• Title/Summary/Keyword: Attachment method

Search Result 698, Processing Time 0.03 seconds

Effects of the Tagging methods on the Growth and Survival of Abalone Juvenile, Haliotis discus hannai (전복, Haliotis discus hannai 치패의 성장과 생존에 미치는 표지의 영향)

  • Kim Bong Seok;Lee Yun Ho;Park Doo Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.3
    • /
    • pp.282-288
    • /
    • 2002
  • This study was carried out to investigate the optimum tagging method of the abalone juvenile, Haliotis discus hannai in indoor culture system from May 2000 to January2001. Tagging methods were shell drilling, copper-wire tagging at the respiratory pore and nut gluing on the shell. The attachment rates of the shell showed high in the 2- and 3 cm bolt-nut tagged groups, about over $89.5\%$, whereas shell drilling groups on the shell were about $18.5\%$. The internal coating rates tagged with bolt-nut were over $96.6\%$, while those tagged with copper wire were less than $17.1\%$. Growths in the all marked and tagged experimental groups comparing with control groups were not significantly different (p>0,05). Survivals in all tagging groups except shell drilling and nut gluing groups in the 5 cm abalone were over $95\%, Accordingly, all juvenile groups were not affected by the tagging methods in terms of the growth and survival on the abalones. Based on these results, the micro bolt-nut tagging was the most effective method in abalone.

A Study of the Apply Proximity Sensor for Improved Reliability Axle Detection (열차 차축검지 신뢰성 향상을 위한 근접센서 방식 Axle Counter 적용 연구)

  • Park, Jae-Young;Choi, Jin-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5534-5540
    • /
    • 2015
  • This In the railway signaling system, applications of axle counter in addition to track circuit goes on increasing for detecting train position. Consequently, this paper compares sensor methods of axle counter with between geo-magnetism method and proximity sensor method. And it presents differences and results, to improve reliabilities of train detection and axle counting. Also, this article presents an applied result which is based on field experience, with regard to installation, considering attachment condition of sensor part for accurate axle counting. This study acquires expandability that is able to perform not only axle counting function but also various other functions (direction detection of train, speed detection of train, and so on). It was a result of a change of design in order to judge phase difference of sensors, to improve reliability of axle counting. Furthermore, it does not subordinate to characteristics (type, weight of train). And it is confirmed that the omission of axle counting was not occurred in 350km/h. This was the result of Lab test after the construction of transfer equipment of trial axle and Test Bed for axle counting. Both of them are self-productions. Through this, it prepares foundation which is able to apply not only to train detection but also to speed of passing trains, formation number of trains, detector locking condition - when the train passes the section of switch point, and level crossing devices. Furthermore, it would be judged to contribute safety train operation if proximity sensor method applies to the whole railway signaling system from now on.

Cellular activities of osteoblast-like cells on alkali-treated titanium surface (알칼리 처리된 타이타늄 표면에 대한 골아 유사세포의 세포 활성도)

  • Park, Jin-Woo;Lee, Deog-Hye;Yeo, Shin-Il;Park, Kwang-Bum;Choi, Seok-Kyu;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.sup2
    • /
    • pp.427-445
    • /
    • 2007
  • To improve osseointegration at the boneto-implant interface, several studies have been carried out to modify titanium surface. Variations in surface texture or microtopography may affect the cellular response to an implant. Osteoblast-like cells attach more readily to a rougher titanium surface, and synthesis of extracellular matrix and subsequent mineralization were found to be enhanced on rough or porous coated titanium. However, regarding the effect of roughened surface by physical and mechanical methods, most studies carried out on the reactions of cells to micrometric topography, little work has been performed on the reaction of cells to nanotopography. The purpose of this study was to examme the response of osteoblast-like cell cultured on blasted surfaces and alkali treated surfaces, and to evaluate the influence of surface texture or submicro-scaled surface topography on the cell attachment, cell proliferation and the gene expression of osteoblastic phenotype using ROS 17/2.8 cell lines. In scanning electron micrographs, the blasted, alkali treated and machined surfaces demonstrated microscopic differences in the surface topography. The specimens of alkali treatment had a submicro-scaled porous sur-face with pore size about 200 nm. The blasted surfaces showed irregularities in morphology with small(<10 ${\mu}m$) depression and indentation among flatter-appearing areas of various sizes. Based on profilometry, the blasted surfaces was significantly rougher than the machined and the alkali treated surfaces (p$TiO_2$) were observed on alkali treated surfaces, whereas not observed on machined and blasted surfaces. The attachment morphology of cells according to time was observed by the scanning electron microscope. After 1 hour incubation, the cells were in the process of adhesion and spreading on the prepared surfaces. After 3 hours, the cells on all prepared surfaces were further spreaded and flattened, however on the blasted and alkali treated surfaces, the cells exhibited slightly irregular shapes and some gaps or spaces were seen. After 24 hours incubation, most cells of the all groups had a flattened and polygonal shape, but the cells were more spreaded on the machined surfaces than the blasted and alkali treated surfaces. The MTT assay indicated the increase on machined, alkali treated and blasted surfaces according to time, and the alkali treated and blasted surfaces showed significantly increased in optical density comparing with machined surfaces at 1 day (p<0.01). Gene expression study showed that mRNA expression level of ${\alpha}\;1(I)$ collagen, alkaline phosphatase and osteopontin of the osteoblast-like cells showed a tendency to be higher on blasted and alkali treated surfaces than on the machined surfaces, although no siginificant difference in the mRNA expression level of ${\alpha}\;1(I)$ collagen, alkaline phosphatase and osteopontin was observed among all groups. In conclusion, we suggest that submicroscaled surfaces on osteoblast-like cell response do not over-ride the one of the surface with micro-scaled topography produced by blasting method, although the microscaled and submicro-scaled surfaces can accelerate osteogenic cell attachment and function compared with the machined surfaces.

SUPEROXIDE DISMUTASE - AND CATALASE - ACTIVITY IN BLOOD PLASMA AND RED BLOOD CELLS IN PERIODONTITIS (치주염 환자의 혈장과 적혈구내 S.O.D와 Catalase 활성도에 관한 연구)

  • Hwang, Seung-Hwan;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.167-178
    • /
    • 1995
  • It has been believed that the increased release of free oxygen radicals and their tissue damaging potency might be a contributing factor in the pathogenesis of periodontal disease. Antioxidant enzymes such as superoxide dismutase(SOD) and catalase can protect the tissue damage from the free oxygen radicals($O_2^-,H_2O_2$, and $OH^-$). In order to investigate the SOD- and catalase - activity in the blood plasma and red blood cells(RBCs) of the patients with perodontitis, 19 male periodontitis patients($25{\sim}35$ years old) who had good general health, more than 10 teeth with severely inflamed gingiva, attachment loss more than 6mm and bone loss were selected as periodontitis group, and 13 male volunteers($22{\sim}29$ years old) with good general and periodontal health were selected as normal group. After blood plasma and RBC were separated from peripheral blood of 2ml collected from antecubital vein of each subject, SOD- activity in blood plasma and RBCs was measured by the same method that Paoletti et al. did, and catalase - activity in RBC was measured by the same method that Beers et al, did. The difference of SOD- and catalase - activity between the normal and the periodontitis groups was statistically analyzed by Student t-test with SPSS/PC program.The results were as follows : 1. SOD activity in blood plasma was significantly lower in the periodontitis group($1.986{\pm}0.893$) than in the normal group($3.324{\pm}1.044$)(p<0.05). 2. There was no statistical significance in the difference of SOD- activity in RBCs between the periodontitis group($7.753{\pm}3.206$) and the normal group($8.116{\pm}1.192$)(p$242.8{\pm}45.6$) than in the normal group($280.2{\pm}32.6$)(p

  • PDF

STUDY ON THE ALTERATION OF GLUTATHIONE PEROXIDASE & CATALASE ACTIVITY IN PERIPHERAL BLOOD OF PERIODONTAL DISEASE PATIENTS (치주질환 환자의 말초혈액내 glutathione peroxidase와 catalase의 활성 변화에 관한 연구)

  • Kim, Byung-Ok;Kim, Chan-Jin;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.529-538
    • /
    • 1995
  • It has been believed that the increased release of free oxygen radicals ($O_2^-,H_2O_2$, and $OH^-$) might be a factor in the pathogenesis of periodontal diseases. Antioxidant enzymes such as glutathione peroxidase(GSH-PX) and catalase can protect the tissue damage from the $H_2O_2$. In order to investigate the GSH-PX and catalase activity in the blood plasma and red blood cells(RBCs) of the patients with periodontitis, 19 patients who had good general health, attachment loss more than 6 mm and bone loss were selected as periodontitis group, 7 patients who had severely inflamed gingiva were selected as gingivitis group, and 15 volunteers with good general and periodontal health were selected as normal group. 17 of 26 patients were performed scaling and root planing to reduce the gingival inflammation for gingivitis and periodontitis groups, and were selected as posttreatment group. After blood plasma and RBCs were collected and separated 1 ml of peripheral blood from each subject, GSH-PX activity in blood plasma and RBCs was measured by the same method that Stefan et al. did, and catalase activity in RBCs was measured by the same method that Beers et al. did. The difference of GSH-PX and catalase activity between normal, gingivitis, and periodontitis groups was statistically analyzed by ANOVA with SPSS/PC+ program, and the difference between pretreatment and posttreatment groups was analyzed by Student t-test. The results were as follows : 1. GSH-PX activity in blood plasma was significantly lower in the gingivitis group($0.8683{\pm}0.0658$), periodontitis group($0.7130{\pm}0.1333$) than in the normal group($1.0241{\pm}0.0801$)(p<0.05), and GSH-PX activity in RBCs was significantly lower in the gingivitis groupt. $0.8156{\pm}0.1167$), periodontitis group($0.7533{\pm}0.1185$) than in the normal group($l.1963{\pm}0.2044$)(P<0.05), but there was no statistical significance in the difference of GSH-PX activity in RBCs between the gingivitis group and periodontitis group(p>0.05). 2. Catalase activity in RBCs was siginficantly lower in the periodontitis group($117.34{\pm}35.01$) than in the normal group($l52.38{\pm}32.09$)(p<0.05). 3. GSH-PX activity in blood plasma was significantly increased in the posttreatment groupe $1.0376{\pm}0.2820$) compared to the pretreatment group(0.7608 0.1600) (p<0.05), and GSH-PX activity in RBC was significantly increased in the posttreatment group($1.0421{\pm}0.2330$) compared to the pretreatment group($0.7728{\pm}0.1210$)(p<0.05). 4. There was no statistical significance in the difference of catalase activity in RBCs between the pretreatment group($112.04{\pm}43.65$) and posttreatment group($l33.41{\pm}39.16$)(p>0.05).The results, within the limits of the present experiment, suggest that the lowered activity of GSH-PX and catalase in blood plasma and RBCs may be related with periodontopathogenesis.

  • PDF

Discussion about the Self Disposal Guideline of Medical Radioactive Waste (의료용 방사성폐기물 자체처분 가이드라인에 관한 고찰)

  • Lee, Kyung-Jae;Sul, Jin-Hyung;Lee, In-Won;Park, Young-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.13-27
    • /
    • 2017
  • Purpose In the procedure of domestic medical radioactive self-disposal, there are many requests of supplementation and difficulties on the screening process. In this regard, presentation of basic guideline will improve the work processing efficiency of medical institution radioactive waste. From 2015 to 2016, We reviewed and compared a supplementary requests of domestic fifteen medical institution radioactive self-disposal Plan & Procedure manual. In connection with this, we derive the details of the radioactive waste document based on the relative regulation of nuclear safety Act. The representative supplementary requests of Korea Institute of Nuclear Safety are disposal method of non-flammability radioactive waste, storage method of scheduled self-disposal waste, the legitimacy of self-disposal and pre-treatment of self-disposal, reference radioactivity of disused filter and output of storage period, attachment the evidential matter of measurement efficiency when using a gamma counter. Through establishing a medical radioactive waste guideline, we can clearly suggest a classification standard of radioactive nuclide and the type of occurrence. As a result, we can confirm the reduction of examination processing period while preparing a self-disposal document and there is no spending expenses for business agency. Also, the storage efficiency of facility will better and reduce the economic expenses. On the basis of this guideline, we will expect a contribution to the improvement of work efficiency for officials who has a working-level difficulty of radioactive waste self-disposal.

  • PDF

Cell cycle-dependent entry of Toxoplasma gondii into synchronized HL-60 cells (세포 주기 변화에 따른 Toxoplasmu gondii의 침투 양상)

  • 윤지혜;남호우
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.2
    • /
    • pp.121-128
    • /
    • 1991
  • The degree of attraction of Toxoplasma gondii to vertebrate cells varies with cell type and cell phase. Human promyelocytic leukemia cells, HL-60, were synchronized by double thymidine block method and co-cultured with Toxoplasma for 1 hr at each cell stage to investigate the cell cycle specific susceptibility of parasites to host cells. For 30 hr the average number of Texoplasma that invaded was a little changed except at 3 hr from G1/S phase boundary which concurred with the peak point of DNA synthesis. At 3 hr which is a relatively short interval compared to whole S phase, modification of cells by parasitic invasion was most remarkable. The number of Toxoplasma that penetrated was increased to more than sin times. The shape of the cells became sludgy and almost indiscernible by strong accessibility of parasites only for an hour of mfd-S phase. The same auctuation was also observed at the second peak of S phase but weakly. This suggests that there be surface molecules concerning with the attachment of Texoplasma to the host cells, which is expressed at special point of S phase. further studies on the specific protein or similar molecules related could be carried out using synchronized HL-60 cells.

  • PDF

Arthroscopic Evaluation of Allogenic Meniscal Transplantation (반월상 연골 동종 이식술 후 이차 관절경 소견)

  • Choi Jeong-Ki;Son Il-Jin;Lee Chun-Tek;Kim Sung-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.147-152
    • /
    • 2003
  • Purpose : The purpose of this study was to evaluate the arthroscopic findings of the transplanted human allogenic meniscus including MRI changes at follow up. Materials and Methods : From Oct. 1999 to Jun. 2002, nine patients underwent arthroscopic evaluation at follow-up. We used nonirradiated cryopreserved meniscus allograft for 6 cases and fresh-frozen for 3 cases. We used bone-plug method for medial meniscus and bone-bridge method for lateral meniscus to fix the transplanted meniscus. The average follow-up time was 13 months. We evaluated the result by lysholm score, MRI and second-look arthroscopic finding. Results : The second-look arthroscopy after allogenic meniscal transplantation revealed that grafts were well incorporated with surrounding capsular tissue. But one case showed wear on the post horn and the other case which was operated at other local clinic showed tear of the anterior hem due to non-anatomic placement of bone bridge. There was improvement of average Lysholm score form 64 to 87. Conclusion : Second-look arthroscopy revealed excellent incorporation of the allograft with firm attachment and early clinical results are satisfactory. But further studies are necessary to assess whether meniscal transplantation can prevent progressive degenerative changes.

  • PDF

Study of Spin Jig Development for Cleaning of the PCB component (PCB기판 세척용 스핀 지그개발에 관한 연구)

  • Lee, Seung-Chul;Park, Suk-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4736-4741
    • /
    • 2014
  • This study examined PCB component cleaning on a PCB component surface, which has defects of precipitation type washing (existing rinse method), sealant and foreign material formed in the adhesive process that could not be removed easily. The spin jig was developed for PCB component cleaning, in which the PCB component settled down, to solve the conventional problem of the removal of foreign material with the centrifugal force by high speed rotation. The results are as follows. With decreasing fraction defect in PCB component washing, the development and substrate damage decreased by more than 80% according to the abstergent in the rotary type using the centrifugal force in the existing precipitation type. When the base plate showed a large difference with the time to include the process after washing the design using the existing method, easy attachment and separation of the PCB component could be possible. The washing time was enhanced 90% compared to the existing time. The reliability of the security and washing collaboration of the design and stability of the cleaning process could be secured so that there was no phenomenon of secession, the PCB component fixed for a cleansing rotation jig could maintain a fixed force by the centrifugal force. The stability and reliability of the washing process and the defective rate could be improved to less than 1%.

Immediate Connection of Customized Zirconia Abutment Using Flapless Guided Surgery: A Clinical Report (무절개 수술을 이용한 맞춤형 지르코니아 지대주의 즉시 장착 증례)

  • Lee, Gyeong-Je;Choi, Byung-Ho;Kim, Hee-Jun;Jung, Seng-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.201-212
    • /
    • 2012
  • There are some similar aspects at histological and morphological characteristics between the peri-implant tissue and periodontal tissue and the direct attachment between the titanium and soft tissue around the implant called as "Functional ankylosis" can prevent the apical infiltration of inflammatory and bone resorption around implant. But, the repeated connection and disconnection of the abutment can destroy the mucosal barrier of soft tissue around the implant and can cause the marginal bone resorption. The amount of marginal bone resorption may reduced if the prosthetic abutment is placed at that time of surgery. Connection of the prosthetic abutment at surgery was limited because the low accuracy of conventional method, but by using of Cone Beam Computed Tomography(CBCT) and guide surgery, the 3-dimensional accuracy of implant placement became much higher than before and it became possible. This is a clinical case of immediate connection of prosthetic abutment and provisional restoration by using of precise CBCT diagnosis and pre-fabricated zirconia customized abutment at surgery and the alternative method is described in this article because of the clinically contentable results.