• Title/Summary/Keyword: Appliance System

Search Result 447, Processing Time 0.025 seconds

Impact of User Convenience on Appliance Scheduling of a Home Energy Management System

  • Shin, Je-Seok;Bae, In-Su;Kim, Jin-O
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.68-77
    • /
    • 2018
  • Regarding demand response (DR) by residential users (R-users), the users try to reduce electricity costs by adjusting their power consumption in response to the time-varying price. However, their power consumption may be affected not only by the price, but also by user convenience for using appliances. This paper proposes a methodology for appliance scheduling (AS) that considers the user convenience based on historical data. The usage pattern for appliances is first modeled applying the copula function or clustering method to evaluate user convenience. As the modeling results, the comfort distribution or representative scenarios are obtained, and then used to formulate a discomfort index (DI) to assess the degree of the user convenience. An AS optimization problem is formulated in terms of cost and DI. In the case study, various AS tasks are performed depending on the weights for cost and DI. The results show that user convenience has significant impacts on AS. The proposed methodology can contribute to induce more DR participation from R-users by reflecting properly user convenience to AS problem.

Cooling Performance of a Ground Source Heat Pump System (지열히트펌프시스템의 냉방운전에 따른 성능연구)

  • Lee, Jae-Keun;Jeong, Young-Man;Koo, Kyoung-Min;Hwang, Yu-Jin;Jang, Se-Yong;Kim, In-Kyu;Jin, Sim-Won;Lee, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.441-446
    • /
    • 2007
  • This present study is to evaluate the cooling performance of a water-to-refrigerant ground source heat pump system(GSHP) under actually operating condition. 1 unit is selected among 10 units of the GSHP in the building to analyze the performance. The average cooling COP of the GSHP at the part load of 64% is 8.2, overall system COP is 6.19. In the GSHP system, the cooling temperature of the condenser is lower compared to the air source heat pump system. Conclusively, the cooling performance of the GSHP is higher than the air source heat pump system by 80%.

  • PDF

An Embedded Linux Web Server for Remote Monitoring & Controlling the Internet Appliance (인터넷 가전의 원격 감시 및 제어를 위한 임베디드 리눅스 웹 서버)

  • Rim Seong-Rak
    • Journal of Information Technology Applications and Management
    • /
    • v.12 no.4
    • /
    • pp.123-131
    • /
    • 2005
  • Since most of the conventional web servers have been designed to Provide the general purpose and user's convenience as the primary goal, there is an overhead to apply them to the embedded system for remote monitoring and controlling the operation status of the Internet appliance. To cope with this overhead, an embedded Linux web server Is suggested in this paper The basic concept is to provide miniaturization and extendability by simplifying the requirements of web server as the services to the requests of web document for the user's menu and the execution of CGI Program for monitoring and controling the Internet appliance, and satisfying only the indispensable requirements of HTTP which are necessary for the interface with the conventional web browsers. For the evaluation of its feasibility, each module has been implemented on Linux environment, and tested with the MS Explorer 6.0.

  • PDF

A Study on the Parameter Optimization of Inverter for Induction Heating Cooking Appliance (유도가열 조리기기용 인버터 파라미터 최적화에 관한 연구)

  • Kang, Byung-Kwan;Lee, Se-Min;Park, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.77-85
    • /
    • 2009
  • With the advent of power semiconductor switching devices, power electronics relating to high frequency electromagnetic eddy current based induction heating technology have become more suitable and acceptable. This paper presents high-frequency induction heating cooking appliance circuit based on the zero current switching-PWM single ended push-pull(ZCS-PWM SEPP) resonant inverter added AC-DC converter. This inverter uses pulse-width-modulation(PWM) control method with active auxiliary quasi-resonant lossless inductor snubbers and a switched capacitor. To improved the transient performance, the PI controller is applied for this system. For the systematic parameter optimization of the PI controller, the gradient-based optimization algorithm is applied. The performance of optimized parameters is evaluated using simulation and experimental test. These results show that the proposed systematic optimal tuning method improve the transient performances of this system.

A Case of Fibromyalgia Treatment Using Yin-yang Balancing Therapy of Temporomadibular Joint (TMJ) (턱관절음양균형요법을 이용한 섬유근육통증후군 치험1례)

  • Lee, Sang Bae;Lee, Young Jun
    • Journal of TMJ Balancing Medicine
    • /
    • v.10 no.1
    • /
    • pp.32-36
    • /
    • 2020
  • This case is witten for presenting the effect of the yin-yang balancing therapy using the TMJ balancing appliance which normalizes the yin and yang balance of the brain-nervous system including the Meridian system. The balancing appliance was used in patient with fibromyalgia syndrome, and clinical outcome measurements were performed through clinical observations in specific movement and actions. The patient displayed positive changes after the treatment and the effect was well-maintained during the treatment period. For the more precise evaluation, clinical and biological studies of temporomadibular balancing therapy (TBT) are needed.

A Case of Cervical dystonia Treatment Using Yin-yang Balancing Therapy of Temporomandibular Joint (턱관절음양균형요법을 이용한 연축성 사경증 치험 1례)

  • Sang Bae Lee;Young Jun Lee
    • Journal of TMJ Balancing Medicine
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 2022
  • This case is witten for presenting the effect of the TMJ balancing therapy using the TMJ balancing appliance which normalizes the yin and yang balance of the brain-nervous system including the Meridian system. The balancing appliance was used in patient with cervical dystonia, and clinical outcome measurements were performed through clinical observations in specific movement and actions. The patient displayed positive changes after the treatment and the effect was well-maintained during the treatment period. For the more precise evaluation, clinical and biological studies of temporomandibular balancing therapy (TBT) are needed.

Design and Implementation Middleware of the Home Network based PLC (PLC 기반의 홈 네트워크 미들웨어 설계 및 구현)

  • Jean, Byoung-Chan;Kim, Hyeock-Jin;Kim, Dong-Kyun
    • Journal of the Korea Computer Industry Society
    • /
    • v.9 no.1
    • /
    • pp.11-20
    • /
    • 2008
  • Home network service, which is a part of Ubiquitous application service provides remote control and monitoring service, other appliance and peristaltic service, security service of appliance is connected to network in the home. <중략> By using gateway which is implemented undertook control of each function and using main server for controlling and monitoring of appliance, implemented system which is able to control the appliance in home from inter/outside is implemented.

  • PDF

Study on the Cooling Performance of Heatsink for Induction Cooktop using Computational Fluid Dynamics (인덕션 쿡탑 기구물 형상변경이 Heatsink 및 Coil 냉각성능에 미치는 영향에 대한 연구)

  • Park, Dong Ho;Kwon, Myoung Keun;Lee, Dong Beom;Seo, Eung Ryeol;Park, Yong Jong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.33-37
    • /
    • 2015
  • A numerical study on the IPM/Bridge Diode cooling and coil cooling has been performed. Results are presented as plots of thermal resistance, temperature drop and RPM-ratio. CFD analysis for conventional cooling system has been performed as a reference case. As the RPM-Ratio was increased, heatsink thermal resistance and coil temperature were decreased. IPM/Bridge Diode thermal resistance and temperature of the coil is tended to be trade-off. The temperature of coil closest to the AC-motor fan showed the most significant change in accordance with duct design. The temperature of coil located at the top of DC-motor fan showed the most significant variation as the cooling air passes the heatsink fin area.

A Study on Electric Power Monitoring System per Appliance (기기별 전력 모니터링 시스템 개발에 관한 연구)

  • Park, Sung-Wook;Kim, Jong-Shick;Lim, Su-Jin;HwangBo, Sea-Hee;Son, Joon-Ik;Lee, In-Yong;Wang, Bo-Hyeun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.5
    • /
    • pp.638-644
    • /
    • 2010
  • This paper presents ideas of service scenarios for home residents using electric power monitoring system per appliance, the implementation of the monitoring system, and analysis of acquired electric power usage pattern. By acquiring and analyzing electric power usage pattern, home residents can get information of power usage pattern of every legacy (non-Demand Response-ready) appliance. Further they can get pieces of recommendation how to reduce energy consumption, intelligent standby power blocking service, and alarming service to abnormality of appliances. In order to check the feasibility of the ideas, a system that can acquire electric power pattern per appliance is implemented, and electric power pattern of some appliances are stored to a database and it was analyzed to show if auto-identification of a type of a device is possible, which is a basic required function for the scenarios presented.