• Title/Summary/Keyword: Arm Movement

Search Result 365, Processing Time 0.024 seconds

Comparison of Muscle Activity in the Contralateral Lower Extremity from the PNF Arm Pattern and Leg Pattern (PNF 팔·다리 패턴에 따른 반대측 다리의 근활성도 비교)

  • Kim, Hee-Gwon
    • PNF and Movement
    • /
    • v.15 no.2
    • /
    • pp.177-183
    • /
    • 2017
  • Purpose: This study compared and analyzed the effect of the proprioceptive neuromuscular facilitation (PNF) arm extension pattern and leg flexion pattern on the contralateral lower extremity muscles when the patterns were applied to the same subject. Methods: In the study, 35 healthy men and women who understood the PNF patterns were selected as participants. The participants completed the PNF arm extension-abduction-internal rotation pattern and leg flexion-adduction-external rotation with knee flexion pattern in the supine position. While the patients' completed each pattern, the contralateral leg muscle activity was measured to examine the irradiation effect. The maximum isometric contraction time of the muscles to be measured was kept for 5 seconds, and the mean value was obtained by repeating the pattern three times. Results: When the leg flexion-adduction-external rotation with knee flexion pattern was completed, the muscle activity in the vastus lateralis, vastus medialis, biceps femoris, tibialis anterior, and gastrocnemius of the contralateral lower extremity was significantly greater than that found in the PNF arm extension-abduction-internal rotation pattern. Conclusion: The PNF leg flexion pattern showed greater muscle activity on the contralateral lower extremity than the arm extension pattern. Thus, the PNF leg extension pattern is more effective in the activation of the muscles associated with weight-bearing activity.

Body Surface Changes at Armhole Area for the Pattern of Armhole Line (진동둘레선 설계를 위한 진동체표변화에 관한 연구)

  • 이정란;임원자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.5
    • /
    • pp.930-942
    • /
    • 1996
  • This study was done to provide the characteristics of body surface changes at armhole area. Experiments were carried out at upper arm and upper body inchuding 67 items, 74 segments by the stanard posture and arm movements. The subjects were 15 females of twenty aged. The major conclusions of this study are; 1. On the circumference items of upper arm, armhole circumference was decreased by all arm movement, especially high contracted on front armhole line. The most contracted segments of armhole circumference were from the shonlder point to front and back interscye breadth point. Axillary circumference was increased 5 cm to the utmost, so the function of sleeve pattern would be decided by axillary circumference. 2. The lengths of upper arm were decreased near center line, sleeve cap length was contracted 3∼4 cm. Posterior armpit point area was increased both length and breadth. According to the rates of expansion and contraction, the diagram of expansion and contraction of upper arm was suggested. 3. On upper body, back side chest breadth was increased exceedingly and shoulder length was decreased most. It was apparent that surface changes of upper body were greatly larger as far away from center front and center back line. The rates of expansion and contraction of upper body were also represented as a diagram of surface changes.

  • PDF

Shift Steering Control of 2-axis ARM Helicopter based on a Neural Network (신경망 학습을 이용한 2축 ARM 헬리콥터의 중심이동 조향법)

  • Bae, Hyun-Soo;Kim, Byung-Chul;Lee, Suk-Gyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.677-683
    • /
    • 2015
  • This paper proposes a helicopter direction adjustment system using barycenter shift. Most conventional methods for direction adjustment of uniaxial helicopters rely on the angle of inclination of the main rotor. However, the inherent burden of the bearing of the main rotor and serious abrasion of the helicopter using the above methods may results in loss of balance. To decrease abrasion and enhance the barycenter stability, the proposed method was used to shift the barycenter of the helicopter instead of the main rotor for direction adjustment. We set a biaxial ARM on a uniaxial helicopter to adjust the direction of ARM pointing as well as to realize stable direction control when the helicopter loses its balance. The method may enhance the landing safety of helicopters in emergencies. Uniaxial helicopters can be controlled under any environment by adjusting the motor parameters of the ARM which is dependent on the center of mass using neural network. The experiment results show that the helicopter can return to the starting position quickly under the external disturbance.

The Effect of Arm Movements in the during Standing Position on Lower Limb Global Synkinesis and Balance in Stroke Patients

  • Moon, YoungJun;Jeong, DaeKeun;Kang, Jeongil
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.3
    • /
    • pp.1849-1855
    • /
    • 2019
  • Background: Stroke patients require arm movement exercising for various stimulations in standing position for various stimulations rather than in a sitting position because they require integrated skillful movements, such as stretching, holding, and controlling. Objective: This study was conducted to provide foundational clinical data about lower limb global synkinesis in stroke patients using arm movements in a standing position. Design: Randomized controlled trial. Methods: The subjects were divided into a control group (n = 10) and an experimental group (n = 10), and a pre-test was conducted to evaluate leg global synkinesis (GS) and balance. Intervention method is stretching an arm to hold a ball, repeating supination and pronation of the hand only while maintaining the arm extended as much as possible, repeating shoulder abduction and adduction while holding the pegboard. This was followed by a three-week intervention during which re-measurement was conducted in the same way as was done for the pre-test. Results: The control group showed a significant difference in GS and balance during plantar flexion (p<.05), and the experimental group showed a significant difference in GS and balance during all movements (p<.05, p<.01, respectively). There was a significant difference in GS and balance between the two groups during dorsiflexion (p<.05, p<.01, respectively). Conclusion: The findings demonstrate that human arm movements in a standing position can reduce GS in the affected limb, and balance can be improved by stimulating the surrounding tissues of the affected limb and changing them positively.

가상 tool의 조작을 통한 simulation 환경에서의 force display에 관한 연구

  • 이승룡
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.220-226
    • /
    • 1996
  • This paper describes the force display system which presents feel information to the operator through manipulating a virtual tool with a master arm in the simulated environment. The movement of a tool grasped by the operator, which is modeled as a circle or a square is displayed in the graphic screen of a computer. When the tool contacts with the virtual environment, the operator is forced to feel contact and the feature of the virtual environment through torque control of the master arm. Contact situations are modeled as close as to the reality considering the friction, and multiple contacts. Several experients are conducted and the effectiveness of the developed system is confirmed.

  • PDF

Component-based density propagation for human body tracking (인체 추적을 위한 구성요소 기반 확률 전파)

  • Shin, Young-Suk;Cha, Eun-Mi;Lee, Kyoung-Mi
    • Journal of Internet Computing and Services
    • /
    • v.9 no.3
    • /
    • pp.91-101
    • /
    • 2008
  • This paper proposes component-based density propagation for tracking a component-based human body model that comprises components and their flexible links. We divide a human body into six body parts as components - head, body, left arm, right arm, left foot, and right foot - that are most necessary in tracking its movement. Instead of tracking a whole body's silhouette, using component-based density propagation, the proposed method individually tracks each component of various parts of human body through a human body model connecting the components. The proposed human body tracking system has been applied to track movements usee for young children's movement education: balancing, hopping, jumping, walking, turning, bending, and stretching. This proposed system demonstrated the validity and effectiveness of movement tracking by independently detecting each component in the human body model and by acquiring an average 97% of high tracking rate.

  • PDF

Analysis of connecting joint anglle and moment in arm landing action in Sports Aerobics (스포츠에어로빅스 팔착지 동작의 연계관절 각도와 모멘트분석)

  • Yoo, Sil
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.311-325
    • /
    • 2003
  • A relation between the movement range of arms and arising moment has been studied to find out efficient movement range to minimize impact concerning arm landing in sports aerobics. Four male athletes who won top three in national-level sports aerobics competition were chosen for the experiment. They were allowed to jump in between two force platform so that the right hand and the right leg could land onto the front and rear force platform, respectively. The sampling frequency was 200 Hz. The main conclusions based on the analysis of the angle and joint moment parameters of wrist, elbow, and shoulder are as follows: 1. The wrist moment was small when its angle was small, indicating that the dorsi-flexion of the wrist joint offered a positive influence to reduce wrist moment. 2. The elbow angle increased as wrist angle decreased and vice versa. This means that the movement range of the wrist joint affects that of the elbow joint. The darsi-flexion of the wrist is the position to absorb the impact of the elbow effectively rather than to absorb the impact of the wrist itself. The impact is absorbed by the flexion of wrist joint rather than the wrist. 3. The degree of moment transfer of the shoulder joint, having absorbed the impact from the elbow and elbow joint, became dependent on the efficiency of the fore-joints impact absorption.

Determination of the Elbow Transverse Joint Using the Helical Axis Concept and its Application to the Development of a Kinematic Arm Model (나선축 개념을 이용한 팔꿈치 관절의 3차원 회전축 측정과 측정 결과를 반영한 인체 팔 모델의 개발)

  • Woo, Bum-Young;Jung, Eui-S.;Yun, Myung-Hwan
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2000
  • To determine the exact direction and location of the human joint in motion is crucial in developing a more accurate human model and producing a more fitting artificial joint. There have been several reports on the biomechanical analysis of the joint to determine the anatomy and movement of joints. However, all the previous researches were made in vitro study, that is, they investigated the passive movement of the joint from cadavers and the suggested location of the joint axis was difficult to make practical applications due to the lack of the direction of joint axis. Also, in many biomechanical models, each joint axis is assumed to lie horizontally or vertically to the adjacent links. Such an assumption causes inherent inaccuracy. In this study, the direction and location of the transverse elbow axis was obtained with respect to the global coordinate system whose origin is on the lateral epicondyle of the humerus. The suggested result based on the global coordinate system lying on the external landmark will be helpful to understand the information of the axis and to make an application. From the experiments conducted for five subjects, the direction and location of the elbow transverse joint was determined for each subject by the helical axis method. A statistical validation was also performed to confirm the result. Finally, the result was applied to develop a simple elbow model which is a part of the kinematic arm model. The simple elbow movement model was developed to validate the significance of the result and the kinematic arm model was able to describe the geometry of any complex linkage system. As a result, the errors incurred from the proposed model were significantly reduced when compared to the ones from the previous approach.

  • PDF

Body Composition of Male College Students by Standard Guideline for Korean Dietary (식생활 실천 지침에 따른 남자 대학생의 체성분 분석)

  • Chung Hee-Chung;Chang Kyung-Ja
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.16 no.3
    • /
    • pp.261-271
    • /
    • 2006
  • To study the correlation with increasing body fat mass for the Standard Guideline for Korean Dietary Life, a nationwide, cross-sectional survey was performed with 178 male college students in december 2005. Among the student subjects, 76 were analyzed for body protein mass, body mineral mass, body fat mass, percent body fat, waist-hip ratio(WHR), body mass index(BMI) and obesity degree using Inbody 3.0(Biospace Co, Seoul, Korea). Body protein mass was at a high level of 92.1%, body mineral mass was at a low level of 94.7%. Body fat mass was at a high level of 28.9%, percent body fat was at a high level of 37.3%, WHR was at a high level of 31.6%, and obesity degree was at a high level of 38.2%, BMI was at a high level of 24.3% and BMR was observed at a high level of 41.8%. WHR was correlated with '7. Prepare food proper amount sanitarily.' and obesity degree, while BMl was were correlated with '4. Increase movement and eat proper amount.' positively. BMR was correlated with '6. Enjoy 3 meal a day regularly.' ArmCircle was correlated with '4. Increase movement and eat proper amount.' and fitness score was corrected with '4. Increase movement and eat proper amount', and '8. Enjoy Korean rice food style.' positively. Body protein mass and body mineral mass were negatively correlated with fruit, ArmCircle was positively correlated with fish, obesity degree was positively correlated with soup and BMI and ArmCircle were positively correlated with sweet. '8. Enjoy Korean rice food style.' was negatively significantly correlated with overweight, over percentage body fat, obesity degree > 120 and BMI. Male students were not practicing the Standard Guideline for Korean Dietary Life well with an average score of 37.7%. However, male students who are within the normal range of body composition analysis value have to notice that over range of weight, protein, percentage body fat, WHI and obesity degree was observed above average score of 30%.

  • PDF

Palatal en-masse retraction of segmented maxillary anterior teeth: A finite element study

  • Park, Jae Hyun;Kook, Yoon-Ah;Kojima, Yukio;Yun, Sunock;Chae, Jong-Moon
    • The korean journal of orthodontics
    • /
    • v.49 no.3
    • /
    • pp.188-193
    • /
    • 2019
  • Objective: The aim of this finite element study was to clarify the mechanics of tooth movement in palatal en-masse retraction of segmented maxillary anterior teeth by using anchor screws and lever arms. Methods: A three-dimensional finite element method was used to simulate overall orthodontic tooth movements. The line of action of the force was varied by changing both the lever arm height and anchor screw position. Results: When the line of action of the force passed through the center of resistance (CR), the anterior teeth showed translation. However, when the line of action was not perpendicular to the long axis of the anterior teeth, the anterior teeth moved bodily with an unexpected intrusion even though the force was transmitted horizontally. To move the anterior teeth bodily without intrusion and extrusion, a downward force passing through the CR was necessary. When the line of action of the force passed apical to the CR, the anterior teeth tipped counterclockwise during retraction, and when the line of action of the force passed coronal to the CR, the anterior teeth tipped clockwise during retraction. Conclusions: The movement pattern of the anterior teeth changed depending on the combination of lever arm height and anchor screw position. However, this pattern may be unpredictable in clinical settings because the movement direction is not always equal to the force direction.