• 제목/요약/키워드: Arcing contacts

검색결과 20건 처리시간 0.025초

해수로 오염된 처점의 개간이-크의 발생과 소멸 (Arcing and Quenching of the Contacts Contaminated with Sea Water)

  • 조광현;박상길;박정후
    • 대한전기학회논문지
    • /
    • 제34권4호
    • /
    • pp.135-143
    • /
    • 1985
  • The failure and erosion of relay contacts mainly depend on the presence of particles deposited on the contact surface in various contaminated atmospheres. In this paper, the effects of sea water and circuit parameters on the arcing and quenching of magnet relay contacts are studied. The sea water pollutants of relay contact surface have led to increase the arcing numbers on making contact, and the mean arc durations on breaking contacts. Moreover, the maximum surge voltage and mean arc duration between relay contacts are also varied significantly by the circuit parameters. The effects of the spark quenching circuits using condenser of diode on the arcing of contacts are also discussed.

  • PDF

170kV 50kA 콘덴서 불용형 SF6 가스절연개폐기의 극간 전계해석 (Electric Field Analysis of 170kV 50kA Class SF6 GCB Without Capacitor)

  • 송태헌;배동진;최영찬;김익모;윤치영;강종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.351-353
    • /
    • 1999
  • In this paper, electric field analysis of 170kV class GCB is carried out. Considering the movement of arcing contacts during circuit interruption, electric field analysis between moving and fixed contacts is performed with changing the stroke length. From analysis results, electric field stresses are high at stationary arcing contact, moving arcing contact and varies at changing nozzle shapes. Specially, the stationary arcing contact shape has an significant effect on the capacitive small current interruption and the reduction of the electric field stress at this area is important. Varying the shape of stationary arcing contact, electric field analysis is carried out and the optimal shpae of the fixed arcing contact where the electric field stress is low is designed.

  • PDF

아크지속시간 측정을 통한 나선형 VI 전극의 전극배치에 따른 아크제어 성능비교 (Comparison of Arc Control Ability as a Function of Configuration of Spiral Type VI Contacts by Measuring Arcing Time)

  • 김병철;박홍태;오일성;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제22권2호
    • /
    • pp.184-190
    • /
    • 2009
  • One of the purposes of arc control is to change its state to the diffuse state before current zero as soon as possible. This can provide optimal conditions for full extinction of arc by minimizing the quantity of residual plasma between contacts near current zero. TRV(transient recovery voltage) occurs at current zero at the same time with current interruption. If there is substantial residual plasma near current zero it can cause 'post arc current' by the interaction of its conductance with TRV. In this paper, arc control ability as a function of configuration of spiral type VI contacts was compared on the criteria of the time taken for arc to reach to the diffuse state.

전기기기용 비닐절연전선에서의 직렬 아크에 의한 열화 특성 분석 (Analysis of Deterioration Characteristics of Polyvinyl Chloride Insulation Wires for Electrical Apparatus by Series Arcing)

  • 김향곤;길형준;김동욱;김동우;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.234-235
    • /
    • 2006
  • In this study, we experimented deterioration characteristics of PVC insulation wires for electrical apparatus by series arcing and analyzed the heat generation at the contacts of wires, glowing/growing process of copper oxide, waveforms of contact voltage, current, power dissipation, and so on. We found out that how glowing contacts and surface arcing can decompose PVC insulation and that subsequent series arc can lead to ignition. We expect that these results are useful for improving fire protection technology by providing a better understanding of how electrical fires can initiate.

  • PDF

초고압급 가스차단기용 노즐 및 아크접점의 내아크 특성시험 (Tests of the arc-resistant characteristics of nozzle and arcing contact for EHV class GCB)

  • 송기동;정진교;박경엽;권기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.89-93
    • /
    • 1997
  • Various types of nozzles and arcing contacts for EHV class GCB have been made to investigate the arc-resistant characteristics of them during short-circuit tests. The tested results are presented and analyzed to give useful information for GCB nozzle and contact manufacturers.

  • PDF

저압용 비닐절연전선에서의 직렬 아크 특성 분석 (Study on the Characteristics Analysis of Series Arcing at the PVC Insulation Wire for Low Voltage)

  • 김향곤;김동욱;김동우;이기연;최충석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.57-59
    • /
    • 2006
  • In this study, we experimented a deterioration characteristics by series arcing with 600V polyvinyl chloride insulation wire and analyzed the glowing/growing process of copper oxide, waveforms of contact voltage, current, power dissipation and carbonized patterns of insulation. We know that how glowing contacts and surface arcing can decompose PVC insulation and that it is possible for the subsequent series arc to ignite, and burn insulation. We expect that these results are useful for advancing the state-of-the-art in fire protection by Providing a better understanding of how electrical fires can initiate.

  • PDF

Three-phase Making Test Method for Common Type Circuit Breaker

  • Ryu, Jung-Hyeon;Choi, Ike-Sun;Kim, Kern-Joong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.778-783
    • /
    • 2012
  • The synthetic short-circuit making test to adequately stress the circuit breaker has been specified as the mandatory test duty in the IEC 62271-100. The purpose of this test is to give the maximum pre-arcing energy during making operation. And this requires the making operation with symmetrical short-circuit current that is established when the breakdown between contact gap occurs near the crest of the applied voltage. Also, if the interrupting chamber of circuit breakers is designed as the type of common enclosure or the operation is made by the gang operated mechanism that three-phase contacts are operated by one common mechanism, three-phase synthetic making test is basically required. Therefore, several testing laboratories have developed and proposed their own test circuits to properly evaluate the breaker performance. With these technical backgrounds, we have developed the new alternative three-phase making circuit.

가스 메탈 아크 용접에서 단락현상 모델링 및 스패터 감소를 위한 전류파형 선정에 관한 연구 (A Study on Modeling of Short-Circuliting Phenomena and Selection of Current Waveform for Reduction of Spatter in GMAW)

  • 황주호;문형순;나석주;한광수
    • Journal of Welding and Joining
    • /
    • 제14권1호
    • /
    • pp.57-67
    • /
    • 1996
  • With an expansion in automation of welding processes, emphasis has been shifted from other welding processes to the GMA welding. However, there is a problem with this process that the spatter occurs very frequently. In GMA welding, there are several types in the way of metal transfer from the electrode wire to the weld pool, which have a close relatonship with the spatter genetration. This study was concerned with the spatter occurring in the short-circuiting transfer. In welding with short-circuiting, the electromagnetic force formed by the welding current facilitatics the rupture of the metal bridge between the wire and workpiece and ensures the normal process of the welding process. However, the spatter can be genetrated from the droplet because of the upward magnetic force, when the droplet contacts with the weld pool. The passage of current through the bridge results in the accumulation of the thermal energy, which causes the bridge to explode in the final stage of short-circuiting, thus forming the spatter. Based on the above phenomena in conjunction with other experimental results published, the physical phenomenon related with the occurrence of spatter was modeled and the current waveform was investigated to reduce the spatter. Finally, the fuzzy rule based method was proposed to predict the time of short-circuiting and arcing in the metal transfer.

  • PDF

PTFE 노즐로부터 발생하는 용삭가스를 고려한 스위칭 아크 해석 (Numerical Analysis of Switching Arcs with the Ablation of PTFE Nozzles)

  • 이원호;김홍규;이종철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1536-1537
    • /
    • 2011
  • The high-voltage circuit breaker plays an important role in the electrical system because there has been a need for suitable switching devices capable of initiating and interrupting the flow of the electric fault current. It continues as the contacts recede from each other and as the newly created gap is bridged by a plasma. The arc plasma happens inside the insulation nozzle of SF6 self-blast interrupter which is newly developed as the next-generation switching principle. The ablation of PTFE nozzle is caused by this high temperature medium, the PTFE vapor from the nozzle surfaces flows toward the outlets and the pressure chamber. The vapor makes the pressure of the chamber increased by heat and mass transfer from the arcing zone. Because the rate of ablation depends on the magnitude of applied current, it decreases when the current goes to zero. The compressed gas inside the chamber flows reversely toward the arc plasma during this moment. According to this principle, the arc can be cooled down and the fault current can be interrupted successfully. In this study, we calculate arc plasmas and thermal-flow characteristics caused by fault current interruption inside a SF6 self-blast interrupter, and to investigate the effect of PTFE ablation on the whole arcing history.

  • PDF