Rapid Prototyping and Reverse Engineering Application for Orthopedic Surgery Planning

  • Ahn Dong-Gyu (Department of Mechanical Engineering, Chosun University) ;
  • Lee Jun-Young (Department of Orthopedics, Chosun University) ;
  • Yang Dong-Yol (Department of Mechanical Engineering, KAIST)
  • Published : 2006.01.01

Abstract

This paper describes rapid prototyping (RP) and reverse engineering (RE) application for orthopedic surgery planning to improve the efficiency and accuracy of the orthopedic surgery. Using the symmetrical characteristics of the human body, CAD data of undamaged bone of the injured area are generated from a mirror transformation of undamaged bone data for the uninjured area. The physical model before the injury is manufactured from Poly jet RP process. The surgical plan, including the selection of the proper implant, pre-forming of the implant and decision of fixation positions, etc., is determined by a physical simulation using the physical model. In order to examine the applicability and efficiency of the surgical planning technology, two case studies, such as a distal tibia comminuted fracture and an iliac wing fracture of pelvis, are carried out. From the results of the examination, it has been shown that the RP and RE can be applied to orthopedic surgical planning and can be an efficient surgical tool.

Keywords

References

  1. Brown, G. A., Brenton, M. and Firoozbaksh, K., 2002, 'Application of Computer-Generated Stereolithography and Interpositioning Template in Acetabular Fracture : A Report of Eight Case,' Journal of Orthopaedic Trauma, Vol. 16, No.5, pp. 347-352 https://doi.org/10.1097/00005131-200205000-00010
  2. Brown, G. A., Firoozabkhsh, K., Decoster, T. A., Reyna, J. R. and Mcneim, M., 2003, 'Rapid Prototyping: The Future of Trauma Surgery',' The Journal of Bone and Joint Surgery, Vol. 85A, Supplement 4, pp.49-55
  3. Choi, H. R., Jun., Y., Chang, M., Rho, H. -M. and Park, S., 2001, 'A Reverse Engineering System for Reproducing a 3D Human Bust,' Proceedings of KSPE Spring Annual Meeting 2001, pp.15-19
  4. Goto, M., Katsuki, T., Noguchi, H. and Hino, N., 1997, 'Surgical Simulation for Reconstruction of Mandibular Bone Defects using Photocurable Plastic Skull Models: Report of Three Cases,' Journal of Oral & Maxillofacial Surgery, Vol. 55, pp.772-780 https://doi.org/10.1016/S0278-2391(97)90597-8
  5. Kai, C. C., Meng, C. S., Ching, L. S., Hoe, E. K. and Fah, L. K., 1998, 'Rapid Prototyping Assisted Surgery Planning,' The International Journal of Advanced Manufacturing Technology, Vol. 14, pp. 624-630 https://doi.org/10.1007/BF01192281
  6. Kim, S. K. and Son, Y. R., 2004, 'Investigation on Airflows in Abnormal Nasal Cavity with Adenoid Vegetation by Particle Image Velocimetry,' KSME International Journal, Vol. 18, No. 10, pp. 1799-1808
  7. Kruth, J. P., Leu, M. C. and Nakagawa, T., 1998, 'Progress in Additive Manufacturing and Rapid Prototyping,' Annal of the CIRP, Vol. 47, No.2, pp. 525-540 https://doi.org/10.1016/S0007-8506(07)63240-5
  8. Kulkarni, P., Marson, D. and Dutta, D., 2000, 'A Review of Process Planning Techniques in Layered Manufacturing,' Rapid Prototyping Journal, Vol. 6, No. 1, pp. 18-35 https://doi.org/10.1108/13552540010309859
  9. Lee, H. K., Kim, H. C. and Yang, G. E., 2001, 'A Study on Digital Process of Injection Mold in Reverse Engineering,' Journal of the Korean Society of Precision Engineering, Vol. 19, No.6, pp. 160-165
  10. McGurk, M., Potamianos, P., Aimis, A. A., Gooder, N. M., 1997, 'Rapid Prototyping Techniques for Anatomical Modeling in Medicine,' Annals of the Royal College of Surgeons in England, Vol. 79, pp. 169-174
  11. Park, K. B., Kim, K. B., Son, K., Suh, J. T. and Moon, B. Y., 2004, 'Construction and Measurement of Three-Dimensional Knee Joint Model of Koreans,' Transaction of the Korean Society of Mechanical Engineering, Vol. 28, No. 11, pp. 1664-1671 https://doi.org/10.3795/KSME-A.2004.28.11.1664
  12. Petzold, R., Zeilhofer, H. -F. and Kalender, W. A., 1997, 'Rapid Prototyping Technology in Medicine-Basics and Applications,' Computerized Medical Imaging and Graphics, Vol. 23, No.5, pp.277-284 https://doi.org/10.1016/S0895-6111(99)00025-7
  13. Potamianos, P., Aims, A. A., Forester, A. J., McGurk, M. and Bircher, M., 1998, 'Rapid Prototyping for orthopedic surgery,' Proceedings of the Institute Mechanical Engineering Part H: Journal of Engineering in Medicine, Vol. 212, pp.383-393
  14. Sanghera, B., Naique, S., Papaharilaou, Y. and Amis, A., 2001, 'Preliminary Study of Rapid Prototypes Medical Models,' Rapid Prototyping Journal, Vol. 7, No.5, pp.275-284 https://doi.org/10.1108/13552540110410486
  15. Stocker, N. G., Mankovitch, N. J. and Valentino, D., 1992, 'Stereolithographic Models for Surgical Planning: Preliminary Report,' Journal of Oral & Maxillofacial Surgery, Vol. 50, pp. 446-471
  16. Sun, W. and Lal, P., 2002, 'Recent Development on Computer Aided Tissues Engineering - a Review,' Computer Methods and Programs in Biomedicine, Vol. 67, pp. 85-103 https://doi.org/10.1016/S0169-2607(01)00116-X
  17. Webb, P. A., 2000, 'A Review of Rapid Prototyping (RP) Techniques in the Medical and Biomedical Sector,' Journal of Medical Engineering & Technology, Vol. 24, No.4, pp. 149-153 https://doi.org/10.1080/03091900050163427
  18. Winder, J., Cooke, R. S., Gray, J., Fennin, T. and Fegan, T., 1999, 'Medical Rapid Prototyping and 3D CT in the Manufacture of Custom Made Cranial Titanium Plates,' Journal of Medical Engineering & Technology, Vol. 23, No. 1, pp.26-28 https://doi.org/10.1080/030919099294401
  19. Wohler, T. T., 2004, Wholer's Report 2004, Rapid Prototyping & Tooling State of the Industry, Wholer's Associates Inc.
  20. Yang, D. Y., Ahn, D. G., Lee, C. H., Park, C. H. and Kim, T. J., 2002, 'Integration of CAD/CAM/CAE/RP for Development of Metal forming,' Journal of Materials Processing Technology, Vol. 125, pp. 26-34 https://doi.org/10.1016/S0924-0136(02)00414-4
  21. http://www.materialise.com
  22. http://www.solutionix.co.kr
  23. http://www.sysopt.co.kr
  24. http://www.2objet.com