• Title/Summary/Keyword: Arc instability

Search Result 34, Processing Time 0.03 seconds

Characteristics of Spatter Generation in the Short Circuit Transfer Region of $CO_2$ Arc Welding ($CO_2$ 용접의 단락이행영역에 있어서 스패터 발생특성)

  • 안영호;이종봉;최원규
    • Journal of Welding and Joining
    • /
    • v.19 no.6
    • /
    • pp.630-635
    • /
    • 2001
  • The characteristics of spatter generation in the short circuit transfer region of $CO_2$ welding was investigated. Spatteriing phenomena could be classified into three types : Type I generated due to the abrupt increase of arc voltage in arcing duration. Type II by the gas ejection from molten metal and Type III generated by the arc instability at the moment of arc re-ignition just after short circuiting. Main observed types were dependent on the chemical composition of welding wires. The case of YCW12 wires was mainly composed of spatters generated by Type l and Type II, while most, spatters in YCW11 wires were generated by Type II and Type III.

  • PDF

Connection between a Small-Scale Emerging Island and Double Arc Loops Producing a M6.5 Flare in Active Region 12371

  • Kang, Jihye;Inoue, Satoshi;Moon, Yong-Jae;Magara, Tetsuya;Kusano, Kanya
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.81.3-81.3
    • /
    • 2017
  • In this paper, we report a small-scale emerging island and double arc loops, which are associated with a M6.5 flare, in Active Region 12371. We investigate the spatial and temporal changes of both photospheric magnetic fields using SDO/HMI data and coronal magnetic structures obtained from nonliner force-free field (NLFFF) extrapolation. From the vector magnetograms, we find a small-scale emerging island near the main polarityy inversion line about three hours before the flare. The island has a strong shear angle, which is determined by difference between transverse component of observed field and potential field, of around 90 degrees. Furthermore, the NLFFF well reproduces a sigmoidal structure seen in SDO/AIA 94, which is consistent with the double arc loops configuration suggested by Ishiguro and Kusano (2017) who introduced a magnetic configuration showing the double arc instability. The observed emerging island is located among the double arc loops, which is also supproted by their model. Finally, there was an eruption (M6.5 flare) associated with the loops. We discuss a possible role of the double arc instability for the eruption.

  • PDF

Control Strategy of Smoothing Arc for DC Arc Furnace

  • Jung, Kyungsub;Suh, Yongsug;Lee, Yongjoong;Kim, Taewon;Park, Taejun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.354-355
    • /
    • 2013
  • Fundamental features of the arc stability in DC arc furnace of 720V/100kA/72MW have been investigated. Cassie-Mayr arc model has been employed and applied for the target dc arc furnace. In order to characterize the parameters of Cassie-Mayr arc model and the behavior of unstable arc dynamics, the advanced arc simulations of magneto-hydrodynamics (MHD) has been performed. The MHD based arc simulation has been validated in the subcomponent level, for the free burning arc set up in the laboratory. From the results of MHD simulation, dc arc dynamic resistance is proposed to be an effective arc stability function reflecting the instability of dynamic arc behavior. The experimental result confirms the usefulness of proposed dynamic arc resistance as arc stability function. The proposed arc stability function can be regarded as an effective criterion for the overall power conversion system to maintain highly stable arcing operation leading to better productivity and reliability.

  • PDF

Control Algorithm of Thyristor Rectifier to Improve Arc Stability in DC Arc Furnace

  • Jung, Kyungsub;Suh, Yongsug;Kim, Taewon;Park, Taejun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.371-372
    • /
    • 2012
  • In this paper fundamental features of the arc stability in DC arc furnace of 720V/100kA/72MW have been investigated. Cassie-Mayr arc model has been employed for the target dc arc furnace. In order to characterize the parameters of Cassie-Mayr arc model and the behavior of unstable arc dynamics, the advanced arc simulations of magneto-hydrodynamics (MHD) has been performed. Based on the results of MHD simulation, dc arc dynamic resistance is proposed to be an effective arc stability function reflecting the instability of dynamic arc behavior. The experimental result confirms the usefulness of proposed dynamic arc resistance as arc stability function. The proposed arc stability function can be regarded as an effective criterion for the overall power conversion system to maintain highly stable arcing operation leading to better productivity and reliability.

  • PDF

A Dynamic Simulation at Voltage Instability using EMTP (EMTP를 이용한 전압 불안정 현상의 동적 시뮬레이션)

  • Heo, J.Y.;Kwon, O.S.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.131-133
    • /
    • 2003
  • Voltage instability has been studied for some decade now. But, there is not generally accepted definition of voltage instability because of the complex phenomenon and the variety of ways in which it can manifest itself. Both IEEE and CIGRE have the respective definitions. The areas of voltage instability research arc the analysis, simulation and countermeasure of voltage instability. In this paper, we perform a dynamic simulation of voltage instability and voltage collapse using EMTP MODELS. The exponential load model is designed with MODELS and this load model is connected with test power system. The result shows the process of voltage change in time domain when the voltage instability or voltage collapse occurs.

  • PDF

Stability of a magnetic structure producing an M6.5 flare in the active region 12371

  • Kang, Jihye;Inoue, Satoshi;Kusano, Kanya;Park, Sung-Hong;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.83.2-83.2
    • /
    • 2019
  • We study the stability of the magnetic structure in active region (AR) 12371 producing an M6.5 flare on June 22 2015. We first perform a nonlinear force-free fields (NLFFFs) extrapolation to derive three-dimensional (3D) magnetic fields based on time series of observed photospheric magnetic fields. The NLFFFs well describe an observed sigmoidal structure with the shape of a double arc magnetic configuration. Next, we examine three possible instabilities (kink, torus, and double arc) to investigate how the M6.5 flare is triggered in the double arc loops. Consequently, the double arc loops are stable against kink and torus instabilities, but possibly unstable against the double arc instability before the flare occurrence. Finally, we discuss a probable scenario for the M6.5 flare.

  • PDF

Analysis of Spray Mode Using Modified Pinch Instability Theory (핀치이론의 수정 모델을 이용한 스프레이 모드의 해석)

  • Park, Ah-Young;Hammad, Muhammad A.;Kim, Sun-Rak;Yoo, Choong-D.
    • Journal of Welding and Joining
    • /
    • v.27 no.5
    • /
    • pp.88-93
    • /
    • 2009
  • While the pinch instability theory (PIT) has been widely employed to analyze the spray transfer mode in the gas metal arc welding (GMAW), it cannot predict the detaching drop size accurately. The PIT is modified in this work to increase the accuracy of prediction and to simulate the molten tip geometry to be more physically acceptable. Since the molten tip becomes a cone shape in the spray mode, the effective wire diameter is formulated that the effective diameter is inversely proportional to current square. Modifications are also made to consider the finite length of the liquid column and current leakage through the arc. While the effective diameter influences drop transfer significantly, the current leakage has negligible effects. The effects of modifications on drop transfer are analyzed, and the predicted drop diameters show good agreements with the experimental data of the steel wire.

Analysis of Spray Mode Using Modified Pinch Instability Theory (핀치이론의 수정 모델을 이용한 스프레이 모드의 해석)

  • Park, Ah-Young;Hammad, Muhammad A.;Kim, Sun-Rak;Yoo, Choong-D.
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.44-44
    • /
    • 2009
  • While the pinch instability theory (PIT) has been widely employed to analyze the spray transfer mode in the gas metal arc welding (GMAW), it cannot predict the detaching drop size accurately. The PIT is modified in this work to increase the accuracy of prediction and to simulate the molten tip geometry to be more physically acceptable. Since the molten tip becomes a cone shape in the spray mode, the effective wire diameter is formulated that the effective diameter is inversely proportional to current square. Modifications are also made to consider the finite length of the liquid column and current leakage through the arc. While the effective diameter influences drop transfer significantly, the current leakage has negligible effects. The effects of modifications on drop transfer are analyzed, and the predicted drop diameters show good agreements with the experimental data of the steel wire.

  • PDF

A study on the characteristics of vertical welding positions using GA steel sheet in the $CO_2$ welding (GA 강판에 대한 $CO_2$ 수직용접자세의 특성에 관한 연구)

  • Kim, Jae-Seong;Jo, Yong-Jun;Lee, Gyeong-Cheol;Lee, Bo-Yeong
    • Proceedings of the KWS Conference
    • /
    • 2007.11a
    • /
    • pp.36-38
    • /
    • 2007
  • The instability of the arc in the $CO_2$ arc welding affects the quality of the weld in the automotive industry. This paper evaluates the effects of the arc stability in $CO_2$ arc welding with respect to vertical welding positions. In this experiment, galva-annealed steel sheets(CA) were used as specimens, and these materials were welded by adopting new Cold Metal Transfer (CMT) process. For each sample, fillet joint welding trials were carried out using the same conditions. Each part of welding joints was welded with vertical-up, vertical-down position at $45^{\circ},\;90^{\circ}\;and\;135^{\circ}$ degrees. A high speed camera and a welding signal monitoring system were used for monitoring fluid-flow phenomena in weld pools and frequency measurements, respectively. Through this study, the welding position were found to be key factors mainly to influence the arc stability in $CO_2$ welding moreover and that the arc stability in the vertical-up welding position was observed to be more stable than the vertical-down welding position below $90^{\circ}$.

  • PDF

비정질 실리콘 박막의 주울 가열 유도 결정화 공정 중 발생하는 Arc-Instability 기구 규명 및 방지책

  • Hong, Won-Ui;No, Jae-Sang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.375-375
    • /
    • 2012
  • 최근 차세대 평판 디스플레이의 응용에 많은 주목을 받고 있는 AMOLED의 경우 전류구동 방식이기 때문에 a-Si TFT 보다는 LTPS-TFT가 요구되며, 대면적 기판에서의 결정립 크기의 균일도가 매우 중요한 인자이다. 비정질 실리콘 박막 상부 혹은 하부에 도전층을 개재하고, 상기도전층에 전계를 인가하여 그것의 주울 가열에 의해 발생한 고열에 의해 비정질 실리콘 박막을 급속 고온 고상 결정화하는 방법에 관한 기술인 JIC (Joule-heating Induced Crystallization) 결정화 공정은 기판 전체를 한번에 결정화 하는 방법이다. JIC 결정화 공정에 의하여 제조된 JIC poly-Si은 결정립 크기의 균일성이 우수하며 상온에서 수 micro-second내에 결정화를 수행하는 것이 가능하고 공정적인 측면에서도 별도의 열처리 Chamber가 필요하지 않는 장점을 가지고 있다. 그러나 고온 고속 열처리 방법인 JIC 결정화 공정을 수행 하면 Arc에 의하여 시편이 파괴되는 현상이 발견되었다. 본 연구에서는 Arc현상의 원인을 파악하기 위해 전압 인가 조건 및 시편 구조 조건을 변수로 결정화실험을 진행하였다. ARC가 발생하는 Si층과 Electrode 계면을 식각 분리하여 Electrode와 Si층 사이의 계면이 형성되지 않는 조건에서 전계를 인가하는 실험을 통하여 JIC 결정화 공정 중 고온에 도달하게 되면, a-Si층이 변형되어 형성된 poly-Si층이 전도성을 띄게 되고 인가된 전압이 도전층과 Poly-Si 사이에 위치한 $SiO_2$의 절연파괴(Dielectric breakdown)전압보다 높을 경우 전압 인가 방향에 수직으로 $SiO_2$가 절연 파괴되며 면저항 형태의 전도층의 단락이 진행되며 전도층이 완전히 단락되는 순간 Arc가 발생한다는 것을 관찰 할 수 있었다. 본 실험의 연구 결과를 바탕으로 Arc 발생을 방지하는 다양한 구조의 Equi-Potential 방법이 개발되었다.

  • PDF