A New Photovoltaic System Architecture of Module-Integrated Converter with a Single-sourced Asymmetric Multilevel Inverter Using a Cost-effective Single-ended Pre-regulator

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.222-231
    • /
    • 2017
  • In this paper, a new architecture for a cost-effective power conditioning systems (PCS) using a single-sourced asymmetric cascaded H-bridge multilevel inverter (MLI) for photovoltaic (PV) applications is proposed. The asymmetric MLI topology has a reduced number of parts compared to the symmetrical type for the same number of voltage level. However, the modulation index threshold related to the drop in the number of levels of the inverter output is higher than that of the symmetrical MLI. This problem results in a modulation index limitation which is relatively higher than that of the symmetrical MLI. Hence, an extra voltage pre-regulator becomes a necessary component in the PCS under a wide operating bias variation. In addition to pre-stage voltage regulation for the constant MLI dc-links, another auxiliary pre-regulator should provide isolation and voltage balance among the multiple H-bridge cells in the asymmetrical MLI as well as the symmetrical ones. The proposed PCS uses a single-ended DC-DC converter topology with a coupled inductor and charge-pump circuit to satisfy all of the aforementioned requirements. Since the proposed integrated-type voltage pre-regulator circuit uses only a single MOSFET switch and a single magnetic component, the size and cost of the PCS is an optimal trade-off. In addition, the voltage balance between the separate H-bridge cells is automatically maintained by the number of turns in the coupled inductor transformer regardless of the duty cycle, which eliminates the need for an extra voltage regulator for the auxiliary H-bridge in MLIs. The voltage balance is also maintained under the discontinuous conduction mode (DCM). Thus, the PCS is also operational during light load conditions. The proposed architecture can apply the module-integrated converter (MIC) concept to perform distributed MPPT. The proposed architecture is analyzed and verified for a 7-level asymmetric MLI, using simulation results and a hardware implementation.

BINARY RANDOM POWER APPROACH TO MODELING ASYMMETRIC CONDITIONAL HETEROSCEDASTICITY

  • KIM S.;HWANG S.Y.
    • Journal of the Korean Statistical Society
    • /
    • v.34 no.1
    • /
    • pp.61-71
    • /
    • 2005
  • A class of asymmetric ARCH processes is proposed via binary random power transformations. This class accommodates traditional nonlinear models such as threshold ARCH (Rabemanjara and Zacoian (1993)) and Box-Cox type ARCH models(Higgins and Bera (1992)). Stationarity condition of the model is addressed. Iterative least squares(ILS) and pseudo maximum like-lihood(PML) methods are discussed for estimating parameters and related algorithms are presented. Illustrative analysis for Korea Stock Prices Index (KOSPI) data is conducted.

Assessment of pushover-based method to a building with bidirectional setback

  • Fujii, Kenji
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.421-443
    • /
    • 2016
  • When conducting seismic assessment of an asymmetric building, it is essential to carry out three-dimensional analysis considering all the possible directions of seismic input. For this purpose, the author proposed a simplified procedure is to predict the largest peak seismic response of an asymmetric building subjected to horizontal bidirectional ground motion acting in an arbitrary angle of incidence in previous study. This simplified procedure has been applied to torsionally stiff (TS) asymmetric buildings with regular elevation. However, the suitability of this procedure to estimate the peak response of an asymmetric building with vertical irregularity, such as an asymmetric building with setback, has not been assessed. In this article, the pushover-based simplified procedure is applied to estimate the peak response of asymmetric buildings with bidirectional setback. Nonlinear dynamic (time-history) analysis of two six-storey asymmetric buildings with bidirectional setback and designed according to strong-column weak beam concept is carried out considering various directions of seismic input, and the results compared with those estimated by the proposed method. The largest peak displacement estimated by the simplified method agrees well with the envelope of the dynamic analysis response. The suitability assessment of the simplified procedure to analysed building models is made as well based on pushover analysis results.

Parameters affecting the seismic response of buildings under bi-directional excitation

  • Fontara, Ioanna-Kleoniki M.;Kostinakis, Konstantinos G.;Manoukas, Grigorios E.;Athanatopoulou, Asimina M.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.5
    • /
    • pp.957-979
    • /
    • 2015
  • The present paper investigates the influence of the orientation of the ground-motion reference axes, the seismic incident angle and the seismic intensity level on the inelastic response of asymmetric reinforced concrete buildings. A single storey asymmetric building is analyzed by nonlinear dynamic analyses under twenty bi-directional ground motions. The analyses are performed for many angles of incidence and four seismic intensity levels. Moreover three different pairs of the horizontal accelerograms corresponding to the input seismic motion are considered: a) the recorded accelerograms, b) the corresponding uncorrelated accelerograms, and c) the completely correlated accelerograms. The nonlinear response is evaluated by the overall structural damage index. The results of this study demonstrate that the inelastic seismic response depends on the orientation of the ground-motion reference axes, since the three individual pairs of accelerograms corresponding to the same ground motion (recorded, uncorrelated and completely correlated) can cause different structural damage level for the same incident angle. Furthermore, the use of the recorded accelerograms as seismic input does not always lead to the critical case of study. It is also shown that there is not a particular seismic incident angle or range of angles that leads to the maximum values of damage index regardless of the seismic intensity level or the ground-motion reference axes.

The Analysis of Low Back Loading and Muscle Fatigue while Lifting an Asymmetric Load (비대칭무게중심을 지닌 물체 들기 작업시 허리부위 등근육 부하 및 피로 분석)

  • Han, Seung-Jo;Kim, Sun-Uk
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.30-36
    • /
    • 2012
  • This study is aimed to show that an asymmetric load in the frontal plane leads to an increase in low back loading and fatigue in comparison with a symmetric load when workers lift an external weight by investigating previous studies and verifying the phenomenon with an experiment. Ten male subjects are required to lift and hold an given external load at 70cm height during 50sec, then the EMG amplitude and median frequency on bilateral low back muscle groups (Longissimus, Iliocostalis, and Multifidus) are recorded and analyzed. Independent variables are two-level load weight (13kg, 20kg) and three-level LCG (Center, 6.5cm to the right, and 13cm to the right), and dependent variables are EMG amplitude average, difference, and Fatigue Index (FI). Results show that load weight increases significantly amplitude average and FI, but LCG does significantly amplitude difference and FI significantly (P-value < 0.05). Also the correlation coefficient between amplitude difference and FI is over 0.99. These implies that trunk loading should be explained by not EMG amplitude but muscle fatigue aspect since the association between an external load and amplitude is linear, but the relationship between an external load and median frequency as muscle fatigue index is almost exponential.

Analysis of the Gait Characteristics and Interaction among Bilateral Lower Extremity Joints According to Shoe'S Heel Heights in Young Women (젊은 성인 여성의 구두 힐 높이 별 보행특성 및 하지관절 간 상호작용 비교분석)

  • Hyun, Seung-Hyun;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.445-453
    • /
    • 2014
  • The purpose of this study was to analyze the gait characteristics and interaction between lower extremity joints according to shoe's heel heights in young women. Participants were selected as subject consisted of young and healthy women (age: $23.71{\pm}1.49yrs$, height: $165.92{\pm}2.00cm$, body weight: $54.37{\pm}3.46kg$) and walked with 3 types of shoe's high-heel (0, 5, 9 cm). The variables analyzed consisted of the displacement of Y axis in center of mass ([COM]; (position, velocity), front rear(FR) and left right(LR) angle of trunk, lower extremity joint angle (hip, knee, ankle) and asymmetric index (AI%). The displacement of Y axis in COM position showed the greater movement according to increase of shoe's heel heights, but velocity of COM showed the decrease according to increase of shoe's heel heights during gait. The hip and knee angle didn't show significant difference statistically according to increase of shoe's heel height, but left hip and knee showed more extended posture than those of right hip and knee angle. Also ankle angle didn't show significant difference statistically, but 9 cm heel showed more plantarflexion than those of 5 cm and 0 cm. The asymmetric index (AI%) showed more asymmetric 9 cm heel than those of 0 cm and 5 cm. The FR and LR angle in trunk tilting didn't show significant difference statistically according to the increase of shoe's heel height during gait in young women.

A Study on the Design of a Floodlighting Tower with LED Source of Light Considering the Reduction of a Glare (눈부심 저감을 고려한 LED광원 계류장 조명탑 설계에 관한 연구)

  • Kim, Dong-Su;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.271-275
    • /
    • 2015
  • The floodlighting assists the pilot in taxiing the aircraft into and out of the final parking position and provide lighting suitable for passenger to embark and debark and for personnel to load and unload cargo. It is composed of sodium lamps which is consuming high energy. It needs to develop a dedicated LED lamp to replace the existing lamps. In this paper, We propose a suitable asymmetric angle of LED lamps to avoid a pilot's glare and to meet the standard illumination. For this, we analyze asymmetric angle of sodium lamps which are using in airport and confirm whether the illumination distribution and glare index meet the relating standards by using simulation method. Also, we study the needs of asymmetric characteristics of LED ramp by simulating the LED lamps with and without asymmetric characteristics of ramp respectively. With the simulation result, finally we propose the best asymmetric angle of LED lamp to meet the average illumination standard, and avoid a pilot's glare.

Asymmetric Impacts of Oil Price Uncertainty on Industrial Stock Market -A Quantile Regression Approach - (분위수회귀분석을 이용한 유가 변동성에 대한 산업별 주식시장의 이질적 반응 분석)

  • Joo, Young-Chan;Park, Sung-Yong
    • Management & Information Systems Review
    • /
    • v.38 no.3
    • /
    • pp.1-19
    • /
    • 2019
  • This paper investigates the asymmetric effects of crude oil price uncertainty on industrial stock returns under different market conditions (bearish and bullish stock markets). We consider a quantile regression method using monthly oil volatility index, KOSPI and 22 industrial stock indices from May 2007 to February 2019. Especially, we take care of the positive and negative changes of the oil volatility index to analyze asymmetric effects of the oil price uncertainty for the bearish and bullish stock market conditions. During the bearish markets, the oil volatility index has relatively strong statistically significant negative effects on the industrial stock returns. These effects gradually decrease when the market conditions became more bullish markets. In particular, positive changes in the oil volatility index yields a further significant decrease in 12 industrial stock returns during the extreme bearish markets. Moreover, during the bullish markets, negative changes in the oil volatility index have statistically significant negative effects on the 12 industrial stock returns. From the empirical results, we see that participants of the Korean stock market are sensitive to bad news in a recession.

The Impacts of Muscle Energy Technique (MET) and Transcutaneous Electrical Nerve Stimulation (TENS) Performed on Elector Spinae Muscle of Acute Low Back Pain Patients on Pain and Meridian Electromyography (경근추나요법과 경피전기자극치료가 급성 요통 환자의 통증 및 척추기립근 경근전도에 미치는 영향)

  • Kim, Soon-Joong;Park, Dong-Su;Jeong, Su-Hyeon;Ahn, Jae-Min
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.1
    • /
    • pp.83-92
    • /
    • 2014
  • Objectives To evaluate the clinical usefulness between muscle energy techniques (MET) and transcutaneous electrical nerve stimulator (TENS), we performed both on elector spinae muscle of acute low back pain patients. Methods After performing MET and TENS, we compared both in terms of electrical activity. We performed MET or TENS on elector spinae muscle of acute low back pain patients in each group (n=15,15). After performing MET or TENS, we analyzed root mean square (RMS), median edge frequency (MEF) and asymmetry index (AI). Results 1. After performing MET on elector spinae muscle of acute low back pain patients, RMS was significantly decreased compared with before (p<0.005). 2. After performing TENS on elector spinae muscle of acute low back pain patients, RMS was significantly decreased compared with before (p<0.005). 3. After performing MET on elector spinae muscle of acute low back pain patients, asymmetric index was significantly decreased compared with before (p<0.05). Conclusions According to above results, performing MET on elector spinae muscle of acute low back pain patients has effect in terms of RMS and asymmetric index. And performing TENS on elector spinae muscle of acute low back pain patients also has similar effect in terms of RMS but has not in terms of asymmetric index.

THE CONVERGENCE RATES IN THE ASYMMETRIC LAWS OF LARGE NUMBER FOR NEGATIVELY ASSOCIATED RANDOM FIELDS

  • Ko, Mi-Hwa
    • Honam Mathematical Journal
    • /
    • v.34 no.2
    • /
    • pp.209-217
    • /
    • 2012
  • Convergence rates in the law of large numbers for i.i.d. random variables have been generalized by Gut[Gut, A., 1978. Marc inkiewicz laws and convergence rates in the law of large numbers for random variables with multidimensional indices, Ann. Probab. 6, 469-482] to random fields with all indices having the same power in the normalization. In this paper we generalize these convergence rates to the identically distributed and negatively associated random fields with different indices having different power in the normalization.