• Title/Summary/Keyword: Artificial implant

Search Result 139, Processing Time 0.029 seconds

EVALUATION OF THE INTERFACES BETWEEN IMPLANTS AND REGENERATED BONE USING BONE MORPHOGENETIC PROTEIN AND DEMINERALIZED FREEZE-DRIED BONE (임플란트 매식시 골형성단백질 및 탈회동종골 사용에 따른 골재생 및 계면에 대한 연구)

  • Kang, Sang-Gyu;Lee, Jong-Ho;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.1
    • /
    • pp.24-39
    • /
    • 2000
  • Various methods and graft materials have been used to fill in the defect adjacent to the implants and considered as clinically acceptable. But it is not clear whether the regenerated bone increases the implant-bone contact and supports the implant. The purpose of this study is to evaluate regenerated bone surrounding implants using bone morphogenetic protein(BMP) and demineralized freeze-dried bone(DFDB), and the interfaces between implants and regenerated bone. bBMP was extracted and partially purified from the bovine bone matrix using heparine chromatography. Demineralized freeze-dried bone was made from the dog. Inactive insoluble collagenous bone matrix(IBM) of dog was used as carrier of bBMP. Interfaces of titanium coated epoxy resin implants were processed for demineralized section for transmission electron microscopy(TEM) and those of screw type implants were for nondemineralized section for light and fluoromicroscopic examination. Implants were inserted in the inferior border of mandible of adult dogs and artificial bony defects($3{\times}3{\times}4mm$) were made at the mesial and distal side of implants. Defects were filled with BMP(BMP group) and DFDB(DFDB group). For the fluoromicroscopic examination, the fluorescent dyes(oxytetracycline, calcein green, alizarin red) were injected 2, 4, 6, 8, 12 weeks after implantation. The experimental animals were sacrificed at the 6th and the 12th week and their mandible were extirpated and processed for examination with light microscopy, fluoromicroscopy and TEM. The obtained results were as follows : 1. By the light microscopic findings, the defects were filled with woven bone at the 6th week and compact bone at the 12th week, and the osseointegrations were seen in both groups. There was no histological difference between them. 2. On the basis of the histomorphometric analysis, BMP group(6th week: 40.25%, 12th week: 56.04%) had higher bony contact ratio than DFDB group(38.37%, 42.63%). There was significant difference between two groups at the 12th week(p<0.05). 3. The amount of bone formation in BMP group was more prominent than in DFDB group. Significant difference was noted among two groups at the 6th and the 8th week(p<0.05). 4. By the transmission electron microscopic findings, $0.4-2{\mu}m$ soft tissue layer was found in adjacent to the interfaces and over the collagen fibrils of bone at the 6th week. However, about 100nm amorphous layer was noted at the interface or collagen fibrils directly extended to the titanium surface at the 12th week. There was no significant difference between two groups. 5. These results suggest that BMP and DFDB can be used as good graft materials in the regeneration of bone adjacent to implant, and BMP is more valuable as a bone inducer than DFDB.

  • PDF

A STUDY ON THE BONE FORMATION OF GRAFT MATERIAL CONTAINING DEMINERALIZED BONE MATRIX WITH A SIMULTANEOUS INSTALLATION OF IMPLANT (임프란트 식립시 이식된 탈회골기질을 함유한 이식재의 골형성에 대한 연구)

  • Kim, Yeo-Gab;Yoon, Byung-Wook;Ryu, Dong-Mok;Lee, Baek-Soo;Oh, Jung-Hwan;Kwon, Yong-Dae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.6
    • /
    • pp.481-491
    • /
    • 2005
  • Purpose: The aim of the present study is to evaluate the effect of autogenous bone and allograft material coverd with a bioresorbable membrane on bone regeneration after a simultaneous installation of implant. Materials and methods: Twelve healthy rabbits, weighing about $3{\sim}4$ kg, were used in this experiment. Following impalnt(with 3.25 mm diameter and 8 mm length) site preparation by surgical protocol of $Oraltronics^{(R)}$, artificial bony defect, 5mm sized in height and depth, was created on femoral condyle using trephine drill(with 5 mm diameter and 5 mm length). Then implant was inserted. In the experimental group A, the bony defect was filled with autogenous particulated bone and coverd with $Lyoplant^{(R)}$ resorbable membrane. In the experimental group B, the bony defect was filled with allograft material(Orthoblast $II^{(R)}$) containing demineralized bone matrix and covered with $Lyoplant^{(R)}$. In the control group, without any graft materials, the bony defect was covered with $Lyoplant^{(R)}$. The experimental group A and B were divided into each 9 cases and control group into 3 cases. The experimental animals were sacrificed at 3, 6 and 8 weeks after surgery and block specimens were obtained. With histologic and histomorphometric analysis, we observed the histologic changes of the cells and bone formation after H-E staining and then, measured BIC and bone density with KAPPA Image $Base^{(R)}$ system. Results: As a result of this experiment, bone formation and active remodeling process were examined in all experimental groups and the control. But, the ability of bone formation of the experimental group A was somewhat better than any other groups. Especially bone to-implant contact fraction ranged from 12.7% to 43.45% in the autogenous bone group and from 9.02% to 29.83% in DBM group, at 3 and 8 weeks. But, bone density ranged from 15.67% to 23.17% in the autogenous bone group and from 25.95% to 46.06% in DBM group at 3 and 6 weeks, respectively. Although the bone density of DBM group was better than that of autogenous bone group at 3 and 6weeks, the latter was better than the former at 8 weeks, 54.3% and 45.1%, respectively. Therefore these results showed that DBM enhanced the density of newly formed bone at least initially.

Cranioplasty with Custom-made Artificial Bone after Resection of Multilobular Bone Tumor in a Dog (개의 다엽성 골종양 제거후 커스텀 메이드 인공뼈를 이용한 두개골성형술)

  • Choi, Sungjin;Honnami, Muneki;Liu, I-Li;Yamamoto, Kenichi;Ohba, Shinsuke;Echigo, Ryosuke;Suzuki, Shigeki;Nishimura, Ryouhei;Chung, Ung-Il;Sasaki, Nobuo;Mochizuki, Manabu
    • Journal of Veterinary Clinics
    • /
    • v.31 no.1
    • /
    • pp.46-50
    • /
    • 2014
  • A 7-year-old spayed female Welsh corgi presented with a mass of the skull. The mass was diagnosed as multilobular bone tumor and surgically removed. To treat a large bone defect after the tumor removal, custom-made artificial bone fabricated by a 3-dimensional ink-jet printer was implanted in the defect. Follow-up computed tomography evaluation was performed for 4.3 years. The implant was well integrated with the skull and had covered the large bone defect during the follow-up period. Gradual degradation of the implant began 6 weeks after surgery. It provides an additional option for the treatment of large bone defect.

Effect of Progesterone Implant and Follicular Rupture on Estrus Induction and Fertility in Anestrus Cows (무발정우에서 Progesterone Implant와 Follicular Rupture에 따른 발정유도 및 임신율)

  • 최상용;황영균;이성림;조상래;옥선아;노규진
    • Journal of Embryo Transfer
    • /
    • v.18 no.2
    • /
    • pp.115-124
    • /
    • 2003
  • The objective of this study was to compare the effect of four different estrus induction methods in anestrus cows on the estrus induction and pregnancy following artificial insemination (AI). Sixty-five cows (3∼4 years old) were selected and divided into four different estrus induction treatment groups. Group 1, 12 cows were treated by Ovsynch program combined with GnRH and PGF$_2$a. Group 2, 12 cows were treated by "Tow plus Two" program with GnRH and PGF$_2$a. Group 3, 20 cows were treated by "Tow plus Two" program following intravaginal progesterone implantation (CIDR). Twenty one cows in Group 4 were treated by "Tow plus Two" program following follicular rupture and intravaginal progesterone implantation. Cows were then observed estrus induction and inseminated artificially at 12 h and 24 h after standing estrus. The rates of estrus induction in Group 4 (18/21, 86%) was significantly (P<0.05) higher than those in groups 1, 2 and 3 (8/12, 67%; 9/12, 75%; 14/20, 70%). In the mean time of onset of estrus after final administration of GnRH in different hormone-treated cows, the cows in Group 3 (24.2$\pm$2.2) and Group 4 (23.4$\pm$2.0) were significantly (P<0.05) shorter than that in Group 1 (28.5$\pm$4.6) and Group 2 (26.4$\pm$3.3). The rates of pregnancy diagnosed on Day 28 were significantly different between treatment groups. Significantly (P<0.05) higher rate of pregnancy was observed in Group 4 (17/20, 85.0%) than those in Groups 1, 2 and 3 (7/11, 63.6%; 8/12, 66.7%; 15/20, 75.0%, respectetively). The rate of abortion diagnosed on 49 days of gestation was significantly (P<0/05) lower in Group 4 (1/17, 5.9%) than those in Groups 1, 2 and 3 (2/7, 28.7%; 2/8, 25% and 3/15, 20%, respectively). In conclusion, combined treatments with GnRH and PGF$_2$a following follicular rupture and progesterone implant in anestrus cows was considered to be most effective in estrus induction and maintenance of pregnancy. Further studies are needed to verify the functional mechanisms of residual follicles in anestrus ovaries on retarding the response of hormonal treatments.sponse of hormonal treatments.

Effects of Repeated Instrumentation for Periodontal Therapy on the Marginal Portion of Artificial Crown (치주처치를 위한 기구들의 반복조작이 인공치관 변연부에 미치는 영향)

  • Kim, Jae-Ho;Yun, Gi-Yon;Choi, Kwang-Soo;You, Hyung-Keun;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.443-455
    • /
    • 2000
  • The aim of periodontal therapy is a removal of a bacterial plaque butthe instrumentation for plaque control has two nature : removal of a bacterial plaque and increase of surface roughness. Complication of instrumentation is enable to damage to the root surface and artificial crown. Therefore this study was conducted to evaluate the effects of repeated instrumentation on the marginal portion of artificial crown. Fifteen proximal surfaces of ten extracted periodontally diseased maxillary first molars were used. The finish line was placed on the root surface, and then the crown was casted and cemented in usual manner. Three kinds of instruments: hand curet, ultrasonic scaler, and ultrasonic curet were used. After instrumentation, final polishing was done with rubber cup and pumice. And surface changes were evaluated by stereomicroscope and scannig probe microscope. Roughness was increased after instrumentation in all groups, and was decreased after polishing except ultrasonic scaler group. Roughness in the ultrasonic scaler group was lower than others, and roughness after polishing in the hand curet group was lower than others. These results indicate that polishing procedure is recommended, because periodontalinstruments increase the surface roughness and induce the irreversible damage to the marginal portion.

  • PDF

Partial Denture Prosthesis Implant and Necessity Thereof in Korean Elderly : Analysis of the Data from the 5th National Health Nutrition Survey(2010-2012) (한국노인의 가공의치 보철장착실태 및 필요도: 제5기 국민건강영양조사자료 분석(2010-2012))

  • Yun, Hyun-Kyung;Lee, Jong-Hwa;Lee, Seung-Hee
    • Journal of Digital Convergence
    • /
    • v.12 no.6
    • /
    • pp.467-479
    • /
    • 2014
  • The purpose of this study was to provide the data for discussion related to oral health promotion policies for the elderly by examining and analyzing the prosthesis conditions and necessity for the fixed and removable dentures among the Korean elderly. The data, obtained from 4,557 elderly aged at 65 or higher who were targeted for the 5th National Health Nutrition Survey, were analyzed through the complex sample frequency analysis, complex sample cross analysis, and complex sample logistic regression analysis. The results of analysis showed significant relevance of whole denture implant and the necessity thereof in older subjects, rural community, and subjects with lower education background, regarding the state of upper jaw/lower jaw prosthesis and the necessity for upper jaw/lower jaw fixed partial denture/whole denture. In addition, the necessity for prosthesis implant was found to have correlation with the income and subjective health condition, while the necessity for artificial teeth(denture) was found to have correlation with the gender, age, education, and subjective oral health condition. Therefore, it is considered necessary to map out the prevention and treatment policies designed to help maintain and promote oral health based on oral health education, along with the policies that aim to recover the neutralized oral health functions, in relation to the oral health of the elderly.

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

Analysis of the Contact Pressure Distribution and Kinetics of Knee Implant Using the Simulator (Simulator를 이용한 인공무릎관절 접촉면의 압력분포 및 운동성 분석)

  • 이문규;김종민;김동민;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.363-367
    • /
    • 2003
  • Contact area and pressure are important factors which directly influence a life of knee implants. Since implant's mechanical functions should be experimentally evaluated for clinical use, many studies using a knee simulator and a pressure sensor system have been conducted. However it has not been reported that the contact pressure's distribution of a knee implant motion was estimated in real-time during a gate cycle. Therefore. the objective of this study was to analyze the contact pressure distribution for the motion of a joint using the knee simulator and I-scan sensor system. For this purpose, we developed a force-controlled dynamic knee simulator to evaluate the mechanical performance of artificial knee joint. This simulator includes a function of a soft tissue and has a 4-degree-of-freedom to represent an axial compressive load and a flexion angle. As axial compressive force and a flexion angle of the femoral component can be controlled by PC program. The pressure is also measured from I-scan system and simulator to visualize the pressure distribution on the joint contact surfaces under loading condition during walking cycle. The compressive loading curve was the major cause for the contact pressure distribution and its center move in a cycle as to a flexion angie. In conclusion, this system can be used to evaluate to the geometric interaction of femoral and tibial design due to a measured mechanical function such as a contact pressure, contact area and a motion of a loading center.

Treatment with upper complete denture and lower implant-fixed restorations on an elderly patient presenting fully edentulous maxilla and bilateral posterior edentulous mandible: a case report (상악 완전무치악 및 하악 양측 구치부 결손 고령환자에 대한 상악 가철성, 하악 고정성 보철치료: 증례보고)

  • Joseph Junesirk Choi;Richard Leesungbok;Suk-Won Lee;Phyo Ei Ei Htay;Jeong-yun Park;Jin-Young Chon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.284-292
    • /
    • 2023
  • Stable posterior occlusal support is crucial for adequate masticatory function and facial aesthetics. In elderly patients over the age of 65, masticatory ability has a significant impact on nutritional intake and overall health. This case report presents a prosthetic treatment of an elderly patient with edentulous maxilla and bilateral posterior edentulous mandible. The upper jaw was restored with a complete denture to establish an ideal occlusal plane, and the three-dimensional positions of the mandibular implants were determined accordingly. The implants were placed through computer-guided implant surgery and were immediately loaded with fixed provisional restorations. The implant-fixed zirconia final restorations were inserted in the lower posterior region, and the occlusal surface of posterior artificial teeth in the upper denture was substituted with cobalt-chrome alloy to resist occlusal wear. The patient's posterior occlusal support and masticatory function were promptly restored through this treatment process, and long-term stability against wear was also obtained.

Enhancing Security Gaps in Smart Grid Communication

  • Lee, Sang-Hyun;Jeong, Heon;Moon, Kyung-Il
    • International Journal of Advanced Culture Technology
    • /
    • v.2 no.2
    • /
    • pp.7-10
    • /
    • 2014
  • In order to develop smart grid communications infrastructure, a high level of interconnectivity and reliability among its nodes is required. Sensors, advanced metering devices, electrical appliances, and monitoring devices, just to mention a few, will be highly interconnected allowing for the seamless flow of data. Reliability and security in this flow of data between nodes is crucial due to the low latency and cyber-attacks resilience requirements of the Smart Grid. In particular, Artificial Intelligence techniques such as Fuzzy Logic, Bayesian Inference, Neural Networks, and other methods can be employed to enhance the security gaps in conventional IDSs. A distributed FPGA-based network with adaptive and cooperative capabilities can be used to study several security and communication aspects of the smart grid infrastructure both from the attackers and defensive point of view. In this paper, the vital issue of security in the smart grid is discussed, along with a possible approach to achieve this by employing FPGA based Radial Basis Function (RBF) network intrusion.