• Title/Summary/Keyword: Area Error

Search Result 2,400, Processing Time 0.029 seconds

Aerodynamic Characteristics Analysis of Small Two-Stage Turbo Blower Using CFD (CFD를 이용한 소형 2단 터보블로워의 공력해석)

  • Seo, Seungjae;Ryu, Minhyoung;Cho, Leesang;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.4
    • /
    • pp.326-335
    • /
    • 2014
  • Aerodynamic characteristics of the small two-stage turbo blower were investigated using commercial CFD tool(ANSYS CFX Ver. 14.5) in this paper. Turbo blower, which is a centrifugal type of turbomachinery, is used in various industries. It is used for application that required high static pressure rising at relatively small volumetric flow rate. In order to understand the mechanism of static pressure rising, the aerodynamic characteristics of the small two-stage turbo blower are analyzed at high rotating speed in this study. The k-${\omega}$ SST turbulence model, which is good at prediction of adverse pressure gradient flows, was applied. The CFD results of the turbo blower are validated by performance test. The static pressure rising of the turbo blower is nonlinearly increased over the first stage and the second stage. The secondary flow occurred at guide vanes, between the casing and the first impeller shroud, and the bottom of the impeller disk. As a result, It is required that whole fluid area is analyzed to predict aerodynamic characteristics of small two-stage turbo blower. and the result should be selected with considering for error from experiment and CFD.

Voting-based Intra Mode Bit Skip Using Pixel Information in Neighbor Blocks (이웃한 블록 내 화소 정보를 이용한 투표 결정 기반의 인트라 예측 모드 부호화 생략 방법)

  • Kim, Ji-Eon;Cho, Hye-Jeong;Jeong, Se-Yoon;Lee, Jin-Ho;Oh, Seoung-Jun
    • Journal of Broadcast Engineering
    • /
    • v.15 no.4
    • /
    • pp.498-512
    • /
    • 2010
  • Intra coding is an indispensable coding tool since it can provide random accessibility as well as error resiliency. However, it is the problem that intra coding has relatively low coding efficiency compared with inter coding in the area of video coding. Even though H.264/AVC has significantly improved the intra coding performance compared with previous video standards, H.264/AVC encoder complexity is significantly increased, which is not suitable for low bit rate interactive services. In this paper, a Voting-based Intra Mode Bit Skip (V-IMBS) scheme is proposed to improve coding efficiency as well as to reduce encoding time complexity using decoder-side prediction. In case that the decoder can determine the same prediction mode as what is chosen by the encoder, the encoder does not send that intra prediction mode; otherwise, the conventional H.264/AVC intra coding is performed. Simulation results reveal a performance increase up to 4.44% overall rate savings and 0.24 dB in peak signal-to-noise ratio while the frame encoding speed of proposed method is about 42.8% better than that of H.264/AVC.

Performance Analysis of Noncoherent OOK UWB Transceiver for LR-WPAN (저속 WPAN용 비동기 OOK 방식 UWB 송수신기 성능 분석)

  • Ki Myoungoh;Choi Sungsoo;Oh Hui-Myoung;Kim Kwan-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.11A
    • /
    • pp.1027-1034
    • /
    • 2005
  • IEEE802.15.4a, which is started to realize the PHY layer including high precision ranging/positioning and low data rate communication functions, requires a simple and low power consumable transceiver architecture. To satisfy this requirements, the simple noncoherent on-off keying (OOK) UWB transceiver with the parallel energy window banks (PEWB) giving high precision signal processing interface is proposed. The flexibility of the proposed system in multipath fading channel environments is acquired with the pulse and bit repetition method. To analyze the bit error rate (BER) performance of this proposed system, a noise model in receiver is derived with commonly used random variable distribution, chi-square. BER of $10^{-5}$ under the line-of-sight (LOS) residential channel is achieved with the integration time of 32 ns and signal to noise ratio (SNR) of 15.3 dB. For the non-line-of-sight (NLOS) outdoor channel, the integration time of 72 ns and SNR of 16.2 dB are needed. The integrated energy to total received energy (IRR) for the best BER performance is about $86\%$.

Calibration and Validation of HSPF Mode1 to Estimate the Pollutant Loads from Rural Small Watershed (농촌소유역의 오염부하 추정을 위한 HSPF 모형의 보정과 검정)

  • Kim, Sang-Min;Park, Seung-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.8
    • /
    • pp.643-651
    • /
    • 2004
  • In this paper, the Hydrologic Simulation Program-Fortran (HSPF) was validated to estimate the pollutant loads from rural small watershed. The study watershed was the HP#6 subwatershed in Balhan reservoir watershed, located southwest from Suwon. The drainage area of HP#6 study watershed was 3.85$\textrm{km}^2$. Parameters of the HSPF model related to hydrology and water quality were calibrated from 1996 to 1997, and validated from 1999 to 2000 using observed hydrologic and water quality data. The average simulated runoff ratio for the calibration period was 0.579 and the measured runoff ratio was 0.583. The root mean square error (RMSE) for runoff during the calibration period was 2.1mm and correlation coefficient ($R^2$) was 0.92. Regarding the total nitrogen simulation, the RMSE was 0.086kg/ha/day and $R^2$ was 0.81 for the calibration period. In the case of total phosphorus, the RMSE was 0.012kg/ha/day and $R^2$ was 0.70 for the calibration period.

A Study on the Estimation of Energy Expenditure and falls measurement system for the elderly (고령자를 위한 에너지 소비 추정 및 낙상 측정 시스템에 관한 연구)

  • Lim, Chae-Young;Jeon, Ki-Man;Ko, Kwang-Cheol;Koh, Kwang-Nak;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • As we are turnning into the aged society, accidents by falling down are increasing in the aged people's group. In this paper, we design the system with the 3-Axis acceleration sensor which is composed by a single chip. The body activity signal is measured with the signal detector and RF communicator in this proposed system and the and falling by the entering signal pattern analysis with 3-Axis acceleration sensor. For the RF communication, we are using nRF24L01p and 8bits ATmega uC for the processor. The error of energy expenditure estimation between motor driven treadmill and proposed a body activity module was 7.8% respectively. Human activities and falling is monitored according to analyze and judge the critical value of the Signal Vector. as falled down if they don't turn off the alarm after specific period and the aged person's after falling down activities are their position and more.

Application of Very Short-Term Rainfall Forecasting to Urban Water Simulation using TREC Method (TREC기법을 이용한 초단기 레이더 강우예측의 도시유출 모의 적용)

  • Kim, Jong Pil;Yoon, Sun Kwon;Kim, Gwangseob;Moon, Young Il
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.5
    • /
    • pp.409-423
    • /
    • 2015
  • In this study the very short-term rainfall forecasting and storm water forecasting using the weather radar data were implemented in an urban stream basin. As forecasting time increasing, the very short-term rainfall forecasting results show that the correlation coefficient was decreased and the root mean square error was increased and then the forecasting model accuracy was decreased. However, as a result of the correlation coefficient up to 60-minute forecasting time is maintained 0.5 or higher was obtained. As a result of storm water forecasting in an urban area, the reduction in peak flow and outflow volume with increasing forecasting time occurs, the peak time was analyzed that relatively matched. In the application of storm water forecasting by radar rainfall forecast, the errors has occurred that we determined some of the external factors. In the future, we believed to be necessary to perform that the continuous algorithm improvement such as simulation of rapid generation and disappearance phenomenon by precipitation echo, the improvement of extreme rainfall forecasting in urban areas, and the rainfall-runoff model parameter optimizations. The results of this study, not only urban stream basin, but also we obtained the observed data, and expand the real-time flood alarm system over the ungaged basins. In addition, it is possible to take advantage of development of as multi-sensor based very short-term rainfall forecasting technology.

Accuracy Analysis of Velocity and Water Depth Measurement in the Straight Channel using ADCP (ADCP를 이용한 직선 하천의 유속 및 수심 측정 정확도 분석)

  • Kim, Jongmin;Kim, Dongsu;Son, Geunsoo;Kim, Seojun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.5
    • /
    • pp.367-377
    • /
    • 2015
  • ADCPs have been highlighted so far for measuring steramflow discharge in terms of their high-order of accuracy, relatively low cost and less field operators driven by their easy in-situ operation. While ADCPs become increasingly dominant in hydrometric area, their actual measurement accuracy for velocity and bathymetry measurement has not been sufficiently validated due to the lack of reliable bench-mark data, and subsequently there are still many uncertain aspects for using ADCPs in the field. This research aimed at analyzing inter-comparison results between ADCP measurements with respect to the detailed ADV measurement in a specified field environment. Overall, 184 ADV points were collected for densely designed grids for the given cross-section that has 6 m of width, 1 m of depth, and 0.7 m/s of averaged mean flow velocity. Concurrently, ADCP fixed-points measurements were conducted for each 0.2m and 0.02m of horizontal and vertical spacing respectively. The inter-comparison results indicated that ADCP matched ADV velocity very accurately for 0.4~0.8 of relative depth (y/h), but noticeable deviation occurred between them in near surface and bottom region. For evaluating the capacity of measuring bathymetry of ADCPs, bottom tracking bathymetry based on oblique beams showed better performance than vertical beam approach, and similar results were shown for fixed and moving-boat method as well. Error analysis for velocity and bathymetry measurements of ADCP can be potentially able to be utilized for the more detailed uncertainty analysis of the ADCP discharge measurement.

The Rearch Of Method in the Appropriate number of Demand and Supply of OMD (한의사인력(韓醫師人力) 공급(供給)의 적정화방안(適定化方案) 연구(硏究))

  • Lee, Jong-Soo
    • The Journal of Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.299-326
    • /
    • 1998
  • 1. Comparison of demand and supply A. Assumption of estimation of demand and supply we will briefly assumptions used for presumption once more before comparing the result of estimation of demand and supply examined previously 1) supply - The average applying rate for state. examination of graduate: ${\alpha}$=1.03109 - The ratio of successful applicants of state examinations: ${\beta}$=0.97091 - Mortality classified by age : presumed data of the Bureau of statistics - Emigrating rate: 0 % - Time of retire: unconsidered - An army doctor number: unconsidered and regard number of employed oriental medicine doctor. - Standard of 1995 : The number of survival oriental medicine doctor is 8195. the number of employed oriental medicine doctor is 7419. 2) demand - derivated demand method Daily the average amount of medical treatment: according to medical insurance federation data. there is 16 or 6 non allowance patient, we consider amount of medical treatment as 22 persons in practical because 21.94 persons (founded practical examination) are converted to allowance in comming demand. Daily the proper amount of medical treatment: 7 hours form -35 persons 5 hours 30 minutes form -28 persons. Yearly medical treatment days: 229 days. 255 days. 269 days . Increasing rate of visiting hospital days: -1996 year. 1997 year. 1998 year- . Rate of applying insurance: yearly average 71.51% (among the investigated patient) B. Comparison of total sum result 1) supply (provision) Table Ⅳ-1 below shows the estimation of the oriental medicine doctor in the future.

  • PDF
  • Numerical Interpolation on the Simulation of Air Flow Field and the Effect of Data Quality Control in Complex Terrain (객관 분석에 의한 복잡지형의 대기유동장 수치모의와 모델에 의한 자료질 조절효과)

    • Lee Hwa woon;Choi Hyun-Jung;Lee Kang-Yoel
      • Journal of Korean Society for Atmospheric Environment
      • /
      • v.21 no.1
      • /
      • pp.97-105
      • /
      • 2005
    • In order to reduce the uncertainties and improve the air flow field, objective analysis using asynoptic observational data is chosen as a method that enhances the reality of meteorology. In surficial data and their numerical interpolation for improving the interpretation of meteorological components, objective analysis scheme should perform a smooth interpolation, detect and remove the bad data and carry out internal consistency analysis. For objective analysis technique which related to data reliability and error suppression, we carried out two quality control methods. In site quality control, asynoptic observational data at urban area revealed low representation by the complex terrain and buildings. In case of wind field, it was more effective than temperature field when it were interpolated near waterbody data. Many roads, buildings, subways, vehicles are bring about artificial heat which left out of consideration on the simulation of air flow field. Therefore, in temperature field, objective analysis for more effective result was obtained when surficial data were interpolated as many as possible using value quality control rather than the selection of representative site.

    Distribution of Natural Frequency of 2-DOF Approximate Model of Stay Cable to Reduction of Area (단면감소에 따른 사장케이블의 2-자유도 근사모델의 고유진동수 분포)

    • Joe, Yang-Hee;Lee, Hyun-Chol
      • Journal of the Korea institute for structural maintenance and inspection
      • /
      • v.18 no.6
      • /
      • pp.147-154
      • /
      • 2014
    • The cable damages of the bridge structures induce very important impact on the structural safety, which implies the close monitoring of the cable damage is required to secure sustained safety of the bridges. Most usual available maintenance techniques are based on the monitoring the change of the natural frequency of the structures by damages. However, existing method are based on vibration method to calculate lateral vibration and system identification can calculate the axial stiffness using sensitivity equation by trial error method. But the frequency study by the longitudinal movement need because of the sag effect in system identification. This study proposes a new method to investigate the damage magnitudes and status. The method improves the accuracies in the magnitudes and status of damages by adopting the natural frequency of longitudinal movement. The study results have been validated by comparing them with the approximate solution of FEM. Thus, the relationship of cable damage and frequency appear with relation that the severe damage has the little frequency. If we know the real frequency we can estimate the cable damage severity using this relationship. This method can be possible the efficient management of the cable damage.


    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.