• Title/Summary/Keyword: Attachment Energy

Search Result 156, Processing Time 0.029 seconds

Diffusion Coefficients in $SF_6-Ar$ Gas used by MCS-BE Algorithm (MCS-BEq 알고리즘에 의한 $SF_6-Ar$ 혼합기체의 확산계수)

  • Kim, Sang-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.298-301
    • /
    • 2006
  • This paper describes the electron energy distribution function characteristics in $SF_6-Ar$ gas calculated for range of E/N values from $50\sim700[Td]$ by the Monte Carlo simulation(MCS) and Boltzmann equation(BE) method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters are obtained by time of flight(TOF) method. In this dissertation the results of the combined experimental and theoretical studies designed to understand and predict the spatial growth and transport coefficients for electrons in $SF_6$ and $SF_6-Ar$ mixtures have described. The ionization and attachment coefficients in pure $SF_6$ and $SF_6-Ar$ mixtures have been calculated over the range of 10$SF_6$ molecule and for Ar atom proposed by other authors. The results obtained in this work will provide valuable information on the fundamental behaviors of electrons in weakly ionized gases and the role of electron attachment in the choice of better gases and unitary gas dielectrics or electro negative components in dielectric gas mixtures.

  • PDF

A novel approach for optimal DG allocation in distribution network for minimizing voltage sag

  • Hashemian, Pejman;Nematollahi, Amin Foroughi;Vahidi, Behrooz
    • Advances in Energy Research
    • /
    • v.6 no.1
    • /
    • pp.55-73
    • /
    • 2019
  • The cost incurred by voltage sag effect in power networks has always been of important concern for discussions. Due to the environmental constraints, fossil fuel shortage crisis and low efficiency of conventional power plants, decentralized generation and renewable based DG have become trends in recent decades; because DGs can reduce the voltage sag effect in distribution networks noticeably; therefore, optimum allocation of DGs in order to maximize their effectiveness is highly important in order to maximize their effectiveness. In this paper, a new method is proposed for calculating the cost incurred by voltage sag effect in power networks. Thus, a new objective function is provided that comprehends technical standards as minimization of the cost incurred by voltage sag effect, active power losses and economic criterion as the installation and maintenance costs of DGs. Considering operational constraints of the system, the optimum allocation of DGs is a constrained optimization problem in which Lightning Attachment procedure optimization (LAPO) is used to resolve it and is the optimum number, size and location of DGs are determined in IEEE 33 bus test system and IEEE 34 bus test system. The results show that optimum allocation of DGs not only reduces the cost incurred by voltage sag effect, but also improves the other characteristics of the system.

Antifouling technology and sea trial verification according to surface treatment (표면 처리를 통한 친환경 방오 기술 및 실해역 평가 연구)

  • Han, Deok-Hyun;Koh, Hyeok-Jun;Jung, Hang-Chul
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.425-432
    • /
    • 2022
  • Antifouling paints that inhibit the attachment and contamination of marine organisms mainly use TBT compounds, but because of their toxic components, they cause ecosystem disturbance and environmental destruction problems, so It is necessary to research eco-friendly antifouling paints that are easy to maintain and effective antifouling technologies. In this study, physical surface treatment of silane coating and chemical antifouling technology were applied to the metal surface to secure the stability of the surface of the marine structure and inhibit the attachment and growth of marine organisms. Adhesion of marine organisms was evaluated according to the coating conditions through surface evaluation of the charged material for 15 months in the waters of the west coast of Korea. In accordance with ASTM D6990-05, antifouling properties fouling rates (FR) and physical degradation rates(PDR) were evaluated through visual inspection of the evaluation specimens. As a result of evaluating the antifouling performance of the coated surface, it was confirmed that the antifouling performance was maintained at the 50% level even after 15 months in the sample subjected to physical processing and silane coating.

A Study on the electron energy diffusion function of the sulphur hexaflouride ($ SF_6$가스의 전자에너지 분포함수에 관한 연구)

  • 김상남;하성철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • The electron energy distributions function were analysed in sulIitur hexaflowide at E/N : 500~800(Td) for a case of non-equilibrium region in the nran electron energy. This papa- describes the electron transport characteristics in $ SF_6$ gas calculated for range of E/N values from 150~800(Td) by the Monte Carlo simulation and Boltzmann equation Irethod using a set of electron collision cross sectioos determined by the authors and the values of electron swarm parameters. The results gained that the value of an electron swarm parameter such as the electron drift velocity, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients agree with the experimental and theoretical for a range of E/N. The properties of electron avalanches in an electron energy non-equilibrium region.region.

  • PDF

Study on the Electron Transport Coefficient in Mixtures of $CF_4$ and Ar ($CF_4-Ar$ 혼합기체의 전자수송계수에 관한 연구)

  • Kim, Sang-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Study on the electron transport coefficient in mixtures of CF4 and Ar, have been analyzed over a range of the reduced electric field strength between 0.1 and 350[Td] by the two-term approximation of the Boltzmann equation (BEq.) method and the Monte Carlo simulation (MCS). The calculations of electron swarm parameters require the knowledge of several collision cross-sections of electron beam. Thus, published momentum transfer, ionization, vibration, attachment, electronic excitation, and dissociation cross-sections of electrons for $CF_4$ and Ar, were used. The differences of the transport coefficients of electrons in $CF_4$ mixtures of Ar, have been explained by the deduced energy distribution functions for electrons and the complete collision cross-sections for electrons. The results of the Boltzmann equation and the Monte Carlo simulation have been compared with the data presented by several workers. The deduced transport coefficients for electrons agree reasonably well with the experimental and simulation data obtained by Nakamura and Hayashi. The energy distribution function of electrons in $CF_4-Ar$ mixtures shows the Maxwellian distribution for energy. That is, $f({\varepsilon})$ has the symmetrical shape whose axis of symmetry is a most probably energy. The proposed theoretical simulation techniques in this work will be useful to predict the fundamental process of charged particles and the breakdown properties of gas mixtures. A two-term approximation of the Boltzmann equation analysis and Monte Carlo simulation have been used to study electron transport coefficients.

Drift Velocities for Electrons in $SF_6$-Ar Mixtures Gas by MCS-Beq Algorithm (MCS-BEq에 의한 $SF_6-Ar$혼합기체(混合氣體)의 전자(電子) 이동속도(移動速度))

  • Kim, Sang-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.29-33
    • /
    • 2005
  • Energy distribution function for electrons in $SF_6$-Ar mixtures gas by MCS-BEq algorithm has been analysed over the E/N range $30{\sim}300$[Td] by a two term Boltana equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other, authors, experimentally the electron swarm parameters for 0.2[%} and 0.5[%] $SF_6$-Ar mixtures were measured by time-of-flight(TOF) method. The result show that the deduced electron drift velocities, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients and mean energy agree reasonably well with theoretical for a rang of E/N values. The results obtained from Booltemann equation method and Monte Carlo simulation have been compared with present and previously obtained data and respective set of electron collision cross sections of the molecules.

Optimization of the Spring Design Parameters of a Circuit Breaker to Satisfy the Specified Dynamic Characteristics

  • Gil Young;Kwang Young
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.4
    • /
    • pp.43-49
    • /
    • 2004
  • A spring-actuated linkage system is used to satisfy the desired opening and closing characteristics of the electric contacts of a vacuum circuit breaker. If the type of a circuit breaker and the structure of the linkage system are predetermined, then design parameters such as stiffness, free length and attachment points of the spring become the important issues. In this paper, based on the energy conservation, the total system energy is constant throughout the operating range of the mechanism; a systematic procedure to optimize the spring design parameters is developed and applied to a simplified mechanism of a circuit breaker. The developed procedure is converted to the environment of the multi-body dynamics program, ADAMS for an in-depth consideration of the complex dynamics of a circuit breaker mechanism.

Monte carlo simulation for electron transport characteristics in sulphur hexaflouride ($SF_6$ 가스의 전자수송특성에 관한 몬테칼로시뮬레이션)

  • 하성철;서상현
    • Electrical & Electronic Materials
    • /
    • v.9 no.7
    • /
    • pp.660-667
    • /
    • 1996
  • The electron transport characteristics in $SF_6$ gas is calculated for range of E/N values from 150 -800(Td) by the Monte Carlo simulation using a set of electron collision cross sections determined by the authors. The results suggest that the value of an electron swarm parameter such as the electron drift velocity, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients in nearly agreement with the respective experimental and theoretical for a range of E/N. The electron energy distributions function were analysed in sulphur hexaflouride at E/N:500 and 800(Td) for a case of the equilibrium region in the mean electron energy. The validity of the results obtained has been confirmed by a Time of Flight method also investigated as a set of electron collision cross section for sulphur Hexaflouride.

  • PDF

Drift Velocities for Electrons in $SF_6$-Ar Mixtures Gas by Simulation (시뮬레이션에 의한 $SF_6$-Ar혼합기체(混合氣體)의 전자(電子) 이동속도(移動速度))

  • Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1566-1567
    • /
    • 2006
  • Energy distribution function for electrons in $SF_6$-Ar mixtures gas used by MCS-BEq algorithm has been analysed over the E/N range $30{\sim}300$[Td] by a two term Boltzmann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2[%] and 0.5[%] $SF_6$-Ar mixtures were measured by time-of-flight (TOF) method. The results show that the deduced electron drift velocities, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients and mean energy agree reasonably well with theoretical for a rang of E/N values.

  • PDF

Optimization of the Spring Design Parameters of a Circuit Breaker for Satisfying Specified Dynamic Characteristics (규정된 동적특성을 위한 회로차단기의 스프링 설계변수의 최적화)

  • 안길영;정광영
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.3
    • /
    • pp.132-138
    • /
    • 2004
  • In a vacuum circuit breaker mechanism, a spring-actuated linkage system is used to satisfy the desired opening and closing characteristics of electric contacts. If the type and structure of the linkage system required to the circuit breaker is predetermined, the stiffness, free length and attachment points of a spring become the important design parameters. In this paper, based on the energy conservation that the total system energy is constant throughout the operating range of the mechanism, a systematic procedure for optimizing the spring design parameters is developed and applied to the simplified mechanism of a circuit breaker. Then, in order to consider the complex dynamics of the circuit breaker mechanism rather well, the developed procedure is converted to the environment of a multi-body dynamics program ADAMS.