• Title/Summary/Keyword: Assay sensitivity

Search Result 751, Processing Time 0.033 seconds

The Evaluation of Immunochromatographic Assay kit for Rapid Detection of Hepatitis B Surface Antigen (Hepatitis B Surface Antigen을 신속히 검출하기 위한 Immunochromatographic Assay kit의 성능 평가)

  • Shin, Hyeong-Soon;Kim, Young-Bong;Shin, Jung-Woo;Kim, Chang-Kyu;Lee, Wang-Sik;Kim, Han-Kyeom;Shin, Kwang-Soon
    • The Journal of Korean Society of Virology
    • /
    • v.27 no.2
    • /
    • pp.137-141
    • /
    • 1997
  • We evaluated Immunochromatographic assay kit to screen HBsAg in human serum. When the reference HBsAg was applyed to ICA, HA and EIA kits, the limit of detection for HBsAg were found out to be 4, 2 and 0.25 ng/ml respectively. But ICA kit required 5 minutes to read the result whereas HA and EIA kit more than one hour. The sensitivity was 97% (29 of 30 samples) and the specificity 100% (45 samples) compared with conventional EIA. The ICA kit needs no instrument or machine to perform the test contrary to the conventional methods. Therefore, this rapid and sensitive ICA kit can be used for HBsAg-screening, especially in the emergency room and in the scene of the accident.

  • PDF

A Fluorescent Recombinase Aided Amplification Assay for Detection of Babesia microti

  • Lin, Hong;Zhao, Song;Ye, Yuying;Shao, Lei;Jiang, Nizhen;Yang, Kun
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.3
    • /
    • pp.201-205
    • /
    • 2022
  • Babesia microti is one of the most common causative agents of babesiosis. A sensitive and rapid detection is necessary for screening potentially infected individuals. In this study, B. microti cytochrome c oxidase subunit I (cox1) was selected as the target gene, multiple primers were designed, and optimized by a recombinase-aided amplification (RAA) assay. The optimal primers and probe were labeled with fluorescein. The sensitivity of fluorescent RAA (fRAA) was evaluated using gradient diluents of the cox1 recombinant plasmid and genomic DNA extracted from whole blood of B. microti infected mice. The specificity of fRAA was assessed by other transfusion transmitted parasites. The analytical sensitivity of the fRAA assay was 10 copies of recombinant plasmid per reaction and 10 fg/µl B. microti genomic DNA. No cross-reaction with any other blood-transmitted parasites was observed. Our results demonstrated that the fRAA assay would be rapid, sensitive, and specific for the detection of B. microti.

Studies on enzyme immunoassay for determining progesterone of bovine plasma and its clinical application. II. Establishment of enzyme immunoassay for progesterone (Enzyme immunoassay(EIA)에 의한 소의 progesterone 측정과 이의 응용에 관한 연구 II. Progesterone 측정에 대한 효소면역측정방법(酵素免疫測定方法)의 확립)

  • Kang, Chung-boo;Shin, Jong-uk;Choe, Sang-yong
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.1
    • /
    • pp.21-25
    • /
    • 1989
  • This experiment was carried out to determine the progesterone concentration of bovine plasma by liquid phase double antibody enzyme immunoassay. The optimum conditions of assay-system, enzyme conjugate and gelatin were invested. The sensitivity, recovery rate and reproducibility by this assay were also analyzed. The results obtained were as follows: 1. The suitable supplementation level of gelatin was 0.2%. As the gelatin level increased to 1%, coefficient variation of interassay was shown to be irregular. 2. The optimum dilution rate of enzyme conjugate was 30 times. Enzyme activity was greatly fluctuated depending on the minor condition of enzyme conjugate technique. Therefore, it was considered to be checked when determined. 3. The sensitivity of the assay was 12 pg/tube. 4. Recovery rate was decreased when the amount of sample was too little or too much, but the recovery rate was high as 97.8% when the amount of sample between 50 and $200{\mu}l$. 5. Mean intra-assay and inter-assay coefficient of variation was 4.5% and 5.9%, respectively. By using liquid phase double antibody enzyme immunoassay, progesterone in plasma can be detected, and also this assay system is applicable to study on physiological function of progesterone and to diagnosis of reproductive disorders.

  • PDF

Detection of bovine rotavirus antigen by enzyme linked immunosorbent assay (효소면역법에 의한 소 로타바이러스 항원 검출)

  • 안재문;유기조;이용희;이종인
    • Korean Journal of Veterinary Service
    • /
    • v.19 no.1
    • /
    • pp.30-38
    • /
    • 1996
  • Enzyme-linked immunosorbent assay (ELISA) was developed to detect rotavirus antigen in fecal samples using VP6-specific monoclonal antibody(2B12). The ELISA for rotavirus antigen detection found to have specificity to all bovine and porcine rotaviruses tested but not to bovine viral diarrhea virus and bovine coronavirus. The ELISA appeared to have similar sensitivity and specificity compared to fluorescence antibody assay(FA) and electropherotyping (PAGE).

  • PDF

Comparison of In Vitro Cell Transformation Assay Using Murine Fibroblasts and Human Keratinocytes

  • Ahn, Jun-Ho;Park, Sue-Nie;Yum, Yung-Na;Kim, Ji-Young;Lee, Michael
    • Toxicological Research
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • The in vitro cell transformation assays (CTA) were performed using BALB/3T3 murine fibroblasts and HaCaT human keratinocytes in order to evaluate concordance between both in vitro CTAs and carcinogenicity with compounds differing in their genotoxic and carcinogenic potential. Six test articles were evaluated, two each from three classes of compounds: genotoxic carcinogens (2-amino-5-nitrophenol and 4-nitroquinoline-N-oxide), genotoxic noncarcinogens (8-hydroxyquinoline and benzyl alcohol), and nongenotoxic carcinogens (methyl carbamate and N-nitrosodiphenylamine). Any foci of size $\geq$2 mm regardless of invasiveness and piling was scored as positive in CTA with BALB/3T3. As expected, four carcinogens regardless of their genotoxicity had positive outcomes in two-stage CTA using BALB/3T3 cells. However, of the two genotoxic noncarcinogens, benzyl alcohol was positive CTA finding. We concluded that, of the 6 chemicals tested, the sensitivity for BALB/3T3 system was reasonably high, being 100%. The respective specificity for BALB/3T3 assay was 50%. We also investigated the correlation between results of BALB/3T3 assay and results from HaCaT assay in order to develop a reliable human cell transformation assay. However, evaluation of staining at later time points beyond the confluency stage did not yield further assessable data because most of HaCaT cells were detached after $2{\sim}3$ days of confluency. Thus, after test article treatment, HaCaT cells were split before massive cell death began. In this modified protocol for this HaCaT system, growing attached colonies were counted instead of transformed foci 3 weeks since last subculture. Compared to BALB/3T3 assay, HaCaT assay showed moderate low sensitivity and high specificity. Despite these differences in specificity and sensitivity, both cell systems did exhibit same good concordance between in vitro CTA and rodent carcinogenicity findings (overall 83% concordant results). At present the major weakness of these in vitro CTA is lack of validation for regulatory acceptance and use. Thus, more controlled studies will be needed in order to be better able to assess and quantitatively estimate in vitro CTA data.

A Rapid and Sensitive Two-Site Sandwich Enzyme-Linked Immunosorbent Assay for Detection of ${\alpha}$-Fetoprotein in Human Serum

  • Jang, Jeong-Su;Kim, Jeong-Min;Chung, Gi-Hyun;Paik, Bo-Hyun;Kim, Hack-Joo
    • BMB Reports
    • /
    • v.29 no.3
    • /
    • pp.192-199
    • /
    • 1996
  • A rapid and sensitive method has been developed to detect a-fetoprotein (AFP) in human serum by a two-site sandwich enzyme-linked immunosorbent assay (ELISA) with monoclonal antibodies (MAbs) for human AFP within 1 h. To obtain the most sensitive and reliable MAbs. 12 kinds of MAbs (HPJ1 to HPJ12) as a capture antibody and 4 kinds of horseradish peroxidase (HRP) conjugated MAbs as a tracer antibody were investigated. Among these, only HPJ 10-HRP conjugated HPJ 1 (HPJ 10-HPJ $1^*$) and HPJ 11-HRP conjugated HPJ 10 (HPJ 11-HPJ $10^*$) were chosen as candidates based on the linearity of the standard curve and the sensitivity of the assay. To further characterize these two pairs. MAbs against human AFP were purified from hybridoma cells. conjugated with HRP. and then characterized to optimize the two-site sandwich ELISA The HPJ 10-HPJ $1^*$ pair showed a sensitivity of 1 ng/ml and a better reproducibility than the HPJ 11-HPJ $10^*$ pair when the human sera were incubated at $37^{\circ}C$ for 30 min. The results obtained for 480 randomly selected human sera showed 0~20 ng/ml of AFP values for the normal human sera. To test the utility of our kit, AFP concentrations were determined for 951 human sera (including 85 normal sera, 480 random blood sera, 213 HBsAg-positives. 50 anti-HCV antibody positives. and 47 malignant diseases) and compared with other commercially available AFP detecting kits. These results show that the present two-site sandwich ELISA method is a rapid, sensitive, and reliable procedure for detecting AFP in human serum.

  • PDF

A comparison of agglutination tests and enzyme-linked immunosorbent assay for the bovine brucellosis (소 브루셀라병 혈청 항체가 응집반응 비교 시험)

  • Kim, Cheol-Ho;Bang, Sang-Young;Jeon, Jae-Hyung;Bhak, Jong-Sik;Lee, Min-Kwon;Shin, Jung-Sub
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.3
    • /
    • pp.315-329
    • /
    • 2008
  • A total of 710 bovine serum samples which are composed 532 bovine serum samples showed negative reaction and 178 bovine serum samples showed positive reaction with tube agglutination test (TAT) from North area of Gyeong-nam, Korea were tested using all the 3 assays which are Rose-Bengal test(RBT), tube agglutination test (TAT) and enzyme-linked immunosorbent assay (ELISA, two types) and analyzed for evaluation of specificity, sensitivity, reproducibility and predictive value. In the comparison of serum antibody titer agglutination test, RBT showed almost agreement with TAT. In the comparison of TAT and two types of ELISA method, they showed difference in specificity and sensitivity about 5%. But there is no significant difference in detecting sensitivity between two types of ELISA method and TAT. In serologic tests for bovine brucellosis, the new assay ELISA would be a good candidate for serologic survey for bovine brucellosis in Korea because it is efficient in detecting many test samples quickly. But the serum agglutination tests (RBT, TAT) are more economical and easy assay for detection. In the test of comparison of antibody titer between first day of finding and 10 days after finding by TAT, there was no change in 55% (76/139) of positive cattle.

Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2

  • Chiao-Hsu Ke;Mao-Yuan Du;Wang-Ju Hsieh;Chiu-Chiao Lin;James Mingjuh Ting;Ming-Tang Chiou;Chao-Nan Lin
    • Journal of Veterinary Science
    • /
    • v.25 no.2
    • /
    • pp.28.1-28.11
    • /
    • 2024
  • Background: Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. Objectives: This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. Methods: We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. Results: The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. Conclusions: The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.

The Optimal Condition of Performing MTT Assay for the Determination of Radiation Sensitivity (방사선 감수성 측정법으로서 MTT 법 시행 시의 최적 조건에 대한 연구)

  • Hong, Se-Mie;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.163-170
    • /
    • 2001
  • Purpose : The measurement of radiation survival using a clonogenic assay, the established standard, can be difficult and time consuming. In this study, We have used the MTT assay, based on the reduction of a tetrazolium salt to a purple formazan precipitate by living cells, as a substitution for clonogenic assay and have examined the optimal condition for performing this assay in determination of radiation sensitivity. Materials and Methods : Four human cancer cell lines - PCI-1, SNU-1066, NCI-H630 and RKO cells have been used. For each cell line, a clonogenic assay and a MTT assay using Premix WST-1 solution, which is one of the tetrazolium salts and does not require washing or solubilization of the precipitate were carried out after irradiation of 0, 2, 4, 6, 8, 10 Gy. For clonogenic assay, cells in $25\;cm^2$ flasks were irradiated after overnight incubation and the resultant colonies containing more than 50 cells were scored after culturing the cells for $10\~14$ days. For MTT assay, the relationship between absorbance and cell number, optimal seeding cell number, and optimal timing of assay was determined. Then, MTT assay was performed when the irradiated cells had regained exponential growth or when the non-irradiated cells had undergone four or more doubling times. Results : There was minimal variation in the values gained from these two methods with the standard deviation generally less than $5\%$, and there were no statistically significant differences between two methods according to t-test in low radiation dose (below 6 Gy). The regression analyses showed high linear correlation with the $R^2$ value of $0.975\~0.992$ between data from the two different methods. The optimal cell numbers for MTT assay were found to be dependent on plating efficiency of used cell line. Less than 300 cells/well were appropriate for cells with high plating efficiency (more than $30\%$). For cells with low plating efficiency (less than $30\%$), 500 cells/well or more were appropriate for assay. The optimal time for MTT assay was after 6 doubling times for the results compatible with those of clonogenic assay, at least after 4 doubling times was required for valid results. In consideration of practical limits of assay (12 days, in this study) cells with doubling time more than 3 days were inappropriate for application. Conclusion : In conclusion, it is found that MTT assay can successfully replace clonogenic assay of tested cancer cell lines after irradiation only if MTT assay was undertaken with optimal assay conditions that included plating efficiency of each cell line and doubling time at least.

  • PDF

Evaluation of Variation Method to Improve the Sensitivity of Immunoradiometric Assay (면역방사계수측정법의 민감도 향상을 위한 변법의 평가)

  • Won-Hyun Kwon;Mi-Ji Kang;;Ji-Sol Park;Jung-In Kim;Kyung-Jae Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose The concentration of PSA (Prostate Specific Antigen) after radical prostatectomy in prostate cancer patients is a predictor of biochemical recurrence, and the AUA (American Urological Association) is defined as biochemical recurrence when the concentration of PSA is measured at 0.2 ng/mL or more, and when the concentration is measured at 0.2 ng/mL or more at the retest. This standard is also applied our hospital. In this laboratory, the PSA reagent using IRMA (Immunoradiometric Assay) is used, and the sensitivity at a very low value was not as good as the reagent used in the department of laboratory medicine. This study aims to increase the reliability of the results by improving the precision and sensitivity of very low values. Materials and Methods As a reagent for the study, PSA reagent using IRMA was used. As a method to improve the precision and sensitivity of very low values, a variation method on the serum volume(25 uL, 50 uL, 100 uL, 200 uL) was studied, and variation usefulness evaluation was conducted. The evaluation items were compared the results of precision, analytical sensitivity, recovery rate, dilution test, high-dose hook effect test, parallel test and very low concentration values(n = 20). Results The validation results were displayed in the order of 25 uL, 50 uL, 100 uL, 200 uL. As the serum volume increased, it was confirmed that CV (Coefficient of Variation)(%) improved. Analytical sensitivity(ng/mL) was 0.038, 0.041, 0.017, 0.015 and recovery rate(%) was 101±3, 101±3, 99±2, 97±4. very low concentration values(ng/mL) between each volume(n=20) were 0.135±0.068, 0.076±0.050, 0.048±0.034, 0.046±0.034. and high dose hook effect appeared as the serum volume increased. Conclusion Through the variation usefulness evaluation, it was confirmed that as the serum volume increased, the precision and sensitivity improved at very low concentration values. However, it is necessary to pay special attention to the occurrence of high-dose hook effect as the serum volume increases. In the case of tests that requires very low concentration values, it is thought that the reliability of the result will be increased if the variation method is properly used after the variation usefulness evaluation.

  • PDF