• Title/Summary/Keyword: Application Screening

Search Result 531, Processing Time 0.03 seconds

A Study on Screening of Surface Waves by Wave Barriers (방진구조물에 의한 표면파 산란해석)

  • Lee, Jong-Seh;Kim, Hee-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.578-581
    • /
    • 2004
  • In this paper numerical and experimental studies are conducted to examine the wave screening effectiveness of wave barriers. The numerical study is based on a finite element model of a 'sandbox' with Lysmer-Kuhlemeyer-type absorbing boundaries. Using the model, the screening effectiveness of wave barriers is studied for different barrier dimensions and distances between the source/receiver and the wave barrier. The results of the numerical modeling are compared with those of the ultrasonic experiment which is performed on an acrylic block with a drilled rectangular cut. Finally, the problem of ground transmitting vibration from a traveling train is numerically treated as a real-world application and the results are discussed in some detail.

  • PDF

Accuracy Urinalysis Discrimination Method based on high performance CNN (고성능 CNN 기반 정밀 요검사 판별 기법)

  • Baek, Seung-Hyeok;Choi, Hong-Rak;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.77-82
    • /
    • 2021
  • There are three types of urinalysis: physical test, chemical test, and microscopic test. Among these, the chemical urinalysis is an easily accessible method of the general public to compare the chemical reaction of urinalysis strip with a standard colorimetric table by sight or purchase the portable urinalysis machine separately. Currently, with the popularization of smartphone, research on the urinalysis service using smartphone is increasing. The urinalysis screening application is one of the urinalysis services using a smartphone. However, the RGB values of the urinalysis pad taken by the urinalysis screening application have large deviations due to the effect of lighting. Deviation of RGB value debases the accuracy of urinalysis discrimination. Therefore, in this paper, the accuracy of urinaylsis pad image discrimination is improved through CNN after classifying urinalysis strips taken by the urinalysis screening application based on smartphone by urinalysis pad items. Urinalysis strip was taken from various backgrounds to generate CNN image, and urinalysis discrimination was analyzed using the ResNet-50 CNN model.

Discovery of Novel DUSP4 Inhibitors through the Virtual Screening with Docking Simulations

  • Park, Hwangseo;Jeon, Tae Jin;Chien, Pham Ngoc;Park, So Ya;Oh, Sung Min;Kim, Seung Jun;Ryu, Seong Eon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2655-2659
    • /
    • 2014
  • Dual specificity protein phosphatase 4 (DUSP4) has been considered a promising target for the development of therapeutics for various human cancers. Here, we report the first example for a successful application of the structure-based virtual screening to identify the novel small-molecule DUSP4 inhibitors. As a consequence of the virtual screening with the modified scoring function to include an effective molecular solvation free energy term, five micromolar DUSP4 inhibitors are found with the associated $IC_{50}$ values ranging from 3.5 to $10.8{\mu}M$. Because these newly identified inhibitors were also screened for having desirable physicochemical properties as a drug candidate, they may serve as a starting point of the structure-activity relationship study to optimize the medical efficacy. Structural features relevant to the stabilization of the new inhibitors in the active site of DUSP4 are discussed in detail.

Primary Screening of QSAR Molecular Descriptors for Genotoxicity Prediction of Drinking Water Disinfection Byproducts (DBPs), Chlorinated Aliphatic Compounds

  • Kim, Jae-Hyoun;Jo, Jin-Nam;Jin, Byung-Suk;Lee, Dong-Soo;Kim, Ki-Tae;Om, Ae-Son
    • Environmental Mutagens and Carcinogens
    • /
    • v.21 no.2
    • /
    • pp.113-117
    • /
    • 2001
  • The screening of various molecular descriptors for predicting carcinogenic, mutagenic and teratogenic activities of chlorinated aliphatic compounds as drinking water disinfection byproducts (DBPs) has been investigated for the application of quantitative structure-activity relationships (QSAR). The present work embodies the study of relationship between molecular descriptors and toxicity parameters of the genotoxicity endpoints for the screening of relevant molecular descriptors. The toxicity Indices for 29 compounds constituting the testing set were computed by the PASS program and active values were chosen. We investigate feasibility of screening descriptors and of their applications among different genotoxic endpoints. The correlation to teratogenicity of all 29 compounds was significantly improved when the same analysis was done with 20 alkanes only without alkene compounds. The HOMO (highest occupied molecular orbital) energy and number of Cl parameters were dominantly contributed.

  • PDF

Nutritional Assessment of the Older Population: Practical Application and Limitation

  • Yoon, Jin-Sook
    • Journal of Community Nutrition
    • /
    • v.2 no.1
    • /
    • pp.36-49
    • /
    • 2000
  • Evaluation of nutritional status is an essential element in providing appropriate intervention strategies to achieve the highest level of health, Nutritional assessment of the older population is complicated by many factors which do not significantly affect the nutritional status in young adults, therefore, it should be considered in two ways; community-dwelling elders group and hospitalized or institutionalized elderly group. To sort out the individuals with nutritional problems in a community efficiently, nutrition screening tools must be simple, relatively inexpensive, and applicable to a large number of subjects. Combination of tools and indicators such as 24-hour food recall, body weight and height, and questionnaires on eating practices, and the presence of chronic diseases is practically applicable as basic tools of nutritional screening of older age group. However, the lack of validated screening techniques remains a barrier in improving nutrition. Validation is only limited to energy, BMI, protein intake of the older populations living in western countries. Further refinement of nutritional assessment tools is demanded to figure out whether those are practically applicable to community-living older adults in Asian Society. A careful and systematic evaluation of nutritional assessment tools should be carried out prior to implementation of stepwise nutrition service to the heterogeneous older population. For an in-depth nutritional assessment at the individual level, we need to extend research efforts to clarify the requirements of nutrients due to aging and diseases. More cost-effective method that will allow rapid analysis of survey results are needed so that information can be readily available to policymakers.

  • PDF

An Automatic Strabismus Screening Method with Corneal Light Reflex based on Image Processing

  • Huang, Xi-Lang;Kim, Chang Zoo;Choi, Seon Han
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.5
    • /
    • pp.642-650
    • /
    • 2021
  • Strabismus is one of the most common disease that might be associated with vision impairment. Especially in infants and children, it is critical to detect strabismus at an early age because uncorrected strabismus may go on to develop amblyopia. To this end, ophthalmologists usually perform the Hirschberg test, which observes corneal light reflex (CLR) to determine the presence and type of strabismus. However, this test is usually done manually in a hospital, which might be difficult for patients who live in a remote area with poor medical access. To address this issue, we propose an automatic strabismus screening method that calculates the CLR ratio to determine the presence of strabismus based on image processing. In particular, the method first employs a pre-trained face detection model and a 68 facial landmarks detector to extract the eye region image. The data points located in the limbus are then collected, and the least square method is applied to obtain the center coordinates of the iris. Finally, the coordinate of the reflective light point center within the iris is extracted and used to calculate the CLR ratio with the coordinate of iris edges. Experimental results with several images demonstrate that the proposed method can be a promising solution to provide strabismus screening for patients who cannot visit hospitals.

Genetically Encoded Biosensor Engineering for Application in Directed Evolution

  • Yin Mao;Chao Huang;Xuan Zhou;Runhua Han;Yu Deng;Shenghu Zhou
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.10
    • /
    • pp.1257-1267
    • /
    • 2023
  • Although rational genetic engineering is nowadays the favored method for microbial strain improvement, building up mutant libraries based on directed evolution for improvement is still in many cases the better option. In this regard, the demand for precise and efficient screening methods for mutants with high performance has stimulated the development of biosensor-based high-throughput screening strategies. Genetically encoded biosensors provide powerful tools to couple the desired phenotype to a detectable signal, such as fluorescence and growth rate. Herein, we review recent advances in engineering several classes of biosensors and their applications in directed evolution. Furthermore, we compare and discuss the screening advantages and limitations of two-component biosensors, transcription-factor-based biosensors, and RNA-based biosensors. Engineering these biosensors has focused mainly on modifying the expression level or structure of the biosensor components to optimize the dynamic range, specificity, and detection range. Finally, the applications of biosensors in the evolution of proteins, metabolic pathways, and genome-scale metabolic networks are described. This review provides potential guidance in the design of biosensors and their applications in improving the bioproduction of microbial cell factories through directed evolution.

Improved Soil Application Bioassay for Efficient Development of Natural Pre-emergence Herbicides (토양처리용 천연물제초제 개발을 위한 생물검정법 개선)

  • Kim, Jae-Deog;Hwang, Hyun-Jin;Seo, Bo-Ram;Choi, Jung-Sup;Kim, Jin-Seog
    • Korean Journal of Weed Science
    • /
    • v.31 no.3
    • /
    • pp.229-239
    • /
    • 2011
  • This study was carried out to establish an improved bioassay system on the side of practicality, pre-emergence bioassay which is more effective in developing soil application natural herbicides. A miniaturized method which have a 50 cm2 of soil surface area and was efficient by 7 times compared to the existing soil application assay ($350cm^2$ of soil surface area) was established, in which four weed species (Echinochloa crus-galli, Digitaria sanguinalis, Aeschynomene indica, and Abutilon theophrasti) were planted and grown in greenhouse. This would be applicable when the amount of screening compound is much more than 50 mg. The initial application rate was desirable at $10,000{\mu}g\;mL^{-1}$. On the other hand, the 6 well plate assay which has 4 weed species in each well containing upland soil and could be conducted in growth chamber, was established. This assay was resulted in minimizing in level of 1/14 test volume and 1/14 amounts of test compound to the conventional method that has been used for screening of synthetic compounds in KRICT, and applicable for the small amount of test compound (less than 10 mg). Therefore, the improved bioassays established in this study would be helpful for a rapid and efficient development of soil application natural herbicides.

GENE EXPRESSION AFTER THE APPLICATION OF THE FLUID-INDUCED SHEAR STRESS ON THE GINGIVAL FIBROBLAST (유체에 의해 유발된 전단력이 치은 섬유아세포 유전자 발현 변화에 미치는 영향에 관한 연구)

  • Jeong, Mi-Hyang;Choi, Je-Yong;Chae, Chang-Hoon;Kim, Seong-Gon;Nahm, Dong-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.5
    • /
    • pp.424-430
    • /
    • 2005
  • The oral cavity is humid environment mainly due to the continuous salivary flow. The reaction of oral mucosa to fluid flow is important for homeostasis and pathogenesis. The objective of this study is the screening the change of gene expression after the application of fluid induced shear stress (FISS) on the gingival fibroblast using cDNA microarray assay. The immortalized human gingival fibroblasts were grown and FISS was applied using a cone viscometer at a rotational velocity of 40 rpm, respectively for periods of 2 and 4 hours. The synthesis of cDNA was done from the extracted total RNA and cDNA microarray assay was done subsequently. The genes that showed over 1.6 in the Cy3/Cy5 or the Cy5/Cy3 value were regarded as genes influenced significantly by the FISS application ion (/M/>0.7). The " RUNX-1" was increased its expression in 2 hours group and " RUN and SH3 domain containing 1" was increased its expression in 4 hours group. The "CC020415", "cyclin L1", "interferon regulatory factor1", "early growth response 1", "immediate early response 2", and "immediate early response 3" genes were increased their expression in 2 and 4 hours after FISS application. In conclusion, we could find many genes that were probably related to the FISS application. Interestingly, most of them were placed in similar molecular pathways and these findings improve the reliability of chip data and usefulness in overall screening. From this experiment, we could find many items for further study and it will make improvement in the understanding of intracellular events in response to FISS.

Design and Implementation of Service based Virtual Screening System in Grids (그리드에서 서비스 기반 가상 탐색 시스템 설계 및 구현)

  • Lee, Hwa-Min;Chin, Sung-Ho;Lee, Jong-Hyuk;Lee, Dae-Won;Park, Seong-Bin;Yu, Heon-Chang
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.6
    • /
    • pp.237-247
    • /
    • 2008
  • A virtual screening is the process of reducing an unmanageable number of compounds to a limited number of compounds for the target of interest by means of computational techniques such as molecular docking. And it is one of a large-scale scientific application that requires large computing power and data storage capability. Previous applications or softwares for molecular docking such as AutoDock, FlexX, Glide, DOCK, LigandFit, ViSION were developed to be run on a supercomputer, a workstation, or a cluster-computer. However the virtual screening using a supercomputer has a problem that a supercomputer is very expensive and the virtual screening using a workstation or a cluster-computer requires a long execution time. Thus we propose a service-based virtual screening system using Grid computing technology which supports a large data intensive operation. We constructed 3-dimensional chemical molecular database for virtual screening. And we designed a resource broker and a data broker for supporting efficient molecular docking service and proposed various services for virtual screening. We implemented service based virtual screening system with DOCK 5.0 and Globus 3.2 toolkit. Our system can reduce a timeline and cost of drug or new material design.