• 제목/요약/키워드: Area Efficiency

검색결과 4,838건 처리시간 0.033초

Eco-efficiency Analysis of Urban Agglomeration in the Middle Reaches of the Yangtze River

  • Chen, Minghui;Miao, Jianjun
    • 산경연구논집
    • /
    • 제10권1호
    • /
    • pp.9-17
    • /
    • 2019
  • Purpose - Urban agglomeration construction is one of national strategic plans to accelerate the development of industrialization and urbanization in China, which has threatened the eco-environmental quality at the same time. This paper selected the urban agglomeration in the middle reaches of the Yangtze River as the research area. Research design, data, and methodology - The the slack-based measurement (SBM) model considering undesirable outputs is applied to measure the eco-efficiency of this urban agglomerations during 2006-2015. Results - The empirical results show that average eco-efficiency of the urban agglomeration in the middle reaches of the Yangtze River is 0.595. Regional ecological development is unbalanced. The highest eco-efficiency is recorded at Wuhan Metropolitan Area, and the lowest one is at the Changsha-Zhuzhou-Xiangtan City Group. Energy consumption and waste dust emissions are the key factors led to ecological inefficiency. Based on this, potentials for energy saving and waste dust reducing are calculated. Conclusions - Finally, this study provides policy implications targeted to promote the coordinating development of economy and eco-environment under the construction of urban agglomeration.

렌즈에서 UV 차단효과의 평가방법 및 적용 (The Estimation Method and Application of UV-cut effect in Lens)

  • 김용근
    • 한국안광학회지
    • /
    • 제6권1호
    • /
    • pp.107-110
    • /
    • 2001
  • 렌즈에서 UV-A선의 차단효율을 평가하기 위해 320~400nm 영역에서 광 투과율을 측정하였다. 기준 CR-39와 sample을 320~400nm 영역에서 광 투과율을 적분하여 면적을 구하였으며, 이들의 면적 대비로 UV-A 차단효율 factor ${\alpha}$, ${\beta}$를 설정하였다. CR-39 렌즈의 질대 차단효율 ${\alpha}$ CR=0.59 값을 얻었다. UV-A 차단효과를 평가할 렌즈의 절대차단효율 ${\alpha}$ 값이면 상대차단효율 ${\beta}$ 값은 $1.69{\alpha}$ 값을 얻었다. 절대적 및 상대적 UV 제거 지수는 각각 $a=(1-{\alpha}){\times}100%$, $b=(1-{\beta}){\times}100%$을 이용하여 얻었다.

  • PDF

국내공항 관제탑의 상대적 효율성에 관한 연구 (A Study on the relative Efficiency of ATC Towers in Domestic Airports)

  • 김도현
    • 한국항공운항학회지
    • /
    • 제11권2호
    • /
    • pp.59-77
    • /
    • 2003
  • Air Traffic Control Tower is one of the most important units in Airport operation. It provides services related to safe and efficient traffic flows that control aircraft on the ground maneuvering area and terminal airspace. Also It is responsible for managing of ground operators. The major objective of this study is to evaluates relative efficiency of ATC towers in Domestic airports using data envelopment analysis so that it helps the ATC authority to improve the tower efficiency, to decide the level of benchmarking target and to establish the best alternative. The results of this study are the following; First, as a result of analysis for the potential improvement, it has analysed that the common problems of each ATC tower are to increase its number of flight and to reduce its number of runway followed by airside area, the number of air traffic controller and the number of stand. Second, it has shown that the each tower in RKPC(8), RKPT(5), RKPK(l) and RKSS(l) are used as the reference set. Especially, the tower in RKPC analyzed as a relatively efficient unit is the most main target for the towers in RKTU, RKTH, RKPS and RKTY to do bench marking and to set up the strategy for improving relative efficiency of the tower. Third, tower is actually not able to control the input and output data in this study except the number of controller, so that ATC authority is recommended to improve inefficiency of the towers through handling the number of controller.

  • PDF

다양한 해상도의 초음파 영상처리를 위한 매니코어 프로세서의 디자인 공간 탐색 (Design Space Exploration of Many-Core Processors for Ultrasonic Image Processing at Different Resolutions)

  • 강성모;김종면
    • 정보처리학회논문지A
    • /
    • 제19A권3호
    • /
    • pp.121-128
    • /
    • 2012
  • 본 논문은 다양한 해상도에서의 초음파 영상 처리를 위한 최적의 프로세싱 엘리먼트 구조를 제안한다. 이를 위해 본 논문에서는 각 프로세싱 엘리먼트(processing element, PE)당 처리되는 영상 데이터(data-per-processing element, DPE) 수를 변화시키는 실험을 통해 시스템의 성능(system performance), 에너지 효율(energy efficiency), 면적 효율(area efficiency)을 각각 측정하고, 측정된 결과를 바탕으로 최적의 매니코어 프로세서 구조를 선택하였다. 모의실험 결과, 에너지 효율은 $256{\times}256$, $768{\times}1,024$, $1,024{\times}1,280$ 해상도를 갖는 영상에서 PE 개수가 각각 1,024개, 4,096개, 16,384개일 때 가장 높았다. 또한 면적 효율은 $256{\times}256$ 해상도의 영상에서는 PE 개수가 256개, $768{\times}1,024$$1,024{\times}1,280$ 해상도의 영상에서는 4,096개에서 가장 높은 효율을 보였다.

설계인자 변화에 따른 소형 전기집진장치의 최적효율 예측 (Predicted Optimum Efficiency due to Changes in the Design Parameters of the Small Electrostatic Precipitator)

  • 서정민;이병인;정문섭;박정호;임우택;박출재;최금찬
    • 한국환경과학회지
    • /
    • 제22권9호
    • /
    • pp.1187-1197
    • /
    • 2013
  • The result of a small electrostatic precipitator which is in order to decrease indoor air pollution for optimal efficiency was shown as follows. Although the closer distance between the discharge electrode and dust collecting electrode shows the better throughput efficiency by forming strong electrostatic Field, it does not have profound impact in case of optimal dust collecting area. G.P(gas passage) which is the distance from dust collecting electrode to dust collecting electrode is a crucial factor to decide dust collecting efficiency. The narrower distance of G.P shows the better throughput efficiency whereas it decreases when the distance is too narrow since sparks ensue by increasing the capacity of electrostatic charging system 5 mm regards as optimal efficiency in this experiment. Although the higher voltage shows the higher dust collecting efficiency overall, the experiment was not able to keep performing since the sparks which decrease dust collecting efficiency ensue over 40 kV. The efficient and safe voltage state is considered 3.6 kV in this experiment. The most crucial factor for dust collecting efficiency of an electrostatic precipitator which is in order to decrease indoor air pollution is applied voltage. In addition, optimal raw gas flow rate(2.4 m/sec) is more important factor than the excessive increase of dust collecting area.

건축물의 중수도 설치기준에 대한 제도적 개선방안 (An Institutional Improving Standards for Water Reclamation/Reuse(WRR) System Establishment to Buildings)

  • 공영효
    • KIEAE Journal
    • /
    • 제6권3호
    • /
    • pp.43-48
    • /
    • 2006
  • This paper aims to suggest ways of institutionally improving standards that must be applied when installing Water Reclamation/Reuse (WRR) system based on efficiency analysis. Currently, the standard for WRR system establishment requires that the system should treat more than 10% of used water in the building of over $60,000m^2$ in total area of all floors, but our research has found that it would be more effective to change the standard to $150-m^3-per-day$ reclaimed water or the total area of all floors of $30,000m^2$ ($50,000m^2$ in the case of an office building). In other words, what this paper suggests is not a one-size-fits-all standard based on the total area of all floors, but a reasonable and flexible standard that takes into account efficiency and a unit water usage according to a building's purpose. Furthermore, this paper recommends a new WRR standard that can be applied to large-scale land development for housinglots, like the New Town. The recommendation is based on the economic analysis that the WRR system will ensure efficiency only if the amount of reclaimed water is over 4,000 tons per day, which corresponds to 4 millions square meters of housinglots. Regarding the size of the established facility, this paper suggests changing the standard, which is now set at over 10% of water usage, to what is relative to the total amount of use of reclaimed water in order to ensure efficiency and promote use of reclaimed water. In addition, this paper proposes that governmental support should be offered not only to facility owners, who are recipients at present, but also to facility builders. By doing so, those who donate a facility to the government, central or local, after building it, can be provided with substantial aid. Therefore, the application of the institutional improvement suggested in this paper is expected to create environment-friendly living conditions and boost the quality of life by encouraging people to secure water resources efficiently in buildings, and in a wider range, in cities.

Rapid Prototyping and Reverse Engineering Application for Orthopedic Surgery Planning

  • Ahn Dong-Gyu;Lee Jun-Young;Yang Dong-Yol
    • Journal of Mechanical Science and Technology
    • /
    • 제20권1호
    • /
    • pp.19-28
    • /
    • 2006
  • This paper describes rapid prototyping (RP) and reverse engineering (RE) application for orthopedic surgery planning to improve the efficiency and accuracy of the orthopedic surgery. Using the symmetrical characteristics of the human body, CAD data of undamaged bone of the injured area are generated from a mirror transformation of undamaged bone data for the uninjured area. The physical model before the injury is manufactured from Poly jet RP process. The surgical plan, including the selection of the proper implant, pre-forming of the implant and decision of fixation positions, etc., is determined by a physical simulation using the physical model. In order to examine the applicability and efficiency of the surgical planning technology, two case studies, such as a distal tibia comminuted fracture and an iliac wing fracture of pelvis, are carried out. From the results of the examination, it has been shown that the RP and RE can be applied to orthopedic surgical planning and can be an efficient surgical tool.

마그네슘 금속연료전지의 출력특성에 관한 연구 (A Study of Power Output Characteristics for the Magnesium Metal Fuel Cell)

  • 김용혁
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.212-217
    • /
    • 2014
  • The electric power output characteristics of magnesium fuel cell were investigated with regard to internal resistance. A equivalent circuit with the series-connected three internal resistance was introduced to analyze of the response to change of power. The power output analysis was employed in order to investigate the effect of internal resistances for the electrolyte concentration, air electrode area, Mg electrode area and distance between the electrodes. It was confirmed that internal resistance is generated by the electrolyte, air electrode and metal electrode, then those Internal resistances had a significant effect on the power output decrease. The power output was a maximum when the load resistance maches the internal resistance of the magnesium fuel cell. The fuel efficiency was only 50% at maximum power output. Higher fuel efficiency was achieved when the load resistance is greater than the internal resistance.

물류센터의 에너지 효율 개선 방안에 관한 연구 (A Study on the Improvement of Energy Efficiency in Warehouses)

  • 선종근;류호상
    • 조명전기설비학회논문지
    • /
    • 제26권6호
    • /
    • pp.66-72
    • /
    • 2012
  • The main sources of energy consumption in warehouses are MHE(Material Handling Equipment), HVAC(Heating, Ventilating and Air Conditioning) and Lighting. Warehouses in advanced countries raise energy efficiencies with energy consumption diagnosis, technology development and systematic management and improvements for MHE, HVAC and Illuminating, etc. They have managed illuminating system, air conditioning, motor driven system, air circulation method, dock facility, layout, AS/RS, conveyor system and battery management, etc. Ansong Pyeongtaek area investigation resulted that 43.9[%] of enterprises are managing partly energy consumption source. But the data resulted with not substantial management of energy consumption but passive management for only electric bill curtailment. Therefore through survey research & visiting interviews of some companies in Ansong Pyeongtaek area, we understood the status of energy consumption source management and proposed energy efficiency methods on the basis of that results.

온칩된 커패시터 채배기법 적용 보상회로를 갖는 DC to DC 벅 변환기 설계 (Design of a Step-Down DC-DC converter with On-chip Capacitor multiplyed Compensation circuit)

  • 박승찬;임동균;윤광섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.537-538
    • /
    • 2008
  • A step-down DC-DC converter with On-chip Compensation for battery-operated portable electronic devices which are designed in 0.18um CMOS standard process. In an effort to improve low load efficiency, this paper proposes the PFM (Pulse Frequency modulation) voltage mode 1MHz switching frequency step-down DC-DC converter with on-chip compensation. Capacitor multiplier method can minimize error amplifier compensation block size by 20%. It allows the compensation block of DC-DC converter be easily integrated on a chip and occupy less layout area. But capacitor multiplier operation reduces DC-DC converter efficiency. As a result, this converter shows maximum efficiency over 87% for the output voltage of 1.8V (input voltage : 3.3V), maximum load current 500mA, and 0.14% output ripple voltage. The total core chip area is $mm^2$.

  • PDF