Ensuring the Evacuation Path Based on Inundation & Refuge Approach Vulnerability Analysis in Residential Buildings - Focused on Daegu Bukgu Inundation Case District - (침수 시 주거용 건축물에서 대피시설로의 접근 취약성 분석을 통한 피난경로 확보방안 - 대구시 북구 침수 사례지를 중심으로 -)

  • Lee, Ji-Soo;Hong, Won-Hwa;Kim, Gwang-Seob
    • Journal of the Korean housing association
    • /
    • v.23 no.5
    • /
    • pp.1-8
    • /
    • 2012
  • Recently, there have been frequent occurrence of the damage to lives and properties due to the torrential rain caused by climate change. In consideration of the current situations in which the underlying data related to flooding are lacking, this study conducted to build up the basic data on the flooded areas and suggested methods to secure the evacuation routes that can be accessible to evacuation facilities in the residential buildings. Methods of the study are as follows. First, We calculated the flood risk grades of residential buildings based on elevations, considering the flooding characteristics of the flooded areas in Buk-gu, Daegu. Second, We constructed baseline data on the evacuation routes through site investigation and reviewed of drawing using Arc GIS to identify vulnerability to access to the evacuation facilities, targeting the residential buildings. Third, We carried out the proximity analysis through a near analysis of analysis functions in ARC GIS. Forth, We deduced 115 residential buildings in which access to evacuation facilities is considered to be difficult based on the analysis results. Finally, We proposed extension of a blind alley as a means for achieving connectivity to evacuation facilities. And to evaluate the alternatives presented, we reconstructed route data. As a result, about 53% improvement was identified through the proximity analysis.

Study of evacuation fire doors in multiple facilities (다중이용시설의 피난방화문에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7380-7384
    • /
    • 2014
  • Evacuation fire doors were manufactured by applying phosphorescent paint to the whole fire door whose performance was already recognized, and applying heat sensitive paint around the grip. The facility was improved by the evacuation and safety functions on the fire door, which has been used as only a fire facility, and the fire door is also used as an evacuation facility. The brilliance of the evacuation safety fire door manufactured in this study passed the brilliance test of Korea Fire Institute with a performance more than the brilliance (7mcd after 60 minutes) of the existing inducement sign. During a fire, the visible area is larger than the evacuation door inducement, etc. and light preventive status in the lower part of the fire door was observed during the descent of smoke. Therefore, it is considered to extend the evacuation effective time of evacuators. In heat sensitive paint applied around the grip, a color change is observed on the fire door when approaching a certain temperature ($70^{\circ}C$). Therefore, the first disaster that evacuators can encounter on the grip of a fire door during a fire can be prevented and should be helpful in recognizing the backfiring possibility and preventing safety accidents for firefighters who must enter a fire space.

A Study on Civil Defense Evacuation Facilities (전국의 대피시설 실태조사를 통한 민방위 대피시설 표준 정립 모델 구축 연구)

  • Park, Namhee;Yeo, Wookhyun;Kim, Taewhan
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.56-70
    • /
    • 2012
  • Civil defense evacuation facilities currently installed in our country are necessary to survey the operating status. The purpose of this study is to survey on the current facility for civil defense evacuation facilities equipment, management, and problem analysis, research and to build a facility model of the standard formulation through the analysis on the actual condition of the civil defense evacuation facility. The conclusions of this study are as follows. First, the civil defense evacuation facilities are most in Seoul. Second, civil defense evacuation facilities proved to be checked periodically without a systematic management. Many facilities do not have communication facilities appear to be evacuated in an emergency situation is expected to have difficulty in contact with the outside world. Fourth, the old civil defense evacuation facilities are in the center of the metropolitan area.

Analysis of Optimal Evacuation Route for Flood Disaster (홍수재난에 대한 최적 대피경로 분석)

  • Kim, Kyong-Hoon;Park, Jae-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.2
    • /
    • pp.169-177
    • /
    • 2018
  • There is a lot of loss of life due to natural disasters. In particular, flood damage caused by heavy rainfall in urban areas causes serious damage. Therefore, in this study, we conducted a study on the optimal evacuation route for safe evacuation of urban areas. We set up a methodology by reviewing Flo-2D model and A* algorithm. A Flo-2D model was used to derive the hazardous area, and we selected the starting points with many people and suggested ways to select safe evacuation sites. And the route was derived from the starting point to the safe evacuation point by using the A * algorithm. This study could be used not only for evacuation route but also for road maintenance and evacuation facilities.

A Study on Prototype Model for Mesoscopic Evacuation Using Cube Avenue Simulation Model (Cube Avenue 시뮬레이션 모델을 이용한 중규모 재난대피 프로토타입 모델 연구)

  • Sin, Heung Gweon;Joo, Yong Jin
    • Spatial Information Research
    • /
    • v.21 no.5
    • /
    • pp.33-41
    • /
    • 2013
  • Recently, the number of disasters has been seriously increasing. The total damages by the natural or man-made disasters during the past years resulted in tremendous fatalities and recovery costs. It is necessary to have efficient emergency evacuation management which is concerned with identifying evacuation route, and the estimation of evacuation and clearance times. An emergency evacuation model is important in identifying critical locations, and developing various evacuation strategies. In that existing evacuation models have focused on route analysis for indoor evacuation, there are only a few models for areawide emergency evacuation analysis. Therefore, we developed a mesoscopic model by using Cube Avenue and performed evacuation simulation, targeting road network in City of Fargo, North Dakota. Consequently, a mesoscopic model developed in this study is used to carry out dynamic analysis using network and input variable of existing travel demand model. The results of this study show that the model is an appropriate tool for areawide emergency evacuation analysis to save time and cost. Henceforth, the results of this study can be applied to develop a disaster evacuation model which can be used for a variety of disaster simulation and evaluation based on scenarios in the local metropolitan area.

Mapping Inundation Areas by Flash Flood and Developing Rainfall Standards for Evacuation in Urban Settings (GIS를 이용한 도시지역 돌발홍수 침수예상지도 작성 및 대피강우기준 개발)

  • Shin, Sang-Young;Yeo, Chang-Geon;Baek, Chang-Hyun;Kim, Yoon-Jong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.71-80
    • /
    • 2005
  • As local flash flood exceeding planned capacity occurs frequently, localized preparedness and response to flood inundation are increasingly important. Using XP-SWMM model and GIS techniques, this study analyzes inundation areas by local flash flood and develops rainfall standards for evacuation with the case of Sadang-Cheon area, a local stream and its nearby highly populated watershed in the southern part of metropolitan Seoul, Flood inundation areas overflowed from drainage systems are analyzed and mapped by amount of rainfall that is derived from reference levels of stream flow. Rainfall standards for evacuation are comprised of 'watch' (40mm/hr) in preparing for near-future inundation and 'evacuation' (65mm/hr) in responding to realized inundation. The methods suggested by this case study may be applied to other urban areas for sound flood prevention policy measures and thus risk minimization.

  • PDF

Perception-based analytical technique of evacuation behavior under radiological emergency: An illustration of the Kori area

  • Kim, Jeongsik;Kim, Byoung-Jik;Kim, Namhun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.825-832
    • /
    • 2021
  • A simulation-based approach is proposed to study the protective actions taken by residents during nuclear emergencies using cognitive findings. Human perception-based behaviors are not heavily incorporated in the evacuation study for nuclear emergencies despite their known importance. This study proposes a generic framework of perception-based behavior simulation, in accordance with the ecological concept of affordance theory and a formal representation of affordance-based finite state automata. Based on the generic framework, a simulation model is developed to allow an evacuee to perceive available actions and execute one of them according to Newton's laws of motion. The case of a shadow evacuation under nuclear emergency is utilized to demonstrate the applicability of the proposed framework. The illustrated planning algorithm enables residents to compute not only prior knowledge of the environmental map, but also the perception of dynamic surroundings, using widely observed heuristics. The simulation results show that the temporal and spatial dynamics of the evacuation behaviors can be analyzed based on individual perception of circumstances, while utilizing the findings in cognitive science under unavoidable data restriction of nuclear emergencies. The perception-based analysis of the proposed framework is expected to enhance nuclear safety technology by complementing macroscopic analyses for advanced protective measures.

Evacuation Efficiency on School Auditorium Floor Layout (학교강당의 평면적 특징에 따른 대피효율에 관한 연구)

  • Kwun, Joon-Bum;Kim, Duk-Soo;Kim, Khil-Chae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.2
    • /
    • pp.3-10
    • /
    • 2017
  • This study compared evacuation effectiveness between the conventional school auditorium plan and a suggested hypothetical plan that was generated by a mathematical model, which is commonly applied in the field of industrial engineering. Recent school buildings became much more complicated in floor planning due to new social needs and modern curriculum than the old days. Nevertheless, architect's approach to floor composition in terms of fire emergency evacuation planning, still has no relation to optimized effective but relies more on an conventional school planning. Therefore, since school buildings are much more likely to be exposed to any fire related events than any other building types, emergency exit effectiveness based on spatial composition has to be seriously evaluated with a scientific method. The algorithm, which acquires the number of persons in each spatial type(node) per floor and the minimum physical distance between spatial types(arc), can propose the most optimized spatial layout per floor regarding emergency evacuation event. Consequently, this study evaluated school's fire exit effectiveness focusing on auditorium area with the scientific tool and suggested the most reliable spatial layout regarding possibile emergency evacuation event.

The Estimated Evacuation Time for the Emergency Planning Zone of the Kori Nuclear Site, with a Focus on the Precautionary Action Zone

  • Lee, Janghee;Jeong, Jae Jun;Shin, Wonki;Song, Eunyoung;Cho, Cheolwoo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.196-205
    • /
    • 2016
  • Background: The emergency planning zone (EPZ) of the city of Busan is divided into the precautionary actions zone (PAZ) and the urgent protective action planning zone; which have a 5-km radius and a 20-km to 21-km radius from the nuclear power plant site, respectively. In this study, we assumed that a severe accident occurred at Shin-Kori nuclear unit 3 and evaluated the dispersion speed of radiological material at each distance at various wind speeds, and estimated the effective dose equivalent and the evacuation time of PAZ residents with the goal of supporting off-site emergency action planning for the nuclear site. Materials and Methods: The total effective dose equivalent, which shows the effect of released radioactive materials on the residents, was evaluated using the RASCAL 4.2 program. In addition, a survey of 1,036 residents was performed using a standardized questionnaire, and the resident evacuation time according to road and distance was analyzed using the VISSIM 6.0 program. Results and Discussion: According to the results obtained using the VISSIM and RASCAL programs, it would take approximately 80 to 252.2 minutes for permanent residents to move out of the PAZ boundary, 40 to 197.2 minutes for students, 60 to 232.2 minutes for the infirm, such as elderly people and those in a nursing home or hospital, and 30 to 182.2 minutes for those temporarily within the area. Consequently, in the event of any delay in the evacuation, it is estimated that the residents would be exposed to up to $10mSv{\cdot}h^{-1}$ of radiation at the Exclusion Area Boundaries (EAB) boundary and $4-6mSv{\cdot}h^{-1}$ at the PAZ boundary. Conclusion: It was shown that the evacuation time for the residents is adequate in light of the time lapse from the initial moment of a severe accident to the radiation release. However, in order to minimize the evacuation time, it is necessary to maintain a system of close collaboration to avoid traffic congestion and spontaneous evacuation attempts.

A Study on the Improvement of the Refuge safety area in High-rise Buildings Type (초고층 건축물의 용도별 피난안전구역 성능확보 방안에 관한 연구)

  • Lee, Byung-Hyun;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.288-292
    • /
    • 2016
  • The purpose of this study was to improve the refuge safety area in the high-rise building type. Each simulation was conducted to evaluate the performance of three types in improving the refuge safety area. Targeting the first 63 floors (no refuge safety area), secondly, to target up to the $30^{th}$ floor (refuge safety area on the $30^{th}$ floor, $47^{th}$ floor) specified in domestic laws, and finally, the $20^{th}$ floor (evacuation safety area on the $20^{th}$ floor, $42^{th}$ floor) were considered as targets. Through this analysis, the following results were obtained : The floor for the refuge safety area through simulations showed that the evacuation time is low. It is necessary to improve the floor for the refuge safety area by using the characteristics of the domestic fire fighting vehicle. The first floor for the refuge safety area from the ground floor differs according to the distance and height of the building floor. However, in the case of a business facility it is 15F, and in the case of apartment housing, it is 20F.