• Title/Summary/Keyword: Architectural Materials

Search Result 1,313, Processing Time 0.024 seconds

A Study on the Facade Design of Domestic Company Buildings that have Expressed the Characteristics of Corporate Images (기업 이미지 특성을 표현한 국내 사옥 파사드 디자인에 관한 연구)

  • Kim, Hyun-Shin;Choi, Sang-Hun
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.187-194
    • /
    • 2014
  • Corporate images are created inside the corporate and then peppered throughout the public such as consumers, communities, countries, etc. who are outside the corporate. Therefore, corporations express their corporate images through such visible images as CI, products, brands, advertisements, company buildings, etc. in order to form a favorable corporate image for the public. Therefore, many corporations have begun to express various visual factors in order to form their images. So, the purpose of this study is to determined the connectivities of corporate images and facade design of company buildings, and to elicit the findings of whether corporate images are applied to the facade design of company buildings, and of what expressive factors are applied to the design, if so. The conclusions are as follows: First, an examination of the degree that the characteristics of corporate images and design components of the facade design of company buildings have been expressed showed that corporations preferred the design of company buildings on which a lot of components have been expressed. Second, it also showed that they preferred determinants of the facade design of company buildings in the order of architectural factors > visual factors > decorative factors. Third, it indicated that the corporations on which the design components of the facade design of company buildings have been reflected most were in the order of C > B, D > A, E > G > F, J > H, I. Fourth, it further showed that most of the corporations have used curtain walls as materials of the facade design.

A Study on the Construction of Main Sanctuary of Dogapsa Temple -Focused on Establishing Bay of columns and Setback Technique in Upper Stories of Traditional Architecture with Multi Roof- (도갑사대웅보전(道岬寺大雄寶殿)의 조영(造營)에 관한 연구(硏究) -전통중층목조건축의 주칸설정과 상층체감기법을 중심으로-)

  • Shin, Woong-Ju;Lee, Bong-Soo;Park, Gang-Chul
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.1
    • /
    • pp.45-54
    • /
    • 2011
  • The results of examining the architectural features and changes of the main building of Dogapsa temple which is multi roofs wooden structure are as follows. The passage comparing 'Dogapsa' of <>, account of Lee Ha Gon's trip as the literature showing the appearance of Dogapsa temple in the early 18th century to Borimsa through verse of 'Dutacho' was noticeable. Dogapsa temple at Yeongam was distant over 100 ri from Borimsa temple at Jangheung and it was considered that there were many temples at Mt. Wolchul, Yeongam and there were also many temples to be comparable with it. But, Dogapsa temple was compared to Borimsa temple because verses 'many-storied building is high and immense' of 'Dogapsa' at <> and 'Dogapsa is lower than Borimsa at Jangheung' at 'Dutacho' of <> were interpreted as the existence of multi roofs Buddhist temple which had something in common with Dogapsa and Borimsa and was comparable to them. According to existing materials, it was assumed that the main building of Dogapsa was burnt through the Japanese invasion of Korea in the 52nd year of the sexagenary cycle (Eulmyooebyeon, 1555) and Jungyujaeran (1597), but record of major history of the main buildings of Dogapsa and Borimsa indicated that multi roofs wooden structure of the two temples were built at the same period. Since multi roofs wooden structure of main building of Borimsa was rebuilt in 1692, these buildings existed from the early 18th century to middle 18th century.

Analysis of BIM Impact on Preventing Rework in Construction Phase (시공단계 BIM 적용에 의한 재시공 방지 효과분석)

  • Lee, Myung-Do;Cha, Min-Su;Lee, Ung-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.2
    • /
    • pp.169-176
    • /
    • 2018
  • The purpose of this study is to analyze the effects of applying BIM to the construction phase on preventing rework. Previous studies have presented the contribution of BIM in various ways, but a more practical and reliable analysis methodology are required. In this study, a BIM effect analysis methodology was proposed after collecting requirements on BIM effect analysis from field professionals. In the case study, the rework prevention effect was analyzed based on the proposed methodology. As a result, it was found that BIM application produced the rework prevention effect of approximately KRW 370,519,593. In addition, a consultation with field professionals on the suitability of the proposed methodology and effect analysis results were revealed that the results were sufficiently reliable. The results of this study can be used as efficient basic materials for research on BIM performance measurement in the future.

Experimental and Analytical Study on the Steel Beam bonded with CFRP Strip (레진으로 접착 보강한 강재보의 거동)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.1
    • /
    • pp.81-88
    • /
    • 2017
  • In this paper, the behaviour of composite steel-CFRP members is studied experimentally and using FE-analysis. The use of advance composite materials in construction for repair and rehabilitation has become a frequent used method in the last decade. FRP composites have many advantages over the traditional technique of steel bonding for a number of reasons: 1. Composites add little or no additional weight to a building, eliminating the need for costly foundation strengthening. 2. FRP composites are very thin (1.2mm to 1.4mm). So there is no loss of floor space and negligible effect over the architectural aspect. 3. FRP composites do not corrode, this makes it long lasting. However, the method is yet to become a mainstream application due to a number of economical and design related issues. Brittle debonding failure, aging effect on bonding, broad based awareness and proper design guidelines are the main concern for future research works. This paper is focused on the ultimate load carrying capacity of the CFRP-strengthened beams and their effect on the deflection and failures modes by varying the amount of CFRP content.

Quality Management Platform of Ocher Concrete Using Nondestructive Tests Based on the Stress Waves (응력파기반 비파괴검사법을 이용한 황토콘크리트 품질관리 플랫폼)

  • Hong, Seong-Uk;Kim, Seung-Hun;Kim, Seong-Yeob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.120-127
    • /
    • 2016
  • Several problems including respiratory and skin disorders due to the problems for sick house syndrome have occurred, there appears echo friendly materials to solve the problems. The research is lacking in quality management techniques ocher concrete using nondestructive tests. In this research, the experimental works were conducted to study the initial quality control for the compressive strength of Ocher concrete(21 MPa). The purpose of this study is the implementation platform for quality management of ocher concrete using nondestructive tests. It uses the relationship between the compressive strength and ultrasonic pulse velocity of the ocher concrete to estimate the compressive strength of the ocher concrete. And using the impact echo method to estimate the thickness of the ocher concrete. The platform is based on a Java script, so that the user can obtain the data through the platform.

Ultrasound Breast Elastographic Evaluation of Mass-Forming Ductal Carcinoma-in-situ with Histological Correlation - New Findings for a Toothpaste Sign

  • Leong, Lester Chee Hao;Sim, Llewellyn Shao-Jen;Jara-Lazaro, Ana Richelia;Tan, Puay Hoon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2673-2678
    • /
    • 2016
  • Background: It is unclear as to whether the size ratio elastographic technique is useful for assessing ultrasound-detected ductal carcinoma-in-situ (DCIS) masses since they commonly lack a significant desmoplastic reaction. The objectives of this study were to determine the accuracy of this elastographic technique in DCIS and examine if there was any histopathological correlation with the grey-scale strain patterns. Materials and Methods: Female patients referred to the radiology department for image-guided breast biopsy were prospectively evaluated by ultrasound elastography prior to biopsy. Histological diagnosis was the gold standard. An elastographic size ratio of more than 1.1 was considered malignant. Elastographic strain patterns were assessed for correlation with the DCIS histological architectural patterns and nuclear grade. Results: There were 30 DCIS cases. Elastographic sensitivity for detection of malignancy was 86.7% (26/30). 10/30 (33.3%) DCIS masses demonstrated predominantly white elastographic strain patterns while 20/30 (66.7%) were predominantly black. There were 3 (10.0%) DCIS masses that showed had a co-existent bull's-eye sign and 7 (23.3%) other masses had a co-existent toothpaste sign, a strain pattern that has never been reported in the literature. Four out of 4/5 comedo DCIS showed a predominantly white strain pattern (p=0.031) while 6/7 cases with the toothpaste sign were papillary DCIS (p=0.031). There was no relationship between the strain pattern and the DCIS nuclear grade. Conclusions: The size ratio elastographic technique was found to be very sensitive for ultrasound-detected DCIS masses. While the elastographic grey-scale strain pattern should not be used for diagnostic purposes, it correlated well with the DCIS architecture.

Influence of different boost techniques on radiation dose to the left anterior descending coronary artery

  • Park, Kawngwoo;Lee, Yongha;Cha, Jihye;You, Sei Hwan;Kim, Sunghyun;Lee, Jong Young
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.242-249
    • /
    • 2015
  • Purpose: The purpose of this study is to compare the dosimetry of electron beam (EB) plans and three-dimensional helical tomotherapy (3DHT) plans for the patients with left-sided breast cancer, who underwent breast conserving surgery. Materials and Methods: We selected total of 15 patients based on the location of tumor, as following subsite: subareolar, upper outer, upper inner, lower lateral, and lower medial quadrants. The clinical target volume (CTV) was defined as the area of architectural distortion surrounded by surgical clip plus 1 cm margin. The conformity index (CI), homogeneity index (HI), quality of coverage (QC) and dose-volume parameters for the CTV, and organ at risk (OAR) were calculated. The following treatment techniques were assessed: single conformal EB plans; 3DHT plans with directional block of left anterior descending artery (LAD); and 3DHT plans with complete block of LAD. Results: 3DHT plans, regardless of type of LAD block, showed significantly better CI, HI, and QC for the CTVs, compared with the EB plans. However, 3DHT plans showed increase in the $V_{1Gy}$ at skin, left lung, and left breast. In terms of LAD, 3DHT plans with complete block of LAD showed extremely low dose, while dose increase in other OARs were observed, when compared with other plans. EB plans showed the worst conformity at upper outer quadrants of tumor bed site. Conclusion: 3DHT plans offer more favorable dose distributions to LAD, as well as improved target coverage in comparison with EB plans.

Seismic vulnerability assessment of composite reinforced concrete-masonry building

  • Remki, Mustapha;kehila, Fouad;Bechtoula, Hakim;Bourzam, Abdelkrim
    • Earthquakes and Structures
    • /
    • v.11 no.2
    • /
    • pp.371-386
    • /
    • 2016
  • During the last decades, many destructive earthquakes occurred in Algeria, particularly in the northern part of the country (Chlef (1980), Constantine (1985), Tipaza (1989), Mascara (1994), Ain-Benian (1996), Ain Temouchent (1999), Beni Ourtilane (2000), and recently $Boumerd{\acute{e}}s$ (2003), causing enormous losses in human lives, buildings and equipments. In order to reduce this risk and avoid serious damages to the strategic existing buildings, the authorities of the country, aware of this risk and in order to have the necessary elements that let them to know and estimate the potential losses in advance, with an acceptable error, and to take the necessary countermeasures, decided to invest into seismic upgrade, strengthening and retrofitting of those buildings. To do so, seismic vulnerability study of this category of buildings has been considered. Structural analysis is performed based on the site investigation (inspection of the building, collecting data, materials characteristics, general conditions of the building, etc.), and existing drawings (architectural plans, structural design, etc.). The aim of these seismic vulnerability studies is to develop guidelines and a methodology for rehabilitation of existing buildings. This paper presents the methodology, based on non linear and seismic analysis of existing buildings, followed in this study and summarizes the vulnerability assessment and strengthening of one of the strategic buildings according to the new Algerian code RPA 99/version 2003. As a direct application of this methodology, both, static equivalent method and non linear dynamic analysis, of composite concrete masonry existing building in the city of "CONSTANTINE", located in the east side of ALGERIA, are presented in this paper.

Structural Performance Evaluation of Reinforced Concrete Beams with Externally Bonded FRP Sheets (RC 구조물에 적용된 부착식 휨보강공법의 보강성능 평가)

  • Hong, Geon-Ho;Shin, Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.78-86
    • /
    • 2003
  • Reinforced concrete beams are often retrofitted with various FRP composite sheets. This paper is focused on the comparison of structural performance of various FRP sheets and proposal of the retrofitting design formula. Effects of the FRP kinds(AFRP, GFRP, CFRP) and the reinforcing steel ratio on behavior of the retrofitting beams are tested and analyzed with particular emphasis on the maximum load capacity, stiffness, and ductility. The experimental work included 4 point flexural testing of 3.2m span reinforced concrete beams with bonded external reinforcements. The results show that the difference of FRP kinds is not large and the flexural load capacity is mainly affected by stiffness of the retrofitting materials. This paper also proposes the design formula on the retrofitting reinforced concrete flexural members and checks with this experimantal work and previous research results.

Effect of Adding Scoria as Cement Replacement on Durability-Related Properties

  • al-Swaidani, Aref Mohamad;Aliyan, Samira Dib
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.2
    • /
    • pp.241-254
    • /
    • 2015
  • A lot of reinforced concrete (RC) structures in Syria went out of service after a few years of construction. This was mainly due to reinforcement corrosion or chemical attack on concrete. The use of blended cements is growing rapidly in the construction industry due to economical, ecological and technical benefits. Syria is relatively rich in scoria. In the study, mortar/concrete specimens were produced with seven types of cement: one plain Portland cement (control) and six blended cements with replacement levels ranging from 10 to 35 %. Rapid chloride penetration test was carried in accordance with ASTM C 1202 after two curing times of 28 and 90 days. The effect on the resistance of concrete against damage caused by corrosion of the embedded steel has been investigated using an accelerated corrosion test by impressing a constant anodic potential. The variation of current with time and time to failure of RC specimens were determined at 28 and 90 days curing. In addition, effects of aggressive acidic environments on mortars were investigated through 100 days of exposure to 5 % $H_2SO_4$, 10 % HCl, 5 % $HNO_3$ and 10 % $CH_3COOH$ solutions. Evaluation of sulfate resistance of mortars was also performed by immersing in 5 % $Na_2SO_4$ solution for 52 weeks. Test results reveal that the resistance to chloride penetration of concrete improves substantially with the increase of replacement level, and the concretes containing scoria based-blended cements, especially CEM II/B-P, exhibited corrosion initiation periods several times longer than the control mix. Further, an increase in scoria addition improves the acid resistance of mortar, especially in the early days of exposure, whereas after a long period of continuous exposure all specimens show the same behavior against the acid attack. According to results of sulfate resistance, CEM II/B-P can be used instead of SRPC in sulfate-bearing environments.