Design of CMOS Multifunction ICs for X-band Phased Array Systems (CMOS 공정 기반의 X-대역 위상 배열 시스템용 다기능 집적 회로 설계)

  • Ku, Bon-Hyun;Hong, Song-Cheol
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.12
    • /
    • pp.6-13
    • /
    • 2009
  • For X-band phased array systems, a power amplifier, a 6-bit phase shifter, a 6-bit digital attenuator, and a SPDT transmit/receive (T/R) switch are fabricated and measured. All circuits are demonstrated by using CMOS 0.18 um technology. The power amplifier has 2-stage differential and cascade structures. It provides 1-dB gain-compressed output power ($P_{1dB}$) of 20 dBm and power-added-efficiency (PAE) of 19 % at 8-11 GHz frequencies. The 6-bit phase shifter utilizes embedded switched filter structure which consists of nMOS transistors as a switch and meandered microstrip lines for desired inductances. It has $360^{\circ}$ phase-control range and $5.6^{\circ}$ phase resolution. At 8-11 GHz frequencies, it has RMS phase and amplitude errors are below $5^{\circ}$ and 0.8 dB, and insertion loss of $-15.7\;{\pm}\;1,1\;dB$. The 6-bit digital attenuator is comprised of embedded switched Pi-and T-type attenuators resistive networks and nMOS switches and employes compensation circuits for low insertion phase variation. It has max. attenuation of 31.5 dB and 0.5 dB amplitude resolution. Its RMS amplitude and phase errors are below 0.4 dB and $2^{\circ}$ at 8-11 GHz frequencies, and insertion loss is $-10.5\;{\pm}\;0.8\;dB$. The SPDT T/R switch has series and shunt transistor pairs on transmit and receive path, and only one inductance to reduce chip area. It shows insertion loss of -1.5 dB, return loss below -15 dB, and isolation about -30 dB. The fabricated chip areas are $1.28\;mm^2$, $1.9mm^2$, $0.34\;mm^2$, $0.02mm^2$, respectively.

Comparative Analysis of the Q Value between the Crust of the Seoul Metropolitan Area and the Eastern Kyeongsang Basin (수도권과 경상 분지 동부 지역 지각의 Q 값 비교 분석)

  • Park, Yoon-Jung;Kyung, Jai-Bok;Do, Ji-Young
    • Journal of the Korean earth science society
    • /
    • v.28 no.6
    • /
    • pp.720-732
    • /
    • 2007
  • For the Seoul metropolitan area and the eastern Kyeongsang Basin, we simultaneously calculated $Q_P^{-1}$ and $Q_S^{-1}$ by applying the extended coda-normalization method for 98 seismograms of local Earthquakes. As frequency increases from 1.5 Hz to 24 Hz, the result decreased from $(4.0{\pm}9.2){\times}10^{-3}$ to $(4.1{\pm}4.2){\times}10^{-4}$ for $Q_P^{-1}$ and $(5.5{\pm}5.6){\times}10^{-3}$ to $(3.4{\pm}1.3){\times}10^{-4}$ for $Q_S^{-1}$ in Seoul Metropolitan Area. The result of eastern Kyeongsang basin also decreased from $(5.4{\pm}8.8){\times}10^{-3}$ to $(3.7{\pm}3.4){\times}10^{-4}$ for $Q_P^{-1}$ and $(5.7{\pm}4.2){\times}10^{-3}$ to $(3.5{\pm}1.6){\times}10^{-4}$ for $Q_S^{-1}$. If we fit a frequency-dependent power law to the data, the best fits of $Q_P^{-1}$ and $Q_S^{-1}$ are $0.005f^{-0.89}$ and $0.004f^{-0.88}$ in Seoul metropolitan Area, respectively. The value of $Q_P^{-1}$ and $Q_S^{-1}$ in the eastern Kyeongsang basin are $0.007f^{-1.02}$ and $0.006f^{-0.99}$, respectively. The $Q_S^{-1}$ value of the eastern Kyeongsang basin is almost similar to Seoul metropolitan area. But the $Q_P^{-1}$ value of the eastern Kyeongsang basin is a little higher than that of Seoul metropolitan area. This may be that the crustal characteristics of the eastern Kyeongsang basin is seismologically more heterogeneous. However, these $Q_P^{-1}$ values in Korea belong to the range of seismically stable regions all over the world.

Anti-diabetic effects of aqueous and ethanol extract of Dendropanax morbifera Leveille in streptozotocin-induced diabetes model (Streptozotocin에 의해 유도된 당뇨모델동물에서 황칠나무 (Dendropanax morbifera Leveille)의 열수추출물과 에탄올추출물의 당뇨 질환 개선 효능)

  • An, Na Young;Kim, Ji-Eun;Hwang, DaeYoun;Ryu, Ho Kyung
    • Journal of Nutrition and Health
    • /
    • v.47 no.6
    • /
    • pp.394-402
    • /
    • 2014
  • Purpose: Dendropanax morifera Leveille (DML) exhibits diverse biological and pharmacological activities, including anti-oxidative effect, anti-cancer activity, hepatoprotection, immunological stimulation, and bone regeneration. As part of the identification for novel functions of DML, we investigated the therapeutic effects of DML on diabetes induced by streptozotocine (STZ) treatment. Methods: First, the four extracts including the water extract of leaf (DLW), the ethanol extract of leaf (DLE), the water extract of stem (DSW), and the ethanol extract of stem (DSE) were collected from the leaf and stem of DML using a hot water and ethanol solvent. Alterations in body weight, glucose concentration, insulin level, and pancreatic islet structure were investigated in diabetic mice after treatment with extracts of DML for 2 weeks. Results: Among four extracts, the highest level of total polyphenols and total flavonoids was detected in DLW, while the lowest level of these was measured in DSE. The radical scavenging activity was also higher in DLW than in the other three extracts at the concentration of $25-100{\mu}g/mL$, although this activity was maintained at a constant level in all groups at the concentration of $500{\mu}g/mL$. Based on the results of anti-oxidant activity, DLW and DLE were selected for examination of anti-diabetic effects in a diabetes model. Body weight was gradually decreased in all STZ treated groups compared with the No treated group. However, four STZ/DML treated groups maintained a high level of body weight during 7-14 days, while the STZ/vehicle treated group showed a gradual decrease of body weight during the same period. Also, a significant decrease or increase in the concentration of glucose and insulin in the blood of the diabetes model was detected in a subset of groups, although the highest increase was detected in the STZ/DLE-200 treated group. In addition, the histological structure of pancreatic islet was significantly recovered after treatment with DLW and DLE. Conclusion: These results suggest that DLW and DLE may contribute to attenuation of clinical symptoms of diabetes as well as prevent the destruction of pancreatic ${\beta}$-cells in STZ-induced diabetes mice.

Development of Lead Free Shielding Material for Diagnostic Radiation Beams (의료영상용 방사선방호를 위한 무납차폐체 개발)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • The shielding materials designed for replacement of lead equivalent materials for lighter apron than that of lead in diagnostic photon beams. The absorption characteristics of elements were applied to investigate the lead free material for design the shielding materials through the 50 kVp to 110 kVp x-ray energy in interval of 20 kVp respectively. The idea focused to the effect of K-edge absorption of variable elements excluding the lead material for weight reduction. The designed shielding materials composited of Tin 34.1%, Antimon 33.8% and Iodine 26.8% and Polyisoprene 5.3% gram weight account for 84 percent of weight of lead equivalent of 0.5 mm thickness. The size of lead-free shielder was $200{\times}200{\times}1.5\;mm^3$ and $3.2\;g/cm^3$ of density which is equivalent to 0.42 mm of Pb. The lead equivalent of 0.5 mm thickness generally used for shielding apron of diagnostic X rays which is transmitted 0.1% for 50 kVp, 0.9% for 70 kVp and 3.2% for 90 kVp and 4.8% for 110 kVp in experimental measurements. The experiment of transmittance for lead-free shielder has showed 0.3% for 50 kVp, 0.6% for 70 kVp, 2.0% for 90 kVp and 4.2% for 110 kVp within ${\pm}0.1%$. respectively. Using the attenuation coefficient of experiments for 0.5 mm Pb equivalent of lead-free materials showed 0.1%. 0.3%, 1.0% and 2.4%, respectively. Furthermore, the transmittance of lead-free shielder for scatter rays has showed the 2.4% in operation energy of 50 kVp and 5.9% in energy of 110 kVp against 2.4% and 5.1% for standard lead thickness within ${\pm}0.2%$ discrepancy, respectively. In this experiment shows the designed lead-free shielder is very effective for reduction the apron weight in diagnostic radiation fields.

Deterioration Diagnosis and Source Area of Rock Properties at the West Stone Pagoda, Gameunsaji Temple Site, Korea (감은사지 서탑의 풍화훼손도 진단 및 석재의 산지추정)

  • Lee Chan Hee;Lee Myeong Seong;Suh Mancheol;Choi Seok-Won;Kim Man Gap
    • Economic and Environmental Geology
    • /
    • v.37 no.5
    • /
    • pp.569-583
    • /
    • 2004
  • The rock properties of the West pagoda in the Gameunsaji temple site are composed mainly of dark grey porphyritic granodiorite with medium grained equigranular texture and developed with small numerous dioritic xenoliths. These xenoliths occurred with small holes due to different weathering processes. As a weathering results, the rock properties of this pagoda occur wholly softened to physical hardness because of a complex result of petrological, meteorological and biological causes. Southeastern part of the pagoda deteriorated seriously that the surface of rock blocks showed partially exfoliations, fractures, open cavities in course of granular decomposition of minerals, sea water spray and crystallization of salt from the eastern coast. The Joint between blocks has small or large fracture cross each other, contaminated and corrupted for inserting with concrete, cement mortar, rock fragments and iron plates, and partially accelerated coloration and fractures. There are serious contamination materials of algae, fungus, lichen and bryophytes on the margin and the surface on the roof stone of the pagoda, so it'll require conservation treatment biochemically for releasing vegetation inhabiting on the surface and the discontinuous plane of the blocks because of adding the weathering activity of stones and growing weeds naturally by soil processing on the fissure zone. Consisting rock for the conservation and restoration of the pagoda would be careful choice of new rock properties and epoxy to reinforce for the deterioration surfaces. For the attenuation of secondary contamination and surface humidity, the possible conservation treatments are needed.

Pharmacological Action Mechanism(s) of Vasodilator Effect of Calcitonin Gene-related Peptide in Rat Basilar Arteries (흰쥐의 뇌 기저동맥에서 CGRP에 의한 혈관 이완반응의 기전에 대한 연구)

  • Rhim, Byung-Yong;Hong, Sun-Hwa;Kim, Chi-Dae;Lee, Won-Suk;Kim, Dong-Heon;Hong, Ki-Whan
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.1
    • /
    • pp.39-49
    • /
    • 1996
  • In the present study, we observed change in intracellular $Ca^{2+}$$([Ca^{2+}]_i)$ as measured with the fluorescent $Ca^{2+}-indicator$ fura-2 in association with force development of the rat basilar arteries during activation by$K^+$ depolarizing solution and U46619, a thromboxane analogue, in the absence and the presence of calcitonin-gent related peptide (CGRP). CGRP (30 and 100 nM) caused a concentration-dependent inhibition of U46619-induced contraction with decrease in $[Ca^{2+}]_i$, whereas it did not exert any effect on the $K^+$ (90 mM)-induced contraction and increase in $[Ca^{2+}]_i$, Further, $[Ca^{2+}]_i-force$ relationships were determined by plotting the ratio of $F_{340}/F_{380}$ $([Ca^{2+}]_i)$ as a function of the force induced by U46619, and the results were compared with those obtained in the presence of CGRP. The curves obtained in the presence of CGRP (30 and 100 nM) were significantly moved to downward without right shift of the curves suggesting that CGRP inhibited the U46619-induced contraction only by mediation of reduction in $[Ca^{2+}]_i$ with out any change in the sensitivity of contractile apparatus to $Ca^{2+}$. The CGRP-induced attenuation of $[Ca^{2+}]_i$ and force development was significantly inhibited under pretreatment with CGRP $(8{\sim}37)$ fragment (100 nM), a CGRP1 receptor antagonist. Both the reduced contraction and reduction in $[Ca^{2+}]_i$ caused by CGRP were fully reversed by pretreatment with charybdotoxin (100 nM) and iberiotoxin (100 nM), large conductance $Ca^{2+}-activated$ $K^+$ channel blockers, but not by apamin (300 nM), a small conductance $Ca^{2+}-activated$ $K^+$ channel blocker, and glibenclamide ( 1 ${\mu}M$), an ATP-sensitive $K^+$ channel blocker. In conclusion, it is suggested that the CGRP1 receptor, upon activation by CGRP, are coupled to opening of $Ca^{2+}-activated$ $K^+$ channel and cause to decrease in $[Ca^{2+}]_i$, thereby leading to vasodilation of the rat basilar artery. However, it is not defined that the mechanism underlying vasodilation whether the $K^+$ channel blockers, charybdotoxin and iberiotoxin directly block the CGRP receptors and that CGRP-evoked relaxation is dependent on the cyclic AMP or $K^+$ channel opening or both actions.

  • PDF

Regional Distribution of Cerebral Blood Flow in Childhood Measured by $^{99m}Tc-HMPAO$ SPECT : Reference Values of Semiquantitative Indices and Effect of Age ($^{99m}Tc-HMPAO$ SPECT를 이용한 어린이 국소뇌혈류의 정량적 분석 : 정량적 지표들의 참고값 및 연령에 따른 변화)

  • Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Cho, Soo-Churl;Hong, Seung-Bong;Yoon, Byung-Woo;Roh, Jae-Kyu;Myung, Ho-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.6-16
    • /
    • 1991
  • Regional cerebral blood flow (rCBF) was evaluated in 12 children ranging in age from 2.7 to 10.0 yr using $^{99m}Tc-HMPAO$ SPECT. For quantitative analysis, 13 pairs of homologous regions of interest (ROIs) were created on three attenuation-corrected 18.8 mm thick transverse slices matching the cerebral cortical regions, deep gray matter, cerebellar hemisphere, and vascular territories, and the semiquantitative indices including "right to left ratio" [(mean count/voxel of homologous right ROI) / (mean count/voxel of homologous left ROI)] and "regional index"(RI) [(mean count/voxel of a ROI)/ (mean count/voxel of all ROIs of each hemisphere)] were calculated. Mean values of right to left ratios of homologous regions ranged from 0.984 to 1.028 in children under 5 yr (group 1) and from 0.982 to 1.012 in children between 5 and 10 yr (group 2), and the mean $value{\pm}2S.D.$ for each region did not exceed 11% and 12% in group 1 and group 2, respectively. There were no statistically significant differences between the RIs of the homologous right and left regions. Significant differences of RIs were found both between vascular regions (p<0.0005 for goup 1, and p=0.0001 for goup 2) and between regions of cerebral cortices (p<0.0005 for group 1, and p<0.005 for group 2) with a relatively high value in the occipital cortex and the lower values in the cerebellum and deep gray matter among the regions of cerebral cortices in both groups. There were no significant differences between the RIs of corresponding regions of group 1 and group 2, except a significantly higher value of right deep gray matter in group 2 than in group 1(p=0.0301). The RIs of the superior frontal cortex and deep gray matter showed to be positively correlated with age (superior frontal cortex; right: rs=0.5254, p=0.0814, left : rs=0.5919, p=0.0496/deep gray matter; right: rs=0.8246, p=0.0062, left: rs=0.6266, p=0.0377). The results suggest that the rCBF pattern of children approaches that of adults in an accipito-rostral direction. This time course of rCBF changes is in agreement with behavioral, neurophysiological, and anatomical alterations known to occur in the developing brain.

  • PDF

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

Attenuation of Experimental Autoimmune Hepatitis in Mice with Bone Mesenchymal Stem Cell-Derived Exosomes Carrying MicroRNA-223-3p

  • Lu, Feng-Bin;Chen, Da-Zhi;Chen, Lu;Hu, En-De;Wu, Jin-Lu;Li, Hui;Gong, Yue-Wen;Lin, Zhuo;Wang, Xiao-Dong;Li, Ji;Jin, Xiao-Ya;Xu, Lan-Man;Chen, Yong-Ping
    • Molecules and Cells
    • /
    • v.42 no.12
    • /
    • pp.906-918
    • /
    • 2019
  • MicroRNA-223-3p (miR-223-3p) is one of the potential microRNAs that have been shown to alleviate inflammatory responses in pre-clinical investigations and is highly encased in exosomes derived from bone mesenchymal stem cells (MSC-exosomes). MSC-exosomes are able to function as carriers to deliver microRNAs into cells. Autoimmune hepatitis is one of the challenging liver diseases with no effective treatment other than steroid hormones. Here, we examined whether MSC-exosomes can transfer miR-223-3p to treat autoimmune hepatitis in an experimental model. We found that MSC-exosomes were successfully incorporated with miR-223-3p and delivered miR-223-3p into macrophages. Moreover, there was no toxic effect of exosomes on the macrophages. Furthermore, treatments of either exosomes or exosomes with miR-223-3p successfully attenuated inflammatory responses in the liver of autoimmune hepatitis and inflammatory cytokine release in both the liver and macrophages. The mechanism may be related to the regulation of miR-223-3p level and STAT3 expression in the liver and macrophages. These results suggest that MSC-exosomes can be used to deliver miR-223-3p for the treatment of autoimmune hepatitis.

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.