• Title/Summary/Keyword: Atmospheric sampling

Search Result 417, Processing Time 0.023 seconds

Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area (대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

Thermal Distribution of Size-resolved Carbonaceous Aerosols and Water Soluble Organic Carbon in Emissions from Biomass Burning

  • Bae, Min-Suk;Park, Seung-Shik
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.95-104
    • /
    • 2013
  • The study of carbonaceous aerosols in the atmosphere is critical to understand the role of aerosols in human health and climate. Using standardized thermal optical transmittance methods, organic carbon (OC), elemental carbon (EC), and water soluble organic carbon (WSOC) were determined using a combustion sampling system for four types of agricultural crop residues (rice straw, red pepper stems, soybean stems, and green perilla stems) and eight types of forest trees (pine stems, pine needles, ginkgo stems, ginkgo leaves, maple stems, maple leaves, cherry stems, and cherry leaves). The aerosol particles between 0.056 and $5.6{\mu}m$ in size were analyzed using a Micro-Orifice Uniform Deposit Impactor (MOUDI). In the current study, the Carbonaceous Thermal Distribution (CTD) by carbon analyzer was discussed in order to understand the carbon fractions from the twelve types of biomass burning. Also, the concentration of OC, EC, WSOC, and water insoluble organic carbon (WIOC) detected in the emissions were described.

On the Sources of Acid Rain Observed in the West Coast of Korea (한국 서해안에서 관측된 산성비의 발원지 추적연구)

  • 정용승;김태군
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.203-207
    • /
    • 1991
  • Scientists in the National Institute of Environmental Research had carried out air and precipitation sampling. According to the data analysed, the acidity (pH) measured was in the range of 3.7 $\sim$ 5.5. Detailed analysis indicated that observed acid rain was associated with westerlies generally coming out of the mainland of China and with a cyclone formed therein. Emission of air pollution from Korea and Japan also appeared to contribute in the observed high acidity in some cases. The one of chief reasons for the occurrence of acid rain in the west coast of Korea was due to the increase in the total emission of air pollution in China. In 1990, China was the world's top producer of coal amounting in 1.05 B tons with an annual increase of 10%, and the produced 100 M tons of crude oil. $SO_2$ emission from all energy usage in China was estimated at 25 $\sim$ 50 M ton per year.

  • PDF

Characteristics of Anion Concentration Distributions in Airbone Fine Particles in Urban Atmosphere (도시대기 중에 부유하는 미세입자중 음이온의 농도분포 특성)

  • 천만영;조기철;여현구
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 1997
  • Anion concentrations and distributions of airborne fine particles less than 2 $\mu$m in urban atmosphere were determined from Feb. 5 to 16, 1996. The sampling was carried out using 8 stages Hering's low pressure impactor (LPI, aerodynamic cutoff diameters are 0.05, 0.075, 0.11, 0.26, 0.50, 1.0, 2.0, and 4.0$\mu$m) on the top of a five-story building located at Kon-Kuk university in Seoul. Average concentrations if C $l^{[-10]}$ , N $O_3$$^{[-10]}$ and S $O_4$$^{2-}$ were 9.4, 8.4, and 14.5 $\mu\textrm{g}$/㎥, respectively. The distributions of these anion concentrations were bimodal types which showed two peaks in the range of 0.075~0.12 ${\mu}{\textrm}{m}$ and 0.5~1 ${\mu}{\textrm}{m}$ in aerodynamic diameter. These results were 2.5~4.7 times higher than anion concentrations collected by Anderson low volume air sampler.

  • PDF

Effects of Air Pollution on Pinus thunbergii in Yocheon Industrial Comples (麗川工業 地의 大氣汚染이 곰솔에 미치는 影響)

  • 김태욱;이경재;김준선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.25-32
    • /
    • 1985
  • To examine the effects of air pollution on Pinus thunbergii growing around Yocheon Industrial Complex, evaluation of visible injury based on Injury Index and chemical analysis of water-soluble sulfur and fluorine contents in needles were carried out on 30 sampling sites. Histological responses of needles were also investigated on the necrotic needle tissues. Not only Injury Index but water-soluble sulfur and fluorine contents were higher at all sites than those at control site, and showed significant correlationship among them. Especially, they were rather higher in the vicinity of air pollutants sources. Water-soluble sulfur contents were positively correlated with average atomospheric $SO_3$ concentrations. Microscopic examination of necrotic needle tissues showed that mesophyll cells were collapsed with hypertrophy and collapse of transfusion cells.

  • PDF

Acidity Analysis of Precipitation Occurred at Woongchon, Choongnam (충남 웅천에서 관측된 강수의 산성도 연구)

  • 이근준;정용승
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.179-187
    • /
    • 1996
  • Sampling of precipitation occurred at Woongchon in Choongnam from the period between May 1994 and April 1995 was made, and analysis on the data was carried out on observed pH values of the precipitations. It was found that weighted mean pH values were .sim. 4.8 and that acid rain occurred at the site of the Yellow Sea's coastal area. The results agree well with the earlier observations made at other sites of a background monitoring network. The annual values observed at the background monitoring sites were too low in comparison with the mean pH values (5.3 .sim. 5.9) obtained from urban stations of the Ministry of Environment. It was observed that values of pH in rain water often changed with time during the event of precipitation, and the low values usually depended on an airflow and a cyclone that originated in the source region.

  • PDF

In-Vehicle Exposure to Volatile Organic Compounds (휘발성 유기물질에 대한 차량 탑승시 노출)

  • 조완근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.151-157
    • /
    • 1996
  • Vehicle occupant exposure to volatile organic compounds (VOCs) continues to be the subject of active research because of higher levels of VOCs in vehicles than in the surrounding ambient atmosphere and because of potential health risk. This study identified in-auto and in-bus exposures to 6 selected aromatic VOCs during rush-hour driving. A bus service route was selected to include an urban route (Taegu) and a suburban route (Hayang-Up) to satisfy the specified criteria of this study. The most abundant VOC concentration measured in this study was toluene. In-vehicle target Voc concentrations of the urban route were significantly different from those of the suburban segment. On the sum of average of the target VOCs, in-auto VOC concentration was about 1.5 times higher than in-bus VOC concentration. Based on the sum of average, in-automobile target VOC concentrations of this study were within the range of previous studies conducted in several cities of the United States, while in-bus VOC concentrations of this study were much lower than those of Taipei in Taiwan. In-vehicle VOC concentrations of present study significantly varied with sampling days, while they did not varied with driving period.

  • PDF

Source Identification of Fine Particle($PM_{2.5}$) in Chongju Using a Chemical Mass Balance Model (수용모델을 이용한 청주시 미세입자($PM_{2.5}$)의 기여도 추정)

  • 강병욱;이학성;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.5
    • /
    • pp.477-485
    • /
    • 2000
  • The data set was collected on fifty-eight different days with a 24-h sampling period from October 27, 1995 through August 25, 1996. From the chemical mass balance (CMB) analysis of $PM_{2.5}$ in the Chongju area, the contributions from soil, gasoline, diesel, light and heavy oil combustion were 2.6%, 15.4%, 9.0%, 28.8% and 1.5%, respectively. Residual $NO_{3}^{-}$), residual $SO_{4}^{2-}$ and residual OC, possibly formed in the atmosphere. represented additional 8.0, 10.2, and 1.6% of the $PM_{2.5}$, respectively. Other unidentified sources constituted the remaining 22.9%. From the CMB analysis, the $PM_{2.5}$ source contribution for fall, winter, spring and summer were 92, 76.8, 77.5 and 59.2%, respectively.

  • PDF

Elemental Analysis of Road Aerosols using by a PIXE Method (PIXE 분석법에 의한 도로변 분진의 원소분석)

  • 최금찬;임경택;조정구;김태형
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.5
    • /
    • pp.523-528
    • /
    • 1996
  • Aerosol Particles were collected in a heaby traffic region in pusan. Samples were collected in two size fractions with a two-stage sampler during the day and the night. Elemental concentrations of these aerosol particles were determined by a PIXE(Proton Induced X-ray Emission) analysis method. The results suggest that the elements originating mainly from natural sources such as Si, Ca, Fe, Cl, and K are dominent in the coarse fraction, but the elements such as S, Pb, Br, and Zn are dominent in the fine fraction. Br/Pb ratio are evaluated in both coarse and fine size fraction, and which are mainly emitted automobile sources. The study further also discussed other Br/Pb ratio related works described elsewhere. Sulfur in the fine fraction was continuously increased during the sampling period without time variation.

  • PDF

Ionic Composition of Early and Succeeding Rainwater in Pusan Area (부산시 일부지역에 대한 초기 및 후속강우의 이온성분 특성)

  • 최금찬;김찬환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.361-368
    • /
    • 1998
  • Acid rainwater samples were collected during 4 years from 1992 in Pusan area nearby seaside. Ionic composition of early and succeeding rainwater were investigated to identify emission sources. pH and Electronic Conductivity of samples were measured immediately after sampling. Major ion concentrations of rain samples were Na+, Ca2+, Mg2+, K+, NH4+, SO42-, NO3-, Cl- which were analyzed by ion Chromatography. 55% of early rainwater and 90% of succeeding rainwater were identified below pH 5.6. Because, Na+, K+, Ca2+ were washed mostly in early rainwater, as a result, pH values were increased by increasing rainfall amounts. It was studied that pH value was varied from ambient ion component, rainfall, and rain intensity. From the principal component analysis result, the dominant components of acid rainwater were Na+, K2+, Mg2+, Ca2+, the elements were contributed soil and marine source, the second components nuts -SO42-, SO4a-, NO3-, nuts -Ca2+ originated from man - made source.

  • PDF