• Title/Summary/Keyword: Artificial Slot

Search Result 39, Processing Time 0.02 seconds

Development of Artificial Intelligence-based Legal Counseling Chatbot System

  • Park, Koo-Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.3
    • /
    • pp.29-34
    • /
    • 2021
  • With the advent of the 4th industrial revolution era, IT technology is creating new services that have not existed by converging with various existing industries and fields. In particular, in the field of artificial intelligence, chatbots and the latest technologies have developed dramatically with the development of natural language processing technology, and various business processes are processed through chatbots. This study is a study on a system that provides a close answer to the question the user wants to find by creating a structural form for legal inquiries through Slot Filling-based chatbot technology, and inputting a predetermined type of question. Using the proposal system, it is possible to construct question-and-answer data in a more structured form of legal information, which is unstructured data in text form. In addition, by managing the accumulated Q&A data through a big data storage system such as Apache Hive and recycling the data for learning, the reliability of the response can be expected to continuously improve.

A Study of Space Harmonics of Induction Motor Using Artificial Neural Network (인공신경회로망을 이용한 유도전동기 공간고조파 저감에 관한 연구)

  • Bae, Dong-J.;Koh, Chang-S.;Jung, Hyun-K.;Hahn, Song-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.101-103
    • /
    • 1995
  • This paper describes new tecknique to obtain optimum value in calculating space harmonics in the motor design. First, develops general procedure in calculating slot harmonics, MMF harmonics, and systhesis of them. And then, trains Artificial Neural Network by classical method. Once trained ANN, it also computing different input data more quickly.

  • PDF

Beam Steering Antenna Using Microstrip Patch with U-Slot for Wearable Fabric Applications (의복용 U-슬롯을 갖는 빔 조향 마이크로스트립 안테나)

  • Ha, Sang-Jun;Jung, Chang-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.8
    • /
    • pp.754-760
    • /
    • 2011
  • Reconfigurable beam steering using microstrippatch antenna with U-slot is proposed for wearable fabric applications. The proposed antenna is manufactured on a fabric substrate, and designed to steer the beam directions at the operation frequency of 6.0 GHz. The U-shaped slot and the indirect feeding-techniques are utilized in designing the proposed antenna. By the configuration of two artificial switches($S_0$, $S_1$, $S_2$) in between the indirect feed and the antenna patch, the antenna has three beam directions. The maximum beam directions are steerable in the yz-plane(${\theta}=0^{\circ}$, $30^{\circ}$, $331^{\circ}$), and the overall HPBW is $115^{\circ}$. The measured peak gains are 6.11~6.69 dBi.

Humidity Sensor Using Microstrip Patch Antenna (마이크로스트립 패치 안테나를 이용한 습도 센서)

  • Junho Yeo
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.1
    • /
    • pp.71-76
    • /
    • 2023
  • In this paper, a humidity sensor using a microstrip patch antenna(MPA) and polyvinyl alcohol(PVA) is studied. PVA is a polymer material whose permittivity changes with humidity, and a rectangular slot is added to the radiating edge of the MPA, which is sensitive to changes in electric field, in order to increase the sensitivity to changes in relative permittivity. After thinly coating the area around the radiating edge with the rectangular slot of the MPA fabricated on a 0.76 mm-thick RF-35 substrate with PVA, the changes in the resonant frequency and magnitude of the MPA's input reflection coefficient are measured when relative humidity is adjusted from 40% to 80% in 10% increments at a temperature of 25 degrees using a temperature and humidity chamber. Experiment results show that when the relative humidity increases from 40% to 80%, the resonance frequency of the antenna' input reflection coefficient decreases from 2.447 GHz to 2.418 GHz, whereas the magnitude increases from -7.112 dB to -3.428 dB.

A Branch-Line Hybrid Using Triangle-Patch Type Artificial Transmission Line (삼각 패치형 인공 전송 선로를 이용한 브랜치 라인 하이브리드)

  • Oh, Song-Yi;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.768-773
    • /
    • 2012
  • A branch-line hybrid using microstrip artificial transmission lines(ATLs) with slotted-triangular patches is proposed. The proposed artificial transmission line is compact in structure as well as easy to adjust the characteristic impedance and electrical length of equivalent transmission line by changing the slot's parameters; hence, it is useful for miniaturizing conventional transmission lines. The designed branch-line hybrid, because of the use of the right angled isosceles triangular shaped artificial transmission lines as building blocks, has no useless empty space, and hence optimally miniaturized. A fabricated 3 dB branch-line hybrid shows the coupling variation of ${\pm}0.5$ dB and the phase difference between two output ports of $91^{\circ}{\pm}4^{\circ}$ within 15 % bandwidth at 2.45 GHz center frequency. The size of proposed branch-line hybrid is only 38% of the conventional branch-line hybrid.

Judgement Criterion of Insulation Deterioration in 4.16kV and 6.6kV Motor Stator Windings (4.16kV 및 6.6kV 전동기 고정자 권선의 절연열화 판정기준)

  • Kim, Hee-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.788-794
    • /
    • 2009
  • To assess the condition of stator insulation, nondestructive tests were performed on twenty five coil groups and twenty six motors. The stator windings has nominal ratings of 6.6kV and are classified into five coil groups ;one group with healthy insulation and four groups with four different types of artificial defects. After completing nondestructive tests, the AC voltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No.1, No.2 and No.6 of 6.6kV motors failed near rated voltage of 14kV, 8.7kV and 14kV, respectively. The breakdown voltage of three motors was lower that expected for good quality coils(14.2kV) in 6.6kV motors. No.3 and No.6 of 4.16kV motors failed near rated voltage of 5.6kV and 4.2kV, respectively. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor(tan${\delta}$) and partial discharge magnitude.

The Analysis of Fracture Propagation in Hydraulic Fracturing using Artificial Slot Model (인공슬롯을 고려한 수압파쇄 균열의 발전양상에 관한 연구)

  • 최성웅;이희근
    • Tunnel and Underground Space
    • /
    • v.5 no.3
    • /
    • pp.251-265
    • /
    • 1995
  • One of the most important matters in stress measurement by hydraulic fracturing technique is the determination of the breakdown pressure, reopening pressure, and shut-in pressure, since these values are the basic input data for the calculation of the in-situ stress. The control of the fracture propagation is also important when the hydraulic fracturing technique is applied to the development of groundwater system, geothermal energy, oil, and natural gas. In this study, a laboratory scale hydraulic fracturing device was built and a series of model tests were conducted with cube blocks of Machon gabbro. A new method called 'flatjack method' was adopted to determine shut-in pressure. The initial stress calculated from the shut-in pressure measured by flatjack method showed much higher accuracy than the stress determined by the conventional method. The dependency of the direction of fracture propagation on the state of the initial stresses was measured by introducin g artificial slots in the borehole made by water jet system. Numerical modeling by BEM was also performed to simulate the fracture propagation process. Both results form numerical and laboratory tests showed good agreement. From this study which provides the extensive results on the determination of shut-in pressure and the control of fracture propagation which are the critical issue in the recent hydraulic fracturing, it is conclued that in-situ stress measurement and the control of fracture propagation could be achived more accurately.

  • PDF

A STUDY ON THE CHANCES OF FRICTIONAL FORCE BETWEEN BRACKET AND ORTHODONTIC WIRE WITH TIME IN ARTIFICIAL SALIVA (시간경과에 따른 교정용 bracket과 교정선 사이의 마찰력 변화에 관한 연구)

  • Kwak, Chun;Kim, Jim-Bom;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.283-294
    • /
    • 1993
  • The friction of orthodontic appliances is recogonized to be detrimental to tooth movement. The purpose of this study was to determine the magnitude of frictional force changes between bracket$(018'\times025'\;solt)$ and orthodontic wires(stainless steel, cobalt-chromium, and $\beta-titanium$, $017'\times0.25'$ rectangular) with time. The wire was secured in the bracket slot with a elastomeric ligature. Frictional forces were measured by universal testing machine. The following conclusions were obtained. 1. The frictional forces under dry condition were greater than those in saliva. 2. The frictional forces produced by cobalt-chromium wire were less than those generated by stainless steel and $\beta-titanium$ wire. 3. The frictional forces increased progressively with time, and the amount of increase on first two weeks was greater than on last two weeks. 4. The change of frictional force under dry condition was greater than in artificial saliva.

  • PDF

A Study on the Spot Inspection for LCD Modules (LCD모듈의 얼룩검사에 관한 연구)

  • Lee, Jae-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.422-424
    • /
    • 2006
  • This paper suggests an automatic spot-inspection algorithm for LCD modules. Usually, LCD module testing is classified by two categories. One is for uniform pattern testing and the other is Non-uniform testing. The uniform pattern testing is well defined and also fully automated in the factory. However non-uniform pattern testing is not defined well yet, so non-uniform testing is conducted by human operators. In this paper a spot-pattern, which is one of non-uniform pattern, inspection algorithms are proposed. The performance of the proposed algorithm is tested by extensive simulations using artificial slot-patterns and real ones in the LCD modules.

  • PDF

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일의 부분방전 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2091-2093
    • /
    • 2005
  • Five model coils of 6.6kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals, respectively The voltage applied to the coils was 3.81kV, 4.76kV, 6.0kV and 6.6kV. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector (PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns coincide with both PDD and TGA.

  • PDF