• Title/Summary/Keyword: Ar recovery time

Search Result 14, Processing Time 0.027 seconds

Flavor Quality of Aroma Fractions Recovered from Peach Pulp (복숭아 펄프에서 회수한 방향성분 획분의 향기특성)

  • Lee, Kyoung-Hae;Lee, Young-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.921-927
    • /
    • 1995
  • Peach pulp was separated into serum and insoluble pulp by centrifugation at 11,000 rpm for 10 min. The serum portion was concentrated at $50{\sim}55^{\circ}C$ and $30{\sim}50\;mmHg$ with aroma recovery. Vapor generated at the early stage of vacuum evaporation was condensed and taken as aroma fractions: AR-1($0{\sim}5%$), AR-2($5{\sim}10$), AR-3($10{\sim}15%$), AR-4($15{\sim}20%$). Dynamic headspace concentration method was used to trap volatile compounds in aroma fractions and identification of aroma compounds was made by GC/MS. The yield of serum separated from peach pulp was 70.5% and the serum fraction contained the most of aroma compounds. Thirty-one aroma compounds, including ethylene, benzaldehyde, l-limonene and ${\gamma}-dodecalactone$ were identified. The efficiency of aroma recovery was reduced, as the recovery time was extended, as indicated by less peak numbers and peach areas of aroma fractions.

  • PDF

Measurement of the Ar Recovery Time of a Cryopump and Analysis on the Ar Instability (크라이오펌프 알곤 회복시간 측정과 알곤 불안정성 분석)

  • In, Sang Ryul;Lee, Dong Ju
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.225-230
    • /
    • 2013
  • Cryopump removes gas molecules by condensation and adsorption. Therefore, cryo-surface temperature and corresponding vapor pressure influence directly the pumping performance. If the surface temperature of any part is neither low nor high, there occurs the desorption of gas molecules condensed or adsorbed, and the emitted molecules can be captured again, which leads to a time-consuming and fluctuating change of the pressure. Though every gas can show such a pressure instability at a specified temperature range, the instability generated in a sputter system using Ar as a working gas and operating with a cryopump is especially undesirable. In this paper the cause of the argon instability is analyzed and corrective is provided through the measurement of the Ar recovery time.

Evaluation Scheme of Cryopump Performance for Gas Loads (기체부하에 대한 크라이오 펌프의 성능 평가 방안)

  • In, S.R.;Jeong, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.169-176
    • /
    • 2010
  • Cryopumps can provide economical profits with a relatively high pumping speed per size. However, it is somewhat doubtful that pumping performance of cryopums, which is very sensitive to the temperature of the adsorption panel, can be maintained or recovered fast for large continuous or impulsive gas loads. The official evaluation items indicating cryopump performance for gas loads are the maximum throughput and the crossover value. There are two other, unofficial but widely used, items, the Ar recovery time and gulp characteristics. Although these evaluation items look absolutely different with each other, there are close relations and even duplications in their test schemes. Therefore, it is necessary to study how to improve practically each test procedure, and combine or unify some procedures.

Experiment and Simulation of PSA Process for $H_2/Ar$ Mixtures gas ($H_2/Ar$ 혼합기체의 PSA 공정 실험과 모사)

  • Kang, Seok-Hyun;Jeong, Byung-Man;Choi, Hyun-Woo;Kim, Sung-Hyun;Lee, Byung-Kwon;Choi, Dae-Ki
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.2
    • /
    • pp.180-190
    • /
    • 2005
  • The PSA cycle was performed for the separation of binary gas mixture $H_2/Ar$ (80%/20%) using the six-step two-bed process. Adsorption equilibrium contains a LRC model for equilibrium adsorption isotherms and a LDF model for mass transfer. Aspen ADSIM, simulator was applied to predict the separation performance. The effect of cycle parameters such as feed rate, adsorption pressure and P/F ratio on the separation of hydrogen has been studied in experiment and simulation. In the results, maximize the recovery of hydrogen as a high purity was 13LPM feed flowrate, 120sec adsorption time, 11atm adsorption pressure and 0.1 P/F ratio in a cyclic steady-state come out since 10th cycle.

Development of Image-based Fluorescence Photobleaching Technique for Measuring Macromolecule Diffusion in Biological Porous Medium (생체 다공성 매질에서 분자 확산 측정을 위한 영상 기반 형광 광표백 기법 개발)

  • Lee, Dong-Hee;Lee, Jeong-Hoon;Park, Choon-Ho;Kim, Jung-Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2009
  • Fluorescence recovery after photobleaching (FRAP) has been widely used for the measurement of molecular diffusion in living cells and tissues. We developed an image-based FRAP (iFRAP) technique using a modified real-time microscope and a 488 nm Ar-ion laser. A fractional intensity curve was obtained from the time-lapse images of fluorescence recovery in the bleached spot to determine the diffusion coefficient of fluorescently labeled macromolecules in porous medium. We validated iFRAP through experiments with agar gels (0.5% and 1.5% w/v) containing FITC-Dextrans (10, 70 and 500 kDa MW). Further validation was performed by a Monte Carlo approach, where we simulated the three-dimensional random walk of macromolecules in agar gel model. Diffusion coefficients were deduced from the mean square displacement curves and showed good agreements with those measured by iFRAP.

Determination of Copper in Uniformly-Doped Silicon Thin Films by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang;Cha, Myeong;Lee, Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.205-209
    • /
    • 2001
  • Uniformly-doped silicon thin films were fabricated by ion beam sputter deposition. The thin films had four levels of copper dopant concentration ranging between 1 ${\times}$1019 and 1 ${\times}$ 1021 atoms/cm3 . Concentrations of Copper dopants were determined by the isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) to provide certified reference data for the quantitative surface analysis by secondary ion mass spectrometry (SIMS). The copper-doped thin films were dissolved in a mixture of 1 M HF and 3 M HNO3 spiked with appropriate amounts of 65 Cu. For an accurate isotope ratio determination, both the detector dead time and the mass discrimination were appropriately corrected and isobaric interference from SiAr molecular ions was avoided by a careful sample pretreatment. An analyte recovery efficiency was obtained for the Cu spiked samples to evaluate accuracy of the method. Uncertainty of the determined copper concentrations, estimated following the EURACHEM Guide, was less than 4%, and detection limit of this method was 5.58 ${\times}$ 1016 atoms/cm3.

Fabrication of Casting Pig Iron from Copper Smelting Slag by Carbothermic Reduction (탄소열환원 반응에 의한 동제련슬래그로부터 주철용 선철 제조 연구)

  • Choi, Moo-Sung;Choi, Dong-Hyeon;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.28 no.3
    • /
    • pp.59-67
    • /
    • 2019
  • This study was conducted to fabrication pig iron containing copper and to reduce sulfur content pig iron. Roasting test was conducted for 1 ~ 9 hours at each temperature of $500^{\circ}C$, $700^{\circ}C$, and $900^{\circ}C$. In addition, the effect of oxygen partial pressure with 0.5, 0.8, and 1 atm was carried out for 30 minutes at $900^{\circ}C$. It was found that there is no effect to reduce sulfure in pig iron through roasting and oxygen partial pressures. The addition of CaO with 15 wt.% was found to reduce sulfur content up to 0.001 wt.%. The suitable temperature and reactive time for carbothermic reduction were $1600^{\circ}C$ and 30 minutes which shows the highest recovery rate of iron from the copper slag.

Pain Relieving Effects of Nonnutritive Sucking and Facilitated Tucking on High Risk Infnats during Heelsticks Procedure (고위험 신생아의 발뒤꿈치 천자 시 비영양성 흡철과 감싸주기가 통증완화에 미치는 효과)

  • Ahn, Won-Hee
    • Korean Parent-Child Health Journal
    • /
    • v.8 no.2
    • /
    • pp.157-167
    • /
    • 2005
  • The purpose for this study is to identify the effects of nonnutritive sucking and facilitated tucking as a pain management during painful heelstick procedure. This study was a repeated measurement design. Data were collected from Sep. 15, to Oct. 20, 2005. According to the criteria twenty seven high risk infants were selected from the NICU of university hospital. The behavioral state were evaluated with the PIPP(Prematures Infants Pain Profile. PIPP, heart rate, saturation were observed without versus with nonnutritive sucking and tucking care. Statistic analysis was conducted with a wilcoxon nonparametric test. The results of this study were as follows. Pina behavior responses in nonnutritive sucking and tucking cases were lower than without treatment(Z=-4.430, p=.000), Heart rate and heart rate recovery time in nonnutritive sucking and tucking cases were attenuate decrease in heart rate(Z=-2.694, p=.005) and statistical significant differences in periods (Z=-4.229, p=.000). But, Saturation was no significant differences(Z=-3.230, p=.000). In conclusion, the application of nonnutritive sucking and tucking as an pain relieg for high risk infants is nursing intervention in pain management ar heelsticks.

  • PDF

기체부하에 대한 크라이오 펌프의 성능 평가 방안

  • In, Sang-Ryeol;Jeong, Seung-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.333-333
    • /
    • 2010
  • 크라이오 펌프는 크기에 비해 상대적으로 큰 배기속도를 가지고 있고 자체 기체 방출이 적어 비교적 쉽고 빠르게 도달압력을 낮출 수 있다. 또 초고진공 펌프로서 경쟁 상대인 터보분자 펌프보다 기체 돌입에 대한 기계적 사고 가능성이 낮다. 그러나 흡착 패널의 온도에 민감하게 반응하는 배기 성능 측면에서 볼 때 크라이오 펌프의 대유량 및 펄스 기체 부하에 대한 성능 유지 및 회복능력은 의문의 여지가 있다. 크라이오 펌프의 기체부하에 대한 공식적인 성능지표로는 최대배기량(max. throughput)과 교차(crossover)값이 있다. 전자는 연속적인 유량[$Pa{\cdot}m^3/s$]에 대해, 또 후자는 일정 기체량[$Pa{\cdot}m^3$]에 대해 흡착 패널이 20 K를 넘지 않는 가동범위를 구하는 것이다. 교차값은 넓은 의미에서 펄스 기체부하에 대한 성능으로 볼 수도 있지만 원래 목적은 진공용기를 저진공 상태에서 고진공 상태로 전환하는 시점을 정하려는 데 있다. 펌프회사에서 제공하는 사양에는 대부분 아르곤 회복시간(Ar recovery time)이라는 지표가 있는데 이는 아르곤을 상당한 유량으로 흘리다 멈췄을 때 얼마나 빨리 기저 상태로 회복되는가를 나타낸다. 보통 사양서에 제시하지는 않지만 주로 크라이오 펌프의 재생상태를 알아보기 위해 사용하는 걸프(gulp) 시험이 있는데 일정량의 기체를 펄스로 도입한 후 압력변화를 기록하여 재생후 배기성능 회복 능력을 보는 것이다. 이들은 겉보기에 서로 다르지만 한편으로는 서로 중복되거나 연관성을 가지고 있어서 실용적인 면에서 절차들을 비교, 검토 및 개선하고 때에 따라서는 적절히 결합할 수 있는 방안을 모색할 필요성이 있다.

  • PDF

Production of $[^{18}F]F_2$ Gas for Electrophilic Substitution Reaction (친전자성 치환반응을 위한 $[^{18}F]F_2$ Gas의 생산 연구)

  • Moon, Byung-Seok;Kim, Jae-Hong;Lee, Kyo-Chul;An, Gwang-Il;Cheon, Gi-Jeong;Chun, Kwon-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.228-232
    • /
    • 2006
  • Purpose: electrophilic $^{18}F(T_{1/2}=110\;min)$ radionuclide in the form of $[^{18}F]F_2$ gas is of great significance for labeling radiopharmaceuticals for positron omission tomography (PET). However, its production In high yield and with high specific radioactivity is still a challenge to overcome several problems on targetry. The aim of the present study was to develop a method suitable for the routine production of $[^{18}F]F_2$ for the electrophilic substitution reaction. Materials and Methods: The target was designed water-cooled aluminum target chamber system with a conical bore shape. Production of the elemental fluorine was carried out via the $^{18}O(p,n)^{18}F$ reaction using a two-step irradiation protocol. In the first irradiation, the target filled with highly enriched $^{18}O_2$ was irradiated with protons for $^{18}F$ production, which were adsorbed on the inner surface of target body. In the second irradiation, the mixed gas ($1%[^{19}F]F_2/Ar$) was leaded into the target chamber, fellowing a short irradiation of proton for isotopic exchange between the carrier-fluorine and the radiofluorine absorbed in the target chamber. Optimization of production was performed as the function of irradiation time, the beam current and $^{18}O_2$ loading pressure. Results: Production runs was performed under the following optimum conditions: The 1st irradiation for the nuclear reaction (15.0 bar of 97% enriched $^{18}O_2$, 13.2 MeV protons, 30 ${\mu}A$, 60-90 min irradiation), the recovery of enriched oxygen via cryogenic pumping; The 2nd irradiation for the recovery of absorbed radiofluorine (12.0 bar of 1% $[^{19}F]fluorine/argon$ gas, 13.2 MeV protons, 30 ${\mu}A$, 20-30 min irradiation) the recovery of $[^{18}F]fluorine$ for synthesis. The yield of $[^{18}F]fluorine$ at EOB (end of bombardment) was achieved around $34{\pm}6.0$ GBq (n>10). Conclusion: The production of $^{18}F$ electrophilic agent via $^{18}O(p,n)^{18}F$ reaction was much under investigation. Especially, an aluminum gas target was very advantageous for routine production of $[^{18}F]fluorine$. These results suggest the possibility to use $[^{18}F]F_2$ gas as a electrophilic substitution agent.