• 제목/요약/키워드: Appliance System

검색결과 447건 처리시간 0.026초

Impact of User Convenience on Appliance Scheduling of a Home Energy Management System

  • Shin, Je-Seok;Bae, In-Su;Kim, Jin-O
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.68-77
    • /
    • 2018
  • Regarding demand response (DR) by residential users (R-users), the users try to reduce electricity costs by adjusting their power consumption in response to the time-varying price. However, their power consumption may be affected not only by the price, but also by user convenience for using appliances. This paper proposes a methodology for appliance scheduling (AS) that considers the user convenience based on historical data. The usage pattern for appliances is first modeled applying the copula function or clustering method to evaluate user convenience. As the modeling results, the comfort distribution or representative scenarios are obtained, and then used to formulate a discomfort index (DI) to assess the degree of the user convenience. An AS optimization problem is formulated in terms of cost and DI. In the case study, various AS tasks are performed depending on the weights for cost and DI. The results show that user convenience has significant impacts on AS. The proposed methodology can contribute to induce more DR participation from R-users by reflecting properly user convenience to AS problem.

지열히트펌프시스템의 냉방운전에 따른 성능연구 (Cooling Performance of a Ground Source Heat Pump System)

  • 이재근;정영만;구경민;황유진;장세용;김인규;진심원;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.441-446
    • /
    • 2007
  • This present study is to evaluate the cooling performance of a water-to-refrigerant ground source heat pump system(GSHP) under actually operating condition. 1 unit is selected among 10 units of the GSHP in the building to analyze the performance. The average cooling COP of the GSHP at the part load of 64% is 8.2, overall system COP is 6.19. In the GSHP system, the cooling temperature of the condenser is lower compared to the air source heat pump system. Conclusively, the cooling performance of the GSHP is higher than the air source heat pump system by 80%.

  • PDF

인터넷 가전의 원격 감시 및 제어를 위한 임베디드 리눅스 웹 서버 (An Embedded Linux Web Server for Remote Monitoring & Controlling the Internet Appliance)

  • 임성락
    • Journal of Information Technology Applications and Management
    • /
    • 제12권4호
    • /
    • pp.123-131
    • /
    • 2005
  • Since most of the conventional web servers have been designed to Provide the general purpose and user's convenience as the primary goal, there is an overhead to apply them to the embedded system for remote monitoring and controlling the operation status of the Internet appliance. To cope with this overhead, an embedded Linux web server Is suggested in this paper The basic concept is to provide miniaturization and extendability by simplifying the requirements of web server as the services to the requests of web document for the user's menu and the execution of CGI Program for monitoring and controling the Internet appliance, and satisfying only the indispensable requirements of HTTP which are necessary for the interface with the conventional web browsers. For the evaluation of its feasibility, each module has been implemented on Linux environment, and tested with the MS Explorer 6.0.

  • PDF

유도가열 조리기기용 인버터 파라미터 최적화에 관한 연구 (A Study on the Parameter Optimization of Inverter for Induction Heating Cooking Appliance)

  • 강병관;이세민;박정욱
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.77-85
    • /
    • 2009
  • With the advent of power semiconductor switching devices, power electronics relating to high frequency electromagnetic eddy current based induction heating technology have become more suitable and acceptable. This paper presents high-frequency induction heating cooking appliance circuit based on the zero current switching-PWM single ended push-pull(ZCS-PWM SEPP) resonant inverter added AC-DC converter. This inverter uses pulse-width-modulation(PWM) control method with active auxiliary quasi-resonant lossless inductor snubbers and a switched capacitor. To improved the transient performance, the PI controller is applied for this system. For the systematic parameter optimization of the PI controller, the gradient-based optimization algorithm is applied. The performance of optimized parameters is evaluated using simulation and experimental test. These results show that the proposed systematic optimal tuning method improve the transient performances of this system.

턱관절음양균형요법을 이용한 섬유근육통증후군 치험1례 (A Case of Fibromyalgia Treatment Using Yin-yang Balancing Therapy of Temporomadibular Joint (TMJ))

  • 이상배;이영준
    • 턱관절균형의학회지
    • /
    • 제10권1호
    • /
    • pp.32-36
    • /
    • 2020
  • 본 증례에서는 섬유근통 증후군을 진단받고 마약성 진통제와 링겔, 패치 등을 다년간 지속적으로 투여받은 환자에게서 한의학적 치료인 턱관절음양균형요법으로 유의한 효과를 얻어 보고하는 바이다.

턱관절음양균형요법을 이용한 연축성 사경증 치험 1례 (A Case of Cervical dystonia Treatment Using Yin-yang Balancing Therapy of Temporomandibular Joint)

  • 이상배;이영준
    • 턱관절균형의학회지
    • /
    • 제12권1호
    • /
    • pp.15-21
    • /
    • 2022
  • 본 증례에서는 턱관절 문제가 시작 된 후 연축성 사경증이 발병한 뒤 다년간의 치료로 호전이 없던 환자에게서 턱관절 음양균형요법(Yin-yang Balancing Therapy of TMJ)을 위주로 침, 추나, 약물요법 등의 한의학적 치료를 통해 유의한 효과를 얻어 보고하는 바이다.

PLC 기반의 홈 네트워크 미들웨어 설계 및 구현 (Design and Implementation Middleware of the Home Network based PLC)

  • 전병찬;김혁진;김동균
    • 한국컴퓨터산업학회논문지
    • /
    • 제9권1호
    • /
    • pp.11-20
    • /
    • 2008
  • 유비쿼터스 응용 서비스 중의 하나인 홈 네트워크 서비스는 가정 내에서 네트워크로 연결된 정보가전기기의 원격제어 및 모니터링 서비스, 다른 기기와 연동 서비스, 보안 서비스 등 다양한 서비스를 시간과 장소에 구애받지 않고 제공한다. <중략> 본 논문에서는 홈 네트워크의 무선 센서 네트워크 환경 구축을 위하여 Zigbee를 이용하고 대기전력 모듈을 통한 기기 전력 상태 정보 및 기기 응용 서비스를 제공하는 테스트베드 설계 구축한다. 흠 네트워크 테스트베드의 솔루션은 추가 배선 없이 기존의 전력선을 이용하기 때문에 비용이 적게 들고 설치가 용이하다. 정보가전기기 제어 및 모니터링을 위해 메인 서버와 각 기능에 대한 제어를 맡아서하는 게이트웨이로 구현한다. 구현된 시스템은 댁내/외에서 댁내에 가전기기를 제어 및 모니터링이 가능하도록 구현한다.

  • PDF

인덕션 쿡탑 기구물 형상변경이 Heatsink 및 Coil 냉각성능에 미치는 영향에 대한 연구 (Study on the Cooling Performance of Heatsink for Induction Cooktop using Computational Fluid Dynamics)

  • 박동호;권명근;이동범;서응렬;박용종
    • 한국유체기계학회 논문집
    • /
    • 제18권3호
    • /
    • pp.33-37
    • /
    • 2015
  • A numerical study on the IPM/Bridge Diode cooling and coil cooling has been performed. Results are presented as plots of thermal resistance, temperature drop and RPM-ratio. CFD analysis for conventional cooling system has been performed as a reference case. As the RPM-Ratio was increased, heatsink thermal resistance and coil temperature were decreased. IPM/Bridge Diode thermal resistance and temperature of the coil is tended to be trade-off. The temperature of coil closest to the AC-motor fan showed the most significant change in accordance with duct design. The temperature of coil located at the top of DC-motor fan showed the most significant variation as the cooling air passes the heatsink fin area.

기기별 전력 모니터링 시스템 개발에 관한 연구 (A Study on Electric Power Monitoring System per Appliance)

  • 박성욱;김종식;임수진;황보세희;손준익;이인용;왕보현
    • 한국지능시스템학회논문지
    • /
    • 제20권5호
    • /
    • pp.638-644
    • /
    • 2010
  • 본 연구에서는 일반 가정에서 Smart Grid를 통하여 누릴 수 있는 서비스를 발굴하고, 이러한 서비스를 구현할 수 있는 기기별 전력 모니터링 시스템을 구현하였으며, 모니터링한 데이터를 분석하였다. 기기별 전력 사용현황을 수집하고 이를 분석함으로써, 모니터링 시스템에 표시되고 있는 전력사용현황이 어떤 기기의 전력사용현황인지 사전에 정의된 프로토콜 없이 알 수 있다. 나아가서 전력 절감 방법 제시, 지능적인 대기전력 차단 및 복구, 기기의 이상여부 감시와 같은 서비스를 구현할 수 있을 것이다. 본 연구에서는 이러한 시나리오의 실현 가능성을 점검하기 위해 기기별 전력 모니터링 시스템을 개발하여 가정 내 전력소비의 대부분을 차지하는 냉장고, 전기밥솥, TV, 세탁기 샘플에 대하여 전력소비패턴을 수집하여 database화 하였다. 또한 이 database를 분석하여 제시한 서비스들을 구현하는데 필요한 기본 기능인 기기식별이 전력사용 패턴분석을 통하여 가능함을 보였다.