• 제목/요약/키워드: Attenuation coefficient

검색결과 418건 처리시간 0.03초

A STUDY ON THE DIFFUSE ATTENUATION COEFFICIENT OF DOWN-WELLING IRRADIANCE AROUND THE YELLOW SEA

  • Min, Jee-Eun;Ahn, Yu-Hwan;Ryu, Joo-Hyung;Lee, Kyu-Sung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.459-462
    • /
    • 2006
  • The diffuse attenuation coefficient for down-welling irradiance ($K_d$) is an important parameter for ocean studies including remote sensing applications. For the vast ocean, ocean color remote sensing is the only possible means to get the fine-scale measurements of $K_d$. To develop a technique of estimating $K_d$ from remotely sensed data, the following underwater optical parameters (absorption coefficient (a), attenuation coefficient (c), scattering coefficient (b), diffuse attenuation coefficient ($K_d$), etc.) have been studied. For this research we conducted the field campaign around the Yellow Sea at $8{\sim}9$ June, 2006. We obtained a set of underwater optical parameter data: down-welling irradiance ($E_d$), up-welling irradiance ($E_u$) and up-welling radiance ($L_u$) using TriOS optical sensors and a, c coefficient using Spectral Absorption and Attenuation Meter (AC-S). We then derived $K_d$ values from $E_d$ for each depth.

  • PDF

초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficient)

  • 정남용;박성일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.340-345
    • /
    • 2003
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the relation between crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the results of experiments, the measurement method of crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficient)

  • 정남용;박성일
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.386-393
    • /
    • 2004
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.

DETECTION OF INTERFACIAL CRACK LENGTH BY USING ULTRASONIC ATTENUATION COEFFICIENTS ON ADHESIVELY BONDED JOINTS

  • Chung, N.Y.;Park, S.I.
    • International Journal of Automotive Technology
    • /
    • 제5권4호
    • /
    • pp.303-309
    • /
    • 2004
  • In this paper, an interfacial crack length has been detected by using the ultrasonic attenuation coefficient on the adhesively bonded double-cantilever beam (DCB) joints. The correlations between energy release rates which were investigated by experimental measurement, the boundary element method (BEM) and Ripling's equation are compared with each other. The experimental results show that the interfacial crack length for the ultrasonic attenuation coefficient and energy release rate increases proportionally. From the experimental results, we propose a method to detect the interfacial crack length by using the ultrasonic attenuation coefficient and discuss it.

조직 정량화를 위한 의용 초음파 영상 기술 개발(감쇠계수 측정에서 회질 영향의 보정법) (Development of Medical Ultrasound Imaging Techniques for Tissue Characterization (The Correction Method of Diffraction Effect in Measurements of Attenuation Coefficient))

  • 한성현;이강호;최종호;최종수
    • 대한전자공학회논문지
    • /
    • 제27권12호
    • /
    • pp.1925-1932
    • /
    • 1990
  • In this paper, we consider the effect of diffraction due to the finite-sized aperture and propose the new correction method of errors in measurements of attenuation coefficient owing to the diffraction effect. In the existing correction method, we obtained the attenuation coefficient after correct the spectrum at each depth. However, this paper obtain the attenuation coefficient using lg-spectral difference approach and then correct errors. As a proposed method is not correction for the spectrum at each depth but the difference spectrum, we reduce the calculation. Also the correction is performed through the total frequency range, the accurate attenuation coefficient in whole bandwidth is produced.

  • PDF

Al/Epoxy 이종재 접합 계면의 초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficients on Interfaces of Al/Epoxy Bonded Dissimilar Materials)

  • 박성일;정남용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1109-1114
    • /
    • 2003
  • The initial crack often occurs on the bonded interface and it is the general cause of the interface fracture. It is very significant to establish the measurement method of interfacial crack by applying the ultrasonic technology into the interface of bonded dissimilar materials. In this paper, the interfacial crack length was measured by ultrasonic attenuation coefficient in the Al/Epoxy bonded dissimilar materials of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental and Ripling's equation measurement of compliance. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the experimental results, a measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

간 병변의 정량화를 위한 초음파 영상 신호의 감쇄상수 추정 (Estimation of Attenuation Coefficient based on Ultrasonic Image for quantification of the Liver Diseases)

  • 우광방;신동호;이성모;신영민;이노성;오성권
    • 대한전자공학회논문지
    • /
    • 제25권1호
    • /
    • pp.49-55
    • /
    • 1988
  • To provide a quantitative parameter of evaluating diagnosis of the liver diseases accurately, the ultrasonic attenuation coefficient was estimated from liver phantoms, 15 normal human livers and 30 liver disease patients. Two kind of phantoms(No.1: 1552m/s, No.2: 1562m/s) which have velocity (1560m/s) similar to that in human liver were constructed and their ultrasonic attenuation coefficients were determined. In this paper the spectral-shift approach and spectral-difference approach were used for estimating ultrasonic attenuation coefficient, \ulcornerdB/Cm.MHz). These two approaches were utilized to esitmate for 15 normal humans without any liver disease and 30 liver disease patients. The results indicate that the two types of phantoms produce the value of near the suggested value of 0.5 and the attenuation coefficients of hepatoma, normal liver, corrhosis, fatty liver and hepatitis show decreasing value in order named, suggesting that the present study can be of clinical value incorrelating the estimated attenuation coefficidents with the liver diseases.

  • PDF

광자극형광나노닷선량계를 사용한 X선 빔의 유효에너지 결정 (Determination of the Effective Energy of X-Ray Beam Using Optically Stimulated Luminescent nanoDot Dosimeters)

  • 김종언;이상훈
    • 한국방사선학회논문지
    • /
    • 제9권6호
    • /
    • pp.375-379
    • /
    • 2015
  • 이 연구의 목적은 다종에너지 X선 빔의 유효에너지를 결정하는데 있다. 80 kVp X선 빔에 대한 알루미늄의 반가층은 광자극형광나노닷선량계들(OSLnDs)을 사용하여 측정하였다. 선감쇠계수(${\mu}$)는 측정된 반가층을 사용하여 계산하였다. 그리고 질량감쇠계수(${\mu}/{\rho}$)는 알루미늄의 밀도로 선감쇠계수를 나누어 얻었다. 얻어진 질량감쇠계수의 유효에너지($E_{eff}$)는 미국표준기술연구소(NIST)에서 주어진 알루미늄의 광자에너지들에 대한 X선질량감쇠계수들의 자료를 사용하여 결정하였다. 결과로서, 반가층, 선감쇠계수 및 질량감쇠계수는 각각 2.262 mmAl, $3.06cm^{-1}$, $1.114cm^2/g$이다. 그리고 유효에너지는 29.79 keV에서 결정되었다.

유도초음파의 감쇠계수에 대한 실험적 고찰 (Experimental Investigation for the Attenuation Coefficient of Ultrasonic Guided Wave)

  • 이동진;조윤호;이준현;신동철
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.458-465
    • /
    • 2009
  • 일반적인 산업현장에서 내부결함 평가를 위해 사용되어온 유도초음파기법은 비결함 지역에서는 에너지 감쇠를 고려하지 않고 적용되어 왔다. 결함 지역에서의 신호는 산란과 반사에 의해서 분명한 감쇠가 발생하지만 비결함 지역에서도 작은 감쇠가 발생한다. 또한 분산선도에서 판파(Lamb wave)는 각 두께, 주파수에 의해 분산성이 달라지기에 각 모드에 적합한 감쇠계수를 찾는 것은 중요하다. 이를 위해 접촉식 PZT(piezoelectric)센서를 이용한 pitch-catch 방식으로 거리에 따른 각 모드의 감쇠계수를 구하였다. 본 연구에서는 흔히 쓰이는 알루미늄과 구리판으로, 두께 차이, 모드 차이, 재질 차이에 의한 실험적인 감쇠율을 구하는데 중점을 두었다. 그 결과 각 변수에 따라 감쇠계수는 달라지며, 정량화가 필요하다는 것을 확인하였다.

Ultrasonic Phase Velocity and Attenuation Coefficient Predicted by Biot's Theory and the MBA Model in Cancellous Bone

  • Lee Kang Il;Yoon Suk Wang
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.183-186
    • /
    • 2004
  • Biot's theory and a modified Biot-Attenborough (MBA) model are applied to predict the dependences of acoustic characteristics on frequency and porosity in cancellous bone. The phase velocity and the attenuation coefficient predicted by both theories are compared with previous in vitro experimental measurements in terms of the mixed, the fast, and the slow waves. Biot's theory successfully predicts the dependences of phase velocity on frequency and porosity in cancellous bone, whereas a significant discrepancy is observed between predicted and measured attenuation coefficients. The MBA model is consistent with reported measurements for both dependences of phase velocity and attenuation coefficient on frequency and porosity. Based on the theoretical predictions from the MBA model, it is suggested that the attenuation coefficient of the mixed wave is dominated by the fast wave in the low-porosity region while it is dominated by the slow wave in the high-porosity region. This provides a qualitative explanation for the nonlinear relationship of attenuation of the mixed wave with porosity in cancellous bone.

  • PDF