that can generate a sophisticated melody by adding non-harmony tone in the given chord progression. An overall procedure consists of two steps, which are the rhythm generation and melody generation parts. In the rhythm generation part, we designed new fitness functions for rhythm that can be controlled by a user setting parameters. In the melody generation part, we designed new fitness functions for melody based on harmony theory. We also designed evolutionary operators that are conducted by considering a musical context to improve computational efficiency. In the experiments, we compared four metaheuristics to optimize the rhythm fitness functions: Simple Genetic Algorithm (SGA), Elitism Genetic Algorithm (EGA), Differential Evolution (DE), and Particle Swarm Optimization (PSO). Furthermore, we compared proposed genetic algorithm for melody with the four algorithms for verifying performance. In addition, composition results are introduced and analyzed with respect to musical correctness.

Implementation of the automatic switching device for the voice communications between heterogeneous devices (이종 기기 간 음성통신을 위한 자동전환장치의 구현)

  • Lew, Chang-Guk;Lee, Bae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.12
    • /
    • pp.1321-1328
    • /
    • 2015
  • A radio is a half-duplex voice communication method using the PTT(: Push To Talk), occupy a single line calls during transmission. As an interface between the telephone and the radio, UHF and VHF, for voice communication between the different heterogeneous devices, A device automatically switches between the two devices is required. Therefore, in accordance with the performance of the voice switching apparatus for detecting a voice to be transmitted from an input signal, loss of the audio signal to be transmitted is subjected to Significant influence. Conventional method has the problem responding to noise by setting the level through simple means of amplitude of input signal, in other words, the energy level of the input signal. This paper, by using the audio signal processing techniques, this discriminated what the voice is among the input signal and substantiated a device for the automatic voice transmission between heterogeneous devices. With this proposal, I was confirmed of improvement of performance in the automatic voice switching device, could perform loss-less transmission of voice between heterogeneous devices.

Effects of Exposure Dose Reduction by Optimization of Automatic Exposure Control Factors in Digital Radiographic Examination of Paranasal Sinus (부비동 디지털 엑스선검사에서 자동노출제어 조절인자의 최적화를 통한 조사선량 감소 효과)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.173-181
    • /
    • 2021
  • The purpose of this study was to reduce dose while maintaining image quality during digital radiographic examination of paranasal sinus by using the automatic exposure control (AEC) system. The tube voltage was set as six stages that increased by about 10 kVp to 70 kVp, 81 kVp, 90 kVp, 102 kVp, 109 kVp and 117 kVp. And then the AEC system conditions were consisted of 9 setting environments, that change mode of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). We measured automatically exposed tube current (mAs) under 54 conditions with combined these, and assessed SNR and PSNR through the acquired images. In addition, four radiologists performed a qualitative assessment of the acquired images for each combination on a five-point scale of the Likert. As a result, the lowest dose and the highest values of SNR and PSNR in images with a qualitative assessment more than 4 point were the AEC control factors of 90 kVp, S800, D2.5. We applied this condition to the clinical trial, it showed an effect of 83.1% reduction in exposure radiation dose (mR). Therefore, AEC system could be used as dose reduction technology if it understood and used related regulatory factors and physical characteristics.