• 제목/요약/키워드: Arc Fault

검색결과 229건 처리시간 0.024초

AFCI용 ASIC의 온도보상에 관한 연구 (A Study on the Temperature Compensation of ASIC for AFCI)

  • 양승국;이주
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.109-113
    • /
    • 2013
  • In order to avoid the electrical fire, AFCI(Arc Fault Cirruit Interrupter) has been obligated to be adopted in the United States of America since 2002. AFCI using line resistor of neutral trace needs to compensate the variation of the line resistance by temperature variation. In this paper, the ASIC including the temperature compensation circuit is implemented. The proposed implementation is verified by showing the effectiveness of an electric and a temperature characteristics for Arc signals by simulation results.

지락사고시 지중금속배관에 대한 아크이격거리에 관한 연구 (A Study on the Separation Distance to Protection of Buried Pipeline from Arc Strikes Caused by Power Line Ground Fault Current)

  • 하태현;배정효;이현구;김대경;김석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.154-155
    • /
    • 2002
  • The demand of the power and gas energy have been rapidly increasing with the industralization, therefore, the area where buried pipelines run parallel with the adjacent power lines and cross them increases in Seoul as well as other cities. These situation cause AC interference from the power lines. However, there aren't any standards to preserve the pipelines from AC interference in Korea. This study introduces the separation distance to protection of buried pipeline from arc strikes caused by power line ground fault current. And this study examines and compares the arc distance through case study.

  • PDF

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

반주기내 한류성능을 위한 진공차단기의 아크소호 (Arc Extinguishing of a Vacuum Interrupter for an HTS First Peak Current Limiter)

  • 김우석;박충렬;현옥배;김혜림;임성우;유승덕;양성은
    • Progress in Superconductivity
    • /
    • 제12권1호
    • /
    • pp.23-26
    • /
    • 2010
  • A double line commutation (DLC) type SFCL with first peak limiting function has been proposed for ideal fault current limiting operation. Very fast switching (commutation) without any arc or high voltage problems for any kind of switching device is needed for the first peak current limiting. We've tried to find suitable conditions for a successful switching of a Vacuum Interrupter (VI) with HTS elements as a Peak Current limiting Resistance (PCR).

접속·접촉불량 사고에 의한 전기화재 방지용 보호장치에 관한 연구 (A Study on Protection Device for Electrical Fire Prevention on Joint/Contact Badness Faults)

  • 최정규;곽동걸;이승철;이봉섭;박영직
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.5-6
    • /
    • 2014
  • According to 2013 fire statistical yearbook in the National Emergency Management Agency, the main cause of an electrical fire are classified to short circuit fault, overload fault, electric leakage, partial disconnection, and joint/contact badness. The occurrence factor of fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Devices(RCDs) of high sensitivity type used at single phase (220V) cut off earth leakage and overload but the RCDs can not cut off electric arc or spark to be a main cause of electrical fire. To be improved on such problem, this thesis is proposed to a auxiliary control device for RCD cut off electric arc or spark.

  • PDF

The Fire Hazard of Screwed Electric Contacts Due to Mechanical Vibration at Low Voltage Equipment

  • Choi, Chung-Seog;Kim, Young-Seok;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • 제4권2호
    • /
    • pp.18-23
    • /
    • 2005
  • There are many electrical connections in the electric apparatus and most fires due to a fault contact result from a failure or misuse of electric apparatus and installation. The fault contact happens between electrical connections by the loose and the mechanical vibration. In this paper, we have investigated thermal and electrical properties of screwed electric contacts due to the mechanical vibration. The exciter was connected to a signal generator and power amplifier that provided the vibration frequency and amplitude. The vibration, temperature and voltage data were sent to a data acquisition system (DAQ). In the case that fault contact took place, the arc happened between the screwed electric contact and electric wire, heat due to the arc was transmitted to the adjacent insulators, for which the oxide could be generated more. In addition, a spark was generated and the insulator began to melt. Thus, the possibility of electrical fire became the highest in this case. Finally, when the fault contact takes place due to vibration, the hazard of an electric accident is very high.

동기 페이져 정보를 이용한 개선된 사고거리추정 기법 (An Improved Technique For The Fault Location Estimation Using Synchronized Phasors)

  • 이찬주;김현홍;박종배;신중린;조란라도예빅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.310-312
    • /
    • 2005
  • This paper presents an improved two-terminal technique for fault location estimation. The proposed algorithm is also based on the synchronized phasors measured from the synchronized PMUs installed at two-terminals of the transmission lines. Also the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records. Also, the two-terminal fault algorithm for the long line model is derived in the spectral domain.

  • PDF

전기재해 예방을 위한 국가전기안전망 구축 방안 (A Plan for Construction of the National Electrical Safely Network to Prevent Electrical Disasters)

  • 고원식;이흥재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.216-218
    • /
    • 2009
  • In this paper, a real time monitoring and management system being operated in the ubiquitous environment was developed to monitor leakage current, load current, and arc-fault, and an electrical safety network for reasonable management of electrical risk factor was proposed. For confirmation of usefulness and reliability of the proposed safety network and system, the developed intelligent panels were applied to 28 Korean traditional houses in Jeonjoo city, and the network including the panels was operated. If the National Electrical Safety Network is completely constructed in the houses of general electrical users, the network will have an effect on that a main manager transfers from general people to expert. As a result, the electrical fires caused by an over-load, an arc-fault, and an earth-fault will be prevented.

  • PDF

고역통과 필터 및 FFT를 이용하여 아크감지 알고리즘 검증 (Verification of Algorithm for Arc Detection Using High Pass Filter and FFT)

  • 윤민호;조유정;김경탁;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제36권5호
    • /
    • pp.520-524
    • /
    • 2023
  • An algorithm was developed to detect and block serial arc currents using HPF. The AC series arc problem is that the load current is greater than the fault current and no leakage current occurs. As a solution, an arc detection method utilizing differences in high- frequency amplitudes was developed. HPT was applied to the load current and FFT was applied to eliminate low frequencies. An algorithm has been developed to detect arc waveforms when they exceed a certain value compared to the average of normal waveforms. Using one cycle of data, arc detection is faster and arc accidents are prevented.