• 제목/요약/키워드: Attached type

검색결과 1,069건 처리시간 0.028초

표면염화물량 산정을 위한 건축마감재별 비래염분 부착율 분석 (Attachment Rate Analysis of Airborne Chlorides by Construction Finish Material to Measure the Amount of Chlorides on the Surface)

  • 조규환;지동헌;정재민;박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.57-58
    • /
    • 2014
  • For durability design to protect against chloride-induced corrosion, it is important to estimate the amount of chlorides on the surface. However, it is difficult to estimate the airborne chlorides, a boundary condition, due to the difference between the amount of chlorides attached to a surface of an actual structure and that in the air. Therefore, in this study the attachment rate analysis of airborne chlorides was evaluated for 13 types of finish materials. As a result, despite differences in the amount of airborne chlorides according to the finishing type, it was found that 60 percent of airborne chlorides were attached to mortar, 30 percent were attached to steel, and 25 percent were attached to tiles compared with the amount of chlorides in the air.

  • PDF

종합병원 병동부의 간호사 대기실 및 관련공간의 효율적인 구성에 관한 연구 (A Study on the efficient Composition of a Nurse Station and Attached Spaces in General Hospitals)

  • 정선애;김형우
    • 한국실내디자인학회논문집
    • /
    • 제18호
    • /
    • pp.44-50
    • /
    • 1999
  • The purpose of this study is to suggest reasonable composition and layout of a nurse station and attached spaces-which are central sector of patient caring in the inpatient department- in the view of funtional efficiency. The method of this study is examining other studies and case study of inpatient department in general hospitals. through this research we find out the plan type of inpatient department and layout of nurse station and attached spaces in the view of 'the efficiency of circulation' and 'the easiness of observation' . It is also found out that the nursing delivery system effects to the composition and layout of nurse station attached spaces. Therefore, the efficient design of inpatient department by this study can accomplish 'patient-focused' medical environment and aid to develop their health.

  • PDF

생태복원용 식물매트 개발에 관한 기초연구 (A Basic Study on the Development of the Plant-Mat for Ecological Restoration)

  • 이동근;이준우;심상렬
    • 한국환경복원기술학회지
    • /
    • 제6권2호
    • /
    • pp.78-88
    • /
    • 2003
  • This study was conducted to develop the plant-mat for ecological restoration which was formed as the thin multi-layers of woven nets, soil media, seeds, etc. The experimental site was selected at a slope of 240$m^2$ at the rear of Design College of Sangmyung University and divided into 8 sub-experimental plots (20$m^2$ each) according to mat types. (forest-type and grass-type mats with and without seed attachment, respectively) Also, the existing vegetation plot and the no-treatment plot were included in this experiment for comparison. The experiment construction was conducted on September 3, 2002. Mat covered plots regardless of seed attachment showed nearly no signs of erosion even if rainy season in summer compared to the no-treatment plot. Vegetation monitoring result showed that germination rates were somewhat high in both forest and grass-type mats without seed attachment in the initial germination stage. Although germination rates of seed attached mats were somewhat slower than non-seed attached mats in the germination stage, but over time, it showed a good rooting and shooting environment for germinated tree and grass species because of soil media existence within the mat. This indicates that while non seed-attached mats require follow-up maintenance, seed-attached mats does not require maintenance after rooting and germination.

덧유리 및 방풍재 적용을 통한 슬라이딩 창의 단열 및 기밀성능 개선효과 분석 (The Effect of the Attached Glazing and Windbreak on the Thermal Performance and Air Tightness of Sliding window)

  • 배민정;강재식;최경석;최현중
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.59-65
    • /
    • 2017
  • Purpose: Thermal performance and air tightness of window are improved for the building energy efficiency. As the deteriorated houses are increased, the improve measures with low cost and easy installation are developed in the energy performance of window. Attached glazing and windbreak can be easily applied to the window with low cost. In this paper, the effect of the attached glazing and windbreak on the thermal performance and air tightness of window is analyzed as the measure to improve performance of window. Method: Thermal transmittance of glazing is evaluated through WINDOW simulation according to thickness of attached glazing and air cavity. Based on the simulation results, thermal transmittance, air tightness and condensation resistance performance of four cases are tested according to Korea standards. One type of PVC sliding double window is chosen as the specimen. For the analysis on low performance of window, the outside of window is excluded in the PVC sliding double window. Result: This study shows that thermal performance of glazing can be increased by the application of attached glazing. Furthermore, lower thermal performance of glazing can obtain the higher effect of attached glazing. The application of attached glazing and windbreak can effect on increasing thermal performance and air tightness of window.

Higher Biomass Productivity of Microalgae in an Attached Growth System, Using Wastewater

  • Lee, Seung-Hoon;Oh, Hee-Mock;Jo, Beom-Ho;Lee, Sang-A;Shin, Sang-Yoon;Kim, Hee-Sik;Lee, Sang-Hyup;Ahn, Chi-Yong
    • Journal of Microbiology and Biotechnology
    • /
    • 제24권11호
    • /
    • pp.1566-1573
    • /
    • 2014
  • Although most algae cultivation systems are operated in suspended culture, an attached growth system can offer several advantages over suspended systems. Algal cultivation becomes light-limited as the microalgal concentration increases in the suspended system; on the other hand, sunlight penetrates deeper and stronger in attached systems owing to the more transparent water. Such higher availability of sunlight makes it possible to operate a raceway pond deeper than usual, resulting in a higher areal productivity. The attached system achieved 2.8-times higher biomass productivity and total lipid productivity of $9.1g\;m^{-2}day^{-1}$ and $1.9g\;m^{-2}day^{-1}$, respectively, than the suspended system. Biomass productivity can be further increased by optimization of the culture conditions. Moreover, algal biomass harvesting and dewatering were made simpler and cheaper in attached systems, because mesh-type substrates with attached microalgae were easily removed from the culture and the remaining treated wastewater could be discharged directly. When the algal biomass was dewatered using natural sunlight, the palmitic acid (C16:0) content increased by 16% compared with the freeze-drying method. There was no great difference in other fatty acid composition. Therefore, the attached system for algal cultivation is a promising cultivation system for mass biodiesel production.

현장검증시험에 의한 선단변형 PHC말뚝들의 연직하중 지지특성에 관한 연구 (Axial Bearing Characteristics of Tip-transformed PHC Piles through Field Tests)

  • 최용규;김명학
    • 한국지반공학회논문집
    • /
    • 제34권11호
    • /
    • pp.107-119
    • /
    • 2018
  • PHC말뚝, 확장판 선단부착 PHC말뚝, 강관 선단부착 PHC말뚝을 현장 시험 부지에서 시험시공하였다. 이들 선단변형 PHC말뚝들에 대하여 하중전이측정이 수반된 연직압축정재하시험을 실시하였으며 시공직후 항타후 동재하시험을 수행하였다. 또한 선단부만 그라우팅한 선단변형PHC말뚝에 대한 연직압축정재하시험도 실시하였다. 3가지 다양한 선단말뚝들 즉, PHC말뚝, 확장판 선단부착 PHC말뚝, 강관 선단부착 PHC말뚝의 하중-침하량 거동은 거의 동일한 양상을 나타내었다. 따라서 말뚝이 선단지지층에 근입된 길이가 동일하고 말뚝 본체의 직경이 동일할 경우 확장판 선단부착 PHC말뚝 및 강관 선단부착 PHC말뚝의 지지력 증대 효과는 거의 없는 것으로 나타났다. 최종재하하중단계에서 PHC말뚝, 확장판 선단부착 PHC말뚝, 강관 선단부착 PHC말뚝의 주면마찰력은 각각 전체 재하하중의 95.8%, 95.6%, 97.8%를 분담하였으며, 선단지지력은 전체 재하하중의 4.2%, 4.4%, 2.2%를 분담하였다.

롤링을 통한 창호부착형 에어캡 모듈 개발 (Development of the Aircap Module Attached to the Window Through Rolling)

  • 허지운;서장후;김용성;이행우
    • 설비공학논문집
    • /
    • 제29권11호
    • /
    • pp.559-569
    • /
    • 2017
  • Various studies examining how to conserve building energy have been conducted recently. From such studies it has been determined that insulation performance of an aircap is viable and therefore aircaps are used as material for improving insulation performance of windows. However, the aircap for improving insulation performance of a window is attached on the front, causing infringement of the prospect right. Therefore, the purpose of this study is to develop an aircap module attached to the window through rolling, conducting performance verification throughfull-scale testbed and verifying its effectiveness. Findings of this study are as follow : 1) The module suggested in this study enables setting of an area wherein the aircap is attached through rolling so that the aircap rolls up using Velcro tape, and an insulation bar is suggested to block the gap between the aircap and window glass. 2) When the aircap is applied to the window, consumption of lighting energy increased during summer and winter by 2.8%~16.4% and 0%~76.2% respectively in comparison to no aircap application, indicating that it is unsuitable for conserving lighting energy. 3) In terms of conserving cooling and heating energy, an advantageous or effective aircap attachment method is the method whereby an aircap is attached to the front surface of a window. However, the method whereby an aircap is attached to a part of a window and where no aircap is attached increases consumption of cooling and heating energy during summer and winter by 6.0%~35.7% and 2.7%~41.6% respectively in comparison to the method wherein an aircap is attached to the front surface of a window. 4) In consideration of conserving cooling, heating and lighting energy, the attachment of an aircap to the front surface of window is the most appropriate method, and it is appropriate to attach the aircap at a position that is 1,500 mm or higher from the floor to secure the prospect right and minimize energy loss.

용기포장 액상 식품의 물류관리를 위한 RFID 시스템 개발(I) - 물의 높이에 따른 RFID 인식성능 분석 - (Development of RFID Management System for Packaged Liquid Food Logistics (I) - Analysis of RFID Recognition Performance by Level of Water -)

  • 김용주;김태형
    • Journal of Biosystems Engineering
    • /
    • 제34권6호
    • /
    • pp.454-461
    • /
    • 2009
  • The purpose of this study is to analyze the RFID recognition performance by level of water. A 13.56 MHz RFID management system for packaged liquid food logistics is consisted of antenna, reader, passive type tags, and embedded controller. The tests were conducted at different level of water, distances between tag and antenna, and position of attached tags. To analyze the RFID recognition performance, maximum recognition distances for a container and recognition rates for a logistics made of 27 containers were measured and analyzed. The maximum recognition distance for a container was different depending on position of attached tags, and attached tag at upside position showed a good performance. But, the recognition rate of 27 containers showed a good ability for attached tags at front side position, 30~35 cm distance to antenna, and water level 1. Therefore, to manage packaged liquid food logistics using RFID system, position of attached tag, distances between tag and antenna, and level of water should be considered.

FMS운용을 위한 일정계획용 소프트웨어 (Development of Scheduling Software for Flexible Manufacturing System)

  • 윤덕균;황의철
    • 산업경영시스템학회지
    • /
    • 제14권24호
    • /
    • pp.53-69
    • /
    • 1991
  • This paper is concerned with software developments for scheduling and sequencing of FMS. The scheduling algorithms are developed for 3 types of FMS:single machine type FMS, flowshop type FMS. assembly line type FMS. For the single machine type FMS. full enumeration algorithm is used. For the flowshop type FMS heuristic algorithms are developed. For the assembly type FMS the exsisting PERT/CPM algorithm is applied. Numerical examples are presented for illustration of each algorithm. Each soft ware program list are attached as appendices.

  • PDF

국립대학(國立大學)의 캠퍼스 유형(類型)에 의한 대학시설(大學施設)의 특성(特性) (The Characteristics of University Institution by the Campus Types in the National Universities)

  • 김종석
    • 교육시설
    • /
    • 제6권3호
    • /
    • pp.47-53
    • /
    • 1999
  • The study surveys the university institution of 57 national university campuses in order to estimate the present condition of the national universities by the campus type. The result are as follows: 1) The university institution floor area of the comprehensive type and mixed type campuses is larger than that of other type campuses. 2) The area ratio of educational facilities and attached facilities shows a lot of differences among the scientific and engineering type campuses. 3) The educational type campuses have enough the support facilities that is library, gymnasium and etc.

  • PDF