• Title/Summary/Keyword: As-welded

Search Result 1,405, Processing Time 0.027 seconds

An Experimental Study for Longitudinal Resistance of Ballast Track on Bridge (교량 상 자갈궤도의 종저항력 측정을 위한 실험 연구)

  • Min, Kyung-Hwan;Yun, Kyung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • When a ballast track of a high-speed train is constructed on a bridge, the displacement of the bridge decks can occur because they are not fixed to the rails. Moreover, relative displacements occur between the bridge and rails caused by temperature changes and external loads. The current longitudinal resistance criteria (UIC Code 774-3, KR C-08080) on ballast tracks with continuous welded rails (CWRs) do not take into account the longitudinal movement of the bridge and the frictional force between the ballast and slabs. In addition, the magnitude of the longitudinal resistance, k, is calculated somewhat conservatively and, (therefore?) it acts as an unfavorable element in the design of long span and continuous railway bridges. Thus, in order to replicate the actual behavior more effectively, the longitudinal resistance of CWRs should take into account the additional rigidity between the slab and track. In this study, the longitudinal resistances of the ballasted track on the bridge were analyzed by carrying out an experimental study with a test setup designed to simulate the deck and bed track. In the test results, the maximum longitudinal resistances of the tests were similar to the resistances of the current codes, however, the measured longitudinal stiffness designed to limit the displacement of the tests were much smaller in comparison with the longitudinal stiffness on the codes.

Analysis on the Flexural Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 휨 거동 분석)

  • Son, Guk-Won;Yu, Sung-Young;Lim, Cheol-Woo;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.56-66
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Seismic resistant test of anchored and welded steel plate connections manifested an average of 2.8 times increase in the maximum loading (average 591.8 kN) in comparison to unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.4% and 2.7%. An analytical study was performed while assuming the RC column on the right side and the vertical element of the reinforced PC panel to behave in completely composite manner and the RC column on the left side and PC panel to behave in completely non-composite manner when loading was exerted from upper right end of RC frame of specimen to its left side. It was found with the assumptions that the overall flexural behavior in principle agreed with the experimental result.

An Evaluation on the Shear Strength of New Type Shear Connectors for a Simple Steel-Concrete Composite Deck (초간편 강합성 바닥판 신형식 전단연결재의 전단내력 평가)

  • Yoon, Ki Yong;Kim, Sang Seup;Han, Deuk Cheon
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.519-528
    • /
    • 2008
  • A simple steel-concrete composite deck is developed for preventing the lateral torsional buckling of girders that are under construction and for reducing the term of works using H-shaped rolled beams as bridge girders. A new type of shear connectors is also developed for the composite behavior between a simple steel-concrete composite deck and the rolled beams by the connecting conditions between the deck and the girders. One is a connector bolt that is lengthened and split or tightened with two nuts and the other is an I-shaped rolled beam welded on a steel plate with a number of holes punched through the web. In this study, to estimate the shear strength of those shear connectors the push-out tests are performed and the test results are compared with that of the previous studies and the codes. The result of the push-out tests of the connector bolts showed that the shear performance is similar to that of the stud connector and revealed that the equation for the shear strength in the Korean Specification of Highway Bridge overestimates the shear capacity of the connector bolt whose diameter is larger than 19mm. From the push-out tests of punched I-shaped rolled beams with varying welding amounts, with the small amount of welding, shear capacity is governed by the shear capacity of welding. On the other hand, shear capacity is governed by the size of the punched I-shaped rolled beams, regardless of the amount of welding.

A Comparative Study on the Current Status of Spectacle Frames Standards (안경테 표준규격 실태에 관한 비교 연구)

  • Yu, Dong-Sik;Kim, In-Su;Son, Jeong-Sik;Sung, Duk-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: The aim of this study is to examine various national standards and to suggest problems and improvements on KS (Korean Industrial Standards) in spectacle frames. Methods: We surveyed the latest published KS, ISO (International Organization for Standardization), JIS (Japanese Industrial Standards), DIN (Deutsches Institut fur Normung) and ANSI (American National Standards Institute) standards with relating spectacle frames. The titles that were considered in comparative study were terms and vocabulary, measuring system and terminology, marking, requirements and test methods, formers, screw threads, and others. Results: There were 9 different languages such as English (USA and UK), French, Russian, Japanese, Chinese, German, Italian and Spanish for the lists of equivalent terms and vocabulary in all standards except KS and ANSI, but gave an explanation for terms and vocabulary in only KS. Complementary terms and definitions were not existed in annex of KS and ANSI for measuring system and terminology, but they were included in annex of standards of the others. KS and ANSI standard for requirements and test methods differed from the ISO revision. Except JIS and ANSI, standards of formers were almost identical. KS standard of screw threads were similar to JIS. Standards of welded joints and nickel release did not exist in KS. Conclusions: All standards except ANSI tend to follow ISO, especially DIN is almost entirely identical to ISO. But KS is behind the times because it has been amended lately or established in accordance with older editions of ISO. Therefore, in order to assist quality control and safety for spectacle frames, KS standards shall be superseded by the specifications which is identical to ISO within a reasonable time.

  • PDF

Evaluation of Fracture Toughness in Steel Weldment for Inner Wall of LNG Storage Tank (LNG 저장탱크 내조용 강 용접부의 파괴인성 평가)

  • Jang J.-i.;Ju J.-B.;Yang Y.-c.;Kim W.-s.;Hong S. H.;Kwon D.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.7-13
    • /
    • 1998
  • In this study, for the safety performance of LNG storage tank, the fracture toughness in X-grooved weld HAZ(heat-affected zone) of $9\%$ Ni steel was evaluated qualitatively and quantitatively, and the relation with the change in microstructure was analyzed. The toughness assessment was peformed through the modified CTOD test proposed for thick weldment with X-groove. Additionally, microstructures of HAZ were evaluated by OM, SEM and XRD. From the results, HAZ toughness of SMA(shielded metal arc)-welded $9\%$ Ni steel decreased as the evaluated region approached the fusion line. The decrease in toughness was apparently caused by the increase in the fraction of coarse-grained zone within HAZ. On the other hand, toughness drop with decreasing test temperature in F.L.(fusion line) ${\~}$F.L.+3mm was larger than that in F.L.+5mm${\~}$F.L.+7mm region due to the fact that in the former regions, retained austenite had poor stability.

  • PDF

Evaluation of Characteristics of Welding Zones Welded with Inconel 718 Filler Metal to Piston Crown Forged Material (피스톤 크라운용 단강에 인코넬 718 용접재료로 용접된 용접부의 특성 평가)

  • Lee, Sung-Yul;Moon, Kyung-Man;Jeong, Jae-Hyun;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.334-340
    • /
    • 2016
  • The combustion chamber of a diesel engine is often exposed to a more serious wear and corrosion environment than other parts of the engine because its temperature increases as a result of using heavy oil of low quality. Therefore, repair and built-up welding methods must be performed on worn or corroded parts of the piston crown, exhaust valve, etc. from an economical point of view. In this study, Inconel 718 filler metal was used in repair welding on the groove of a forged steel specimen for a piston crown, along with built-up welding on the surface of another forged steel specimen. Then, the corrosion characteristics of the weld metal zone for the repair welding and the deposited metal zone for the built-up welding were investigated using electrochemical methods in a 35% H2SO4 solution. The deposited metal zone indicated better corrosion resistance than the weld metal zone, showing a nobler corrosion potential, higher impedance, and smaller corrosion current density. It is considered that metal elements with good corrosion resistance were generally included in the filler metal, and these elements were also greatly involved in the deposited meta by built-up welding, whereas the weld metal consisted of metal elements mixed with both the filler metal and base metal elements because of the molten pool produced by the repair welding. Finally, it is considered that the hardness of the weld metal was increased by the repair welding, whereas the built-up welding improved the corrosion resistance of the deposited metal.

Optimum Stiffness of the Sleeper Pad on an Open-Deck Steel Railway Bridge using Flexible Multibody Dynamic Analysis (유연다물체동적해석을 이용한 무도상교량 침목패드의 최적 강성 산정)

  • Chae, Sooho;Kim, Minsu;Back, In-Chul;Choi, Sanghyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.2
    • /
    • pp.131-140
    • /
    • 2022
  • Installing Continuous Welded Rail (CWR) is one of the economical ways to resolve the challenges of noise, vibration, and the open-deck steel railway bridge impact, and the SSF method using the interlocking sleeper fastener has recently been developed. In this study, the method employed for determining the optimum vertical stiffness of the sleeper pad installed under the bridge sleeper, which is utilized to adjust the rail height and absorb shock when the train passes when the interlocking sleeper fastener is applied, is presented. To determine the optimal vertical stiffness of the sleeper pad, related existing design codes are reviewed, and, running safety, ride comfort, track safety, and bridge vibration according to the change in the vertical stiffness of the sleeper pad are estimated via flexible multi-body dynamic analysis,. The flexible multi-body dynamic analysis is performed using commercial programs ABAQUS and VI-Rail. The numerical analysis is conducted using the bridge model for a 30m-long plate girder bridge, and the response is calculated when passing ITX Saemaeul and KTX vehicles and freight wagon when the vertical stiffness of the sleeper pad is altered from 7.5 kN/mm to 240 kN/mm. The optimum stiffness of the sleeper pad is calculated as 200 kN/mm under the conditions of the track components applied to the numerical analysis.

Palaeomagnetism of the Cretaceous Yuchon Group in Kosong Area, Southern Kyongsang Basin (경상분지 남단 고성지역의 백악기 유천층군에 대한 고자기 연구)

  • Kang, Hee-Cheol;Kim, In-Soo
    • Journal of the Korean earth science society
    • /
    • v.21 no.6
    • /
    • pp.663-674
    • /
    • 2000
  • A total of 165 independently oriented core samples were collected from 19 Cretaceous Yuchon Group sites in Kosong area, the southernmost part of the Miryang subbasin of the Kyongsang Basin in southern Korea. Stepwise AF and thermal cleaning revealed antipodal ChRM from 95 samples from 14 sites. Mean ChRM direction is d=26.0$^{\circ}$, i=49.4$^{\circ}$ (${\alpha}_{95}$=8.2$^{\circ}$, k=24.5, n= 14) before bedding correction and d=28.1$^{\circ}$, i=54.2$^{\circ}$ (${\alpha}_{95}$=4.8$^{\circ}$, k=70.6, n= 14) after bedding correction. A 2.88-fold increase of the precession parameter k by bedding correction indicates pre-folding age of the ChRM with 99% confidence level. Palaeomagnetic pole position calculated from the mean ChRM is 67.0$^{\circ}$N, 210.6$^{\circ}$E (dp=4.7$^{\circ}$, dm=6.7$^{\circ}$), which is significantly different neither from the poles of other part of the Kyongsang Basin nor those of Eurasia including SCB and NCB. This suggests stable relative position of the study area with regard to other parts of the Kyongsang Basin as well as to Eurasia continent since Cretaceous. Three ploarity reversals in the Kosong Formation in addition to the coexistence of normal and reversed polarities in the overlying Andesites and Welded Tuff suggest, in reference to the worldwide geomagnetic polarity time scale, an Albian to Maastrichtian (polarity chron 32r-31r) age of the Yuchon Group of the study area. An alleged hypothesis of stratigraphical correspondence between the Kosong Formation in the study area and the Tadaepo Formation in Pusan area is, however, not tenable: Not only because the latter shows a short reverse polarity only in its lowest part of the sequence but also because the Andesites overlying it is wholly normally magnetized, in contrast to the frequent reverals in the case of both the Kosong Formation and Andesites above it.

  • PDF

HISTOLOGIC CHANGES IN MANDIBULAR PERIODONTIUM OF THE MONKEY FOLLOWING EXPERIMENTAL EXTRUSION OF ANTERIOR TEETH (실험적 전치 정출시 원숭이 하악 치주 조직의 변화)

  • Lee, Sung-Youn;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.403-414
    • /
    • 1995
  • The purpose of this study was to investigate the histologic changes in mandibular periodontium during overbite closure for openbite treatment by continuous arch wires and anterior vertical elastics. Two female monkey(Macaca nemestrina) with permanent dentition were used. Posterior bite block was fixed to each of their maxillae, which made the animal temporary anterior openbite as well as stabilized the whole maxillary anchorage. In each mandible, all the teeth except the second molars which had been extracted, were prepared for cast crowns. 018 inch Standard brackets were welded on these crowns. After cementation, two types of the $016{\times}022$ inch continuous arch wires, the plain ideal arch to the control animal and the MEAW(multiloop edgewise archwire) to the other experimental one were inserted. Then anterior vertical elastics were applied for two weeks. The overbite depth changes in the monkeys and histologic examinations of the mandibular periodontiums suggested the following conclusions. 1. During two weeks of the experimental period, the overbite increased + 0.3 mm in the control and + 1.3 mm in the experimental one. 2. In both the control and the experimental animal, histologic examinations showed that incisors, canines and first premolars were subject to extrusive force and the rest of posteriors were subject to intrusive one. 3. In periodontiums of the extruded incisors of the experimental one, reorientation of the periodontal fiber structures reflected the direction of force and the alveolar bone surfaces including apical and crestal areas which had been subject to tension, were the front of new bone formation. 4. In periodontiums of the extruded incisors of the experimental one, neither excessive hyalinization nor gross root resorption was observed. 5. Alveolar bone remodeling of anteriors and posteriors was more remarkable in the experimental one than the control.

  • PDF

Hydrothermal Alteration Related to Cretaceous Felsic Magmatism in the Seongsan Dickite Deposits, Korea; Estimation of Ore - Forming Temperature and aNa+/aK+ Ratio of the Hydrothermal Fluid (성산딕카이트광상에서의 백악기산성마그마티즘에 관련된 열수변질작용 ; 광상형성온도의 측정 및 열수용액의 aNa+/aK+)

  • Kim, In Joon
    • Economic and Environmental Geology
    • /
    • v.25 no.3
    • /
    • pp.259-273
    • /
    • 1992
  • The Seongsan mine is one of the largest dickite deposits in the southwestern part of the Korean Peninsula. The main constithent minerals of the ore are dickite and quartz with accessory alunite, kaolinite and sericite. The geology around the Seongsan mine consists mainly of the late Cretaceous felsic volcanic rocks. In the studied area, these rocks make a synclinal structure with an axis of E-W direction plunging to the east. Most of the felsic volcanic rocks have undergone extensive hydrothermal alteration. The hydrothermally altered rocks can be classified into the following zones: Dickite, Dickite-Quartz, Quartz, Sericite, Albite and Chlorite zones, from the center to the margin of the alteration mass. Such zonal arrangement of altered rocks suggests that the country rocks, most of which are upper part of the rhyolite and welded tuff, were altered by strongly acid hydrothermal solutions. It is reasonable to consider that initial gas and solution containing $H_2S$ and other compounds were oxidized near the surface, and formed hydrothermal sulfuric acid solutions. The mineralogical and chemical changes of the altered rocks were investigated using various methods, and chemical composition of fifty-six samples of the altered rocks were obtained by wet chemical analysis and X.R.F. methods. On the basis of these analyses, it was found that some components such as $SiO_2$, $Al_2O_3$, $Fe_2O_3$, CaO, MgO, $K_2O$, $Na_2O$ and $TiO_2$ were mobilized considerably from the original rocks. The formation temperature of the deposits was estimated as higher than $200^{\circ}C$ from fluid inclusion study of samples taken from the Quartz zone. On the basis of the chemical composition data on rocks and minerals and estimated temperatures, the hydrothermal solutions responsible for the formation of the Seongsan dickite deposits were estimated to have the composition: $m_{K^+}=0.003$, $m_{Na^+}=0.097$, $m_{SiO_2(aq.)}=0.008$ and pH=5.0, here "m" represents the molality (mole/kg $H_2O$).

  • PDF