• 제목/요약/키워드: Arc detector

검색결과 63건 처리시간 0.029초

웨이브렛 변환과 신경망 학습을 이용한 고저항 지락사고 검출에 관한 연구 (A Study on High Impedance Fault Detection using Wavelet Transform and Neural -Network)

  • 홍대승;유창완;임화영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권3호
    • /
    • pp.105-111
    • /
    • 2001
  • The research presented in this paper focuses on a method for the detection of High Impedance Fault(HIF). The method will use the wavelet transform and neural network system. HIF on the multi-grounded three-phase four-wires primary distribution power system cannot be detected effectively by existing over current sensing devices. These paper describes the application of discrete wavelet transform to the various HIF data. These data were measured in actual 22-9kV distribution system. Wavelet transform analysis gives the frequency and time-scale information. The neural network system as a fault detector was trained to discriminate HIF from the normal status by a gradient descent method. The proposed method performed very well by proving the right state when it was applied staged fault data and normal load mimics HIF, such as arc-welder.

  • PDF

BIPV 시스템의 안전성 향상을 위한 보호시스템 구성 및 특성 분석 (Characteristic Analysis and Configuration of the Protection System to Improve the Safety of the BIPV System)

  • 조석환;고재섭;김대경
    • 한국산업융합학회 논문집
    • /
    • 제27권3호
    • /
    • pp.591-599
    • /
    • 2024
  • This paper presents the configuration and characteristic analysis of the protection system to improve the safety of the building integrated photovoltaic(BIPV) system. BIPV is a solar power system installed in buildings. Since the BIPV system is installed in buildings, there is a high risk of electric shock and fire accidents. Therefore, in order to improve the safety of BIPV, a protective system is required to block or quickly detect risk factors. In this paper, as a protection system to improve the safety of the BIPV system, it is composed of a rapid shutdown (RSD) that can quickly separate the PV system to prevent fire and electric shock accidents and a system to detect Arc faults that cause PV system fires. RSD and Arc Fault Detector analyzed the operating characteristics according to each condition and confirmed that the safety of the BIPV system can be improved through this.

Sliding Arc Plasma를 이용한 석유공장에서의 BTX 처리효율에 관한 연구 (BTX Treatment of a Petrochemical Plant by Sliding Arc Plasma)

  • 권우택;권이승;이우식
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.65-70
    • /
    • 2015
  • 본 연구는 울산소재 석유공장의 건조시설에서 발생하는 가스를 스크러버(Scrubber)로 최종 처리하여 배출되는 저 농도의 유해가스와 산 처리 시설에서 발생되는 고 농도로 발생하는 유해가스를 대상으로 연구하였다. 공정별로 벤젠(Benzene), 톨루엔(Toluene), 자일렌(Xylene) 및 총휘발성유기화합물(TVOCs)을 대상으로 측정하였으며 농도 측정은 TVOCs 측정기와 GC-MSD를 이용하여 SAP 전 후단의 TVOCs와 BTX의 농도를 측정, 분석하여 제거효율을 평가하였고, SAP 반응기는 5 단계로 구성하여 실험을 수행하였다. 슬라이딩 아크 프라즈마(slidind arc plasma) 반응기의 단수별에 따른 TVOCs 농도 변화는 유입 TVOCs 농도의 변화에 따른 처리효율 결과 481 ppm 미만에서 94.83%, 481 ppm 이상일 경우에는 1단에서는 89.07% 2단에서는 약 91% 이상으로 처리되는 것을 확인할 수 있었다. 본 연구의 결과는 석유화학공정 및 제조시설에서 SAP 공정을 통한 VOCs 제거에 대한 연구 및 기술개발의 기초가 되어 VOCs의 보다 안정적인 처리와 다양한 기술개발에 효과가 있을 것으로 기대해 본다.

통신 전기설비 전기화재 예방을 위한 아크 스파크 검출기의 적용 방안 (Application of an Arc Spark Detector for Prevention of Electric Fires in Communication Facilities)

  • ;김희동;황충상
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2002년도 하계학술대회 및 세미나
    • /
    • pp.168-171
    • /
    • 2002
  • 통신 전기설비에서 발생하는 전기화재의 주된 원인은 아크 및 스파크에 있으며, 조기경보의 원리는 스파크 및 아크의 검출에 있다. 이러한 원리에 의한 상용화 제품인 ASD(아크스파크검출기)의 원리를 소개하고, 무인분기 국사에 대한 적용방안을 제시하였으며, 하나의 무인국사에서 단독 설치후 시험한 결과를 소개하였다.

  • PDF

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.

A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2

  • Jin, Hosang;Jesseph, Fredrick B.;Ahmad, Salahuddin
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.65-71
    • /
    • 2014
  • A Varian Portal Dosimetry system was compared to an isocentrically mounted MapCHECK 2 diode array for volumetric modulated arc therapy (VMAT) QA. A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire VMAT QA images for 13 plans using four photon energies (6, 8, 10 and 15 MV). The EPID-based QA images were compared to the Portal Dose Image Prediction calculated in the Varian Eclipse treatment planning system (TPS). An isocentrically mounted Sun Nuclear MapCHECK 2 diode array with 5 cm water-equivalent buildup was also used for the VMAT QAs and the measurements were compared to a composite dose plane from the Eclipse TPS. A ${\gamma}$ test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison at 1%/1 mm (dose difference/distance-to-agreement), 2%/2 mm, and 3%/3 mm criteria for both QA methods. The two-tailed paired Student's t-test was employed to analyze the statistical significance at 95% confidence level. The average ${\gamma}$ passing rates were greater than 95% at 3%/3 mm using both methods for all four energies. The differences in the average passing rates between the two methods were within 1.7% and 1.6% of each other when analyzed at 2%/2 mm and 3%/3 mm, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1 mm; the difference was lower for 8 MV and 10 MV. However, the differences were not statistically significant for all criteria and energies (p-values >0.05). The EPID-based QA showed large off-axis over-response and dependence of ${\gamma}$ passing rate on energy, while the MapCHECK 2 was susceptible to the MLC tongue-and-groove effect. The two fluence-based QA techniques can be an alternative tool of VMAT QA to each other, if the limitations of each QA method (mechanical sag, detector response, and detector alignment) are carefully considered.

Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer

  • Jeong, Yuri;Oh, Jeong Geun;Kang, Jeong Ku;Moon, Sun Rock;Lee, Kang Kyoo
    • Radiation Oncology Journal
    • /
    • 제38권1호
    • /
    • pp.60-67
    • /
    • 2020
  • Purpose: We performed three-dimensional (3D) dose reconstruction-based pretreatment verification to evaluate gamma analysis acceptance criteria in volumetric modulated arc therapy (VMAT) for prostate cancer. Materials and Methods: Pretreatment verification for 28 VMAT plans for prostate cancer was performed using the COMPASS system with a dolphin detector. The 3D reconstructed dose distribution of the treatment planning system calculation (TC) was compared with that of COMPASS independent calculation (CC) and COMPASS reconstruction from the dolphin detector measurement (CR). Gamma results (gamma failure rate and average gamma value [GFR and γAvg]) and dose-volume histogram (DVH) deviations, 98%, 2% and mean dose-volume difference (DD98%, DD2% and DDmean), were evaluated. Gamma analyses were performed with two acceptance criteria, 2%/2 mm and 3%/3 mm. Results: The GFR in 2%/2 mm criteria were less than 8%, and those in 3%/3 mm criteria were less than 1% for all structures in comparisons between TC, CC, and CR. In the comparison between TC and CR, GFR and γAvg in 2%/2 mm criteria were significantly higher than those in 3%/3 mm criteria. The DVH deviations were within 2%, except for DDmean (%) for rectum and bladder. Conclusions: The 3%/3 mm criteria were not strict enough to identify any discrepancies between planned and measured doses, and DVH deviations were less than 2% in most parameters. Therefore, gamma criteria of 2%/2 mm and DVH related parameters could be a useful tool for pretreatment verification for VMAT in prostate cancer.

Dosimetric Analysis on the Effect of Target Motion in the Delivery of Conventional IMRT, RapidArc and Tomotherapy

  • Song, Ju-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.164-170
    • /
    • 2017
  • One of the methods to consider the effect of respiratory motion of a tumor target in radiotherapy is to establish a treatment plan with the internal target volume (ITV) created based on an accurate analysis of the target motion displacement. When this method is applied to intensity modulated radiotherapy (IMRT), it is expected to yield a different treatment dose distribution under the motion condition according to the IMRT method. In this study, we prepared ITV-based IMRT plans with conventional IMRT using fixed gantry angle beams, RapidArc using volumetric modulated arc therapy, and tomotherapy using helical therapy. Then, the variation in dose distribution caused by the target motion was analyzed by the dose measurement in the actual motion condition. A delivery quality assurance plan was prepared for the established IMRT plan and the dose distribution in the actual motion condition was measured and analyzed using a two-dimensional diode detector placed on a moving phantom capable of simulating breathing movements. The dose measurement was performed considering only a uniform target shape and motion in the superior-inferior (SI) direction. In this condition, it was confirmed that the error of the dose distribution due to the target motion is minimum in tomotherapy. This is thought to be due to the characteristic of tomotherapy that treats the target sequentially by dividing it into several slices. When the target shape is uniform and the main target motion direction is SI, it is considered that tomotherapy for the ITV-based IMRT method has a characteristic which can reduce the dose difference compared with the plan dose under the target motion condition.

단기숙성치즈 및 EMC 치즈의 휘발성 풍미성분 신속분석방법으로서 Pyrolysis/GC-Mass Spectrometry의 이용 (Pyrolysis/GC-Mass Spectrometry Analysis for Rapid Identification of Volatile Flavour Compounds of Accelerated Ripened Cheddar Cheese and Enzyme-Modified Cheese)

  • 박승용;허강칠;신중엽
    • 한국축산식품학회지
    • /
    • 제21권3호
    • /
    • pp.256-264
    • /
    • 2001
  • Pyrolysis/GC-mass spectrometry(Hewlet-Packard 5890GC/mass selective detector, 5971 BMSD), interfaced to a CDS Pyroprobe 1500 was optimized for rapid analysis of flavour compounds in Cheddar cheese. Twenty flavour compounds, including aldehydes(4), ketones(4), fatty acids(10), alcohol(1), and hydrocarbon(1), were identified from Cheddar cheeses. In total, Twenty-three flavour compounds aldehydes(2), ketones(8), alcohols(3), fatty acids(7), lactone(1), benzene derivative(1) and amide(1) were identified from two samples of accelerated-ripened Cheddar cheese treated with the proteolytic enzymes of Lactobacillus casei LGY. In total, Twenty-one flavour compounds; aldehydes(2), ketones(5), alcohols(2), fatty acids(11), and lactone(1) were identified from enzyme-modified cheese(EMC) treated with the combination of the proteolytic enzymes of Lactobacillus casei LGY and commercial endopeptidase or lipase. However, All the flavour compounds identified by pyrolysis/GC/MS in samples of ARC and EMC were not determined whether they are recognized as typical Cheddar flavour or not. More studies were requested on the development of methods for a rapid and convienent analysis of dairy fermented products using pyrolysis/GC-mass spectrometry.

  • PDF

Optical In-Situ Plasma Process Monitoring Technique for Detection of Abnormal Plasma Discharge

  • Hong, Sang Jeen;Ahn, Jong Hwan;Park, Won Taek;May, Gary S.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권2호
    • /
    • pp.71-77
    • /
    • 2013
  • Advanced semiconductor manufacturing technology requires methods to maximize tool efficiency and improve product quality by reducing process variability. Real-time plasma process monitoring and diagnosis have become crucial for fault detection and classification (FDC) and advanced process control (APC). Additional sensors may increase the accuracy of detection of process anomalies, and optical monitoring methods are non-invasive. In this paper, we propose the use of a chromatic data acquisition system for real-time in-situ plasma process monitoring called the Plasma Eyes Chromatic System (PECS). The proposed system was initially tested in a six-inch research tool, and it was then further evaluated for its potential to detect process anomalies in an eight-inch production tool for etching blanket oxide films. Chromatic representation of the PECS output shows a clear correlation with small changes in process parameters, such as RF power, pressure, and gas flow. We also present how the PECS may be adapted as an in-situ plasma arc detector. The proposed system can provide useful indications of a faulty process in a timely and non-invasive manner for successful run-to-run (R2R) control and FDC.