The Assessment on the Insulation Condition of Generator Stator Windings by a Novel Parameter PDI(Partial Discharge Index) (새로운 파라메타인 부분방전 변화지수에 의한 발전기 고정자 권선의 절연상태 평가)

  • Hwang, Don-Ha;Park, Do-Yeong;Kim, Yong-Ju;Kim, Jin-Bong;Ju, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.11
    • /
    • pp.735-741
    • /
    • 1999
  • The monitoring and assessment on the insulation condition of generator stator windings have been an important task of utility companies. The interest for the assessment of insulation condition has been increasing due to the need to keep old generating equipment reliable in order to extend the equipment life and to increase the generating capacity. Even though many developments and research activities for the condition assessment of generator insulation have been performed for decades, the assessment criterion in order to consistently predict the actual insulation condition is still in question. In this paper, the correlation between the parameters and the insulation condition is analyzed through the various non-destructive diagnostic tests in order to establish the assessment criterion on insulation deterioration of generator stator windings. By analyzing the correlation, PDI(Partial Discharge Index) as a novel parameter for the assessment criterion on insulation diagnosis of stator winding is proposed and verified.

  • PDF

A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS (GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구)

  • Koo Ja-Yoon;Chang Yong-Moo;Choi Jae-Ok;Yeon Man-seung;Lee Ji-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

Features Extraction and Mechanism Analysis of Partial Discharge Development under Protrusion Defect

  • Dong, Yu-Lin;Tang, Ju;Zeng, Fu-Ping;Liu, Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.344-354
    • /
    • 2015
  • In order to study the development of partial discharge (PD) under typical protrusion defects in gas-insulated switchgear, we applied step voltages on the defect and obtained the ${\varphi}-u$ and ${\varphi}-n$ spectrograms of ultra-high frequency (UHF) PD signals in various PD stages. Furthermore, we extracted seven kinds of features to characterize the degree of deterioration of insulation and analyzed their values, variation trends, and change rates. These characteristics were inconsistent with the development of PD. Hence, the differences of these features could describe the severity of PD. In addition, these characteristics could provide integrated characteristics regarding PD development and improve the reliability of PD severity assessment because these characteristics were extracted from different angles. To explain the variation laws of these seven kinds of parameters, we analyzed the relevant physical mechanism by considering the microphysical process of PD formation and development as well as the distortion effect generated by the space charges on the initial field. The relevant physical mechanism effectively allocated PD severity among these features for assessment, and the effectiveness and reliability of using these features to assess PD severity were proved by testing a large number of PD samples.

Assessment of Insulation Condition in Gas Turbine Generator Stator Windings (가스터빈 발전기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Yang, Gyu-Hyun;Ju, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1423-1428
    • /
    • 2010
  • The results of off-line and on-line diagnostic tests performed on the stator winding of an air-cooled gas turbine(G/T) generator are reported in this paper. Off-line diagnostic tests included measurements of the ac current, dissipation factor(tan${\delta}$), and partial discharge(PD). Six epoxy-mica capacitors were installed in the three phases of G/T generator for performing on-line diagnostic testing with the turbine generator analyzer(TGA). The TGA showed that the normalized quantity number(NQN) and the PD magnitude($Q_m$) were high in phase A of the stator winding. Internal discharges were generated in phases B and C, and slot discharge occurred in phase A. According to the trend analyses of the NQN and $Q_m$ values available for insulation condition assessment for G/T generator stator windings, it was concluded that phases B and C were in good condition, whereas phase A has been significantly deteriorated.

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.

A study on the heat cycle aging of insulation materials in large generator stator windings (대형발전기 고정자권선 절연재료의 열 사이클에 의한 열화에 관한 연구)

  • 김희곤;박영관
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.553-557
    • /
    • 1996
  • Heat cycle aging of insulating materials in large generator stator winding has been investigated using both on-line and off-line test methods. On this study, principally, off-line test against actual generator in service was carried out to acquire information about polarization index(PI) and dissipation factor, dissipation factor tip-up, maximum partial discharge for the purpose of remnant breakdown voltage and life assessment. It was found from the tests that both dissipation factor and maximum partial discharge decreased with the increase of operating hours and starting numbers. It was found from off-line tests that the remnant breakdown voltage had a strong relationship with both dissipation factor and maximum partial discharge the remnant breakdown voltage as a results of both operating hours and starting number and the nondestructive tests were proposed as parameters which can predict the remnant lifetime of insulating materials in large generator stator windings. (author). 8 refs., 8 figs., 2 tabs.

  • PDF

A Safety Assessment of Splice of 6/10[kV] Class CV Cables with Different Conductor Size (다른 굵기의 6/10[kV]급 CV 케이블 직선접속부 안전성 평가)

  • Jung, Jong-Wook;Kim, Sun-Gu;Jung, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.78-84
    • /
    • 2010
  • This paper describes the safety assessment of power cable splices connecting different sized 6/10[kV] class power cables. To assess the safety, AC withstand voltage tests, partial discharge tests and impulse tests were carried out to the cable splice specimens and thermal rise due to overload and cross section of joint were examined as well. As a result, a breakdown due to the $4.5[U_0](27[kV_{ac}])$ application could not found for 5 minutes. Under $1.73[U_0](10.4[kV_{ac}])$ application, partial discharges of 4~8[pC] were detected. In impulse tests, all the specimens withstood to the standard waveforms of $75[kV_{peak}](1.2{\times}50[{\mu}s])$ without any breakdowns. In addition, the temperature on the splice rose by $3[^{\circ}C]$ when the 200[A] flew through the splice for 20minutes, however the thermal rise of $3[^{\circ}C]$ was considered due to the atmospheric temperature. After all the electrical tests, the cross section of the splice was visually examined. The conditions of the conductors of both $185[mm^2]$ and $240[mm^2]$ were good.

A Simple Metric for Assessing the Severity of Partial Discharge Activity Based on Time-Sequence-Analysis-Discharge Level Patterns

  • Stewart Brian G;Yang Lily;Judd Martin D;Reid Alistair;Fouracre Richard A
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.313-318
    • /
    • 2006
  • This paper introduces a partial discharge (PD) severity metric, S, based on the evaluation of time-sequence PD data capture and resulting Time-Sequence-Analysis Discharge (TSAD) level distributions. Basically based on an IEC60270 measurement technique, each PD event is time stamped and the discharge level noted. By evaluating the time differences between a previous and subsequent discharge, a 3D plot of time-sequence activity and discharge levels can be produced. From these parameters a measurement of severity, which takes into account dynamic or instantaneous variations in both the time of occurrence and the level of discharge, rather than using standard repetition rate techniques, can be formulated. The idea is to provide a measure of the severity of PD activity for potentially measuring the state of insulation within an item of plant. This severity measure is evaluated for a simple point-plane geometry in $SF_{6}$ as a function of gap distance and applied high voltage. The results show that as the partial discharge activity increases, the severity measure also increases. The importance of future investigations, quantifications and evaluations of the robustness, sensitivity and importance of such a severity measurement, as well as comparing it with typical repetition rate assessment techniques, and other monitoring techniques, are also very briefly discussed.

Assessment of Insulation Condition in Operating Large Turbine Generator (운전중인 대형 터빈발전기에서 절연상태 평가)

  • 김희동
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.324-329
    • /
    • 2004
  • Six stator slot couplers(SSC) and a flux probe sensor installed on the stator winding slots of large turbine generator. Assessment of insulation condition has been based upon the measurements of partial discharge(PD) of stator windings and shorted-turn of rotor windings in operating large turbine generator. The maximum PD magnitude(Qm), normalized quantify number(NQN), PD pattern and shorted-turn were measured using on-line insulation condition monitoring system. The NQN and Qm of slot PD side in the phase A are indicated the highest value in six SSC sensors. Monitoring system results showed that discharge at conductor surface and internal discharge were detected at the surface of stator winding and in voids of the groundwall insulation. Insulation of stator and rotor windings in large turbine generator was judged to be in good condition.

Assessment of Insulation Condition in Large Turbine Generator Stator Windings (대용량 터빈발전기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Lee, Young-Jun;Park, Deok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2093-2096
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in three large turbine generators. Nondestructive tests have been carried out on stand-still generators which have been in service for 2 to 30 years. In most cases these tests include ac current increase rate($\Delta$I), delta tan delta( ${\Delta}tan{\delta}$), and maximum partial discharge(Qm). Gen. 2 show that the $tan{\delta}$ is higher than other two generators in the $tan{\delta}$-voltage curve. Partial discharge(PD) patterns were observed internal, corona and treeing discharges in large turbine generators. The PD tests were confirmed the correlation between discharge patterns and the kinds of defects.