• Title/Summary/Keyword: Automatic Installation System

Search Result 190, Processing Time 0.026 seconds

Implementation of Aeronautical Surveillance Transceiver using AIS based on ADS-B Concepts (선박자동식별장치를 이용한 ADS-B 개념 기반의 항공감시용 송수신기의 구현)

  • Song, Jae-Hoon;Oh, Kyung-Ryoon;Kim, Jong-Chul;Lee, Jang-Yeon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.06a
    • /
    • pp.19-20
    • /
    • 2009
  • International Maritime Organization(IMO) recommends the installation of an Automatic Identification System(AIS) according to requirements by SOLAS Chapter 5 to avoid maritime collision. AIS provides traffic information of other ships that may be used for maritime traffic control, SAR(Search and Rescue) and collision avoidance to apply safety management. In this paper, preliminary results to implement an aeronautical surveillance transceiver using AIS transceiver based on ADS-B concepts are described. Although altitude information is not required for AIS since the AIS is operated at MSL(Mean Sea Level), altitude information can be extracted by a GPS chip-set in the ALS transceiver. ADS-B transceiver is implemented by defining a surveillance message format including the altitude information and modifying SOTDMA protocol. Ground tests and flight tests are performed to validate the implementation results.

  • PDF

Development of Y Strainer Type Automatic Flow Rate Regulating Valve (Y 스트레이너형 자동 정유량 조절 밸브의 개발)

  • Yoon, Joon-Yong;Kwon, Woo-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.1 s.40
    • /
    • pp.49-55
    • /
    • 2007
  • An 'Y' strainer type automatic flow rate regulating valve, which functions are to remove impurities from hot water inside the pipe and to maintain a constant flow rate regardless of variations of the differential pressure between valve inlet and outlet at the same time, is developed for distributing hot water equally to several pipes with district heating or central heating system. Numerical analysis of the three dimensional turbulent flow field in a valve shape is carried out to confirm the flow field whether the designed regulator shape is acceptable or not. The final developed valve improves installation time and cost and maintenance ability comparing with set-up 'Y' strainer and regulator separately. Tolerance for the nominal flow rate is also satisfied within ${\pm}5%$.

Development of Pump Selection Computer Program with Pump Performance Viscosity Correction Function (점도보정을 고려한 펌프선정 프로그램 개발)

  • Kim, Jin-Kwon;Jeon, Sang-Gyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.189-192
    • /
    • 2004
  • Utilizing pump selection softwares is becoming a new general trend in pump industries, substituting the old fashioned pump catalogs. One of the most powerful pump selection softwares is developed, which features pump performance viscosity correction function as well as pump selection based on the exact pump performance curves, NPSH warning, automatic determination of impeller diameter cutting to meet the customer's performance specification, performance simulation for the rpm and diameter variation, standard motor recommendation according to the motor standards and enclosure types and automatic pump datasheet generation for sales submission, automatic pump drawings and dimension generation for installation check and part preparation. This software provides pump distributors and customers with a quick, easy and exact pump selection, various performance curves review (system curves, performance curve of series or parallel operation) of the selected pumps.

  • PDF

A Performance Improvement of Exciter Control System of Synchronous Generator using Transient Response Compensator (과도 응답 보상기를 가지는 동기발전기의 고성능 여자 제어시스템)

  • Lee, Dong-Hee;Wang, Huijun;Kim, Tae-Hyoung;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.82-89
    • /
    • 2007
  • AVR(Automatic Voltage Regulator) of exciter control system in AC generator controls voltage and current according to load and terminal voltage variations in order to remain at the bus voltage. The output characteristics of main generator is dependent on the control performance of AVR. This paper presents the PWM type exciter system with transient response compensator for robust control of load variations. Additional transient response compensator generates compensation signal for load variation. So the proposed excitation control system has fast dynamic response in transient period and can control terminal voltage constantly. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

A Study on Excitation System for Synchronous Generator Using Two State Three Phase PWM AC/DC Converter (2단 3상 PWM AC/DC 컨버터를 이용한 동기발전기 여자제어시스템)

  • Lee, Sang-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.96-106
    • /
    • 2007
  • The terminal voltage of a synchronous generator is maintained by the field current control of excitation system. Generally AC/DC converter which is component of AVR(Automatic Voltage Regulator) system for excitation current control is connected to diode rectifier and DC/DC converter system. In the case of diode rectifier system of phase controlled converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, two stage three phase PWM AC/DC converter is studied to solve these problems. The characteristics of a proposed converter reduces the harmonics and reactive power of the distribution line and has fast dynamic response in transient period using boost converter and current control mode buck converts. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

Interconnection Capacity Evaluation of Distributed Resources at the Distribution Networks in View of Distribution Protection Coordination (배전계통의 보호협조측면에서 본 분산전원 연계용량 검토)

  • Choi, Joon-Ho;Ro, Kyoung-Soo;Park, Sung-Jun;Song, Kyung-Bin;Yun, Sang-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.107-116
    • /
    • 2007
  • The introduction of new renewable energy is going on increase with the second plan of the Korean Government "Technology Development, Utilization and Popularization of New Renewable Energy". In general, it is connected to the power system due to the nature of it's source characteristics but it's interconnection operation impacts on the power system planning and operation. The operation schemes of the existing power distribution system are based on the unidirectional power flow, but unidirectional power flow changes to bidirectional power flow due to the interconnection operation of new renewable energy. It degrade the existing protection coordination system and power quality of the power distribution system. Thus, the technical evaluation process of the interconnection of new renewable energy are necessary. In this paper, the characteristics of the existing automatic recloser and sectionalizer are reviewed and interconnection capacity evaluation method of the DR(distributed resources) in the existing automatic recloser-sectionalizer protective coordination system are proposed.

D.C. Motor Speed Control by Learning Gain Regulator (학습이득 조절기에 의한 직류 모터 속도제어)

  • Park, Wal-Seo;Lee, Sung-Su;Kim, Yong-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.82-86
    • /
    • 2005
  • PID controller is widely used as automatic equipment for industry. However when a system has various characters of intermittence or continuance, a new parameter decision for accurate control is a bud task. As a method of solving this problem, in this paper, a teaming gain regulator as PID controller functions is presented. A propriety teaming gain of system is decided by a rule of Delta learning. The function of proposed loaming gain regulator is verified by simulation results of DC motor.

The Study of characteristic comparison with inrush and fault current occurred in distribution system (배전계통에서 발생하는 돌입전류와 고장전류의 특성 비교연구)

  • 오용택;김진성
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.51-58
    • /
    • 2001
  • This paper gives a type and high-frequency waves analysis of in-rush current cab be flowed into distribution automatic machine to be installed in distribution line in order to use minimizing operation error of failure indicator to have been issue recent with obtaining high-frequency component that can be different from current. The in-rush and fault current data studied in this paper is to be surveyed actually in USA distribution system substation line of Bryan Power Company near Texas A. M University, to be occurred high impedance fault.

  • PDF

A Study of Vehicle's Monitoring and Controller Using Imbedded Web Server (임베디드 웹 서버를 이용한 자동차용 모니터링 및 제어기 개발에 관한 연구)

  • Lee, Suk-Won;Yang, Seung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.107-113
    • /
    • 2005
  • In this paper, Web server is built up using PXA255, 32bit RISC processor with porting Embedded Linux and GoAhead HTTP(Hyper Text Transfer Protocol) web server, and the system which can monitor and control the environment and condition for AICC(Automatic Intelligent Cruise Control) is realized For sensing the operation condition and change of vehicle the desired data is derived by interfacing ECU(Electric Control Unit) and Embedded system and the rpm of engine is controlled by step motor connected to throttle valve.

The Development of Automatic Voltage Regulation Using DSP for the Small and Middle Generator (DSP를 사용한 중소형 발전기 자동전압 조정기 개발)

  • 임익헌;류호선;이주현;이재도;송성일
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.305-309
    • /
    • 2003
  • In recent large power plants, the excitation system has the static type, which is characterized by the fast response to increase the transient stability. The high capacity excitation systems developed in KEPRI is either a hot back-up, hybrid hot back-up (analog + digital) or triple modular redundant digital type, both well proven by actual tests and applied in commercial operation. The large excitation systems have been developed taking into consideration the parameters of large scale power plants, resulting in high costs and subsequently are supplied at higher prices. When used at small sized power plants, the cost impact is relatively high. As a countermeasure to such a situation, KEPRI has recently developed a reliable, miniature digital excitation system, which is one-board type, convenient and adequate for low-price, small-sized (0.5MW∼200MW) power plants.

  • PDF