• 제목/요약/키워드: Area gap

검색결과 1,086건 처리시간 0.032초

Clinical gap changes after porcelain firing cycles of zirconia fixed dentures

  • Bugurman, Bugurman Burcu;Turker, Sebnem Begum
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.177-184
    • /
    • 2014
  • PURPOSE. The aim of this study was to measure the changes on the marginal and internal adaptation of zirconia based anterior fixed partial dentures after the porcelain firing process. MATERIALS AND METHODS. A total of 34 anterior fixed partial dentures using LAVA CAD/CAM system (3M ESPE, Germany) were applied. Two silicone replicas were obtained: one is obtained before porcelain firing process (initial) and the other is obtained after porcelain firing process (final), followed by the examination under a binocular stereomicroscope. Kruskal Wallis and Wilcoxon Signed Ranks tests were used for the statistical analysis (P<.05). RESULTS. No statistically significant difference was found between initial and final marginal gap values (P>.05). At the internal gap measurements, final marginal area values ($59.54{\mu}m$) were significantly lower than the initial marginal area values ($68.68{\mu}m$)(P<.05). The highest and the lowest internal gap values were observed at the incisal/occlusal area and at the marginal area, respectively. In addition, lower internal gap values were obtained for canines than for central incisors, lateral incisors and premolars at the incisal area (P<.05). CONCLUSION. The firing cycles did not affect the marginal gap of Lava CAD/CAM system, but it is controversial for the internal gap.

Effects of Ohmic Area Etching on Buffer Breakdown Voltage of AlGaN/GaN HEMT

  • Wang, Chong;Wel, Xiao-Xiao;Zhao, Meng-Di;He, Yun-Long;Zheng, Xue-Feng;Mao, Wei;Ma, Xiao-Hua;Zhang, Jin-Cheng;Hao, Yue
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권3호
    • /
    • pp.125-128
    • /
    • 2017
  • This study is on how ohmic area etching affects the buffer breakdown voltage of AlGaN/GaN HEMT. The surface morphology of the ohmic metal can be improved by whole etching on the ohmic area. The buffer breakdown voltages of the samples with whole etching on the ohmic area were improved by the suppression of the metal spikes formed under the ohmic contact regions during high-temperature annealing. The samples with selective etching on the ohmic area were investigated for comparison. In addition, the buffer leakage currents were measured on the different radii of the wafer, and the uniformity of the buffer leakage currents on the wafer were investigated by PL mapping measurement.

Marginal and internal fit of nano-composite CAD/CAM restorations

  • Park, So-Hyun;Yoo, Yeon-Jee;Shin, Yoo-Jin;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.37-43
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods: A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU) and experimental nano-composite CAD/CAM blocks (EB) under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results: Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000). In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001). Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000). Conclusions: The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

한국 소나무림에서의 교란체제 (Disturbance Regime of the Pinus densiflora Forest in Korea)

  • Lee, Chang-Seok
    • The Korean Journal of Ecology
    • /
    • 제18권1호
    • /
    • pp.179-188
    • /
    • 1995
  • Death patterns of gap-makers and changes of environmental factors in gaps formed by disturbance were studied in Pinus densiflora forests of Youngwol, Mt, Mansu, Mt. Songni, Uljin, and Mt, Obong in Korea. Death pattern of gap-makers showed that standing deat type was the most frequent in all the study areas. Longevity of Pinus densiflora was about 140 years, which was about half of that of the temperate deciduous broad-leaved trees. size of gaps were distributed from $20m^2$ to $235m^2$, more than 80% of those were gaps created by death of two or more trees. Relative light intensity and water content of soil in gap area were higher than those in non-gap area and those in the central part of gap were the highest.

  • PDF

POOL BOILING HEAT TRANSFER IN A VERTICAL ANNULUS WITH A NARROWER UPSIDE GAP

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • 제41권10호
    • /
    • pp.1285-1292
    • /
    • 2009
  • The effects of the narrowed upside gap on nucleate pool boiling heat transfer in a vertical annulus were investigated experimentally. For the study, a stainless steel tube with a diameter of 25.4 mm and saturated water that kept an atmospheric condition were used. The ratio between the gaps measured at the upper and the lower regions of the annulus ranged from 0.18 to 1. Two different lengths of the modified gap also were investigated. The change in heat transfer due to the modified gap became evident as the gap ratio decreased and the length of the gap increased. As the gap ratio became less than 0.51, a significant decrease in heat transfer was observed compared to the plain annulus. The longer gap size resulted in an additional decrease in heat transfer. The major cause for the tendency was attributed to the formation of lumped bubbles around the upper region of the annulus followed by the increased flow friction between the fluid and the surface around the modified gap.

Design of LBSs Using DGPS and Digital Mobile Broadcasting System

  • 권성근
    • 한국위성정보통신학회논문지
    • /
    • 제8권2호
    • /
    • pp.22-28
    • /
    • 2013
  • In this paper, new LBS (location based service) are proposed using conventional DMB (digital multimedia/mobile broadcasting) system. LBS applications are proposed that can be suitable for the subway and ground transportation based on S-DMB (satellite-DMB) and T-DMB (terrestrial-DMB) respectively. In the shaded area such as subway, the broadcasting signal transmitted from the satellite of S-DMB system should be retransmitted by the earth repeater called the gap filler and each gap filler has its own identification value called the gap filler ID which introduces the area in which the gap filler was installed. Therefore, the LBS can be implemented by using the gap filler ID of S-DMB on the subway in which the GPS (global positioning system) can't be received. Unlike the LBS on the subway, the combination of T-DMB and DGPS (differential GPS) will be introduced as a way for ground transportation. Generally, DGPS has been designed to compensate the position value calculated from the GPS signal so that positioning error of about 1 meter can be obtained by using DGPS information. T-DMB system transmitting DGPS signal will be expected to be commercial in Korea and, if using DGPS information transmitted through T-DMB network, LBS with more precise positioning than GPS alone can be implemented in the ground vehicles.

GAP 농산물의 수확 후 처리에 사용되는 지하수의 위해성평가 (Risk Assessment of Groundwater Used for Washing GAP-certified Agricultural Crops after Harvest)

  • 김황용;백민경;김아름누리;이동규;정미혜;김원일;오진아;김세리;홍수명
    • 한국식품위생안전성학회지
    • /
    • 제34권6호
    • /
    • pp.551-556
    • /
    • 2019
  • 세척수에 포함된 무기물질의 함량이 먹는 물의 수질기준을 초과하여, 참외 GAP 인증을 받지 못하는 사례가 최근 들어 종종 발생하고 있다. 이에 농업현장에서는 껍질을 제거하여 먹는 참외의 소비특성을 감안하여 세척수 수질기준의 일부를 완화해 줄 것을 요청하고 있다. 이에, 본 연구에서는 성주 지역에서 2017-2019년 GAP 인증 참외의 세척에 이용되는 지하수 142건의 수질자료를 근거로 무기물질 4종(불소, 비소, 철, 망간)의 인체 위해성을 평가하였다. 연구 결과, 성주 지역 GAP 참외의 세척에 사용되는 지하수를 음용수 수준으로 섭취하는 우리나라 국민의 4종 무기물질에 대한 HQ는 모두 평균 0.10 이하로 안전한 수준이었다. 특히, 심미적 영향물질인 철, 망간의 경우 성주 지역 지하수를 음용수 수준으로 섭취하는 경우 HQ가 평균 0.00. 과다노출군의 경우 0.01나타났는데, 일반 참외를 섭취하는 국민의 HQ(평균 0.01, 과다노출군 0.03)보다 낮은 수준이었다. 따라서, 성주 지역 지하수를 GAP 농산물의 세척에 활용하더라도 철, 망간을 포함한 4종 무기물질이 인체에 미치는 영향은 미미할 것으로 생각된다.

소나무 묘목(苗木)의 Gap내 생장(生長) 및 생리적(生理的) 적응과정(適應過程) (Growth Characteristics and Physiological Adaptation of Pinus densiflora Seedling in the Canopy Gap)

  • 김영환;이돈구
    • 한국산림과학회지
    • /
    • 제89권3호
    • /
    • pp.452-460
    • /
    • 2000
  • 본 연구에서는 Gap 갱신이 이루어지는 소나무를 대상으로 인위적으로 조성한 Gap처리구에서 소나무 묘목의 생장 및 광도의 변화에 따른 광합성속도, 중산속도 등 생리적 특성의 변화를 분석하고 Gap 생장환경에 대한 소나무 묘목의 적응과정에 대한 연구를 통해 갱신기작을 구명하고자 하였다. Open된 생장환경에 비해 광도가 낮고 광질이 다른 Gap처리구에서 소나무 묘목은 근원경보다는 상대적으로 묘고의 생장량이 더 많이 이루어졌고 건중량의 증가비율도 지하부보다는 지상부에서 상대적으로 크게 나타나 비교적 높은 T/R율을 보였다. 소나무 묘목의 지상부 C/F비율(지상부의 비동화기관과 동화기관 건중량의 비율)도 Gap처리구에서는 Open 생장환경에 비해 0.1~0.2정도 높았으며 광포화점은 $300{\mu}mol\;m^{-2}s^{-1}$정도 낮았고 광보상점도 40%정도 낮게 나타나 양수이지만 내음성을 나타내었다. 또한 광도가 $400{\sim}450{\mu}mol\;m^{-2}s^{-1}$보다 낮을 때 소나무 묘목은 비교적 높은 광합성속도와 수분이용효율을 나타내었으며 약한 광에너지를 효율적으로 이용하였다.

  • PDF

스테인레스강에 대한 전자빔용접과 협개선TIG 용접수축량 비교 (The comparison of weld shrinkage between Electron beam welding and Narrow-gap TIG welding for stainless steel)

  • 김용재;정원회;심덕남;정인철
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 추계학술발표대회 개요집
    • /
    • pp.76-78
    • /
    • 2004
  • The phenomenon of weld shrinkage mainly occurs owing to residual stress by heating, which largely effects on welding quality, Actually as the shrinkage rate depends on the weld deposit amount, so it is desired that the sectional area of weld joint shall be reduced. In this respect the Electron beam welding has more profitable position compare to Narrow-gap TIG welding which is even superior to other arc welding processes. In case of thick austenitic stainless steel the shrinkage rate of Electron beam welding has about $10\%$ of Narrow-gap TIG welding's, which means that residual stress is a lot less than that of Narrow-gap TIG welding. And heat input and welded section area also indicate large difference between two processes.

  • PDF

IPS 모드를 이용한 반투과형 액정 디스플레이 (Transflective Liquid Crystal Display using In-Plane Switching Mode)

  • 송제훈;임영진;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.153-156
    • /
    • 2004
  • We have studied electro-optic characteristics of transflective liquid crystal display (LCD) using in-plane switching mode. Unlike previous transflective LCD using a dual gap structure and multi driving circuit, this transflective LCD has a single gap structure and a single driving circuit. In the voltage on state, the electric field is applied horizontally to the LC directors, and then homogeneously aligned LC directors at initial state is rotated to with the electric field. But the twist angle of the LC directors in reflective area is lower than transmissive area. As a result, it is possible to design the transflective LCD with a single gap and a single driving circuit. The transflective display associated with this LC cell exhibits a wide viewing angle in both reflective and transmissive areas.

  • PDF