• 제목/요약/키워드: Automated Blind

검색결과 18건 처리시간 0.02초

재실자 방해 최소화를 위한 자동 블라인드 제어 방안 (Automated Blind Control Strategy to Minimize Occupant's Distractions)

  • 구소영;여명석;성윤복;김광우
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.84-92
    • /
    • 2013
  • Blinds are a common type of shading device and are increasingly operated automatically to overcome the limitations of manual operation. Automated blinds need to be controlled to maximize benefits of daylight in the point of occupant comfort and energy consumption. However, the previous control methods could cause occupant's distractions by the undesirable control time interval and amount of blind movement. A few researches suggested the control concept for minimizing occupant's distractions by automatic blind control, but they did not provide optimal control algorithm to be useful in practice. In this paper, we propose an optimal control algorithm for automated blinds that can maximize not only visual comfort but also sunlight penetration into buildings based on occupants' preferences on blind movement and sunlight. The proposed control algorithm can prevent solar glare on workplane and minimize occupant's distractions to maximize occupants' visual comfort.

재실자의 시쾌적과 건물에너지성능을 고려한 슬랫형 블라인드 자동제어전략 (Optimum Automated Control Strategies of Inside Slat-type Blind considering Visual Comport and Building Energy Performance)

  • 오명환;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.187-195
    • /
    • 2011
  • Glass Envelope is vulnerable to insulation performance and controling solar radiation. Insulation performance is consistently improving these days due to recent building energy saving policy in South Korea. However, solar control at glass envelope is still limited to meeting requirements of ideal high performance. Generally, Inside Blind plays an important role of solar control instead of glass which have a characteristics of transmitted solar. Unfortunately, most of them are controled by occupants and which method is not resonable in building energy. Therefore, achieving the high efficient performance building, automated control blind system considering reduction of building loads have to be adopted. Furthermore, considering occupants visual comport about removing discomfort glare is also essential.

  • PDF

혼합형 채광조절장치가 실내공간의 주광조도분포에 미치는 영향에 관한 Mockup 실험평가 (Light Factor Performance of a Room with Light Guide and Blind Systems by Mockup Experiments)

  • 신화영;김정태
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.23-31
    • /
    • 2007
  • This study aims to evaluate the illuminance performance of sloped light guide with automated venetian blind systems. For the purpose, a mock-up model was constructed as a prototype of Korean office building with $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and south facing side-window mounted between the clerestory window($2.0m^2$) and the view window($5.6m^2$). The light guide of 1.28m deepth and $29^{\circ}$ tilted angle, is covered with 0.6mm galvanized steel sheet and 97% reflective film. To protect the room from low solar angle, a blind systems, 0.15m deepth and $30^{\circ}$ automated slat angle was installed. To assess illuminance performance, the totally 37 measuring points for illuminance were monitored. For the detailed analysis, photometric sensors were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point) respectively. The performance was measured under clear sky and is monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons of light factor and uniformity are discussed.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

소규모 사무실공간에서 주광조건에 따른 대비효과 및 조명에너지 절약예측 (Prediction of Contrast and Lighting Energy Saivings in a Small Office Space according to Daylight Conditions)

  • 김수영
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.35-43
    • /
    • 2004
  • Illuminance and luminous levels in a small office space due to daylight were calculated to analyze the impact of daylight on contrast and lighting energy savings. Computer simulations were performed for four blind conditions under a clear sky condition. The blind conditions significantly impacted the illuminance an4 luminance level. Visual performance scores were calculated according to the transfer function that uses absolute contrast between target and background surface. The blind condition that had 45 tilted angle toward ground provided good contrast and performance scores. Using a control algorithm of an automated daylight dimming control system lighting energy sayings were predicted. For all blind conditions minimum lighting energy was consumed.

혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가 (Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments)

  • 신화영;안현태;김정태
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

창면적비 및 향변화에 따른 슬랫형 블라인드의 최적각도 제어 알고리즘 산출 및 비교분석 (Development and comparative analysis of slat angle control algorithm of venetian blind according to window-to-wall ratio and zone orientation)

  • 권혁주;이금호;이광호
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: Most contemporary office buildings supply external views, a sense of openness and a sense of time to their occupants by adopting the curtain walls, which are equipped with an outer cover having large window area. As a result, the amount of radiation increases, adversely affecting cooling load during the summer in office buildings. Although solar radiation decreases heating load and reduces energy costs during the winter period, due to the characteristics of offices where occupants work largely during daytime, the cooling load is important compared to the heating. Therefore, diverse measures to resolve those trade-offs and annual energy cost have been investigated. Method: In this study, the annual thermal load was comparatively analyzed according to the slat angle of the venetian blind along with lighting control technique. Result: After selecting effective conditions, in order to resolve such issues, this study established automated control strategies of slat angle depending on the window-to-wall ratio and zone orientation, so that the findings of this study can be effectively generalized to other circumstances.

블라인드 리벳 너트 체결 적합성에 관한 연구 (Accurate Fastening of Blind Rivet Nuts: A Study)

  • 김찬양;구본준;이사랑;최정묵;홍석무
    • 소성∙가공
    • /
    • 제29권6호
    • /
    • pp.331-337
    • /
    • 2020
  • Blind rivet nuts (BRNs) are increasingly used in automotive industry because unlike conventional bolt fastening, BRN fastening requires access from one side only. Generally, fastening is conducted using automated units, but manual fastening may be resorted to in case of small quantities. Since the fastening direction is not exactly perpendicular to the sheet metal, the BRN axis is tilted with respect to the plate and may result in damage or incomplete fastening. As the tilt angle (clamping angle α) increases, undesired plate deformation occurs and the contact area of the plate with the BRN fastening area decreases, reducing the clamping effect. In this study, the reduction of the clamping effect with the α was investigated to ensure stable fastening force. M6 BRNs were used in the tests. The fastening force was measured as follows: the plate was cut in half through the center of the hole; the BRN was inserted into the hole and fastened; and the clamping angle a was measured (values, 0° ≤ α ≤ 9°). The force leading to the separation of the halves was measured using a universal testing machine (UTM). The maximum α range, in which the fastening force remains stable, was determined. Finite element (FE) analysis confirmed that the fastening force decreases approximately linearly with increasing α. Based on the experiment and FE analysis using various α, the fastening force was found to decrease with α. Further, the maximum tolerance for α that provides secure fastening without damage is suggested.

복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가 (Evaluation on the Characteristics of Daylight Distributions of Grating Louver System in a Pair Glass by Computer Simulation)

  • 박병철;최안섭
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.1-9
    • /
    • 2009
  • 최근 실내에 유입된 주광을 활용하여 인공조명의 에너지를 절감하는 광센서 조광제어시스템에 관한 연구는 유용한 주광의 유입을 위한 자동 차양장치와의 통합을 중심으로 이루어지고 있다. 기존의 연구는 자동 롤러쉐이딩시스템과 베니션블라이드에 관한 연구로, 이 두 시스템은 주광의 입사를 수직적으로 계산한 일영각을 기준으로 차양장치의 높이 및 각도를 계산하여 제어하고 있다. 본 연구는 광센서 조광제어시스템과 연동을 위한 새로운 차양장치로 주광의 유입을 수직 수평으로 제어하는 복층유리 격자루버시스템을 제안하고, 창면의 위치에 따른 루버의 간격을 산출하였으며, 컴퓨터 시뮬레이션을 통하여 격자루버시스템의 주광유입특성을 분석하고 평가하였다.

Fermented Laminaria japonica improves working memory and antioxidant defense mechanism in healthy adults: a randomized, double-blind, and placebo-controlled clinical study

  • Kim, Young-Sang;Reid, Storm N.S.;Ryu, Jeh-Kwang;Lee, Bae-Jin;Jeon, Byeong Hwan
    • Fisheries and Aquatic Sciences
    • /
    • 제25권8호
    • /
    • pp.450-461
    • /
    • 2022
  • A randomized, double-blind, and placebo-controlled clinical study was used to determine the cognitive functions related to working memory (WM) and antioxidant properties of fermented Laminaria japonica (FLJ) on healthy volunteers. Eighty participants were divided into a placebo group (n = 40) and FLJ group (n = 40) that received FLJ (1.5 g/day) for 6 weeks. Memory-related blood indices (brain-derived neurotrophic factor, BDNF; angiotensin-converting enzyme; human growth hormone, HGH; insulin-like growth factor-1, IGF-1) and antioxidant function-related indices (catalase, CAT; malondialdehyde, MDA; 8-oxo-2'-deoxyguanosine, 8-oxo-dG; thiobarbituric acid reactive substances, TBARS) were determined before and after the trial. In addition, standardized cognitive tests were conducted using the Cambridge Neuropsychological Test Automated Batteries. Furthermore, the Korean Wechsler Adult Intelligence Scale (K-WAIS)-IV, and the Korean version of the Montreal Cognitive Assessment (MoCA-K) were used to assess the pre and post intake changes on WM-related properties. According to the results, FLJ significantly increased the level of CAT, BDNF, HGH, and IGF-1. FLJ reduced the level of TBARS, MDA, and 8-oxo-dG in serum. Furthermore, FLJ improved physical activities related to cognitive functions such as K-WAIS-IV, MoCA-K, Paired Associates Learning, and Spatial Working Memory compared to the placebo group. Our results suggest that FLJ is a potential candidate to develop functional materials reflecting its capability to induce antioxidant mechanisms together with WM-related indices.