• Title/Summary/Keyword: Atrial function, right

Search Result 26, Processing Time 0.027 seconds

Modification of the Cox-Maze Procedure for Atrial Fibrillation with Large Left Atrium ; Development of Surgical Technique to Increase the Left Atrial Contractility (좌심방 확장을 동반한 심방세동에 대한 Cox-Maze 수술법의 변형 -수술후 좌심방 수축력의 증진을 위한 수술법의 개량-)

  • 강창현;김기봉;손대원
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.249-254
    • /
    • 1999
  • Background: Recovery of the left atrial contractile function after the Cox-Maze procedure is related to the size of the left atrium. We have postulated that if too wide area of the atrium were isolated electrically, then the atrial contractile function would be impaired postoperatively. We have modified the Cox-Maze procedure to dissect each pair of the pulmonary veins separately instead of the conventional pulmonary vein encircling incision, and compared the atrial contractile function after each procedure. Material and Method: From February 1995 to October 1997, 55 cases of the Cox-Maze procedure were performed in mitral valvular heart disease. We excluded the cases that did not covert to sinus rhythm. The patient groups were divided according to the interpulmonary vein distance(IPVD) and the procedure performed. Group I was IPVD under 6.5 cm(n=30), group II was IPVD over 6.5cm and the conventional Cox-Maze III procedure was performed(n=16), and group III was IPVD over 6.5cm and the modified Cox-Maze procedure was performed(n=9). Result: Atrial contractile function was evaluated by the echocardiography follow-up between 6 months to 12 months. The right atrial contractile function recovered gradually, the recovery rate after long-term follow-up was 90% in group I, 81% in group II, and 100% in group III(p>0/05). In the left atrium the recovery rate was 63% in group I, 31% in group II(p=0.03), and 66% in group III(p>0.05). Conclusion: The modified Cox-Maze procedure may have beneficial effects on the recovery of the left atrial contractile function, however, there are no statistically significant values. Therefore, further evaluation of this procedure is necessary.

  • PDF

An Experience of Cox-maze III Procedure for Chronic Atrial Fibrillation (만성 심방세동에 대한 Cox-maze III 수술의 임상경험)

  • 김삼현;박이태;서필원;박성식;류재욱;최창휴;김명아;이명용;김영권
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.668-673
    • /
    • 1998
  • During the past several years, the maze operation has become the most effective method of treatment for chronic atrial fibrillation. When the maze procedure is done concomittantly with other cardiac operations, surgeons, in their initial experiences, may be concerned about the additional operative risks and uncertainty of the results. We performed the Cox-maze III procedure in six cases of chronic atrial fibrillation associated with mitral, mitral & aortic, or coronary arterial disease. Maze III procedure was done with open mitral commissurotomy(3 cases), mitral valve replacement(1 case), aortic and mitral valve replacement(1 case), and two-vessel coronary bypass graft(1 case). In spite of rather prolonged aortic cross clamp time, cardiac recovery was uneventful in all cases. No cases required reexploration for postoperative bleeding. All patients showed regular sinus rhythms immediate or between 2 and 20 days postoperateratively. Transient postoperative supraventricular arrhythmarias were easily controlled by various antiarrhythmic agents. In follow up evaluations, all cases showed regular sinus rhythm on ECG and the right and left atrial transport function was confirmed by Doppler echocardiography in all except one. Though our experience was limited in case number, the Cox-maze III procedure was effective in controlling the chronic atrial fibrillation without serious additional operative risks.

  • PDF

A Modified Technique in Surgical Correction of Ebstein Anomaly (Ebstein 기형 교정의 변형 술식)

  • 윤석원;윤태진;박정준;서동민
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.817-821
    • /
    • 2002
  • There are various surgical techniques in repairing Ebstein anomaly, but residual tricuspid regurgitation and compromized right heart function may ensue in some cases. We report our clinical experience of Ebstein anomaly and atrial flutter in a 19-year-old male patient who underwent simple modified tricuspid annuloplasty, hi-directional cavopulmonary shunt and cryoablation of cavotricuspid isthmus.

Congenital mitral valve stenosis in a Chinchilla cat

  • Lu, Ta-Li;Hung, Yong-Wei;Choi, Ran;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.3
    • /
    • pp.197-200
    • /
    • 2016
  • A one-year-old, 3.25 kg intact male Chinchilla cat presented with acute right hind limb paralysis. Diagnostic imaging studies found cardiomegaly with interstitial lung pattern, abnormal mitral valve leaflets without maximum opening at the end of the ventricular diastole and during atrial systole and severe mitral inflow obstruction. Based on these findings and its young age, the case was diagnosed as congenital mitral valve stenosis. Treatment was directed to stabilize clinical conditions related to heart failure, to prevent further formation of thrombus and to relieve pain associated with thromboembolism. After one month of therapy, hind limb motor function was fully recovered.

10% Pentastarch Versus 5% Albumin Solution for Volume Expansion Following Cariopulmonary Bypass in Patients Undergoing Open Heart Surgery (개심수술후 혈량 증가를 위한 10% Pentastarch와 5% Albumin 용액의 비교연구)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.27 no.3
    • /
    • pp.177-186
    • /
    • 1994
  • Pentastarch is a hydroxyethyl starch similar to hetastarch, but lower average molecular weight and fewer hydroxyethyl groups which result in enhanced enzymatic hydrolysis and faster renal elimination.This report was performed to compare the clinical efficacy and safety of 10 % pentastarch[Pentaspan , group I] for plasma volume expansion after open heart surgery with that of 5% albumin[Plasmanate, group II]. There were no statistically significant differences between the group I [n=18] and group II [n:19] in the preoperative parameters [age, sex, body weight] and operative parameters[bypass time, aorta cross clamping time]. During the first 24 hours after arrival of the patient in the surgical intensive care unit, colloid solution [500--1000 ml] was infused to maintain left atrial pressure of more than 8 mmHg, or cardiac index of 2.0 L/min/M2 of more. In results, there were 3 complications of hypotension immediately after infusion of 5 % albumin solution and 2 among the 3 patients were excluded for the study. However there was no complication after infusion of 10 % pentastarch solution. Hemodynamic responses to infusion was similar for both groups, although in group I a greater increase in both left atrial pressure[mean 1.8 versus 0.7 mmHg, p< 0.05] and right atrial pressure [mean 2.2 versus 1.7 mmHg, p < 0.05] was observed during infusion of the first 500 ml. There were no significant differences in any of the measured respiratory parameters[PaO2, intrapulmonary shunt, and effective lung compliance]. Homodilution with colloid significantly reduced hemoglobin [mean 1.2 versus 0.8 gm/dl], and serum protein and albumin level[total protein;4.8$\pm$ 0.5 versus 5.2 $\pm$0.5 gm/dl, p < 0.05: albumin: 3.2 $\pm$0.4 versus 3.6 $\pm$0.6 gm/dl, p < 0.05] by 6:00 AM on 1 day postoperatively, however there were no significant differences on 7 day postoperatively. The mean serum colloid osmotic pressure and osmolarity was similar in both group.There were no abnormal findings of liver function and kidney function in all the patients. There were no significant between-group differences in bleeding time, platelets, prothrombin time, activated partial thromboplastin time and amount of chest tube output measured on 1st and 7th postoperative day. These findings demonstrated that 10% pentastarch is more effective and safe for plasma volume expension than 5 % albumin solution with no adverse effects on coagulation. Also 10 % pentastarch is less expensive than 5 % albumin and it would appeare to be a reasonable first choice for plasma volume expansion.

  • PDF

Development and in Vivo Test of an Electrohydraulic Total Artificial Heart at the National Cardiovascular Center in Japan (일본 국립 순환기 센타형 전기유압식 인공심장의 개발과 동물실험)

  • 손영상
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.163-170
    • /
    • 1998
  • The ultimate goal of total artificial heart is permanent substitute for a failed heart in a patient without any other therapeutic modality. Until now, infection has been the main problem related to the mechanical circulatory support system. The best way to solve this catastrophic complication and to improve the quality of life of TAH patients in terms of tethering must be implantation of TAH totally. The EH-TAH has been developed in NCVC from 1987 for this purpose. The system consists of an energy converter and pumps, which are designed to be placed in abdomen and pericardial space separately for a good anatomical fit. To evaluate the anatomical fit and hemodynamic performance of the EH-TAH, in vivo test was done. General condition of the animal and hemodynamic status had been stable until the TAH stopped on the 11th pumping day. The estimated cardiac output was about 7.7L/min. The values of mean aortic pressure, left and right atrial pressure were 93$\pm$10, 19$\pm$3 and 15$\pm$4 mmHg, respectively. The correlation coefficient between left and right atrial pressure was 0.96, which represents the dynamic function of the interatrial shunt in controlling left-right imbalance of cardiac output. During pumping days, the temperature on the surface of actuator had been maintained at 39.7$\pm$0.4$^{\circ}C$, less than 1$^{\circ}C$ higher than the rectal temperature. The TAH stopped on the 11th day due to mechanical problems. We concluded that the EH-TAH possessed satisfactory basic performance including anatomic fit and hemodynamic adequacy, although there were several mechanical problems to be solved yet.

  • PDF

Intervention with Balloon Valvuloplasty followed by Patent Ductus Arteriosus Stent in a Patient with Pulmonary Atresia with Intact Ventricular Septum (풍선판막성형술과 동맥관 스텐트를 이용하여 치료한 심실중격결손을 동반하지 않은 폐동맥 폐쇄 1례)

  • Lim, Han Hyuk;Kim, Young Deuk;Lee, Jae Hwan;Chang, Mea Young;Kil, Hong Ryang
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.11
    • /
    • pp.1256-1256
    • /
    • 2005
  • Pulmonary atresia with intact ventricular septum (PAIVS) is rare, less than 1% of congenital heart disease. It needs a therapeutic approach according to its individual morphologic feature. Surgical treatment of valvotomy and modified Blalock-Taussig shunt or non-surgical interventional catheter balloon valvuloplasty can be used for mild to moderate hypoplasia of right ventricle. Fontan operation can be considered for less optimum morphological substrate of two ventricular repair. A 3-day-old male neonate was admitted with cyanosis and cardiac murmur. On echocardiogram, he had membranous pulmonary atresia with intact ventricular septum, normal sized tripartite right ventricle, large atrial septal defect with right-to-left shunt, small sized patent ductus arteriosus, and moderate tricuspid regurgitation. He was treated with intravenous continuous infusion of prostaglandin $E_1$ ($PGE_1$) at once. On the third day of hospitalization, Balloon valvuloplasty was performed. After insertion of patent ductus arteriosus stent on the tenth day, $PGE_1$ infusion was discontinued. On the fifteenth day, he was discharged. Now, he is 9 months old and has nearly normal cardiac structure and function with 97% of percutaneous oxygen saturation.

Early Results of Extracardiac Fontan Operation (심장외폰탄수술의 조기성적)

  • 김웅한;정도현;김수철;전홍주;이창하;김욱성;오삼세;정철현;나찬영
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.650-659
    • /
    • 1998
  • Between August 1996 and August 1997, 22 patients underwent extracardiac Fontan operations. The basic diagnoses included univentricular heart of the right ventricular type (n=12); univentricular heart of the left ventricular type (n=4); tricuspid atresia (n=4); left isomerism, transposition of great arteries, ventricular septal defect and pulmonary stenosis (n=1); and criss-cross heart with uneven ventricle (n=1). The median age of the 14 men and 8 women was 29 months (range from 21 months to 26 years). Previous procedures included bidirectional cavopulmonary shunt (n=15, interval=15.6$\pm$3.4 months), Kawashima operation (n=4, interval=37.5$\pm$20 months), and classic Glenn shunt (n=1, interval=14 years). In 2 patients, extracardiac Fontan operations were done without any previous procedures. A 16- to 22-mm flexible Gore-Tex tube graft (n=18), Hemashield graft (n=3), or, alternatively, a nonvalved aortic allograft (n=1) was cut and anastomosed end-to-end between inferior vena cava and undersurface of pulmonary artery using Gore-Tex or Prolene suture in a running fashion. In risk Fontan patients (n=12), a communication between the extracardiac conduit and the right atrium was constructed. In the most 13 recent patients, the procedures were done without cross-clamping of the aorta and with a beating heart. Operative mortality was 9.1% (n=2). Complications included persistent chest tube drainage for more than 7 days (n=5), chorea (n=2), and low cardiac output (n=1). There were no late deaths. Follow-up echocardiogram (mean: 6 months) demonstrated satisfactory hemodynamic results in the surviving 20 patients. Potential advantages of this technique consist of minimization of surgical manipulation of atrial tissue, reduction or elimination of myocardial ischemia, creationof a uniform and stable inferior vena cava-to-pulmonary artery conduit, and increased flexibility and safety in certain high-risk patients such as those with increased pulmonary vascular resistance, pulmonary hypertension, and impaired ventricular function. Further investigations during a longer follow-up are needed to confirm the intermediate and long-term results, especially the reduction of late atrial arrhythmias.

  • PDF

Patent Foramen Ovale Complicated with Chronic Mitral Valvular Insufficiency in A Mixed Dog (잡종 개에서 이첨판 폐쇄 부전증이 합병된 난원공 개존증)

  • Lee, Dong-Guk;Han, Suk-Hee;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.468-472
    • /
    • 2013
  • A 12-year-old intact female mixed dog (weighing 6.2 kg) was referred with primary complaints of severe abdominal distension, persistent coughing and exercise intolerance. Diagnostic studies found ascites, jugular distension, loud left and right apical systolic (grade 4/6) murmur, generalized cardiomegaly with caudal vena cava distension and left atrial dilation. Echocardiographic findings were consistent with degenerative mitral and tricuspid valve endocardiosis and bi-ventricular congestive heart failure. There was also a left to right shunting patent foramen ovale. The LV systolic function is depressed relative to the degree of volume overload. Based on diagnostic findings, this case was diagnosed as PFO complicated with mitral and tricuspid valve endocardiosis with ISACHC IIIa heart failure. The dog was treated with furosemide (2 mg/kg, q12hr, PO), sildenafil (1 mg/kg, q8hr, PO), pimobendan (0.3 mg/kg, q12hr, PO), enalapril (0.5 mg/kg, q12hr, PO) and spironolactone (1 mg/kg, q12hr). The clinical signs were gradually improved after medical therapy.

Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart (MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF