• 제목/요약/키워드: Array Probe

검색결과 218건 처리시간 0.031초

헬리콥터 탑재 MTD 레이다용 도파관 슬롯배열 안테나 (Waveguide Slot Array Antenna for Heliborne MTD Radar)

  • 김동석;한인희;곽영길;신근섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(1)
    • /
    • pp.139-142
    • /
    • 2004
  • X-band Waveguide slot way antenna is developed for heliborne MTD radar applications. The antenna is composed of multi-layer waveguide structures. Each of them has it's own functions, such as, radiation, power/phase distribution, coupling, etc. Broad-wall offset slots are used for radiators, inclined slots on broad-wall for power distribution to radiating(branch) waveguide, some kind of coaxial probe structures for in-phase coupling and H-plane T-junction power dividers. Antenna is realized by precision machining and careful assembly. It is tested and measured by 3m${\times}$l.7m planar near-field probe, which is set-up in MTG. Far-field calculations have good agreement in tolerable bounds. Special but necessary process such as brazing, will increase the accuracy and performance. Results show promising possibilities of future applications for real systems.

  • PDF

A Study on Gene Detection using Non-labeling DNA

  • Choi Yong-Sung;Lee Kyung-Sup;Kwon Young-Soo
    • 한국전기전자재료학회논문지
    • /
    • 제19권10호
    • /
    • pp.960-965
    • /
    • 2006
  • This research aims to develop the multiple channel electrochemical DNA chip using microfabrication technology. At first, we fabricated a high integration type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the gold electrodes. Then target DNAs were hybridized and reacted. Cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. Therefore, it is able to detect a plural genes electrochemically after immobilization of a plural probe DNA and hybridization of non-labeling target DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.

Multipoint Process Monitoring System Based on a Near Infrared Ray(NIR) Acousto-Optic Tunable Filter(AOTF)

  • You, Jang-Woo;Kim, Daesuk;Kim, Soohyun;Kong, Hong-Jin;Lee, Yunwoo;Kwak, Yoon-Keun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.105.4-105
    • /
    • 2001
  • This paper describes a newly designed multipoint process monitoring system based on a NIR acousto-optic tunable filter. The NIR multipoint process monitoring system consists of a NIR AOTF device for wavelength selection, an InGaAs array sensor, and a specially designed iin-line type of optical fiber probe. Unlike a FTS(Fourier Transform Spectrometry) or grating based monitoring system, an AOTF has no moving parts, and it can be rapidly tuned to any wavelength in its operating range within microseconds. Thus, the AOTF is advantageous in terms of faster spectral imaging capability and rigidity required for industrial monitoring environment. In the current feasibility evaluation, an enhanced optical fiber probe with 3 monitoring points was used. However, ...

  • PDF

기상측정시스템과 오차보정을 이용한 가공정밀도 향상 (Machining Accuracy Improvement by On Machine Part Measurement and Error Compensation)

  • 최진필;민병권;이상조
    • 한국정밀공학회지
    • /
    • 제20권12호
    • /
    • pp.34-41
    • /
    • 2003
  • This paper suggests a methodology fur improving the machining accuracy by compensating for the machining errors based on on-machine measurement process. Probing errors and machine tool errors included in the measurement data were calibrated or compensated to obtain the actual machining errors. Machine tool errors were modeled in forward and backward directions according to the axis movement direction to consider the effects of backlash errors on the measurement data, and model parameters were determined by measuring a cube array artifact. A rectangular workpiece was machined and then measured with a touch probe as a verification experiment. Machining experiments showed that the machining errors were reduced to within the designated tolerance after compensating for the actual machining errors by modifying the original footpath for the next-step machining.

비수식화 DNA를 이용한 차세대형 바이오칩의 개발 (Development of Next Generation Biochip Using Indicator-free DNA)

  • 최용성;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.71-73
    • /
    • 2006
  • This research aims to develop a multiple channel electrochemical DNA chip using micro- fabrication technology. At first, we fabricated a high integrated type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the gold electrodes. Then target DNAs were hybridized by an electrical force. Redox peak of cyclic-voltammogram showed a difference between target DNA and mismatched DNA in the anodic peak current. Therefore. it is able to detect a various genes electrochemically after immobilization of a various probe DNA and hybridization of label-free DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF

휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정 (Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System)

  • 강나루;우영아;차봉수;이현철;김효진
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

미소전극형 DNA칩 어레이를 이용한 유전자의 검출 (A Study on Electrical Properties of Dendrimer)

  • 최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1324-1326
    • /
    • 2006
  • In this study, an integrated microelectrode array was fabricated on glass slide using microfabrication technology. Probe DNAs consisting of mercaptohexyl moiety at their 5-end were spotted on the gold electrode using micropipette or DNA arrayer utilizing the affinity between gold and sulfur. Cyclic voltammetry in 5mM ferricyanide/ferrocyanide solution at 100 mV/s confirmed the immobilization of probe DNA on the gold electrodes. When several DNAs were detected electrochemically, there was a difference between target DNA and control DNA in the anodic peak current values. It was derived from specific binding of Hoechst 33258 to the double stranded DNA due to hybridization of target DNA. It suggested that this DNA chip could recognize the sequence specific genes. It suggested that multichannel electrochemical DNA microarray is useful to develop a portable device for clinical gene diagnostic system.

  • PDF

차세대형 바이오칩의 개발 및 비수식화 표적 DNA를 이용한 유전자 검출 (Development of New Biochip and Genome Detection Using an Non-labeling Target DNA)

  • 최용성;박대희;권영수;천합지인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.51-53
    • /
    • 2002
  • This research aims to develop a multiple channel electrochemical DNA chip using micro-fabrication technology. At first, we fabricated a high integrated type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the sold electrodes. Then target DNAs were hybridized by an electrical force. Redox peak of cyclic-voltammogram showed a difference between target DNA and mismatched DNA in the anodic peak current. Therefore, it is able to detect a various genes electrochemically after immobilization of a various probe DNA and hybridization of label-free DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF

의료용 초음파프로브의 압전소자 결함이 과도음장과 B-모드 영상에 미치는 영향 (Influences of the Defective Piezo-Elements of a Medical Ultrasonic Probe on Transient Acoustic Fields and B-Mode Images)

  • 최광윤;하강렬;김무준;김정순;양정화;강관석;최민주
    • 한국음향학회지
    • /
    • 제29권8호
    • /
    • pp.476-482
    • /
    • 2010
  • 전체 192개의 압전소자 중 64개를 동시 구동하여 빔을 형성하는 중심주파수 3.5 MHz인 선형배열 의료용 초음파프로브를 대상으로 일부의 압전소자가 결함으로 인해 동작하지 않을 때의 과도음장 및 점 표적에 대한 초음파 B-모드 영상을 시뮬레이션하여 정상 초음파프로브의 것과 비교 분석하였다. 그 결과, 결함소자의 수가 한 개에서 네 개로 증가함에 따라 주엽이 만드는 음장의 최대음압준위 및 그 -3 dB 폭은 정상일 때에 비해 선형적으로 감소하나, 초점심도는 거의 변화가 없고, 부엽에 의한 음장의 음압준위 상승으로 인해 주엽과 부엽과의 음압 차이는 감소하는 경향을 보였다. 이와 같은 음압준위의 변화는 점 표적에 대한 B-모드 영상에 영향을 주어 표적의 좌우에 허상을 만들며, 축 방향의 공간분해능은 거의 일정하나 측 방향으로는 다소 감소하는 경향을 나타내었다.

딥 브레이징 제작 기법을 이용한 밀리미터파 탐색기용 도파관 광벽 슬롯 배열 모노펄스 안테나 (Waveguide Broad-Wall Slot Array Monopulse Antenna for Millimeter-Wave Seeker Using Dip Brazing Method)

  • 백종균;정채현;이국주;박창현
    • 한국전자파학회논문지
    • /
    • 제26권11호
    • /
    • pp.1020-1026
    • /
    • 2015
  • 본 논문에서는 Ka 대역 밀리미터파 탐색기용 도파관 광벽 슬롯 배열 모노펄스 안테나의 설계 및 딥 브레이징 기법으로 제작하여 측정한 결과에 대해 기술하였다. 제안된 안테나는 Elliott 방법을 사용하여 최적화된 복사면, 반사 손실 대역폭 특성 향상을 위해 프로브 급전 방식이 적용된 급전 도파관 및 모노펄스 비교기로 구성되어 있다. 복사면 배열의 가중치 값은 Tayor 분포를 적용하여 설계하였으며, 상용 전자파 해석 시뮬레이터를 사용하여 단일 슬롯의 특성을 추출하여 Elliott 방법으로 슬롯 배열을 최적화 하였다. 설계한 안테나는 딥 브레이징 제작 기법으로 제작하였고, 측정을 통해 28.4 dBi 이득을 확인하였으며, 안테나 빔폭 및 부엽준위도 설계결과와 유사함을 확인하였다.