• 제목/요약/키워드: Attenuation of Noise

검색결과 477건 처리시간 0.027초

음향인텐시티법을 이용한 공조 덕트소음기의 감음성능평가방법에 관한 연구 (The Estimation of Sound Attenuation Caused by Duct Silencer Using Sound Intensity Method)

  • 김석홍;손장열;오재응;김여식
    • 한국음향학회지
    • /
    • 제6권2호
    • /
    • pp.54-61
    • /
    • 1987
  • 실험실이 아닌 일반음장에서 음향인텐시티법을 이용하여 공조덕트 소기기의 감음성능 평가방법을 검토하였다. 음향인델시티법에 의한 감음량 측정치는 음압법에 의한 측정치보다 이논치와 비교적 잘 일치하였으며, 음향인텐시티법은 음압법에 비하여 음장조건에 따른 영향을 비교적 적게 받는 것으로 나타났다.

  • PDF

전파 흡수체에 의한 구형 공동 공진기의 방사노이즈 억제 방법에 관한 연구 (A Study on the Method to Suppress Radiation-Noise with Electromagnetic Wave Absorber in the Rectangular Cavity Resonator)

  • 김경용;김왕섭
    • 전자공학회논문지A
    • /
    • 제28A권12호
    • /
    • pp.19-23
    • /
    • 1991
  • A method for suppressing unwanted resonance modes by attaching an electromagnetic wave absorber onto a metal case was studied to prevent performance deterioration of electronic devices. The electromagnetic wave absorber fabricated for this study had an attenuation characteristics above 20dB in the frequency band from 450MHz, 1150MHz. A rectangular cavity resonator whose resonance frequencies of TE$_{101}$, TE$_{102}$ modes were 900MHz, 1250MHz, respectively, was made to measure attenuation for the electromagnetic wave absorber-metal assembly. The result showed that the resonance mode for high attenuation was sensitive to the location of electromagnetic wave absorber, and the attenuation characteristics above 20dB could be obtained when electromagnetic wave absorber was properly positioned.

  • PDF

지하매설 유체함입 강파이프의 감쇠특성 규명 (Attenuation Characteristics of the Buried Steel Water Pipes)

  • 박경조;강우석;김이곤
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.39-45
    • /
    • 2009
  • The attenuation of the fundamental non-torsional modes that propagate down buried steel water pipes has been studied. The mode shapes, mode attenuation due to leakage into the surrounding medium and the scattering of the modes as they interact with pipe joints and fittings have been investigated. In the low frequency region the mode predicted to dominate over significant propagation distances approximates a plane wave in the water within pipe. The established acoustic technique used to locate leaks in buried steel water pipes assumes that leak noise propagates as a single non-dispersive mode at a velocity related to the low frequency asymptote of this water borne mode.

  • PDF

Analysis of Fiber-optic Link Budget for Optically fed Wireless Communication

  • Kim, Jung-Tae
    • Journal of information and communication convergence engineering
    • /
    • 제1권1호
    • /
    • pp.35-38
    • /
    • 2003
  • Analyses of performance of wireless broadband communication systems employing fiber-optic link have presented. We have analyzed CNR penalty to evaluate system performance by taking into account, radio link considering rainfall attenuation, and optical link considering several carrier-to-noise ratio versus the optical modulation index.

방음실에 의한 공장설비 소음의 감쇠 효과에 관한 연구 (A Study on Sound Attenuation of Plant Noise by Enclosure)

  • 윤세철;이해경
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.119-124
    • /
    • 1994
  • The considerations in the noise control by enclosure are the rise of temperature and sound pressure, transmission loss, absorption coefficient of the materials, the structure of the soundproof panels, an opening and coincidence frequency. But it is very difficult that we obtain the accurate data about those in design, so, the noise reduction after enclosing does not correspond with the calculation. The difference of the noise reduction between the calculation and the measurement was 8.2dBA, and we can obtain the approximate result as the following formula which correct 10dBA, safely.

  • PDF

전력용 변압기 차음실 개발 (Development of the Soundproof Enclosure for Power Transformers)

  • 권동진;구교선;이욱륜
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.107-114
    • /
    • 2009
  • 전력수요의 증가 및 도심지역의 확대로 도심지내 변전소에 전력용 변압기의 설치가 필요하나, 변전소의 전력용 변압기에서 발생하는 소음으로 인한 민원이 증가하고 있다. 따라서 전력용 변압기에서 발생하는 소음의 전파를 차단하기 위하여, 옥외 변전소의 전력용 변압기에는 방음벽을 적용하여 왔으며, 옥내 변전소에는 방음문, 방음 셔터 및 풍도형 방음장치 등을 적용하여 왔다. 그러나 이러한 방법에 의한 소음저감 효과는 만족할 정도에 이르지 못하는 실정이다. 본 연구에서는 전력용 변압기로부터 발생되는 소음을 효과적으로 차단하기 위해 변압기 차음실을 개발하였다. 개발한 변압기 차음실은 154[kV] 변압기에 적용하여 120[Hz] 성분에서 15[dB]의 소음저감 효과를 확인하였다.

개인휴대통신에서 이동국의 수신성능개선을 위한 시스템 분석 (System Analysis for Receiving Performance Improvement of Mobile Station in PCS)

  • 주재한;박세승;박종안;천종훈
    • 한국정보처리학회논문지
    • /
    • 제6권1호
    • /
    • pp.159-166
    • /
    • 1999
  • 본 논문에서는 개인휴대통신(PCS)의 최소 규격인 J-STD-018을 기준으로 하여 수신기의 수신감도, 단일톤 둔감도, 상호변조 스퓨리어스에 의한 응답감쇄 규격에서 각각 잡음지수와 제 3고조파 차담점을 구하고 시뮬레이션을 통하여 분석하였다. 시뮬레이션 결과 수신감도 규격에서는 전체 잡음지수가 5.99dB이고 제 3고조파 차단점은 -33.979dBm이었다. 또한 단일톤 둔감도 및 상호 변조 스퓨리어스에 의한 응답감쇄 규격에는 전제 잡음지수가 0.367dBm이고 제 3고조파 차단점은 6.989 이 증가되었다. 이것은 잡음지수보다 제 3고조파 차단점이 훨씬 증가 되므로 간섭톤과 밀접한 관계가 있는 소자인 Mixer는 제 3고조파 차단점을 높게 규정하고 IF SAW 필터의 중심 주파수로부터 1.25MHz와 2.05MHz지점인 곳에 감쇄가 456dB이상 되어야 함을 보였다.

  • PDF