• 제목/요약/키워드: Atmospheric deposition

검색결과 459건 처리시간 0.02초

한국에서 분진 및 금속원소의 건식 침착속도 추정에 관한 연구 (Studies on Estimating Dry Deposition Velocities for Atmospheric Aerosol and Metal Elements in Korea)

  • 김성천;김동술
    • 한국대기환경학회지
    • /
    • 제12권1호
    • /
    • pp.101-112
    • /
    • 1996
  • Dry and wet deposition is an impertant removal mechanism of the amobient aerosol in the atmospheric environment. Since the deposition flut provides adverse impacts on various encironmental media including aquatic and ecological system as well as human health, it is essential to quantitatively estimate the removal fluxes of many air pollutants. Thus, the purposes of this experimental study are to investigate seasonal deposition flux variations of the total dustfall and various inorganic elements in the local ambient air and then to finally estimate their dry deposition velocities. To perform the study, the total of 90 dustfall samples were collected from January, 1994 thru February, 1995 in 5 different cities of Korea including Seoul, Suwon, Daejon, Kwangju, and Kangrung. Each sample was analyzed by an AAS and an ICP to determine the quantities of the 11 inorganic elements, such as Zn, Cd, Cr, K, Na, Pb, Ca, Fe, Mn, Mi, and Cu. As results, deposition fluxes, soluble/insoluble fractions, and deposition velocities for each element were extensively investigated. The resulting dry deposition velocities of some elements in Suwon were estimated by ranges of 0.57 .sim. 0.87 cm/sec for Zn, 0.35 .sim. 0.45 cm/sec for Pb, 1.25 .sim. 3.52 cm/sec for Ca, 0.21 .sim. 0.48 cm/sec for Fe, 0.95 .sim. 9.31 cm/sec for Mn, and 2.08 cm/sec for Cu.

  • PDF

새로운 건성 및 습성 침착 채취기의 개발 (Development of the Novel Dry and Wet Deposition Collector)

  • 이병규;이채복
    • 한국대기환경학회지
    • /
    • 제16권6호
    • /
    • pp.675-684
    • /
    • 2000
  • A novel dry and wet deposition collector, which can overcome the several problems such as water evaporation cartridge cracks and high costs founded in the previous collector systems, has been constructed. ENVI-18 SPE adsorption cartridge has been used to measure atmospheric deposition of polycylic aromatic hydrocarbons (PAHs). A surrogate surface, consisted of water and methanol, was filled in the dry deposition funnel to simulate dry deposition onto water surface. A water supply system in order to compensat evaporation of the surrogate surface was used and it was consisted of a piston pump, a tubing pump, a overflow tube and a chamber system. A novel water vaporizing system to supply water onto the wet SPE cartridge system with a constant flow rate was developed. The novel water vaporizing system, consisted of a vacuum pump, a water supply reserviour and tube and a mini space heater, could prevent the PAHs adsorption cartridge cracks occurred in the previous collector and effectively adsorb PAHs. The novel dry and wet deposition collector showed a good adsorption, desorption, and recovery rates of PAHs. By reducing the number of pumps used and employing polypyopylene (PP) instead of teflon as a material of collection funnel, the total construction costs were much reduced as compared with the previous dry and wet deposition collectors.

  • PDF

전주지역에서 다환방향족 탄화수소의 건식 침적 측정 (Measurement of Dry Deposition of Polycyclic Aromatic Hydrocarbons in Jeoniu)

  • 김형섭;김종국;김영성
    • 한국대기환경학회지
    • /
    • 제23권2호
    • /
    • pp.242-249
    • /
    • 2007
  • Deposition fluxes of polycyclic aromatic hydrocarbons (PAHs) were measured at the Chonbuk National University located in Jeonju between June and November 2002. Fluxes of gaseous and particulate PAHs were separately obtained using a water surface sampler (WSS) and a dry deposition plate (DDP). Most of PAHs were deposited in the gaseous form since the low molecular weight PAHs dominates in the atmosphere. The deposition velocity of particulate PAHs was higher than that of gaseous PAHs when the molecular weight was low, but substantially decreased as the fine particle fraction increased with molecular weight. The deposition velocity was generally higher at high wind speeds. However, increase in the deposition velocity in unstable atmospheric conditions was also observed for gaseous PAHs of intermediate molecular weight.

도심 지역의 다이옥신류 폴리염화비페닐류의 침적 플럭스 (Deposition flux of dioxin-like polychlorinated biphenyls(DLPCBs) in urban environment of Busan)

  • 문효방;이수정;최희구;옥곤
    • 한국환경과학회지
    • /
    • 제13권5호
    • /
    • pp.469-478
    • /
    • 2004
  • Atmospheric bulk (wet and dry) samples were monthly collected in an urban environment (Daeyeon-dong) of Busan over a year, to assess the deposition flux and seasonality of dioxin-like polychlorinated biphenyls (DLPCBs) using stainless steel pots. Deposition fluxes of DLPCBs in bulk samples were determined using high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC/HRMS). Particle deposition fluxes in the urban environment varied from 23 to 98 $mg^2$/year (mean 41 $gm^2$/year). DLPCB deposition fluxes in atmospheric bulk samples ranged from 0.09 to 0.77 ng-$TEQ/m^2$/year (mean 0.35 ng-$TEQ/m^2$/year). Seasonal atmospheric deposition fluxes of DLPCBs were high in winter and low in summer. Atmospheric deposition fluxes of particles and DLPCBs in this study were comparable to or slightly lower values than those of different locations in the world. Monthly DLPCB profiles in deposition bulk samples were similar over a year. Non-ortho PCBs were higher contributions to the total DLPCBs fluxes than mono-ortho PCBs. In particular, PCB 126 had the highest concentrartion (>75%) in all deposition samples, followed by PCB 169 and PCB 156. A highly positive correlation was found among the deposition fluxes of DLPCB species, suggesting the possibility of that the DLPCB contamination originated from one source. The deposition fluxes of DLPCBs were not significantly correlated with temperature and the amount of precipitation even though the summer season with the highest temperature and the largest amount of precipitation showed the lowest DLPCB deposition flux.

제주지역 강하 먼지의 조성에 관하여 - 1. 화학적 조성 및 침적량 (A Study on Chemical Composition of Dustfall Samples in Cheju Area - 1. Chemical composition and deposition)

  • 이기호;허철구;송문호;박용이
    • 한국대기환경학회지
    • /
    • 제15권1호
    • /
    • pp.13-22
    • /
    • 1999
  • This study is carried out to investigate the chemical composition of atmospheric deposition in Cheju Island, Korea. For this purpose, dustfall matter samples are collected by dust jar from August, 1995 to July, 1996 at five sampling sites and total suspended particulate matters (TSP) and rain are also collected at one site from October, 1995 to July, 1996. All the samples collected are analyzed, and then the information of the 19 chemical species and deposition amount of each species is obtained. These data are used to determine the regional trends in dustfall chemistry and deposition, and compare the characteristics of chemical compositions between dustfall, TSP and rainwater.

  • PDF

필터팩을 이용한 서울과 춘천, 안면도의 건성 강하량 측정 (Measurement of Dry deposition at Seoul, Chunchon and Anmyon-do by Using Filter pack Method)

  • 김만구;강미희;홍영민;박기준;이보경;이동수;김산
    • 한국대기환경학회지
    • /
    • 제17권1호
    • /
    • pp.19-29
    • /
    • 2001
  • Atmospheric concentrations of acidic pollutant were measured by the 4 stage filter pak method at Chunchon and by the 3 stage filter pack method at Seoul and Anmyon-do from January to December 1998. The sample was collected for 24 hours on every Wednesday. Concentrations of particulate matters were highest at Anmyon-do. The particulate concentration was much higher during the warm season than other seasons. While the particulate concentration was higher during the warm season, the concentration of gaseous matter was higher in winter. Dry deposition flux was calculated by using reported deposition velocities and concentration of pollutants measured in this study. The dry deposition velocities used in this study for SO$_2$, SO$_{4}^{2}$, HNO$_3$,NO$_{3}^{-}$ and NH$_3$ were 0.29, 0.15, 2.08( 2.13 only for Anmyon-do), 0.20 and 1.00cm/sec, respectively. At Chunchon, annual sulfur flux originated from dry deposition was 384 kg/$textrm{km}^2$, and the flux from wet deposition was 782kg/$textrm{km}^2$. Dry deposition of sulfur was 33% of total sulfur deposition. The annual nitrogen flux originated from dry deposition was 1,892kg/$textrm{km}^2$. And the flux from wet deposition was 1,066kg/$textrm{km}^2$. Dry deposition of nitrogen was 64% of total nitrogen deposition. Dry deposition as well as wet deposition have to be considerd in the study on acidification of environment such as soil or watershed.

  • PDF

지표면의 종류에 따른 오존의 건성침적속도에 관한 수치모의 (Numerical Simulation for Dry Deposition Velocity of Ozone According to Land-use Types)

  • 이화운;노순아;문난경
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.583-594
    • /
    • 2003
  • Ozone is an important atmospheric pollutant that is occurred in tropospheric chemical process and it also affects the human health and plants. For a correct application of abatement strategies for ozone, it is necessary to understand the factors that control atmospheric ozone removal by dry deposition processes. The present study investigates the numerical simulation of the dry deposition velocity (V$^{d}$ ) obtained from PNU/DEM (Pusan National University Deposition Model). PNU/DEM includes seasonal categories, meteorological factors, surface properties and land-use types and proposes for an accurate numerical computation. And, this study examines the ability of the PNU/DEM to compute V$_{d}$ of ozone over water surfaces and evaluates PNU/DEM by comparing its estimated V$_{d}$ to past observed V$_{d}$ over water. The parametrization was found to yield V$_{d}$ values generally in good agreement with the observations for the deciduous forest and the coniferous forest. Ozone is removed slowly at wet surface or water due to its low water solubility. Therefore V$_{d}$ values over water were lower than Vd values over the other surfaces. Comparison of PNU/DEM simulated V d values to observations of ozone V$_{d}$ that have been reported in the literature implies that PNU/DEM produces realistic results.

다공성 금속 샤워헤드가 적용된 상압플라즈마 화학기상증착법을 이용한 저온 다결정 실리콘 증착 공정 (Low Temperature Polycrystalline Silicon Deposition by Atmospheric Pressure Plasma Enhanced CVD Using Metal Foam Showerhead)

  • 박형규;송창훈;오훈정;백승재
    • 한국전기전자재료학회논문지
    • /
    • 제33권5호
    • /
    • pp.344-349
    • /
    • 2020
  • Modern thin film deposition processes require high deposition rates, low costs, and high-quality films. Atmospheric pressure plasma-enhanced chemical vapor deposition (AP-PECVD) meets these requirements. AP-PECVD causes little damage on thin film deposition surfaces compared to conventional PECVD. Moreover, a higher deposition rate is expected due to the surface heating effect of atomic hydrogens in AP-PECVD. In this study, polycrystalline silicon thin film was deposited at a low temperature of 100℃ and then AP-PECVD experiments were performed with various plasma powers and hydrogen gas flow rates. A deposition rate of 15.2 nm/s was obtained at the VHF power of 400 W. In addition, a metal foam showerhead was employed for uniform gas supply, which provided a significant improvement in the thickness uniformity.

초음파 풍속온도계를 이용한 $SO_2$건성침착속도의 계절변화 특징 (Seasonal Variations of $SO_2$Dry Deposition Velocity Obtained by Sonic Anemometer-Thermometer)

  • 이종범;박세영
    • 한국대기환경학회지
    • /
    • 제14권5호
    • /
    • pp.465-478
    • /
    • 1998
  • In this study, seasonal variations of the dry deposition velocity and deposition flux for the sulfur dioxide were analysed. The field observation was performed during one year (from November 1, 1995 to October 31, 1996) in Chunchon basin. The turbulence data were measured by 3-dimensional sonic anemometer/thermometer, and were estimated by mean meteorological data obtained at two heights (2.5 m and 10 m) of meteorological tower. Also, the estimation methods were evaluated by comparing the turbulence data. The results showed that the estimated dry deposition velocity and turbulence parameter such as uc and sensible heat flux using mean meteorological data were relatively similar to the sonic measurements, but all showed somewhat large differences. The dry deposition velocity was large in summer and small in winter mainly due to canopy resistance (rc). The major factor which affects diurnal variation of the velocity was aerodynamic resistance (rw). The SO2 dry deposition flux was large in winter and small in summer in Chunchon.

  • PDF

대기오염 입자의 인체 호흡기내 비대칭 국부침전 특성에 관한 연구 (Study on the Asymmetric Regional Deposition of Airborne Pollutant Particles in the Human Respiratory Tract)

  • 구재학;김종숭
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.551-560
    • /
    • 2003
  • Particle deposition in human lungs was investigated theoretically by using asymmetric five-lobe lung model. The volumes of each of the five lobes were different, thereby forming an asymmetric lung structure. The tidal volume and flow rate of each lobe were scaled according to lobar volume. The total and regional deposition with various breathing patterns were calculated by means of tracking volume segments and accounting for particle loss during inhalation and exhalation. The deposition fractions were obtained for each airway generation and lung lobe, and dominant deposition mechanisms were investigated for different size particles. Results show that the tidal volume and flow rate have a characteristic influence on particle deposition. The total deposition fraction increases with an increase in tidal volume for all particle sizes. However, flow rate has dichotomous effects: a higher flow rate results in a sharp increase in deposition for large size particles, but decreases deposition for small size particles. Deposition distribution within the lung shifts proximally with higher flow rate whereas deposition peak shifts to the deeper lung region with larger tidal volume. Deposition fraction in each lobe was proportional to its volume. Among the three main deposition mechanisms, diffusion was dominant for particles < 0.5 ${\mu}{\textrm}{m}$ whereas sedimentation and impaction were most influential for larger size particles. Impaction was particularly dominant for particles> 8 ${\mu}{\textrm}{m}$. The results may prove to be useful for estimating deposition dose of inhaled pollutant particles at various breathing conditions.