Change of Binocular Vision Induced by Longitudinal Chromatic Aberration during Near Work (근거리 작업 시 종색수차에 따른 양안시의 변화)

  • Kim, Se-il;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.219-228
    • /
    • 2015
  • Purpose: The current study was performed to compare the difference in binocular visual function depending on variable background colors at near work. Method: Fifty four adults (18 males, 34 females) who consented to the present study and had no ocular disease, ocular surgery history, strabismus and amblyopia with normal binocular vision were participated into this study. The subjects were asked to read the novels with black letter printed on white, red, green and blue background for 15 min. Then, their heterophoria, AC/A ratio, near point of convergence, accommodation facility, relative accommodation and vergence were measured before and after reading. The difference of measurements were compared. Result: Overall heterophoria was tended to decrease with regardless of background color. AC/A ratio showed a tendency of increase after reading the novels with all backgrounds except white background. Near point of convergence was significantly increased compared to before reading at all background color. Accommodative facility of dominant and non-dominant eyes were also significantly increased after reading however, binocular accommodative facility showed a tendency of decrease. Negative relative accommodation also decreased at all background colors however, the change of positive relative accommodation was not significantly different. In case of vergence, there was significant difference in break point of far BO and recovery point of far BI by the wavelength of background color. Conclusions: From the results, it was known there is convergence change depending on the wavelength of light even though same amount of accommodation and convergence is required when doing near work for certain period. Thus, it can be suggested that the adjustment of the near working environment which perception of various color was required, should be conducted according to the main wavelength.

The Study on the Property of The Heterophoria and Fusional Reserve in Adults in Jeon-buk Area (전북지역 성인의 사위와 융합여력 특성에 관한 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Sim, Sang-Hyun;Choi, Sun Mi;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.661-666
    • /
    • 2013
  • The aim of this study was to evaluate the property of heterophoria and fusional reserve in Adults in Jeon-buk Area. We examined the corrected visual acuity, corrected refractive error, heterophoria and fusional reserve of 116 healthy myopes aged from 20 to 44 old who had no strabismus no ocular and phyisical diseases. Using Von Graefe test of horizontal heterophoria Measurement, we measured orthophoria(26.7%), exophoria(52.5%) and esophoria(20.7%) for at near distance. The subjects who had exophoria of 0-6${\Delta}$ in the range of normal state was 38.8%, while the subjects who had exophoria in the range of abnormal state was 61.2%. Reducing fusional reserve was associated with increasing phoria. We found a relationship between asthenopia and fusional reserve of heterophoria and considered that fusional reserve must be examined when we preserve for a patient with heterophoria. Furthermore, Gradient method AC/A ratio was found 4.03 and its relationship to refractive error could not be determined.

The Change of the Phoria in Accordance with the Color and Concentration of the Color Lens (착색렌즈의 색상과 농도에 따른 원거리 사위도의 변화)

  • Choi, Hyun-Soo;Park, Sung-Jong;Lee, Seok-Ju;Jin, Moon-Seok;Jun, Jin;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.339-343
    • /
    • 2011
  • Purpose: In this study, we investigated changes of phoria based on varying the color and concentration of the color in lenses. Methods: We measured distance phoria for 39 students who aged 20 to 40 with different concentrated lenes - red, gray, brown and green lenses in concentration 20%, 50% and 80%, respectively. Results: Subjects were divided into three groups which were orthophoria, esophoria and exophoria. Orthophoria in all the color and concentration, there were a few of the esophoria. Esophoria of average 2.07${\Delta}$,B.O showed that a slight increase in all colors and concentration, especially in brown lenses showed the greatest increase. Exophoria of average 3.82${\Delta}$,B.I showed that a slight decrease in all colors and concentration, especially in green lenses showed to 2.95${\Delta}$,B.I to the greatest decrease. Different concentration in same color had no specific tendency regarding phoria. Conclusions: The phoria must be considered when selecting color of the lens because of phoria is changeable by color of the lens. It is expected to study the criteria that minimize the asthenopia.

A Study on the Accommodative Astigmatism of Near Vision (근거리 주시 시 조절성 난시에 대한 연구)

  • Lee, Hark-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.327-331
    • /
    • 2011
  • Purpose: The purpose of this study was an accurate grasp of the astigmatic change due to eyes accommodation on near vision and suggested problems occurring accommodative astigmatism using near glasses. Methods: 154 subjects(308eyes) from 20 to 40 years selected for this study who had many opportunity of near vision. First, far vision corrective refraction measured using the phoropter, and then both eyes opened simultaneously for maintaining the function of binocular put away dot chart 40 cm. One eye was fogging and the other eye measured near vision astigmatism axis and degrees astigmatism using cross cylinder, and then compared with far astigmatism. Results: Increased degree of astigmatism persons on near vision more than decreased or did not changed degree of astigmatism persons, which could affect visual acuity more than 0.75 diopters in 30 eyes with an increase of 9.7% of total subjects. Direct astigmatism and oblique astigmatism were increased on near vision. Astigmatic axes were rotated base in direction on both eyes and 66.9% of subjects were more than ${\pm}$5$^{\circ}$ rotation. Due to the rotation axis of astigmatism, residual astigmatism is expected to occur and expect to adversely affect the eyes. Conclusions: Long-term using the glasses without correction of increased astigmatic and rotated axis on near vision should occur new residual astigmatism and increase the asthenopia also. Considered to be taken astigmatic change on near vision during near refraction examination.

During the COVID-19 pandemic, Relationship between smart device usage time, eye health status, and eye health awareness among health college students (COVID-19 판데믹 시기에 보건계열대학생의 스마트기기 사용시간, 눈건강 실태, 눈건강 의식 간의 관계)

  • Yoon, Hyeon Gyeong;Kim, So Yeong;Park, Min Ji;Park, Ji Eun;Jeon, Hye Jin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.187-195
    • /
    • 2022
  • This study was conducted to confirm the relationship between smart device usage time, eye health status, and eye management consciousness during the COVID-19 Pandemic period for college students in the health field. The study participants were 188 health-related university students, and data analysis was performed using descriptive statistics, independent t-test, Chi-square test, one-way ANOVA, and Pearson's correlation coefficients using the SPSS 26.0 program. As a result of the study, the average of the subjects' eye fatigue score was 15.23±13.71, the dry eye subjective symptom score was 21.87±12.02, and the eye health management consciousness score was 3.48±1.09. Eye care awareness, dry eye symptoms (r=.152, p=.005) and eye fatigue, dry eye symptoms (r=.650, p<.001) were statistically significant positive correlation in the group using smartphones for 2 hours or more per day on average. Based on the results of this study, it is necessary to find a way to prevent eye health due to the use of smart devices by college students, and repeated studies are needed to confirm the factors affecting eye health.

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.

The Purchasing Trends of Purchase of Functional Progressive Addtions Lenses and Correlation Analysis of Binocular Function Value (기능성누진렌즈 구매고객의 구매동향 및 양안시기능값 상관성 분석)

  • Kim, Dong-min;Lee, Gi-yung;Park, Hyun-ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.255-261
    • /
    • 2015
  • Purpose: purchasing status and understanding trends of Functional progressive addtions lenses buyers', Correlation analysis of the Binocular Function value to determine ADD then can be apply sales and prescriptions. Methods: Years 2011 to 2014, 298 patients who were prescribed functional progressive lenses were analysed based on the prescription data and SPSS (Ver. 20.0) was treated using the statistics. Results: Results: The average age of our customers are $27.66{\pm}11.55$ years, average addition power is $+0.73{\pm}0.36D$, customers are using take a prescription of ADD $+0.75{\pm}0.28D$ was the highest 44.33% to 132 people. Near point of convergence of 276 people (92.62%) was mostly less than 10 cm, and near point of accommodation of 134 people (44.97%) was also below 10 cm, within 11~15 cm were 122 people (40.94%). Most of people were within normal range in terms of Near point of convergence and near point of accommodation, near point of accommodation tend to be longer than Near point of convergence. As you can see this result shows most of customers need extra help in their near point of accommodation instead of they are leak at it. FCC (Fused cross cylinder) check Value and ADD (addition power) tests showed that the value of a strong correlation (p=0.00), NPC and NPA were also p=0.001, the correlation of the NPC and ADD is p=0.003, In addition, NPA and ADD also showed a significant correlations (p=0.005). Near Point of Accommodation, negative relative accommodation, and positive relative accommodation are all significantly correlated (p=0.00). The short distance-related variables of the ADD which are NPC, NPA, Age, also appeared to side correlate significantly with each other. Conclusion: Binocular function values of the subjects were highly correlated with each other so precise examination is required. when Age young people are working at short distance, low ADD values was prescribed for solving discomfort. So, in the case of early presbyopia, accommodative insufficiency, or people feel fatigue when they often working at near although their accommodation function is normal, when functional progressive lenses are prescribed, expectation of this should be exactly notified.

Changes of Visual Acuity and Ophthalmic Symptoms in Female Workers examining Silver Plating Products (은도금제품 검사실 여성근로자들의 시력변화 및 안증상)

  • Ryu, Seung-Ho;Son, Jeong-Il;Lee, Soo-Jin;Song, Jae-Cheol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.567-576
    • /
    • 1997
  • To evaluate the effects of reflected glare on eyes, authors assessed the periodic health examination(1991-1996) & self-administered questionnaire data of a semiconductor producing company. The 13 lead frame(LF) department workers have been exposed to high reflected glare in the process for examining the silver plating products. We compared the data of connector(14) and clerical(12) workers as the non-exposed ones. Among LF department workers, 100% felt their visual acuity worsened(connector:81.8%, clerical:85.7%), and 70% had worn the glasses o. contact lenses(connector : 14.3%, clerical :40%) since working at the company. Major ophthalmic symptoms of the LF workers are asthenopia, tearing, decreased visual acuity, congestion and glare. Decrease of visual acuity by Hahn's line change of the LF workers is significantly high during a 5-year follow-up(p<0.05 by simple regression) compared with connector clerical workers.

  • PDF

The Evaluations of Phoria and AC/A Ratio by Watching 3D TV at Near (3D TV 근거리 시청에 따른 사위도와 조절성폭주비 평가)

  • Son, Jeong-Sik;Kim, Dong-Su;Kim, Jung-Ho;Kim, Jae-Do;Hamacher, Alaric;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.319-324
    • /
    • 2015
  • Purpose: This study was designed to evaluate the changes of phoria and calculated AC/A ratio, and their recovery time points by watching 3D television (3D TV). Methods: 50 subjects (male 30, female 20) of 20s to 40s ages who can watch 3D, were measured phoria using a Howell phoria card at 3 m for distance and 40 cm for near. The phoria was evaluated before watching 3D TV and every 10 minutes from starting of watching 3D TV for 30 minutes, and every 5 minutes after finishing of watching 3D TV for 30 minutes again. Results: For the distance phoria during and after watching 3D TV, it was increased to more exophoria $-0.98{\pm}1.37{\Delta}$ (prism diopters) after 10 minutes from starting of 3D TV watching (p=0.063) and increased to more exophoria $-1.00{\pm}1.28{\Delta}$ after 30 minutes (p=0.024), and started to decrease after finishing of watching 3D TV and recovered to the level of before 3D TV watching ($-0.78{\pm}1.11{\Delta}$) after 20 minutes (p=0.32) with comparing to phoria of before watching 3D TV ($-0.80{\pm}1.12{\Delta}$). For the near phoria, it was also increased to more exophoria $-5.71{\pm}4.45{\Delta}$ after 10 minutes from starting of watching 3D TV (p=0.000) and $-6.58{\pm}4.36{\Delta}$ after 30 minutes (p=0.000), and started to decrease after finishing of watching 3D TV and recovered to the level of before watching 3D TV after 20 minutes ($-4.34{\pm}3.67{\Delta}$) (p=0.32) with comparing to the phoria of before watching 3D TV ($-4.36{\pm}3.66{\Delta}$). AC/A ratio was decreased from $4.92{\pm}1.17{\Delta}/D$ for before 3D TV watching to $4.11{\pm}1.50{\Delta}/D$ for after 30 minutes from starting of watching 3D TV (p=0.000), and increased after the end of watching 3D TV and recovered to the level of before 3D TV watching ($4.93{\pm}1.18{\Delta}/D$) after 25 minutes (p=0.598). Conclusions: During watching 3D TV at near, it showed a tendency of convergence insufficiency by decrease of calculated AC/A ratio as result that exophoria at near was higher increased than exophoria at distance. However, the increased exophoria at both near and distance was recovered to the level of base line after 25 minutes from the end of watching 3D TV. Through this study, it seems to need rational proposals of advice for watching 3D TV.