• 제목/요약/키워드: Area estimation

검색결과 3,317건 처리시간 0.036초

방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(3) - 시험 및 평가방법의 제안 - (Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(3) - Suggestion of Test and Estimation Method -)

  • 김철환;장태순;강희만;전기성;김동준;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.496-499
    • /
    • 2008
  • The noise reducing devices installed on the noise barrier have been developed in many shapes and ways to reduce noise around road traffic areas. In this study, test and estimation method for the noise reducing device witch installed on the top of a noise barrier was suggested. For this, the authors have considered sound power flow around the device and sound pressure levels for the far field area. To estimate the area effect behind the barrier, area average of noise pressure level difference divided by two area, upper and bellow the sight-line. Comparing the attenuation difference of these areas, the tendency of noise reduction effect was studied according to type of noise reducing devices. Compared with noise shielding efficiency of the devices that using equivalent height of a simple barrier calculated by the SoundPlan, the commercial environment noise simulation software.

  • PDF

대구시 대기오염물질 배출량 산정에 관한 연구 (Emission Estimation of Air Pollutants in Daegu)

  • 박명희;김해동;홍정혜
    • 한국환경과학회지
    • /
    • 제12권1호
    • /
    • pp.23-34
    • /
    • 2003
  • Urban air quality is usually worse than that of rural counterpart. The contrasting atmospheric properties seem to be direct result of different urban-rural air pollutant emission. Hence, the emission estimation of air pollutants plays an important role to the atmospheric environmental management. The main purpose of this study is to find out the temporal and spatial distribution of air pollutant emission in Daegu area. For the study, the Daegu statistical yearbook and data of waste facilities and the report on traffic survey issued by Daegu metropolitan city and the statistical yearbook on the road capacity issued by the ministry of construction and transportation are used. Each item for the emission estimation is $SO_2$, CO, HC, $NO_x$, PM-10 from point, line and area source. The result were as follow; (1) The air pollutants with the highest amount of emission from the emission source is CO followed by $NO_x$, $SO_2$, PM-10, HC in descending order of magnitude. (2) The annually totaled air pollutant emission consists of 81%(73,185 ton/year) of line, 11%(9,589% ton/year) of area and 8%(7,445 ton/year) of point source in Daegu. Air polluant emission was mainly due to line sources. (3) High-emission of the air pollutants of line source appeared ariond Bukgu, Dalseonggun, Dongu and Seogu ; the areas with highway networks.

단순회귀분석에 의한 토층지반의 투수계수 산정모델 (Estimation model of coefficient of permeability of soil layer using linear regression analysis)

  • 이문세;김경수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.1043-1052
    • /
    • 2009
  • To derive easily the coefficient of permeability from several other soil properties, the estimation model of coefficient of permeability was proposed using linear regression analysis. The coefficient of permeability is one of the major factors to evaluate the soil characteristics. The study area is located in Kangwon-do Pyeongchang-gun Jinbu-Myeon. Soil samples of 45 spots were taken from the study area and various soil tests were carried out in laboratory. After selecting the soil factor influenced by the coefficient of permeability through the correlation analysis, the estimation model of coefficient of permeability was developed using the linear regression analysis between the selected soil factor and the coefficient of permeability from permeability test. Also, the estimation model of coefficient of permeability was compared with the results from permeability test and empirical equation, and the suitability of proposed model was proved. As the result of correlation analysis between various soil factors and the coefficient of permeability using SPSS(statistical package for the social sciences), the largest influence factor of coefficient of permeability were the effective grain size, porosity and dry unit weight. The coefficient of permeability calculated from the proposed model was similar to that resulted from permeability test. Therefore, the proposed model can be used in case of estimating the coefficient of permeability at the same soil condition like study area.

  • PDF

공동주택 난방방식별 전력에너지 소비량 추정모델 작성 연구 (A Study on the Estimation model of the Amount of the Electric Energy Consumption according to the Apartment Heating Type)

  • 이강희;양재혁;유우상
    • KIEAE Journal
    • /
    • 제10권1호
    • /
    • pp.57-64
    • /
    • 2010
  • Electric energy is indispensible of the development of the industrial and living sector. Among the energy sectors, the building area shares 20% of the produced electric power in Korea. As we plan to supply the apartment, we need to forecast the required amount of the electric energy and supply the infrastructure to apartment for the lighting, cooling. Nonetheless, it is not easy to forecast the required amount of the electric energy, considering the management aspect, building physical aspect and social-geographic aspect. In this paper, it studied the estimation model of the electric energy, reflecting the affecting variables such as total area, number of household, geography and so on. The estimation model is proposed in 3-types which explained in central heating, individual heating and district heating, and each type have two estimation model, reflecting the affecting variable and corelation between variables to eliminate the muticolinearity. The unit of electric energy consumption per area and year is similar in three heating type and the results are as follows; the central heating is $34.446kWh/yr{\cdot}m^2$, individual type is $35.756446kWh/yr{\cdot}m^2$ and district heating is $34.285446kWh/yr{\cdot}m^2$.

IMPERVIOUS SURFACE ESTIMATION USING REMOTE SENSING IMAGES AND TREE REGRESSIOIN

  • Kim, Soo-Young;Kim, Jong-Hong;Heo, Joon;Heo, Jun-Haeng
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.239-242
    • /
    • 2006
  • Impervious surface is an important index for the estimation of urbanization and environmental change. In addition, impervious surface has an influence on the parameters of rainfall-runoff model during rainy season. The increase of impervious surface causes peak discharge increasing and fast concentration time in urban area. Accordingly, impervious surface estimation is an important factor of urban rainfall-runoff model development and calibration. In this study, impervious surface estimation is performed by using remote sensing images such as landsat-7 ETM+ and high resolution satellite image and regression tree algorithm based on case study area ? Jungnang-cheon basin in Korea.

  • PDF

다중 센서들을 이용한 다양한 화재 상황의 위험도 추정 시스템 개발 (Implementation of Fire Risk Estimation System for various Fire Situations using Multiple Sensors)

  • 이광재;이연성
    • 센서학회지
    • /
    • 제25권6호
    • /
    • pp.394-398
    • /
    • 2016
  • In this paper, a fire detection system based on quantitative risk estimation is presented. Multiple sensors are used to build a comprehensive indicator that represents the risk of fire quantitatively. The proposed fire risk estimation method consists of two stages which determines the occurrence of fire and estimates the toxicity of the surveillance area. In the first stage, fire is reliably detected under diverse fire scenarios. The risk of fire is estimated in the second stage. Applying Purser's Fractional Effective Dose (FED) model which quantitates harmfulness of toxic gases, the risk of the surveillance area and evacuation time are calculated. A fire experiment conducted using four different types of combustion materials for the verification of the system resulted in a maximum error rate of 12.5%. By using FED calculation and risk estimation methods, the proposed system can detect various signs of fire faster than conventional systems.

경안천수계에 있어서 수서곤충에 의한 생물학적 수질평가 (A Study on the Biological Estimation of Water Pollution Levels by the Aquatic Insects in Kyungan Stream, Kyunggi-Do)

  • 배경석;이상수;신도철;이용진;김진곤;오수경
    • 한국환경보건학회지
    • /
    • 제16권2호
    • /
    • pp.63-74
    • /
    • 1990
  • The present study was accomplished from March to August, 1990 in order to examine the community structure of aquatic insects and the biological estimation of water pollution levels by the aquatic inseets of Kyungan stream in Kyunggi-do. 1. The aquatic inseets of whole area composed of 78 species, 42 genera, 26 families in 8 roders. 2. The occurrence species number show highest at Gungpyung-ri(29 species) and lowest at Yongin town(1 species) 3. Dominance indices show lowest at Gungpyung-ri(0.35) and highest at Yongin town(1.00) and Choboo-ri(1.00) 4. Species diversity indices show highest at Gungpyung-ri(3.53) and lowest at Yongin town(0.00) 5. The biological estimation of each area's water quality levels based on the diversity index are as follows. Oligosaprobic area : Gungpyung-ri, Muchu-ri $\alpha$ mesosaprobic area : Yooeun-ri, Choboo-ri(K4), upper site of Wangsanri, Yeuk-ri, Wangsan-ri. $\beta$ mesosaprobic area Gonjiam-ri, Dopyoung-ri, Kyungan-ri, Wondang-ri. Polysaprobic area : Yongin town, Choboo-ri(K5)

  • PDF

중.고등학교 남녀학생의 기술.가정 교과 활용도와 선호도 평가에 따른 단원 분류 및 성별 차이 분석 - 춘천시를 중심으로 - (The Unit Classification and Gender-Difference Analysis of Technology.Home Economics Subject Based on Estimation of the Degree of Practical Use and Preference among Male and Female Middle.High School Students in Chuncheon city')

  • 전경숙;최동숙
    • 한국가정과교육학회지
    • /
    • 제19권3호
    • /
    • pp.91-106
    • /
    • 2007
  • The purpose of this study was to provide the information for the development of gender-equality oriented content of Technology Home Economics subject. For this purpose, a total of 404 male and female middle high school students in Chuncheon city were sampled and asked to estimate the degree of practical use and preference for the 47 units of Technology Home Economics subject. Results were summarized as following : 1. The 47 units were classified into 4 groups on the basis of similarity in the degree of practical use and preference: 23 units estimated as 'better than average' by male and female students were classified into group 1; 4 units estimated as 'better than average' by female students but as 'less than average' by male students were classified into group 2; 10 units estimated as 'less than average' by male and female students were classified into group. 3; 10 units estimated as 'far less than average' by male and female students were classified into group 4. Most of the units in Home Economics area were classified Into group 1 or 2, but most of the units in Technology area were classified into group 3 or 4. 2. Gender difference was confirmed between male and female students' estimation of the degree of practical use and preference for the 47 units. In about three-quaters of the units in Home Economics area, female students' estimation of the degree of practical use and preference was higher than male students' estimation. In about half of the units in Technology area, male students' estimation of the degree of practical use and preference was higher than female students' estimation. However, possibility was detected in several units of Technology Home Economics subject that gender difference could be decreased.

  • PDF

공동주택 사용부문의 이산화탄소 배출량 추정모델 연구 (Estimation Model of the Carbon Dioxide Emission in the Apartment Housing During the Maintenance period)

  • 이강희;채창우
    • KIEAE Journal
    • /
    • 제8권4호
    • /
    • pp.19-27
    • /
    • 2008
  • The carbon dioxide is brought from the energy consumption and regarded as a criteria material to estimate the Global Warming Potential. Building shares about 30% in national energy consumption and affects to environment as much as the energy consumption. But there is not enough data to forecast the amount of the carbon dioxide during the maintenance stage. Various factors are related with the energy consumption and carbon dioxide emission such as the physical area, the building exterior area, the maintenance type and location. Among these factors, the building carbon-dioxide emission can be estimated by the overall building characteristics such as the maintenance area, the number of household, the heating type, etc., The physical amount such as the thickness of the insulation and window infiltration could explained the limited scope and might not be use to estimate the total carbon-dioxide emission energy because the each value could not include or represent the overall building. In this paper, it provided the estimation model of the carbon-dioxide emission, explained by the overall building characteristics. These factors are shown as the maintenance area, no. of household, the heating type, the volume of the building, the ratio of the window to wall area etc., For providing the estimation model of th carbon-dioxide emission, it conducted the corelation analysis to filter the variables and suggested the estimation model with the power model and multiple regression model. Most of the model have a good statistics and fitted in the curve line.

Stream flow estimation in small to large size streams using Sentinel-1 Synthetic Aperture Radar (SAR) data in Han River Basin, Korea

  • Ahmad, Waqas;Kim, Dongkyun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.152-152
    • /
    • 2019
  • This study demonstrates a novel approach of remotely sensed estimates of stream flow at fifteen hydrological station in the Han River Basin, Korea. Multi-temporal data of the European Space Agency's Sentinel-1 SAR satellite from 19 January, 2015 to 25 August, 2018 is used to develop and validate the flow estimation model for each station. The flow estimation model is based on a power law relationship established between the remotely sensed surface area of water at a selected reach of the stream and the observed discharge. The satellite images were pre-processed for thermal noise, radiometric, speckle and terrain correction. The difference in SAR image brightness caused by the differences in SAR satellite look angle and atmospheric condition are corrected using the histogram matching technique. Selective area filtering is applied to identify the extent of the selected stream reach where the change in water surface area is highly sensitive to the change in stream discharge. Following this, an iterative procedure called the Optimum Threshold Classification Algorithm (OTC) is applied to the multi-temporal selective areas to extract a series of water surface areas. It is observed that the extracted water surface area and the stream discharge are related by the power law equation. A strong correlation coefficient ranging from 0.68 to 0.98 (mean=0.89) was observed for thirteen hydrological stations, while at two stations the relationship was highly affected by the hydraulic structures such as dam. It is further identified that the availability of remotely sensed data for a range of discharge conditions and the geometric properties of the selected stream reach such as the stream width and side slope influence the accuracy of the flow estimation model.

  • PDF